3 Aug 2021, 5:00 pmClosed
Executive Engineer Jal Shakti Divn No.1 Una HP
Executive Engineer Jal Shakti Divn No.1 Una HP
Providing Water Supply Scheme to newly settled abadies of village Bathu( Gurplah) Distt. Una (HP). (SH C/O Pump House cum chokidar qtr. Boundary wall around the pump house cum chowkidar qtr. and internal wiring, C/o RCC storage Tank 325000 ltrs etc
2021_HPIPH_50156_1
No. JSV-1/TA/E-tender/21- 4552-81 dt 20-07-2021
Open Tender
Civil Works
Item Rate
365 days
Bathu (Gurplah)
as per NIT
8 documents required · 8 mandatory
₹400
Yes
Executive Engineer Jal Shakti Divn No.1 Una HP
₹57,608
Yes
5 Aug 2021
20 Jul 2021
4 Aug 2021
20 Jul 2021
3 Aug 2021
20 Jul 2021
20 Jul 2021 - 3 Aug 2021
Amount
Excavation in foundation, trenches in earth work in all kinds of soil,such as pick work,jumper work.blasting work in hard rock and soft rock and in saturated soil etc. i/c all leads and lifts , stacking the excavated soil not more than 3 mtrs. clear form the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth, sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated earth as per the direction of the Engineer-in-Charge.
Providing and laying cement concrete 1: 6: 12 ( 1 cement : 6 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts and as per the direction of the .Engineer-in-Chaarge.
Ist class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 ( 1 cement: 6 sand ) in all leads and lifts as per the direction of the Engineer-in-Charge.
Ist class brick work using common burnt clay building bricks in superstructure in cement mortor 1:6 (1 cement :6 sand) in all lead and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing pressed steel door frame manufactured from commercial MS sheets of 1.25 mm thickness including hinges jump lock jamb, bead if required angle thrshold of MS angle of section 50x25 mm or base ties of 1.25 mm presses MS welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamb including steel butt hinges 2.5 mm thick with guards, lack strike plate and shock absorberas specified and applying a coat of approved steel primer after pretreatment of the surface as directed by Engineer-in-Charge.
Profile "A"
Profile "B"
Providing and fixing pannelled glazed and panalled and glazed shuttrs for doors ,windows and clerestory windows including bright finshied /black enemelled iron butt hinges with necessary screws 40 mm thick. 2 nd class deodar wood complete in all respect and as per the direction of the Engineer - in- Charge.
Providing and laying cement concrete 1:1.5:3 ( 1cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reingorcement for reinforced concrete work in :-
Foundation, footing and bases of columns and the like and mass concrete within all leads and lifts complete in all respect.
Suspended floors, roofs, landing and shelves and their support balconies, beams, girders, bressumers and cantilevers upto floor two level.
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centering, shuttering, struting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for in situ-reinforced concrete and plain Concrete work in :-
Flat surfaces such as soffits of suspended floors, roofs, landing and the like Floors etc. upto 200 mm thickness in all leads and lifts and as per the direction of the Engineer-in-Charge.
Beams,cantilever,girders and lintels.Sides and soffits of beams,beam haunchings, cantilevrs, bressumers and lintles not exceeding 1.00 mtr.in depth in all heights from floor.
Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size ) laid in one layer finished with a floating coat of neat cement in all leads and lifts and as per the direction of the Engineer-in-Charge 40 mm thick.
Cement concrete flooring 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size ) laid in one layer finished with a foating coat of neat cement in all leads and lifts and as per the direction of the Engineer-in-Charge 25 mm thick.
15 mm cement plaster in single coat on rough side of brick masonry for interior plastering upto floor two level including arrises, internal rounded angle, chamfers and or rounded angles not exceeding 80 mm in girth and finished even and smooth with cement mortor 1:6 ( 1 cement :6 sand ) in all leads and lifts as per the direction of the Enginner-in-Charge.
Pointing on brick work with cement mortor 1:3 ( 1 cement: : 3 sand ) in all leads and lifts as as per the direction of the Engineer - in- Charge.Cut or weather struck.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size ) in all lead and lifts as per the direction of the Engineer - in- Charge.
Applying priming coat over new wood and wood based surfaces after and including preparing the surface by throughly cleaning oil, grease,dirt,and other foreign matter sand papering and knotting with ready mixed paint brushing wood primer pink complete in all respect as per the direction of the Engineer-in-Charge.
Painting two coats excluding priming coat on new wood and wood surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter sand papering and stoping complete in all respect as per the direction of the Engineer - in - Charge.
White washing with lime on undecorated wall surface ( three coats) to give an even shade including throughly brooming the surface to remove all dirt ,dust mortor drops and loose scale of lime wash and other foreign matter complete in in all respect as per the direction of the Engineer-in-Charge.
Hirmachi colour wash on undecorated wall surfaces (Three coats) to give an even shade including thoroughly brooming the surfaces to remove all dirt,dust, mortar drops and other foreign matter complete in in all respect as per the direction of the Engineer-in-Charge.
Providing and fixing MS grills of required pattern in wooden frame / pressed steel frame with MS flats square / rounds bars 12 mm dia with round headed bolts and nuts or by screws in all leads and lifts and as per the direction of the Engineer - in- Charge Plain grills.
Providing Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level in all respect in all leads and lifts & as per direction of the Engineer-in-Charge.
Providing 40x3mm flat iron hold fast 40 cms long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15 cms 1:3:6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size ) complete in all respect as per the direction of the Engineer -in- Charge.
Providing and fixing sliding door bolts anodized transparent or dyed to required shade and colour with screws etc. complete in all respect 250x16 mm
Providing and fixing tower bolts barrel type anodized transport or dyed to required shade and colour with screws com lete in all respect. 250x10mm.
Providing and fixing tower bolts barrel type anodized transport or dyed to required shade and colour with screws com lete in all respect. 150x10mm.
Providing and fixing aluminium handle anodized transparent or dyed to required shade and colour with screws etc. complete in all respect 100mm dia
P/F MS fan clamps type 1 of 16 mm dia bar bent to shape with hooked ends in RCC slab during laying including painting the exposed portion of roof as per standard design complete in respect .
Half brick work using common burnt clay building bricks in super structure above 1st. floor level in cement mortar 1 : 4 ( 1 cement :4 sand) of 1st. Class bricks complete in all lead and lifts as per the direction of the Engineer-in-Charge.
Excavation in earth work and filling in 15 cm. layers in foundation & plinths including ramming, watering and consolidating complete in all respect including carriage of materials within all leads and lifts and as per the direction of the Engineer-in-Charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect
Steel work welded built up sections, trusses and framed work , including cutting , hoisting , fixing in position and applying a priming coat of red lead paint in beams joists channels, angles , tees, flats with connection plates or gratings framed guard bars, ladders,. railling, brackets and similar works.
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter with enamel paint other than white complete in all respect as per the direction of the Engineer-in-Charge.
Wiring for light/Fan point/Exhaust fan point/call bell point with 1.5 Sq.mm PVC insulated copper conductor cable in surface/recessed PVC conduct at required including carriage of all material within all leads and lifts. Group "C"
Wiring for light/power plug with 2 x 4 Sq.mm PVC insulated copper conductor or single core cable in surface/recessed steel conduit alongwith 1 No. 4 Sqmm dia bare copper wire for loop earthing as required including carriage of materials within all leads and lifts.
Wiring for circuit wiring with 2 x 1.5 Sq.mm PVC insulated copper conductor single core cable in surface/recessed steel conduit as required including carriage of material within all leads and lifts.
Wiring for sub-main wiring with the following size of copper conductor single core cable in surface/recessed steel conduit as required including carriage of materials upto all leads and lifts. 2x6 Sq.mm
Supplying and fixing metal box of 180 x 100 x 60mm deep (Nominal size) on surface/recess with suitable size phenolic leminated sheet cover fixing 3 pin 5/6 amps socket tumber/piano type switch connections painting etc. including carriage of materials within all leads and lifts.
Supplying and fixing backellite batten/angle holder including connection as required.
Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length (upto 30cm) with 1.5 Sqmm PVC insulated copper conductor single core cabe etc. as required sweep type. Cat. A (1200 mm sweep)
Providing, installation, testing and commissioning of prewired flourscent tube fitting complete with ballast, starter and capactors but excluding flourscent tube rod, suitable to operate on 230 volts single phase A.C.supply directly on surface with copper wiring as required including carriage of materials within all leads and lifts tube fixture 1 x 36 watt Box type Category "A".
Supplying and fixing 40Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of material within all leads and lifts. Category- A, 63 Amps.
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed completed with tinned, copper busher neutral link, earth bar, detachable gland plate inter -connections, including painting, earthing etc. as required Bus bar 8 way.
Supplying and fixing 5Amps to 32 Amps rating, 10 KA breaking capacity 240 volts, C series miniature circuit breaker of following poles in the existing MCB, DB complete with connections testing and commissioning etc. Category "A", single pole.
Earthing with G.I. pipe earth, pipe 4.5 mtrs length, 40mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc.( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts.
Extra using salt and charcoal for pipe earth electrode as required, including carriage of materials within all leads and lifts.
Supplying and laying 6 Sqmm G.I.wire at 0.50 mtr below ground level for conductor earth electrode, including soldering etc. as required including carriage of materials within all leads and lifts.
Providing, fixing & testing Street Light Fixture with CFL of 36 watt, copper ballast, G.I. Pipe bracket, complete in all respects including carriage of materials within all leads and lifts..
C/o RCC Storage Tank 325000 ltrs capacity, OHSR 75000 ltrs cap, 15mtr staging height) Excavation in foundations,trenches etc., in earth work, lift upto 1.50 mts. Stacking the excavated soil not more than 3 mts. Clear from the edge of the excavation & then returning the stacked soil in 15 cms. Layers,when required into plinths sides of foundation etc.,consolidating each deposited layers by ramming & watering & then disposing of all surplus excavated earth as dierected within all leads & lifts as per entire satisfaction of Engineer in charge.
Providing & laying cement concrete M-10 mix concrete using graded stone aggregate 40 mm nominal size, excluding the cost of centring & shuttering in Foundation & plinth.
Providing & laying cement concreteM- 30 (not leaner than 1:1.5:3) mix concrete using aggregate 20 mm nominal size) & curing complete excluding the cost of form work & reinforcement for reinforced concrete work in all leads and lift and as per the direction of Engineer-in-Charge.
Foundation,footing.bases of columns & the like & the mass concrete.
(ii) Wall (any thickness but not less than 0.10 mts.Thickness)attached pillasters,buttresses plinth,& string courses etc.from top of found.level upto floor two level
(i) floor four level to floor five level
Column,pillars,posts & struts upto floor two level
(ii) floor two level to floor three level
(iii) floor three level to floor four level
(iv) floor four level to floor five level
Lintels,beams girders bressumers & cantilevers upto floor two level
(ii) floor two level to floor three level
(iii) floor three level to floor four level
Arches:
i) upto floor two level:
(ii) floor two level to floor three level
(iii) floor three level to floor four level
Suspended floors,roofs,landings and shelves & their support balconies,beams ,girder,bressumers and cantilever. upto floor two level
(i) floor two level to floor three level
(ii) floor three level to floor four level
Prov.form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm,so as to give a fair finish i/c centring shuttering,strutting & propping etc. with wooden battens & ballies,ht. of propping & centring below supporting floor to ceiling not exceeding 4.00 mts. & removal of the same for in situ-reinforced concrete & plain concrete work :-
(i) Foundation,footing,bases of columns etc.and mass concrete.
(ii) Flat surface such as soffits of suspended floors,roofs,landing and the like
(iii) Vertical surfaces such as walls (any thickness) partitions and the like i/c attached pillastres buttresses, plinth & string courses and the like.
(a) Upto 4.00 mtrs.
For Vertical surfaces of tank
(iv) Columns,pillars,posts & struts,square ,rectangular or polygonal in plan.
(b) Beyond 4.00 mtrs.
(v) Beams, cantilever, girders & lintels.
Sides & soffits of beams,beam haunchings, cantilevers, bressumers & lintels not exceeding 1.00 mtr.depth in all ht.from floor.
Providing form work of ordinary timber plankings, so as to give a rough finish including centring, shuttering , strutting and propping etc height of propping and centering below supporting floor to ceiling not exceeding 6.00 mtrs.height and removal of the same for in situ reinforced concrete and plane concrete work in arches upto 6 mtrs span in all respect in all leads and lifts.
Beyond 4.00 mtr.height.
Providing Tor steel reinforcement for RCC work including bending,binding & placing in position complete upto floor two level.
Providing in RCC work smooth finishing of the exposed surface with cement mortor 1:3 (1cement :3 Sand) complete in all respect within all leads & lifts.
Finishing wall with water proofing cement paint of approved brand & maunfacture and of required shade on undecorated wall surfaces (two coats) to give an even shade after throughly brushing the surface to remove all dirt & remains of loose powedered material etc complete in all respect.
Providing & fixing 500 mm dia.SFRC man hole cover with frame and the weight of frame & cover should not be less than 100 kg complete in all respect within all leads & lifts.
Fixing of GMS Pipes conforming to relevants BIS codes of below mentioned diameters fully jointed with MS Flanges of Table - 5 as per IS :6392 - 1971 excluding the cost of excavation in trenches complete in all respect within all leads & lifts.
i) 150 mm Inlet pipe, Outlet pipe, Over flow pipe & Scour pipe
ii) 65 mm Inlet pipe, Outlet pipe, Over flow pipe & Scour pipe
Steel work welded in built up sections,trusses & framed work i/c cutting, hoisting,fixing in position & applying a priming coat of red lead paint.In grating,framed guard bars,ladders,railing,brackets & similar works.
Fixing of GMS Pipes conforming to IS 1239 - 1979 (Part-1) screwed & socketed joints (Light grade) excluding the cost of excavation in trenches 25 mm Dia
Providing & fixing CI sluice valve (with hand wheel) as per IS:780 - 1984 Class-I upto 300 mm dia i/c brass spindle & as per 2906 - 1984 Class II i/c MS Flange i/c carriage of material within all leads and lifts bolts,nuts,rubber insertion etc,(The tail pieces if required shade etc.
i) 150 mm Inlet pipe, Outlet pipe, Over flow pipe & Scour pipe
ii) 65 mm Inlet pipe, Outlet pipe, Over flow pipe & Scour pipe
Providing & fixing bends of required degrees made from parent tubes conforming to relevant codes fully flanged with MS Flange of Table - 5 conforming to IS: 6392 - 1971 complete in all respect within all leads & lifts.
i) 150 mm Inlet pipe, Outlet pipe, Over flow pipe & Scour pipe
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 Cement: 3 Sand: 6graded stone aggregate 20 mm nominal size) complete in all respect within all leads & lifts.
Providing under layers for plinth protection 75 mm thick (unconslidated) bed dry brick/stone aggregate 40 mm nominal size with rammed & grouted with fine sand i/c preparation of ground complete in all respect within all leads & lifts.
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia.&180 mm deep (inside) with chained lid RCC top 1: 2: 4 mix (1 cement :2 Sand :4 graded stone aggregate 20 mm nominal size ) 100 mm thick foundation conc.1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1:3 (1 Cement : 3 Sand ) finished with a floating coat of neat cement i/c curing complete. 600 x 600 x 750 mm inside size With 150mm thick walls of RCC 1:2:4 (1cement : 2 sand :4 graded stone aggregate 20 mm nominal size) complete with form work & reinforcement with 6 mm bars at not exceeding 150 mm centres both ways within all leads and lifts complete in all respect.
Providing and Fixing of Lightening conductor i/c carriage all leads and lifts.
Providing and Fixing Water measurement gauge of standard design complete in all respect.
Providing and Fixing vent opening i/c cowl with mesh in the top of the tank i/c carriage. As per the dirction of the Engineer-in -charge.
Structural design and drawing complete in all respect.
Soil testing report for bearing capacity of soil.
Om Parkash Govt Contrator
Surinder Kumar Thakur
Suresh Kumar
Ankush Dhiman
Harvinder Singh Maan
SG Engineers and Consultants
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .