Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹65.1 LAccepted-AOC 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹71.3 L+₹2.1 L (2.98%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹79.7 L+₹10.5 L (15.2%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | 3 | Rejected-Finance Not L1 |
Tender Value
₹90 L
EMD Value
₹1.8 L
Closing Date
28 Sept 2024, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
REPAIR/MAINT GOD 2/4/6 POLE STRUCTURE FENCING AND CONNECTED ITEMS AND REPAIR/MAINT OF 11 KV HT CABLE INCLUDING FAULT DETECTIONS LOCALIZATION AND RECTIFICATION AND CONNECTED ITEMS UNDER GE EM LUCKNOW
2024_MES_655744_2
CWE/LKO/EM/T-16 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EM Lucknow
₹1.8 L
Yes
20 Nov 2024
31 Aug 2024
5 Oct 2024
31 Aug 2024
28 Sept 2024
7 Sept 2024
31 Aug 2024 - 7 Sept 2024
Amount
Dismantling air break gang operated switches & DO unit vertical/horizontal mounted including insulators and operating machanisum for repapir/replacement of brocken/worn out components and insulators for replacement etc complete as specified and directed
Supply, fix, testing and commissioning of air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 15 Nos porcelain insulators (09 Nos insulator for gang operated switch & 06 Nos insulator for drop out fuse unit including suitable rating fuse) and steel channel frame, GI operating rod 25mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including 7 levers lock complete suitable for current rating of 400 Amps HT 11 KV working pressure all as specified and directed.
All as per item No 2 here in before but for current rating of 200 Amps HT 11 KV working pressure
Disconnecting the all existing electrical connection from four pole structure & taking out unserviceable lighting arrestor etc complete as specified and directed
S&F lighting arrestor explusion type complete with all fitting, transmission class, discharge capacity 65 kilo amps suitable for 11000 volts all as specified.
Disconnecting the all existing electrical connection from four pole/two pole structure & taking out unserviceable/ burnout HT jumpher /busbar and supplying and fixing of new jumpers/bus bar made of ACSR conductor of existing size including PVC sleeves suitable for 11 KV on HT Four/ two pole structure having 2/3 /4 incoming/outoing feeder including , lugs , nut bolts and washers etc complete all as directed at site by Engr-in-charge.
M&L for servicing of GOD mounted on pole with cleaning the moving and fixed contact and removing the old greas and greasing the moving and fixed contact of GOD with new grease incl tighting of nut,bolt and washer of GOD complete all as directed by engineer-in-charge
M&L pin type insulator porcelain, vitreous white, brown or green insulator incl one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut, 150mm height, 150 mm dia suitable for 11000 volt grade incl taking down old one complete as specified.
M & L Danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M.S clamps , bolts and nuts of approved size, for HT, 25mmX20mmX 1.6mm size incl taking down old one complete all as specified and directed.
M&L for making earthing high conductive, non corosive maintenance free, non fluctuation of ohmic value 80 mmX3000mm (inner strip-3000x50x6mm, connection terminal 100x50x6mm, therminal hole 16mm, Inner filling CCM lectrode pipe-B class) GI pipe in pipe filled with super conductive crysteline with earth plus 50 kg containing mixture of graphite, Sulfate, , Silica,ALumina , Iron Oxide, Titanium oxide, calcium oxide , Magnesium oxide , Sodium oxide , Zink oxide etc) back fill compound should be ROHS including heavy duty polymer Earth pit chember with cover and S&F of GI strip 32x6 mm required at site for connection of earthing with any type equipment complete all accesories for design modification to achieve the earth terminal rod resistance value below 1 ohm complete all as specified and directed by Engineer-in-Charge.
Preperation of old painted surface and painting with 4 pole/two pole structure of HT steel tubular pole 11 mtr long from bottom to top incl all iron structure with asian aluminium paint and painting to bottom up to 1.5 mtr height from top of PCC coping with asian synthetic enamel paint one coats in Red /ylloow/blue alternate strip incl numbering in 8 cm height of number with black paint dully approved by Engineer-in-charge and complete all as specified and directed
S&Fn in repair Cable jointing kit for 11 KV (earthed ) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 sqmm, 3 core incl cutting the unserviceable portion and jointing cable in RYB phase sequence and testing complete as specified and directed
All as per item No 12 herein before but size of 120 Sqmm to 185 Sqmm
All as per item No12 herein before but size of 240 Sqmm to 300 Sqmm
S&F in repair Cable jointing kit for 11 KV (earthed ) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 sqmm, 3 core incl cutting the userviceable portion and jointing cable in RYB phase sequence and testing complete as specified and directed
All as per item No 15 herein before but size of 120 Sqmm to 185 Sqmm
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc complete as specified and directed. Note- Punned thicknes shall be measured.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Demolition of brick work built in cement mortar complete all as specified and directed by -in-charge.
M & L for Brick work with fly ash old size , straight or curved on plan exc 6 mtr mean radious built in cement mortar (1:4) for transformer foundation , dwarf wall for fencing etc complete all as specified and directed
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with ater all as specified and directed .
M & L for Rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete surface finished fair and even complete for transformer foundation , dwarf wall of fencing etc all as specified and directed .
Demolition of cement concrete unreinforced complete all as specified and directed by -in-charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate in foundation, filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate in foundation, filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 , using 20mm graded stone aggregate as in copings, benching and the like including weathering , slightly rounded or chamered angles and throating for transformer foundation , dwarf wall of fencing etc including necessary form work all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F Mild steel work of angle iron or flat iron etc for railings, balusters, nosing to steps including embeding in concrete and screwing etc, flate iron for posts , & struts in fencing etc including cutting tops to shape as directed, drilling holes , notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling , bolting or riveting etc & similar work conforming to Fe 290 gde E-165 complete all as specified and directed.
S&F MS framed work as in doors or gates of angle or other section etc to be prepared for hanging and including either hooks and hinges etc with end of bars shouldered and /or reiveted and welded complete all as specified and directed .
S&F Mild steel screw bolts (Machine made), 11 to 15 mm neck dia with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm but n exc 10 cm long complete all as specifed and directed.
Dismantling fencing wire mesh any type
Supplying and fixing Welded steel wire fabric wt n.exc 4 Kg/Sqm, any shape complete all as specified and directed by Engr -in-charge
M&L for Preparation of new or previous untreated steel and iron surfaces of any description over 10 cm width or girth , not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Preparation of old painted surface of steel and iron surfaces of any description over 10 cm width or girth , not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for two coats of cement base paint over a coat of cement base primer incl preparation of newly plastered surfaces etc complete all as specified .
M&L for one coats of cement base paint incl preparation of old plastered surfaces etc complete all as specified .
M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate 75mm thick as sub base of floors complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade set and jointed with neat grey cement and pigment including 40mm thick sand cushion etc complete all as specified and directed by Engr in-charge
Material and labour for sprading of stone aggregate of nominal size not more than 40mm inside fencing of RMU /transfromer manually without damaging any equipments, cable or parts spreading & levelling of finished gravel uniformaly in layers n. exc. 15 cm thick watered and rammed to true surface all as specified and directed
M&L Mild steel TMT bars 10mm dia and over , cut to length , bent to shape requirred including cranking, bending spirally for hooping for column , hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed for cable ducts and similar other works .
M&L reinfoced cement cement concrete (Nominal mix) 1:2:4 type B-1 using 20 mm graded stone aggregate for duct cover , slab and similar work complete all as specified and directed. Note :- Rate is deemed to be included for neessary formwork , transportation and placing as per direction of Engr-in -charge .
M & L for cutting and removing grass, vegetation bushes , surface dressing etc from surrounding 4 pole/2 pole HT structure/tansformer/RMU/CSS and outside area of HT/LT installation and removing all rubbish to a distance not exceeding 50 m as directed.
Material and labour for fabricating , supplying and installing Retro Reflective sign board, consisting of 5 feet x 4 feet frame for writing made of 25mmx25mm medium grade SS 304 with 3 mm ACP cladding both sides ( ie 3mm ACP + 3mm ACP) glued together for writing on both sides. Writing shall be of Retro reflecting over same sheeting of letter sizes not less than 75mm and to be adjusted all as per site requirement and direction of Engr-in-Charge. ACP cladding shall be fixed with frame with riveting or clamping to hold with frame. Board shall be fitted on 50mm dia SS grade 304 legs of length 2.60 M i.e 2 Mtr above ground level and 60 CM embedded in PCC 1:2:4 type B1 block of size 45cmx45cmx60cm including necessary excavation, earthwork and dismantling of old vintage sign board complete all as directed by Engr-in-charge
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm laid dry in trenches for the protection of underground cable complete all as specified and directed
All as per srl item No 47 here-in-before but using old cable cover obtained from excavation shall be used
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 80 to 100 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections for crossing of culverts/nallah /road etc of size 100 mm bore
All as per item No 50 above but 80 mm bore
Disconnecting faulty 11 KV HT cables of any size and any length from both ends Hiring of cable fault detector machine to detect exact position of fault including pressure test for removing the moisture in XLPE /PVC HT cable, 11000 Volts grade heavy duty aluminium conductor of any size and any length , removal of Fault, Re-connections and testing of cables after removal of fault including excavation, returung filling, Removal, relaying of cable protection cover etc complete as specified and directed. Note : (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Contractor or his rep shall come to the site of breakdown within one hour of notification of breakdown alongwith fault locating machine and manpower. In case the rep or contractor shall not come to the site of breakdown and not to start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contractor and will be deduct from his dues.
Supplying, laying, jointing, testing and commissioning in replacement HT under ground electric power cable Crossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts earthed cross sectional area 185 Sqmm , 3 core ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles/wall etc. complete all as specified and directed.
All as per item No 53 here-in before but cross sectional area 150 Sqmm , 3 core
All as per item No 53 here-in before but cross sectional area 120 Sqmm , 3 core
All as per item No 53 here-in before but cross sectional area 95 Sqmm , 3 core
S&F in repairs Cable jointing kit for 11 KV (earthed ) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 95 sqmm, 3 core incl cutting the userviceable portion and jointing cable in RYB phase sequence and testing complete as specified and directed
All as per item No 57 herein before but size of 120 Sqmm to 185 Sqmm
M&L horizontal boring by trenchless technology using ultra sound technique and necessary machine and inserting HDPE casing pipe with fittings of 110mm dia having working pressure 0.6 Mpa along road and under pavements/hardstanding crossing in all types of soil at prescribed depth ( in no case depth of boring less than 1.7 M from the road surface) up to 200 meters of drilling longitudinal or 3 to 4 roads crossing should be possible , for passing of HT Cable including all civil works & reinstatement as per BMP standards complete all as specified and directed.Make Tirupati / Finolex/Supreme/Prince Note:- (i) Cost of jointing of HDPE pipe with jointing material and T&P, if required at site shall deemed to be included in quoted rate. (ii) Contractor shall take written clearance of Gas pipe line , OFC, HT Cable, Water pipe line and any other utilities from concerned department before trenchless work, if any damages to existing services such as road, path & Hard stading etc occured during work the same to be replaced/repair by the contractor and the cost of the same shall deemed to be included in the quoted rates.
S&F cable route markers made out of PCC block (1:3:6) type C-1 using 20 mm graded stone aggregate size (bottom 400mmx 100 mm thick)+Top-300x100mm thick+height-1200mm(60 cm burried in ground ` DANGER/11 KV UG cable MES' embossed on route marker including excavation and earth work and painting the yellow colour above the ground and write the black colour complete all as specified and directed
Dismantling taking down old cross arms, clamps, braces etc of any section from pole including nuts, bolts, washers and remove from site complete all as specified and as directed by Engineer-in-Charge.
Dismantling of insulators any type and any size and remove from site complete all as specified and as directed by Engineer-in-Charge.
Dismantling of unsed steel poles any type any size complete all as specified and as directed by Engineer -in-charge
Dismantling of unsed concrete poles any type any size complete all as specified and as directed by Engineer -in-charge
Dismantling of unused stay assembly any type and any size and remove from site complete all as specified and as directed by Engineer-in-Charge.
Disconnecting, dismantling and taking down carefully ACSR conductor from poles of any size and setting a side complete all as specified and as directed by Engineer-in-Charge.
MTR GROUP & COMPANY (BID ID -3109331)
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3118956)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .