Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 CrAccepted-Finance | ₹19.5 Cr | L1 | Accepted-Finance YES |
| 2 | L2₹21.4 CrAccepted-Finance | ₹21.4 Cr | L2 | Accepted-Finance YES |
| 3 | L3₹22.2 CrAccepted-Finance D 7 7431 VASANT KUNJ NEW DELHI 110070 | NEW DELHI | NEW DELHI | DELHI | 110070 | ₹22.2 Cr | L3 | Accepted-Finance YES |
| 4 | L4₹22.8 CrAccepted-Finance | ₹22.8 Cr | L4 | Accepted-Finance YES |
| 5 | L5₹22.9 CrAccepted-Finance | ₹22.9 Cr | L5 | Accepted-Finance YES |
Tender Value
₹24.7 Cr
EMD Value
₹34.7 L
Closing Date
18 Jun 2020, 11:00 amClosed
Dr B K Singh CCE
Chief Construction Engineer (RandD) Central Rao Tula Ram Marg Behind Army HQ Camp Delhi Cantt 110 010
PROVISON OF ADDITIONAL RESIDENTIAL FACILITIES AT OFPKR KORWA
2020_DRDO_559989_1
CCE(RandD)C/OFPKR/2020-21
Limited
Civil Works
540 days
KORWA
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,000
Yes
Chief Construction Engineer (RandD) Central
₹34.7 L
Yes
21 Jul 2020
19 May 2020
19 Jun 2020
20 May 2020
18 Jun 2020
20 May 2020
Amount
CHAPTER - I EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge
All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
Supplying and filling with approved earth from outside MoD land filling in over area in layers not exceeding 20 cm in thickness at all heights and depths including levelling, watering compaction etc all complete.
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :
All kinds of soil
CHAPTER - II PLAIN AND REINFORCED CEMENT CONCRETE WORK.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size).
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Shelves (Cast-in-situ)
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Edges of slabs and breaks in floors and walls
Under 20 cm wide
Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing and laying cement concrete 1:6:12 (1 Cement : 6 coarse sand :12 graded brick aggregate 40 mm nominal size) in depressed portion of toilets, kitchen and balconies etc.
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
50 mm thick
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
CHAPTER - III BRICK WORK:
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
CHAPTER -IV WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Second class teak wood
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :
2nd class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
1.0 mm thick
Extra for providing lipping with 2nd class teak wood battens 35 x 6 mm minimum size on all edges of flush door shutters. 35 x 6 mm Teak wood beading
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs.
40 cm Long and embeddings in cement concrete block 30x10x15cm 1:3:6 mix (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
20 cm Long and embeddings in cement concrete block 20x10x15cm 1:3:6 mix (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA6 grade sleeve, including drilling of hole in frame, concrete/ masonry etc. as per direction of Engineer-in-charge.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing partly panelled and Glazed door shutter including ISI marked Stainless Steel butt hinges with necessary screws . Bottom panel with 3 ply 12 mm thick decorative type panelling & top panel with 5 mm thick float Glass all complete as per direction of Engineer-in-charge..
35 mm thick shutters.
Second class teak wood
Kiln seasoned and chemically treated hollock wood.
Providing and fixing wire gauge shutters using Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides, for doors, windows and clerestory windows with Stainless Steel butt hinges with necessary screws
35 mm thick shutters.
Second class teak wood
Kiln seasoned and chemically treated Hollock wood.
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of stainless steel lever handles with necessary screws etc. complete (best make of approved quality).
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing stainless steel Sliding door bolts of approved make, conforming to grade AISI-304 in 18/8 composition with nuts and screws etc. complete :
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing stainless steel tower bolts of approved make, conforming to grade AISI-304 in 18/8 composition with nuts and screws etc. complete :
Providing and fixing stainless steel handles of approved make, conforming to grade AISI-304 in 18/8 composition with nuts and screws etc. complete :
125 mm long and 10 mm Dia
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing Stainless Steel floor door stoppers of approved make, conforming to grade AISI-304 in 18/8 composition with nuts and screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw.
Providing and fixing stainless steel pull bolt lock of approved make, conforming to grade AISI-304 in 18/8 composition with nuts and screws etc. complete :
Supplying and fixing wood cupboards with 19mm thick commercial board for sides, tops, bottom/base and 6 thick mm commercial ply on back complete. The cupboard shutters will be 19 mm thick commercial board with 1.0 mm thick decorative lamination outside including IInd class 4 mm thick teak wood lipping / pvc lipping on edges including necessary screws and bright finished stainless steel piano hinges / self closing hinges , handles, door catchers, locks etc complete hardware as per direction of Engineer-in-charge. The inside portion including back surface shall be laminated with 0.8 mm thick white lamination . all complete.
600 mm deep
300 mm deep
Extra for providing drawers on channels in 600 mm deep cupboard
Providing and fixing 3 mm thick aluminium composite panel cladding of required size to Prelaminated Flush door shutter including fixing etc. complete as per direction of Engineer-in-charge.
Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete.
25 mm diameter
Providing and fixing Magic Eye of approved make, including nuts and screws etc. complete :
CHAPTER - V STEEL WORK
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: NOTE: Rate Should be Quoted Excluding M.S. pressed butt hinges 2.5mm thick.
Profile C
Fixing with adjustable lugs with split end tail to each jamb.
Profile E
Fixing with adjustable lugs with split end tail to each jamb.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing safety door made of stainless steel ( Grade 304) Hollow tubes, channels, plates , rod etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the door with necessary accessories i.e. SS hinges, SS wire gauge, handle, sliding door bolt , tower bolts and mortise lock etc. as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to openings / wooden frames with rawl plugs (designation 10 No.) etc., all complete
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
M.S. tube
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.
Made of G.I. wire of dia 4 mm
CHAPTER - VI FLOORING
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Area of slab over 0.50sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as white, Ivory, Grey, Fume, Red Brown, laid on 20mm thick cement mortar 1:4 ( 1cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.
Size300x300mm
Size 400x400mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 500x500 mm (Anti Skid)
Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 500x500 mm (Anti Skid)
Size of Tile 600x600 mm
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :
Udaipur green marble
Udaipur green marble stone in risers of steps, skirting, dado and pillars with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand ( Manufactured)) and jointed with grey cement slurry, including rubbing and polishing complete with :
Extra for pre finished nosing to treads of steps of marble stone.
Extra for marble stone flooring in treads of steps and risers using single length upto 2.00 metre.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Granite stone in risers of steps, skirting, dado and pillars with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand ( Manufactured)) and jointed with grey cement slurry, including rubbing and polishing complete with :
Extra for pre finished nosing to treads of steps of Granite stone.
Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre.
Extra for Providing Grooves in stone flooring in treads of steps
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
18 mm thick.
Providing and fixing glass strips in joints of terrazzo/ cement concrete floors.
40 mm wide and 4 mm thick
CHAPTER - VII ROOFING
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.
Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge.
Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.
The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
With average thickness of 120mm and minimum thickness at khurra as 65 mm.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.
IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including unplasticised - PVC moulded fittings/accessories to IS : 13592 Type jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. Inclusive of all fittings.
160 mm diameter
110 mm diameter
Providing 50 mm dia G.I. Spout set in cement mortar 1 : 3 (1 cement : 3 coarse sand) complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 20 cm x 20cm and weighing not less than 995 grams.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I
CHAPTER - VIII FINISHING
12 mm cement plaster of mix :
1:6 (1 cement : 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix
1:6 (1 cement : 6 fine sand)
6mm cement plaster of mix:
1:3 (1 cement : 3 fine sand)
Neat cement punning
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
20mm cement plaster
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.
Two or more coats on new work
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Applying priming coat :
With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
French spirit polishing :
Two or more coats on new works including a coat of wood filler
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing & fixing chicken wire mesh at the junctions of RCC and brick work, 100mm overlapping on both sides with all necessary hardware etc., complete.
CHAPTER -IX ALUMINUM WORK
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge.
Prelaminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4.0 mm thickness
With float glass panes of 5.50 mm thickness
With Stainless steel (grade 304) wire gauze of 0.5 mm dia wire mesh and 1.4 mm aperture on both sides.
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
Powder coated minimum thickness 50 micron aluminium.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With Stainless Steel cover plate minimum 1.25 thickness
Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
CHAPTER -X : SANITARY INSTALLATIONS
Providing and fixing coloured vitreous china pedestal type water closet (European type) with seat and lid, including 10 litre low level white vitreous china cistern with dual flush fitting, including seal cover and cistern fittings, nuts, bolts and gasket etc. complete with all fittings including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
White couple closet Jaquar model no. SLS-WHT 0318 /approved equivalent .
Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with CI brackets,15mm brass push type(pressmatic) pillar tap,32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. WB-Hindware model 10098 /approved equivalent.
White vitreous china wash basin flat back size 550 mm x 400 mm with single 15mm CP brass pillar tap.(Bottle trap-Jaquar model no. ALD 769/approved equivalent, CP waste-Jaquar model no. ALD 709/approved equivalent, pillar tap-Jaquar model no. 031/approved equivalent).
Providing and fixing coloured wash basin with CI brackets, Basin Mixture ,32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. W.B -Jaquar FLS - 0401 .
White vitreous china wash basin(round/oval under counter) size 580 mm x 430 mm with basin Mixture Mixer of Make Jaquar -FLR-5167B or Equivalent (Bottle trap-Jaquar model no. ALD 769/approved equivalent, CP waste-Jaquar model no. ALD 709/approved equivalent,).
Providing and fixing 5mm thick bevelled edge mirror of superior glass of approved quality and of required shape and size, fixed with teak wood beading / pvc of size 40x20mm with french spirit polish, 6mm thick water proof ply wood on back of the mirror etc. complete with two or more coats of black bituminous paint at the back of ply.
Providing & fixing in position C.P. brass twin coat hook including cutting necessary C.P. brass screws complete.(Jaquar model no. 1191N/approved equivalent).
Providing and fixing C.P. brass bib cock of approved quality conforming to IS : 8931.
15 mm nominal bore.(Jaquar model no. FLR - 5047 N /approved equivalent).
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms. (Jaquar model no. FLR-5047N /approved equivalent).
15 mm nominal bore.
Providing and fixing Stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required.
Kitchen sink with drain board
510 X 1040 mm bowl depth 250mm
Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete .
Flexible pipe
40 mm dia
Providing and fixing white vitreous china battery based infrared sensor operated urinal of appx. size 610x390x370mm having pre & post flushing with water (250ml & 500ml consumption)having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification & direction of Engineer-in charge with standard size C.P. brass flush pipe, spreader with unions & clamps(all in CP brass)including painting of fittings, cutting and making good the walls and floors where required. Hindware model 60018/approved equivalent.
Providing and fixing white vitreous china urinal of appx. size 610x410x380mm Hindware Model no 60002 /approved equivalent) with push type urinal flushing arrangement(Jaquar model no. 077 /approved equivalent)including fixing to wall with suitable brackets all as per manufacturers specification & direction of Engineer-in charge with standard size C.P. brass flush pipe, spreader with unions & clamps(all in CP brass)including painting of fittings, cutting and making good the walls and floors where required.
Providing & fixing urinal partition of 12 mm thk toughened glass ( size 675 x 330 mm) complete with brackets bolts nuts for grouting to wall complete in all respects.
Providing & fixing Hand Shower (Health Faucet) with 8mm dia, 1M long PVC tube and wall hook. (Jaquar model no. ALD-CHR-563/approved equivalent).
Providing and fixing toilet paper holder:(Jaquar model no. CAN-1151/approved equivalent).
C.P. brass
Providing and fixing 100mm CP brass grating for trap.
Providing & fixing in position C.P. brass towel rail (600mm long) including cutting necessary C.P. brass screws complete.(Jaquar model no. CAN-1111NM /approved equivalent).
Providing and fixing C.P. Brass towel ring (200 mm Dia ) including cutting necessary C.P. brass screws complete.(Jaquar model no. AQN-7721 Towel Ring Round /approved equivalent).
Providing & fixing in position CP soap dish.(Jaquar model no. 1131/approved equivalent).
Providing & fixing C.P. brass shower assembly Jaquar model no OHS-1789 consisting of wall mixer (Jaquar model no. FLR- 5273 UPR), wall flanges and shower rose (Jaquar SHA - 477) & pipe upto shower rose complete.
Providing & fixing Glass shelves of 12 mm thk toughened glass ( size 750 x 150 mm) complete with brackets bolts nuts for grouting to wall complete in all respects.
Providing & fixing Sink Mixer with Swinging Casted Spout (Wall Mounted Jaquar model FLR -5163 /approved equivalent) with 450mm long copper pipes & brass nuts.
Providing & fixing decorative six wall hook rack made from high quality/grade stainless steel of matt gloss surface finish including necessary C.P. brass screws complete.
CHAPTER - XI : WATER SUPPLY
Providing and fixing G.I. pipe (medium) complete with G.I. fittings and clamps, including cutting and making good the walls etc.
Internal work - Exposed on wall
15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c making good the walls etc. concealed pipe including painting with anti corrosive bitumastic paint, cutting chase and making good the wall.
15 mm dia. nominal bore
20 mm dia. nominal bore
25 mm dia. nominal bore
Providing and fixing brass stop cock of approved quality complete.
15 mm nominal bore
20 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work.
15 mm diameter pipe.
20 mm diameter pipe.
25 mm diameter pipe.
32 mm diameter pipe.
40 mm diameter pipe.
50 mm diameter pipe.
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)
15mm nominal bore
20mm nominal bore
25mm nominal bore
32mm nominal bore
40mm nominal bore
50mm nominal bore
65mm nominal bore
80 mm nominal bore
Providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931 a) 15 mm nominal bore. (Jaquar model no. FLR-5053 N /approved equivalent).
15 mm nominal bore
Providing and fixing unplasticised P.V.C connection pipe with PTMT Nuts collar and bush of approved quality and colour.
15mm nominal bore with 45cm length
Providing and placing on terrace (at all floor levels) Polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing in position storage type hot water electrical geyser( vertical or horizontal-1.5 kw) including making connection in all respects.-Venus/Racold or equivalent .
25 litres capacity.
CHAPTER - XII : DRAINAGE
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
100 mm inlet and 100 mm outlet
Sand cast iron S&S as per IS: 3989
Providing and fixing soil, waste and vent pipes.
100mm dia
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
Providing and fixing single equal plain junction of reqd. degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.
Sand cast (spun) iron pipe IS-3989
Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.
100 mm dia
Sand cast (spun) iron pipe S&S as per IS 3989.
Providing and fixing bend of required degree .
Sand cast (spun) iron pipe S&S as per IS 3989.
Providing and fixing collar.
Sand cast (spun) iron pipe S&S IS-3989
Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc.
For 100mm dia. Pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W./R.C.C. pipe including bed concrete as per standard design:
100mm diameter
Providing and laying 75mm thick (Average) cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) around CI soil and waste pipe under floor.
Painting G.I. Pipes and fittings with two coats of anticorrosive bitumastic paint of approved quality
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work
100mm dia cast (spun) iron S&S pipe
Providing and fixing G.I. Inlet fitting of suitable size with 2 & 3 Nos. G.I. Socket 32 & 40 welded G.I. pipe and dipped in hot bitumen complete in all respect.
100 mm diameter pipe (Hopper )
Providing lead caulked joints to sand cast iron/centrifugally cast(spun) iron pipes & fittings of diameter :.
Providing and fixing 100mm diameter C.P. Brass cleanout plug with M.S. flanged tail pieces, 6mm dia nut & bolts, gasket and washers fixed to C.I. Pipe with drip seal joint complete in all complete including cutting and making good the walls and floor wherever required.
with 100 mm dia. Pipe
Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design.
180x150mm size P type
with common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
CHAPTER - XIII : INTERNAL ELECTRIFICATION
SUBHEAD I - LIGHT POINTS
Point wiring for Light / fan / Exhaust fan with 2 runs of 1100V grade 1.5 sq. mm & 1 run of 1.5 sq. mm FRLS insulated multistranded Copper wires, run in & including 25 mm dia , heavy duty PVC conduits concealed in wall after necessary chase cutting with finishing / surface on wall/ ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends, elbows and ceiling rose, anodised GI switch box with modular switch and the box covered with front plate.
One light point controlled by one 6A switch
Two lights points controlled by one 6A switch
Three lights points controlled by one 6A switch
Four lights points controlled by one 6A switch
Five lights points controlled by one 6A switch
Six lights points controlled by one 6A switch
Exhaust fan point controlled by one 6A switch & ceiling Rose
Supply and wiring similar to item 1 above but for ceiling fan point including GI Box and controlled by one 6A switch, 100W step type Electronic regulator with Concealed MS fan hook box.
Call bell point with 6A Bell push with Buzzer
Supply and wiring for 6A socket outlet with 2 runs of 2.5 sq. mm FRLS insulated multistranded Copper wire and 1 run of 1.5 sq. mm FRLS insulated multistranded Copper earth wire in and including heavy duty 25 mm dia PVC conduit concealed in wall after necessary chase cutting with finishing / ceiling / below work stations along with required accessories, supply and fixing of 6A 3 Pin socket with 6A modular switch in anodized GI box and front plate complete with fixing accessories etc. as required.( Independent)
Supply and wiring for 2x 6A socket outlet with 2 runs of 2.5 sq. mm FRLS insulated multistranded Copper wire and 1 run of 1.5 sq. mm FRLS insulated multistranded Copper earth wire in and including heavy duty 25 mm dia PVC conduit concealed in wall after necessary chase cutting with finishing / ceiling / below work stations along with required accessories, supply and fixing of 6A 3 Pin socket with 6A modular switch in anodized GI box and front plate complete with fixing accessories etc. as required.( Independent)
Supply and wiring with the following size 1100V grade FRLS insulated multistranded Copper wires in and including suitable size heavy duty PVC conduit concealed in wall after necessary chase cutting with finishing / surface on wall / ceiling including all accessories such as junction boxes, bends elbows and end termination with suitable lugs.
2 Runs of 2.5 sq.mm wires with 1 Run of 1.5 sq.mm in 25 mm dia PVC conduit ( For circuit wirings)
2 Runs of 6 sq.mm wires with 1 Run of 6sq.mm in 25 mm dia PVC conduit ( For submain)
2 Runs of 10 sq.mm wires with 1 Run of 10sq.mm in 32 mm dia PVC conduit ( For submain)
4 Runs of 10 sq.mm wires with 2 Run of 10sq.mm in 40 mm dia PVC conduit ( For submain)
Supply installation testing and commissioning of TPN MCB Double door Distribution boards dust and vermin protected and rated for 415V Three Phase AC supply operation including incoming MCB/ ELCB / RCBO as per specifications and required capacity Neutral bar and Earth Terminal complete as required and installed in concealed in wall after necessary chase cutting with finishing / surface on wall including all fixing materials required. MCBs shall conform to IS : 8828 and ELCB shall conform to IS : 12640. All MCBs shall be "C" Curve.
8Way TPN-MCB DB with 40A, 4 Pole MCB as incomer and 24 Nos 6-25A SPMCBs as outgoing.(LDBs)
12Way SPN-MCB DB with 32A, DP MCB as incomer and 12 Nos 6-25A SPMCBs as outgoing.(LDBs)
6Way TPN-MCB DB with 125A, 4 Pole MCCB as incomer and 18 Nos 6-25A SP MCBs as outgoing.(LDBs)
8Way SPN-MCB DB with 32A, DP MCB as incomer and 8 Nos 6-25A SPMCBs as outgoing.(LDBs)
4Way SPN-MCB DB with 32A, DP MCB as incomer and 4 Nos 6-25A SPMCBs as outgoing.(LDBs)
LIGHT / FANS FIXTURES
Supply , installation, testing and commissioning of the following luminaries comprising of basic channel, holder, Electronic Ballast / Low Loss Copper Ballast starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specification and as per catalogue number giving below
1 x 30W Led ceiling surface type light fixture Philips Cat No. SM270C LED 30S 6500 PSU WH
1 x 32 w Led surface type mirror optic Philips Cat No. SM365C LED32-6500 PSU OD WH
1x18W Led -Wall bracket light fixture Philips cat- 45617/17 VASE
1x15 watt led -Ceiling light fixture Philips cat- SM-251 LED 16 S 6500 PSU WH
1x3.6watt led -Mirror light fixture -Philips cat- 34034/14/86
1x10W Led -Wall bracket bulk head light fixture Philips cat- WT -202-LED 6S NW PSU S-2 PC
1 x 20W Led wall bracket tube light Philips Cat No. BN 021C 20S-PSU - CW GR S-2
1x2W Led -Wall bracket brick light fixture Philips cat -30974
1x7 watt LED -Ceiling light fixture surface type Philips cat- SM-250 C-LED 7S 6500 PSU
1x7 watt LED - wall bracket light fixture type Philips cat- -34153
CEILING FANS
Supply and fixing of ceiling fan of 1200mm sweep ( white colour) suitable for operation on 230/240V, 50Hz, single phase, AC Supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete.
Supply and fixing of ceiling fan of 1400mm sweep ( white colour) suitable for operation on 230/240V, 50Hz, single phase, AC Supply complete with double ball bearing motor, required down rod, capacitor, three MS blades etc complete.
EXHAUST FANS
Supply, Installation & testing of following 900 RPM Exhaust fan suitable for suitable for single phase 230/240V, AC Supply complete with motor MS louvers , mounting brackets, all accessories etc as complete.
230mm dia Plastic body ventilation fan
381mm dia heavy duty exhaust fan
SUBHEAD II - : POWER WIRING
Supply and fixing of modular type single phase 16A 6 Pin shuttered type socket with 16A switch with front plate and anodized GI box including all fixing accessories.
Supply and fixing of single phase 1No 16A 6 Pin socket in GI box with 16Aswitch IN separate GI box, both of modular type with front plate compete as required ( Geyser Point)
Supply and fixing of modular type single phase 25A 3 Pin shuttered type socket with 25A switch with front plate and anodized GI box including all fixing accessories.( AC )
Supply and wiring with the following size 1100V grade FRLS insulated multistranded Copper conductor wires in and including suitable size heavy duty PVC conduit concealed in wall after necessary chase cutting with finishing / surface on wall / ceiling including all accessories such as junction boxes, bends elbows and end terminated with suitable lugs.
2 Runs of 4 sq.mm wires with 1 Run of 2.5 sq.mm in 25 mm dia PVC conduit ( For 16A Sockets & Geysers)
4 Runs of 4 sq.mm wires with 2 Run of 2.5 sq.mm in 25 mm dia PVC conduit ( For 16A Sockets & Geysers)
2 Runs of 6 sq.mm wires with 1 Run of 4sq.mm in 25 mm dia PVC conduit ( For 25A 1 Phase AC Sockets)
MV PANELS
Design, manufacture, supplying fixing in position, testing and commissioning of the following front operated modular compartmentalised construction cubicle type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors duly powder coated complete with incoming & outgoing MCCB's/MCB, aluminium busbars, interconnections, tinned copper crimping lugs, bonding to earth, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and panel shall have at least two spare cubicles to suit the highest rating outgoing MCB & suitable for a fault level of (25 KA) symmetrical at 415 volts.
All switchboards shall have provision for entry of cables from the top/bottom as required.
The cost shall include providing and fixing of 100 x 50 x 6 mm channels for switchboard support.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable OFF position
All MCCB shall have rotary handles & extension terminal, phase barrier on both sides as required at site.
All MDB / SDB panel shall be extendable type with cable alley.
All fault level braking capacity shall be Ics value (ICS = 100% ICU).
All MCCB shall have variable settings type.
Each meter compartment having 65x65x3mm thick acrylic sheet viewing windows and meter compartment having sealing arrangement, aluminium bus bars alley, interconnections with 25 sq.mm PVC insulated copper conductor cable, neon indicating lamps, including providing danger plate, painting and with followings switch gears etc. and connections crimped with Dowells make lugs/ferrules etc. as per specifications as required. The cubicle should have bottom and dividing box and top trunking boxes.
Main Metering panel - TYPE- II & III
1 Nos. 125Amp 25 KA 4 P MCCB complete with thermal magnetic release having over current, short circuit protection. incomer shall be complete with following.
3 Nos. Cast resin current transformers of 125/5 ratio Class 1.0 for metering.
Three phase indicating lamps (LED type) with MCB.
BUSBAR
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 125Amp having a maximum current density of .8 amp per sq.mm suitable to withstand symmetrical fault level of 25KA at 415 volts. The neutral busbar is to be of 100% capacity.
OUTGOING UNITS
12 Nos. 32 Amp, DP MCB 10KA
1 Nos. 6 Amp, DP MCB 10KA
13 No 5-30 A single phase direct reading energy meter housed in a 14 SWG MS sheet steel box with locking arrangement complete as require
Main Metering panel - TYPE- II & III
1 Nos. 100Amp 25 KA 4 P MCCB complete with thermal magnetic release having over current, short circuit protection. incomer shall be complete with following.
3 Nos. Cast resin current transformers of 100/5 ratio Class 1.0 for metering.
Three phase indicating lamps (LED type) with MCB.
BUSBAR
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 100Amp having a maximum current density of .8 amp per sq.mm suitable to withstand symmetrical fault level of 25KA at 415 volts. The neutral busbar is to be of 100% capacity.
OUTGOING UNITS
8 Nos. 32 Amp, DP MCB 10KA
1 Nos. 6 Amp, DP MCB 10KA
8 No 5-30 A single phase direct reading energy meter housed in a 14 SWG MS sheet steel box with locking arrangement complete as require
MV PANELS
Design, manufacture, supplying fixing in position, testing and commissioning of the following front operated modular compartmentalised construction cubicle type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors duly powder coated complete with incoming & outgoing MCCB's, aluminium busbars, interconnections, tinned copper crimping lugs, bonding to earth & panel shall have at least two spare cubicles to suit the highest rating outgoing MCB in suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of (25 KA) symmetrical at 415 volts.
All switchboards shall have provision for entry of cables from the top/bottom as required.
The cost shall include providing and fixing of 100 x 50 x 6 mm channels for switchboard support.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable OFF position
All MCCB shall have rotary handles & extension terminal, phase barrier on both sides as required at site.
All MDB / SDB panel shall be extendable type with cable alley.
All fault level braking capacity shall be Ics value (ICS = 100% ICU).
All MCCB shall have variable settings type.
Each meter compartment having 65x65x3mm thick acrylic sheet viewing windows and meter compartment having sealing arrangement, aluminium bus bars alley, interconnections with 25 sq.mm PVC insulated copper conductor cable, neon indicating lamps, including providing danger plate, painting and with followings switch gears etc. and connections crimped with Dowells make lugs/ferrules etc. as per specifications as required. The cubicle should have bottom and dividing box and top trunking boxes.
Main Metering panel -TYPE- V, IV
1 Nos. 100Amp 25 KA 4 P MCCB complete with thermal magnetic release having over current, short circuit protection. incomer shall be complete with following.
3 Nos. Cast resin current transformers of 100/5 ratio Class 1.0 for metering.
Three phase indicating lamps (LED type) with MCB.
BUSBAR
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 63Amp having a maximum current density of .8 amp per sq.mm suitable to withstand symmetrical fault level of 25KA at 415 volts. The neutral busbar is to be of 100% capacity.
OUTGOING UNITS
4 Nos. 40 Amp, 4P MCB 10KA
1 Nos. 6Amp, DP MCB 10KA
4no 10-60 A three phase direct reading energy meter housed in a 14 SWG MS sheet steel box with locking arrangement complete as require
1 No 5-30 A single phase direct reading energy meter housed in a 14 SWG MS sheet steel box with locking arrangement complete as require
Supply, installation, testing and commissioning of sectional -cubicle type dust & vermin proof main L.T. panel indoor mounting Powder coated, IP 42 made out of 2 mm thick CRCA sheet steel clad for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand fault level of 35 KA .The panel will be comprising with Incomer's, MCCB's Bus coupler switching, interlocking complete with following switchgear ( Main Panel Guest House )
1No. 250 Amp, 35KA, 4P with MCCB complete with Microprocessor based release having over current, short circuit, earth fault protection
1 set of R/Y/B LED Indicating lamps with control MCB for Incomers
BUSBAR
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 250Amp having a maximum current density of .8 amp per sq.mm suitable to withstand symmetrical fault level of 35KA at 415 volts. The neutral busbar is to be of 100% capacity.
OUTGOING UNITS
1No. 125 Amp, 25KA, TP with neutral link MCCB complete with Microprocessor based release having over current, short circuit, protection
4No. 63 Amp, 25KA, TP with neutral link MCCB complete with Microprocessor based release having over current, short circuit, protection
1No. 125 Amp, 25KA, TP with neutral link MCCB complete with Microprocessor based release having over current, short circuit, protection with controlling 16 nos 32 DP MCB including segrated Bus Bar .
SUBHEAD III - TELEPHONE / TV WIRING
Supply and laying of 25mm dia, heavy duty PVC conduit concealed in wall / ceiling / floor including all accessories such as Junction boxes, conduit bends, etc. completed as required for Telephones / TV etc.
Supply and laying of 32mm dia, heavy duty PVC conduit concealed in wall / ceiling / floor including all accessories such as Junction boxes, conduit bends, etc. completed as required for unarmoured Telephones cable etc.
Supply and fixing of Telephone outlet(RJ11) with anodised GI box with front plate.
Supply and fixing of TV outlet with anodised GI box with front plate.
Supply and fixing of computer outlet/data point outlet(RJ 45) with anodised GI box with front plate.
Supply and laying of 2 pair 0.6mm dia PVC insulated unarmoured copper conductor Telephone wire conforming to DOT Specifications
Supply and laying of RG 6 Cable in existing conduit
Supply and laying of cat - 6- gaga speed Cable in existing conduit
Supply and installation of following size TV Splitter in MS box complete as required.
Splitter- 4 Way
Supply and installation of following size Krone connectors in MS box complete as required.( hensel make )
Supply and laying of 80 mm dia. Class "B" GI pipes laid 600mm below ground level including excavation, back filling etc., complete.
Supply and laying of 40 mm dia. Class "B" GI pipes in PCC foundation for TV & telephone etc., complete.
SUBHEAD IV - EARTHING
EARTHING
TAPES/WIRES
Supplying, fixing, jointing, and terminating of the following tapes/wires in masonry trenches/on walls/on cable tray/ along the cable with suitable G.I./Copper Clamps, screws etc. The wire shall be terminated with proper sockets, washers, bolts & nuts. All joints shall be rigid using double rivets :
25 x 6 mm GI Tape
EARTH STATIONS:
Providing and fix following earth station as per IS 3043-1987, with 32mm dia GI watering pipe, GI funnels masonry chamber of size 450 x 450 x 300 mm depth with hinged CI cover having locking facility, Including excavation and refilling of pit, supplying and fixing of charcoal salt & sand, identification of pit as per required.
600 x 600 x 6 mm GI Plate Earth Station
CHAPTER - XIV : ROAD & HARD STANDING
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
Cement concrete prepared with batch mixing machine
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer--in-charge.
cautionary / Warning sign boards of equilateral triangular shape having each side 900mm with support length of 3650 mm.
Providing & applying 2.5mm thick road marking strips (retro-reflective) of specified shade / colour using hot thermoplastic material by fully / semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour , T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge. and accordance with applicable specifications.
Providing and fixing in position pre-moulded joint filler in expansion joints.
Providing 5mm wide and 15mm deep joints in rigid pavements, first 5mm portion filled with polysulphide sealant and remaining portion with foam and tape etc. all complete.
Providing and laying Polythene sheet (400 micron thick) conforming to IS :2508 antifriction layer on the sub base course complete as per specifications.( Overlaps at joints of pvc sheet should be 100 mm wide )
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
300 mm dia RCC pipes.
450 mm dia RCC pipes.
600 mm dia RCC pipes
CHAPTER - XV : EXTERNAL WATER SUPPLY
Providing and fixing G.I. pipes(medium) complete with G.I. fittings including trenching and refilling etc.
20 mm dia nominal bore.
25 mm dia nominal bore.
32 mm dia nominal bore.
40 mm dia nominal bore.
50 mm dia nominal bore.
65 mm dia nominal bore.
80 mm dia nominal bore.
Providing and fixing G.I. pipes(medium) complete with G.I. fittings conforming to IS-1239 with all accessories like all fittings including tees, elbows, reducers, flanges, rubber gaskets, nuts bolts, washer & fixing the pipe on floor / wall /ceiling with suitable size clamps, hangers, structural steel supports, cutting holes and chases in brick, R.C.C work and making good the same to original conditions complete in all respects.
100 mm dia nominal bore.
150 mm dia nominal bore.
Providing and fixing gun metal gate valve of approved quality (screwed end):
65 mm nominal bore
Vertical
Providing and fixing CI sluice valves(with cap) complete with bolts, nuts, rubber insertions etc.(the tail pieces if required will be paid separately).
100 mm diameter
Class II
150 mm diameter
Class II
Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter,160 mm bottom diameter and 180mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design.
a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter,160 mm bottom diameter and 180mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design.
a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Supply, erection, testing and commissioning of air release Valves flanged end complete with bolts, nuts, and rubber insertions and of 25 NB size.
Providing and fixing CI non return valve complete with bolts, nuts, rubber insertions etc.
100 mm diameter
150 mm diameter
Providing & wrapping G.I. pipes(medium) and fittings with 4mm thick pypcoat all around the pipe in external work.
20 mm dia nominal bore.
25 mm dia nominal bore.
32 mm dia nominal bore.
40 mm dia nominal bore.
50 mm dia nominal bore.
65 mm dia nominal bore.
80 mm dia nominal bore.
CHAPTER - XVI : EXTERNALSEWAGE DISPOSAL
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:
150 mm dia. R.C.C. pipe
250 mm dia. R.C.C. pipe
300 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
150 mm diameter S.W. pipes
250 mm diameter S.W. pipes
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard design:
150 mm diameter S.W. pipes
250 mm diameter S.W. pipes
300 mm diameter S.W. pipes
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size ) inside plastering 12 mm thick with cement mortar 1:3 (1 Cement : 3 coarse sand) finished with floating coat of neat cement & making channels in cement concrete 1:2:4(1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Inside size 90x80cm and 45cm deep including C.I. cover with frame (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg)
With common burnt clay FPS (non modular) bricks of class designation 7.5
Inside size 120x90cm and 90cm deep including C.I. cover with frame (medium duty) 500mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg)
With common burnt clay F.P.S(non modular) bricks of class designation 7.5
Extra for depth for manholes
Size 90x80 cm
With common burnt clay FPS (non modular) bricks of class designation 7.5
Size 120x90cm
With common burnt clay FPS (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4(1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete all complete as per standard design:
1.68 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid separately)
With common burnt clay FPS (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29m
With common burnt clay FPS (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.52m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete all complete as per standard design:
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :
With common burnt clay FPS (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30m
With common burnt clay FPS (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263mm and width as 165mm with minimum 112 mm space between protruded legs having 2mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistant test as per specification and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manhole with 30x20x15 cm cement concrete block 1:3:6 (1cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidated each deposited layer by ramming, watering, etc. and disposing of surplus excavated soils directed, within a lead of 50m.
All kinds of soil
Pipes, cables etc. exceeding 80mm dia. but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) including 500x450mm pre-cast R.C.C. horizontal grating with frame complete as per standard design:
With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) with pre-cast R.C.C. vertical grating complete as per standard design:
With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 ( 1 cement :4 coarse sand) including 500x450mm pre-cast R.C.C. horizontal grating with frame & vertical grating complete as per standard design:
With common burnt clay F.P.S.(non-modular) bricks of class designation 7.5.
Provision of Rain Water Harvesting Tank of internal diameter 3.0m x 2.5 m liquid depth including the Excavation, P.C.C. 1:3:6, R.C.C. M25 in foundation, walls and slabs, Fe-500 TMT Reinforcement, PVC in capsulated orange colour foot rest, R.C.C. Precast manhole cover, Boring/drilling bore well of 300mm dia for casing/ strainer pipe, supplying, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of 200mm dia, Stone boulders of size range 5 cm to 20 cm in the layer of 300mm thick, Gravels of size range 5 mm to 10 mm in the layer of 300mm thick over the existing layer of boulders, coarse sand of size range 1.5 mm to 2 mm in recharge pit, in the layer of 400mm thick over the existing layer gravel layer, and Welded steel wire fabric of required width rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer. The work shall be done as per drawings and as directed by the Engineer-in-charge.
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
CHAPTER - XVII: EXTERNAL ELECTRIFICATION WORK
Earthing for body
Supply, Installation of long life Maintenance Free Earthing System. The Rod shall be of Copper Bonded Steel with 17.2 mm dia. and 10 feet length with a core of mild steel molecularly bonded with min. 250 microns coating of 99.99% pure electrolytic grade Copper and exothermically welded Cu Busbar of 50X6X200mm both tested by CPRI capable of bearing fault current of 25 kA. Along with earth enhancement compound tested by RoHs complying IEC 62561-7 in a sealed bag of minimum 30 kg (10 kg Bag x 3) resistivity is less than 0.2 ohm meter . The earthing shall be with Suitable Poly-plastic Pit Cover with lockable arrangement( JMV/ERICO)
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
CABLE , END TERMINATIONS & CABLE TRAY
Laying of the following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench / already laid RCC Hume pipe or on cable tray / through GI pipe with all installation materials. When the cable is to be laid in ground, the same shall be laid at a depth of 750 mm below ground level including excavation and refilling of earth after cables are laid, providing sand cushioning and protection with bricks at sides and top and cable route markers at every 50 mtr. interval and also at the turnings. The cable shall conform to IS 7098/ Part I.
3.5 core 300 sq. mm. Alu XLPE (Above 185 sq.mm and upto 400 sq.mm )
Laying in ground
Laying in Trench / cable tray / GI Pipe
3.5 core 240 sq. mm. Alu XLPE (Above 185 sq.mm and upto 400 sq.mm )
Laying in ground
Laying in Trench / cable tray / GI Pipe
3.5 core 70 sq. mm. Alu XLPE (Above 35 sq.mm and upto 95 sq.mm )
Laying in ground
Laying in Trench / cable tray / GI Pipe
3.5 core 50 sq. mm. Alu XLPE (Above 35 sq.mm and upto 95 sq.mm )
Laying in ground
Laying in Trench / cable tray / GI Pipe
Supply testing and commissioning of the following size 1.1KV grade XLPE insulated armoured aluminium conductor under ground cable, in built up cable trench / already laid RCC Hume pipe or on cable tray / through GI pipe with all installation materials.
3.5 core 300 sq. mm. Alu XLPE
3.5 core 240 sq. mm. Alu XLPE
3.5 core 70 sq. mm. Alu XLPE
3.5 core 50 sq. mm. Alu XLPE
Providing end terminations for the cable specified below with Double compression type gland, Bi-Metallic lugs using crimping tool, Insulation tape, Identification tags etc. including end termination.
3.5 core 300 sq. mm. Alu XLPE
3.5 core 240 sq. mm. Alu XLPE
3.5 core 70 sq. mm. Alu XLPE
3.5 core 50 sq. mm. Alu XLPE
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.
100mm dia
150 mm dia
250 mm dia
Supply, Installation, testing and commissioning of following outdoor type Feeder Pillar with relevant IP 54 and suitable for 415 volts, 3 phase, 4 wire and 50HZ AC power supply totally enclosed compartmentalized, fabricated with 2 mm thick sheet, complete with aluminium bus bars (both for main and neutral), incoming/outgoings, cable terminations, inter-connections, indication lamps, pedestal frame on RCC foundation/platform of 300 mm height above GL, necessary earth connections conforming to relevant IS codes, specification and drawings. - FP13
INCOMING :
1 No. 400Amp, 35KA,4 P MCCB complete with thermal magnetic release having over current, short circuit, protection with
1 set of three R Y B indicating lamps.
BUSBAR
Electrolytic high conductivity aluminium three phase and neutral bus bars rated at 400Amp throughout having a maximum current density of 0.8 amp per sq mm suitable to withstand symmetrical fault level of 35 MVA at 415 volts. The neutral bus bar is to be of 50% capacity.
OUTGOING
6 Nos 125Amp, 25KA,TPN MCCB complete with thermal magnetic release having over current, short circuit, protection with
Supply, Installation, testing and commissioning of following outdoor type Feeder Pillar with relevant IP 54 and suitable for 415 volts, 3 phase, 4 wire and 50HZ AC power supply totally enclosed compartmentalized, fabricated with 2 mm thick sheet, complete with aluminium bus bars (both for main and neutral), incoming/outgoings, cable terminations, inter-connections, indication lamps, pedestal frame on RCC foundation/platform of 300 mm height above GL, necessary earth connections conforming to relevant IS codes, specification and drawings. - FP10
INCOMING :
1 No. 400Amp, 35KA,4 P MCCB complete with thermal magnetic release having over current, short circuit, protection with
1 set of three R Y B indicating lamps.
BUSBAR
Electrolytic high conductivity aluminium three phase and neutral bus bars rated at 400Amp throughout having a maximum current density of 0.8 amp per sq mm suitable to withstand symmetrical fault level of 35 MVA at 415 volts. The neutral bus bar is to be of 50% capacity.
OUTGOING
8 Nos 125Amp, 25KA,TPN MCCB complete with thermal magnetic release having over current, short circuit, protection with
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including dismantling the existing MCCB in panel & feeder pillars , drilling holes in cubicle panel, making connections, etc. as required.
400 A, 35 KA,TPN MCCB
125 A, 25 KA,TPN MCCB
Supply, installation, testing and commissioning of sectional -cubicle type dust & vermin proof main L.T. panel extensible type indoor mounting Powder coated, IP 42 made out of 2 mm thick CRCA sheet steel clad interconnected with L.T panel of existing bus coupler for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand fault level of 50 KA .The panel will be comprising with Incomer's, ACB's Bus coupler switching, interlocking complete with following switchgear Transformer incoming (1 No.) each equipped with 1 No 1600mp 415 volt grade, 50 kA electrical operated draw out 4P ACB (EDO) with inbuilt overload protection with time delay, short circuit protection with time delay and instantaneous along with earth fault protection complete with.
Shunt trip coil 24 V DC and under voltage coil 230 V AC.
Safety shutter & 6 NO + 6 NC contacts.
3 nos cast resin current transformer of 1600A/5 (for 1000 KVA TRF) ratio class 1.0 for metering, 15 VA Burden.
1 set of three R Y B indicating lamps.
Red / green / amber ON / OFF / Trip indicating lamps.
Illuminated push button for healthy circuit.
1-CT epoxy cast 1600A/5 15 VA Burden for APFC relay.
Terminal to receive 1600Amp - TPN AL BUS TRUCKING
1 No Digital solid multifunction meter for KV, Amp., KW, KVAr, KVA, KWH, KVAH, KVArh, P.F. Amp-h, HZ measurements. With communication port -RS-485
1No. Master trip relay
1No. Trip circuit supervision relay
Under voltage relay – 415 V AC.
Over voltage relay – 415 V AC
BUSBAR
Electrolytic high conductivity aluminium three phase and neutral bus bars rated at 1600Amp throughout having a maximum current density of 0.8 amp per sq mm suitable to withstand symmetrical fault level of 50KA at 415 volts. The neutral bus bar is to be of 50% capacity.
Space for bus coupler for 1600Amps EDO ACB
INTERLOCKING
The Bus section and Incoming ACB's shall be electrically interlocked with the sequence of operation, in case of manual override mode.
OUTGOING UNITS
SECTION-II
1 No 800mp 415 volt grade, 50 kA MDO draw out 4P ACB with inbuilt overload protection with time delay, short circuit protection with time delay and instantaneous along with earth fault protection complete
1 Nos. 630 Amp, 50KA, TP with neutral link MCCB complete with thermal magnetic release having over current, short circuit, protection
7 Nos. 400 Amp, 50KA, TP with neutral link MCCB complete with thermal magnetic release having over current, short circuit, protection
1 Nos. 250Amp, 35KA, TP with neutral link MCCB complete with thermal magnetic release having over current, short circuit, protection
1 Nos. 125 Amp, 35KA, TP with neutral link MCCB complete with thermal magnetic release having over current, short circuit, protection
5 Nos. 100Amp, 35KA, TP with neutral link MCCB complete with thermal magnetic release having over current, short circuit, protection
CHAPTER - XVIII : EPABX System
Supply, Installation, testing and commissioning of 300 pairs MDF Box, Mounting Frame with Krone Module of telephone outdoor type Feeder Pillar with relevant IP and totally enclosed compartmentalized, fabricated with 2 mm thick sheet, complete with KRONE make telephone tag block, incoming & out goings, cable terminations, interconnections, pedestal frame on RCC foundation/platform of 300 mm height above GL, necessary earth connections conforming to relevant IS codes, specification and drawings.
Supply, Installation, testing and commissioning of 500 pairs MDF Box, Mounting Frame with Krone Module of telephone outdoor type Feeder Pillar with relevant IP and totally enclosed compartmentalized, fabricated with 2 mm thick sheet, complete with KRONE make telephone tag block, incoming & out goings, cable terminations, interconnections, pedestal frame on RCC foundation/platform of 300 mm height above GL, necessary earth connections conforming to relevant IS codes, specification and drawings.
Supply, of 50 Pair JFC Riser cable multi core 0.61 mm annealed tinned copper conductor PVC insulated and PVC sheathed and jelly filled and overall PVC sheathed armoured telephone cables generally conforming to ITD S/WS-11-C and IS 1554 Part as per specification complete as required
Supply, of 300 Pair JFC Riser cable multi core 0.61 mm annealed tinned copper conductor PVC insulated and PVC sheathed and jelly filled and overall PVC sheathed armoured telephone cables generally conforming to ITD S/WS-11-C and IS 1554 Part as per specification complete as required
Supply, Installation, Testing & Commissioning of EPABX System * 200 Nos. Analogue extensions with Caller ID. Expandable upto 1000 Lines To ensure long distance connectivity, minimum loop resistance should be 1800 ohms. * Digital extensions for digital feature phones (2 wire) * Analogue trunk lines with Caller ID (DTMF or FSK) * CLI facility for all users should be provisioned from day 1. * The system shall capable of operating with the following units: Dial Pulse (DP) telephone devices, DTMF telephone devices, Digital telephone devices, Analogue telephone devices, IP telephone devices, Wi-Fi telephone devices, IP Video Phone, Soft Phone (software based telephone) applications, Other Telephone Exchanges (PABX), ISDN PRI 2 Mbps (E1) Network, and 4 wired Continuous and Discontinuous E&M circuits, Internal portable hand type telephone device systems (DECT standard), Facsimile devices, Data extensions, Voice Mail System, Smart mobile phones, Tablets and computers.
Supply, Installation, testing and commissioning of 300 pairs MDF Box, Mounting Frame with Krone Module of telephone outdoor type Feeder Pillar with relevant IP and totally enclosed compartmentalized, fabricated with 2 mm thick sheet, complete with KRONE make telephone tag block, incoming & out goings, cable terminations, interconnections, pedestal frame on RCC foundation/platform of 300 mm height above GL, necessary earth connections conforming to relevant IS codes, specification and drawings.
(Above 100 Pair upto 300 pair )
Laying in ground
Laying in Trench / cable tray / GI Pipe
(Above 25 Pair upto 50 pair )
Laying in ground
Laying in Trench / cable tray / GI Pipe
CHAPTER - XIX: ARBORICULTURE
AVENUE TREE PLANTATION.
Digging of pits of size 1.0M x 1.0 M x 1.0 M, in any type of soil. Refilling of pits with a mixture of good earth and cow dung organic manure in the ratio 3:1 (Three part of good earth and one of organic manure). Flooding the pit with water so that the earth manure mixture settles down. Supply and plantation of approved variety of tree sapling, disease free, healthy, fully established 1-2 years old with well developed root system in the centre of pit with a clear minimum height of 4 ft, after the plantation, proper watering and caring for 30 days regularly as the minimum guarantee period. (Variety : Azadirachta Indica (Neem) / Callislemon Lanceolatus (Bottle Brush) / Dalbergia sissoo / Pangomia / Gulmohar / Ashoka Pendula / Champa / Casia semia / Peltaphourm Equi). Maintenance includes, regular watering, de-weeding. Spray of insecticide and fungicide as and when required for a peirod of one month.
(Good earth if required additionally will be paid for separately on actual measurement basis after the deduction of 20% of its volume for porosity)
SHRUB PLANTATION IN PITS/BEDS
Digging of beds of size 60 cms depth in any type of soil. Refilling the pits with a mixture of good earth and cow dung organic manure in the ratio of 3:1 (Three parts of good earth and one part of Organic manure). Flooding the beds with water so that the earth and manure mixture settles down in pits. Supply and plantation of approved shrub species sapling at 1.5 ft - 2 ft spacing of good quality, disease, free, healthy, fully established 1-2 years old with well developed root system and with a clear minimum height of 1 feet after plantation. Watering it for 30 days regularly as the minimum guarantee period (Corton/chandani/Ixzora/Rose Varieties/ Casia bi flora/calandera / Acalypha.
Bougainvellia/Hibiscus/Naruium/jatropha/Ficus Panda Equi.).
(Good earth if required additionally will be paid for separately on actual measurement basis after the deduction of 20% of its volume for porosity)
LAWN DEVELOMENT
Excavation in any type of soil removal of small stones, pebbles, brick or boulders and stacking them at site for measurement. Refilling of dugout area with good earth (to be measured and paid for separately) and dressing up the area as directed by Engineer-in-Charge. Removal and disposal of stacked material to a distance upto 3 Kms with all leads and lifts etc. complete by mechanical transport, loading, uploading, royalty all complete.
All kinds of soil
(Good earth if required additionally will be paid for separately on actual measurement basis after the reduction of 20% by its volume for its porosity).
HEDGE PLANTATION
Digging of trenches of size 60 cms x 45 cms x running mts length in all type of soil. Rest all the item are same as in item No.3 of shrubs ,plantation except that the minimum 07 number of hedges sapling should be planted per running metre(Clerodondroninerme/ Putranjeeva/Golden Durenta Equi)
GROUND COVER:
Digging upto 0.3m, refilling with agriculture soil and cattle manure in 4:1 ratio. Provision of anti termite treatment at plantation time. Maintenance includes ,regular watering, dee weeding. Pruning and spraying of insecticides and fungicide as and when required for a period of one month.
(Good earth if required additionally will be paid for separately on actual measurement basis after the reduction of 20% by its volume for its porosity).
PVC Planter Box. Supply of PVC planter box with tray suitable for 12" to 14" size earthen pots.
Potted Plants. Supply and maintaining the Indoor and outdoor potted plants in a good, healthy and disease free condition of various varieties and in different type of pots. Maintenance includes, regular watering, de-weeding. Spray of insecticide and fungicide as and when required for a period of one month.
Supply of good earth suitable for any type of plantation at the site including royalty and carriage. Development of mounds with sweet earth as per the required levels as per direction of Engineer - in - charge. (Agriculture Soil)
RMS CONSTRUCTION PVT. LTD.
C S CONSTRUCTION COMPANY PVT. LTD.
S. R. ASHOK & ASSOCIATES PVT. LTD.
RIC Projects Pvt. Ltd.
Vishal Infrastructure Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid