| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.5 Cr+₹15 L (10.8%)Rejected-Finance | ₹1.5 Cr+₹15 L (10.8%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.6 Cr+₹18.1 L (13.0%)Rejected-Finance | ₹1.6 Cr+₹18.1 L (13.0%) | L3 | Rejected-Finance Other than L1 |
| 4 | Rejected-Technical 346 NEAR SANJAY VATIKA WARD NO 4 PURANI ABADI SRIGANGANAGAR RAJASTHAN 335001 | SRIGANGANAGAR | SRIGANGANAGAR | RAJASTHAN | 335001 | - | - | Rejected-Technical Non compliant as per eligibility criteria. |
| 5 | Rejected-Technical 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | - | - | Rejected-Technical Non compliant as per eligibility criteria. |
| Sl No | Description | Qty | Unit | M/S RK STEEL L3 | FUJI SILVERTECH CONCRETE PRIVATE LIMITED L1 | FUJI INFRASTRUCTURE TECHNOLOGIES PVT LTD L2 |
|---|---|---|---|---|---|---|
| 1.00The bidder is required to quote lump sum price for the work listed in the BOQ document individually and the total cost of all the items would be taken for deriving the L1 bidder. | ||||||
| 1.01 | Scope of Constr in General. The scope of the work includes construction (EPC mode) of underground Protected Facility in out-to-out dimension of 12.00 x 7.00 x 3.00 mtr of internal clear height along with the living facilities. The UG Facility construction includes design, manufacture, supply and fitting of High Strength Precast Reinforced (HSPR) Boxes of size 3000 mm x 3000 mm x 1000 mm with 250 mm wall thickness and 300 mm Slab & 250 mm raft thickness. The complete UG facility will have one entry/ exit which comprises of Precast L-Shape Retaining wall for side protection of 4000 mm (Height) x 2650 mm (Leg Width) x 1500 mm Segment length in quantity of 5 Nos and 2500 (Height) x 2150 mm (Leg Width) x 2000 mm Long in quantity of 02 Nos. A Precast FT Lid of dimension 1600 x 1000 in mm in quantity 2 Nos. is required to be provided as shed cover at entry and exit. The UG facility entry/ exit will have precast RCC Staircase of 800 mm stair width, 2750 mm flight length, Riser of 150 mm and Trade of 220 mm each in quantity of 02 Nos. This will contain FT Lid of Size 1600 x 1000 mm - 01 No as landing support including false ceiling, electric supply, water supply, sanitary fittings, plumping works, furniture, HVAC electrical work and adequate sewages works etc complete all as per conceptual drawings and attached. Internal doors cut out of size 900 mm wide and 2100 mm Height each in Precast Bunker box arrangement for internal movement. The facility would provide adequate and prolonged protection from Small Arms Fire, direct hits of multiple130 mm Field Arty and multiple indirect hits of 155 mm Medium Artillery. The overall facility with an overhead protection of 1m of earthwork would have enhanced protection over and above as defined. internal/external electric supply, sanitary fittings, plumping works, furnitures, work and adquate sewage works etc complete all as per conceptual drawings and attached. internal doors cut out of size 900mm wide and 2100mm Height each in Precast Bunker box arrangement internal movement. The facility would provide adequate and prolonged protection from Small Arms Fire, direct hits of multiple 130mm Field Arty and multiple indirect hits of 155mm Medium Artillery. The overall facility with an overhead proction of 1m of earthwork would have enhanced protection over and aboce as defined.
Each open end of the Box will be closed with metal plate of 20 mm Thick MS Plate of Size 3000 x 3000 mm (LXB) in 4 Nos for four open ends. The frame will be fitted with internal jointed metal frame support as complete protection against water seepage and any kind of vibrations.
Note:- Design for Over Head Protection loads to be vetted by structural designer and IIT, services design and plan to be submitted through MEP consultant, Architectural drawing to be submitted through Architect, design detailing and cost to be borne by the successful bidder. Tentative conceptual drawings are attached for reference. A certificate from the designer for the structure to be seepage and dampness proof to be submitted by the successful bidder. In addition, the successful bidder will also provide detailed drawings of mechanical, electrical, plumbing, site survey etc within 10 days of award of Contract. | 1 | Nos | 1,57,05,000 ₹1,57,05,000 | 1,39,00,000 ₹1,39,00,000 Lowest | 1,54,00,000 ₹1,54,00,000 |
Tender Value
₹1.5 Cr
EMD Value
₹4.5 L
Closing Date
5 Nov 2025, 6:00 pmClosed
CO 115 Engr Regt
115 Engr Regt
SUPPLY and CONSTRUCTION OF RELOCATABLE MODULAR UG COMD AND CONTROL CENTRE (QTY 01)
2025_ARMY_736206_1
9124/RFP/25-26/OP WKS (S andC)
Open Tender
Civil Works
Lump-sum
60 days
Jaipur
As per RFP document
8 documents required · 8 mandatory
₹0
₹4.5 L
5 Dec 2025
21 Oct 2025
7 Nov 2025
21 Oct 2025
5 Nov 2025
28 Oct 2025
Amount
The bidder is required to quote lump sum price for the work listed in the BOQ document individually and the total cost of all the items would be taken for deriving the L1 bidder.
Scope of Constr in General. The scope of the work includes construction (EPC mode) of underground Protected Facility in out-to-out dimension of 12.00 x 7.00 x 3.00 mtr of internal clear height along with the living facilities. The UG Facility construction includes design, manufacture, supply and fitting of High Strength Precast Reinforced (HSPR) Boxes of size 3000 mm x 3000 mm x 1000 mm with 250 mm wall thickness and 300 mm Slab & 250 mm raft thickness. The complete UG facility will have one entry/ exit which comprises of Precast L-Shape Retaining wall for side protection of 4000 mm (Height) x 2650 mm (Leg Width) x 1500 mm Segment length in quantity of 5 Nos and 2500 (Height) x 2150 mm (Leg Width) x 2000 mm Long in quantity of 02 Nos. A Precast FT Lid of dimension 1600 x 1000 in mm in quantity 2 Nos. is required to be provided as shed cover at entry and exit. The UG facility entry/ exit will have precast RCC Staircase of 800 mm stair width, 2750 mm flight length, Riser of 150 mm and Trade of 220 mm each in quantity of 02 Nos. This will contain FT Lid of Size 1600 x 1000 mm - 01 No as landing support including false ceiling, electric supply, water supply, sanitary fittings, plumping works, furniture, HVAC electrical work and adequate sewages works etc complete all as per conceptual drawings and attached. Internal doors cut out of size 900 mm wide and 2100 mm Height each in Precast Bunker box arrangement for internal movement. The facility would provide adequate and prolonged protection from Small Arms Fire, direct hits of multiple130 mm Field Arty and multiple indirect hits of 155 mm Medium Artillery. The overall facility with an overhead protection of 1m of earthwork would have enhanced protection over and above as defined. internal/external electric supply, sanitary fittings, plumping works, furnitures, work and adquate sewage works etc complete all as per conceptual drawings and attached. internal doors cut out of size 900mm wide and 2100mm Height each in Precast Bunker box arrangement internal movement. The facility would provide adequate and prolonged protection from Small Arms Fire, direct hits of multiple 130mm Field Arty and multiple indirect hits of 155mm Medium Artillery. The overall facility with an overhead proction of 1m of earthwork would have enhanced protection over and aboce as defined. Each open end of the Box will be closed with metal plate of 20 mm Thick MS Plate of Size 3000 x 3000 mm (LXB) in 4 Nos for four open ends. The frame will be fitted with internal jointed metal frame support as complete protection against water seepage and any kind of vibrations. Note:- Design for Over Head Protection loads to be vetted by structural designer and IIT, services design and plan to be submitted through MEP consultant, Architectural drawing to be submitted through Architect, design detailing and cost to be borne by the successful bidder. Tentative conceptual drawings are attached for reference. A certificate from the designer for the structure to be seepage and dampness proof to be submitted by the successful bidder. In addition, the successful bidder will also provide detailed drawings of mechanical, electrical, plumbing, site survey etc within 10 days of award of Contract.
FUJI INFRASTRUCTURE TECHNOLOGIES PVT LTD (BID ID -3467342)
M/S RK STEEL (BID ID -3467502)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
RFP1.pdf
Tender Documents • 10.12 MB
BOQ_824324.xls
BOQ • 0.75 MB
drawings.pdf
Additional Documents • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .