Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹49.4 L
EMD Value
₹98,800
Closing Date
6 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8646 PROVISION OF CERTAIN REVENUE AND MINOR WORKS UNDER GE (CENTRAL) PUNE
2025_MES_738975_1
8646 PROVISION OF CERTAIN REVENUE AND MINOR WORKS UNDER GE (CENTRAL) PUNE
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central)
₹98,800
Yes
8 Nov 2025
8 Nov 2025
8 Dec 2025
8 Nov 2025
6 Dec 2025
22 Nov 2025
S&F joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), Fe 410 -W (Gde- E- 250) quality- A complete all as specified & directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde-E-250) quality- A complete all as specified & directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4), the surface even and smooth without extra cement complete all as specified & directed.
M&L for finishing walls with acrylic smooth exterior paint of required hade : new work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed.
S&F mild steel framed work such as grills, framed guard bars etc and similar work confirming to Fe-290, grade E-165 complete all as specified & directed.
S&F posts and struts in fencing including cutting tops to shape as directed., drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified & directed.
S&F ornamental and intricate design framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; and similar work con-forming to Fe 290.Gde-E-165 complete all as specified & directed.
S&F 6.00mm thick, fibre glass reinforced translucent plain sheeting with 100mm wide side lap fixed with coach screw and washer in roof, wall etc complete all as specified & directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified & directed.
M&L for TMT bar 10mm dia and over cut to length bent to shape reqd incl cranking bending etc complete all as specified & directed. & binding with MS wire (annealed) not less than 0.9mm dia in reinforcement complete all as specified & directed.
All as per srl item No 63 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified & directed.
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash complete all as specified & directed.
M&L for preparing old plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash complete all as specified & directed.
M&L for earthwork in excavation by mechanical means (hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) in all kinds of soil, including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 m, complete all as specified & directed.
M&L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in benching, coping etc complete all as specified & directed.
S&F 150mm dia perforated UPVC Pipes (SCH-40) laid and jointed upto sb soil water levelor as directed. by engr-in-charge, including inverted earthen pots with holes in trenches complete all as specified & directed.
M&L for removing excavated material (soil) to a distance exc 50m but n exc 250 and depositing where directed. at a level n exc. 1.5 m above the starting point complete all as specified & directed.
M&L for removing excavated material (soil) to a distance exc 250m but not exc 500m and depositing where directed. at a level n exc. 1.5 m above the starting point complete all as specified & directed.
M&L for RCC pipes class NP-3 with socketed ends laid and jointed complete all as specified & directed. with rubber ring joints of 300mm dia complete all as specified & directed.
M&L for PCC 1:3:6 type C2 using 40mm graded agg as in bed to drain pipes including forming cradles for 300mm pipe complete all as specified & directed.
M&L for reinforced cement concrete design mix M- 25 grade as in Columns, pillars, piers, posts and struts complete all as specified & directed.
M&L for 10mm thick plaster on roof for laying in CM 1:3 water proofing treatment, with using WPC complete all as specified & directed.
Supply only integral water proofing compound.
M&L for APP based polymeric 3mm thick (minimum), weighing not less than 3.6 Kg/ Sqm prefabricated fire layer water proofing membrane reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over compatible primer at 0.70 Litre/Sqm of density at 25degre Centigrade 0.87-0.89 Kg/Litre and viscosity 70-160cps or cold sticker, application of APP modified membrane shall be by torch application all as specified and as directed., Three course roof treatment consist of as under :- (i) Applying one coat of bituminous primer conforming to IS-3384 @0.70 Ltr per sqm, (ii) laying of APP based membrane as specified thickness and weight (iii) Applying provide two coats of Bitumastic- aluminum paint
M&L for 75mm thick PCC (1:3:6) type B2 (using 20mm graded aggregate) as in plinth protection/hard standing, finishing cement concrete surface even and smooth without using extra cement complete all as specified & directed.
M&L for precast coloured, chequered cement concrete tiles, glossy finish of size 300 x 300mm x 20mm thick, conforming to IS-1237 (2006) set jointed and pointed in neat cement slurry in floor laid over and including 20mm thick screed bed in CM (1:6) complete all as specified & directed.
M&L for earthwork in excavation by mechanical means (hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed., within a lead of 50 m complete all as specified & directed.
M&L for rendering 10 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified & directed.
M&L for cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in bed blocks, coping, benching, bed block for rungs, window cills etc including necessary form work and complete all as specified & directed.
M&L for extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified & directed.
Supplying, laying and testing complete all as specified & directed. GI tube medium grade 20 mm bore with all fittings laid in trenches complete all as specified & directed.
Supply and fixing of gate valve 20 mm bore complete all as specified & directed.
Each Job
M&L for concealed point wiring on wall/ceiling with necessary fixing arrangements with PVC-FRLS-H insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia including all accessories/fittings such as junction boxes, bends, tee, elbow etc alongwith required size Modular boxes including modular frame/cover plate suitable for mounting switches/sockets etc including PVC-FRLS -H insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing complete all as specified and directed. and directed for the following:- (a) One light/Exhaust Fan/ceiling fan & One Bell/buzzer point controlled by one switch.
(b) One switch socket outlet point 3 pin 5 Amps on Independent board.
All as per srl item no.111 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly for one 15 amps socket outlet point on independent board complete all as specified and directed.
Supply and fixing of LED 18/20 Watt light fitting Baton integrated LED channel, integral sleek extruded polycarbonate LED Channel with white acrylic cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed.
S&F LED light fitting surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver complete in all respect of 10W capacity complete all as specified and directed.
Supply and fixing of building security LED fitting upto 40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete along with suitable size/bore GI pipe bracked duly cut to size and bent to shape , duly painted incl necessary clamps as required to fix on concrete/steel poles incl taking old unsve light & GI bracket any type and size complete all as specified and directed.
S&F ceiling rose ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F modular switch 6A SP one - way 230V white ivory finish complete all as specified and directed.
S&F modular switch 16A SP one - way 230V white ivory finish complete all as specified and directed.
S&F modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified and directed.
S&F modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified and directed.
Supply & fixing of SPN distribution box, double door in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 04 way, complete all as specified and directed.
Supply & fixing of MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply & fixing of MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply and fixing Exhaust fan AC single phase 230 volts for size 300 mm sweep, including making hole and fixing arrangement including nut, bolts, washer etc, making good the disturbed surfaces matched with existing finishes comprising with necessary eletric connection with suitable copper wire from ceiling rose complete all as specified and directed.
M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal/coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Supply, laying, testing and commissionnig of LT cables 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminum conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/Bus Bar/DB etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall 6 sq mm 2 core complete all as specified and directed.
M&L for excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable in soft/loose and getting out complete all as specified and directed.
M&L for removing excavated material to a distance n.exc 50m and depositing where directed at level not exceeding 1.5m above the starting point omplete all as specified and directed.
M&L GI Tubes, 'light grade', galvanised, with all fittings laid in trenches of size 50 mm dia omplete all as specified and directed.
M&L for fixing of electrical conduit underground HDPE/DWC pipe of size not less than 50 mm dia including all necessary clamping and fixing arrangement complete all as specified and dircted.
Supply and fix fan speed regulator, electronic step type, suitable for single phase AC, 240 volts, 50 Hz, complete all as specified and directed.
Supply and fixing ceiling fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement such as nut, bolts, washer etc, making good the disturbed surfaces matched with existing finishes comprising with necessary eletric connection with suitable copper wire from ceiling rose complete all as specified directed.
M&L for cutting of road/hard standing and making good with PCC (1:2:4) type B 1 using 20mm graded stone aggregate complete all as specified and directed.
M&L for fixing of Orange electrical conduit underground HDPE/DWC pipe of size 80 mm dia including all necessary clamping and fixing arrangement complete all as specified and dircted.
oxide primer of any tint, CPRI Approved with locking arrangements with & including 4 Nos Aluminium busbar of rating 200 Amp on base insulators with MCCB 100 amp 25 kA, 4 Pole with with adjustable thermal setting for incoming with & including necessary platform and grouting of panel as per manufecturer's instructions complete all as specified and directed.
Per Point
Each Set
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TENDER8646.pdf
Tender Documents • 1.55 MB
BOQ_827449.xls
BOQ • 4.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .