Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
23 Sept 2026, 12:00 pmDue tomorrow
SE EM CIRCLE PWD AGRA
SE EM CIRCLE PWD AGRA
Supply and installation of new air conditioning units and other equipment to replace the old air-conditioning units and equipment in Suites No. 1A 1B through 3A 3B and the meeting hall at the Transit Hostel Circuit House in Mainpuri district.
2026_CEEMP_1186961_1
1301/6WE(Agra)-E/M Circle agra Dt.07.09.2026
Open Tender
Electrical Works
Percentage
90 days
E/M DIV PWD AGRA
Supply and installation of new air conditioning units and other equipment to replace the old air-conditioning units and equipment in Suites No. 1A 1B through 3A 3B and the meeting hall at the Transit Hostel Circuit House in Mainpuri district.
2 documents required · 2 mandatory
₹856
₹1.4 L
E/M DIV PWD AGRA
17 Sept 2026
17 Sept 2026
23 Sept 2026
17 Sept 2026
23 Sept 2026
17 Sept 2026
18 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of 2.0 TR with 5 Star BEE Rating with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). | 16 | Nos. | 42,014 | ₹6,72,224 |
| - | Supply of wall mounted copper wounded Voltage stablizer 5 KVA Capacity | 16 | Nos. | 5,050 | ₹80,800 |
| - | SITC of suction/discharge pipe line in split A.C unit upto 2.0 toncapacity including brazing,nitrile,rubber insulation 6 mm thick class"O" etc.complete 3/8"(9.50 mm) and 5/8" (15.90mm) | 240 | Mtr. | 1,450 | ₹3,48,000 |
| - | Supply and laying of heavy duty PVC plastic braided 20mm OD flexible pipe for condensed water with dipping accessories complete | 250 | Mtr. | 160 | ₹40,000 |
| - | Fabrication of M.S stand for Outer unit of A.C withfixing on wall with all material & labour complete in all respect | 16 | Nos | 1,250 | ₹20,000 |
| - | Fabrication and fixing of Iron security cage for outdoor unit of A.C including cost of angle , jali, welding fastnur & T&P required with painting | 16 | Nos | 4,050 | ₹64,800 |
| - | S/F of 2.5 mm2 FRLSH Copper wire 3 core (Power Lead) for connection of stabliser to outdoor unit . | 250 | mtr | 140 | ₹35,000 |
| - | Supply and Fixing of Geyser capacity 25 ltr. Make havells Model Fabia. (Product code. GHWAFATIB025), 5 star rating. | 7 | Nos. | 13,390 | ₹93,730 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
T1inspectionmain2627.pdf
Tender Documents • 5.51 MB
BOQ_2234628.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .