Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-AOC | L1 | Accepted-AOC As per TCR | |
| 2 | L2₹4.1 L+₹1,312.16 (0.32%)Rejected-Finance AT PO SAYAL DISTT RAMGARH PIN 829125 | SAYAL | RAMGARH | JHARKHAND | 829125 | L2 | Rejected-Finance As per TCR |
Tender Value
₹3.7 L
EMD Value
₹4,700
Closing Date
6 Mar 2023, 5:00 pmClosed
Project Engineer (EnM),Urimari OCP
Office of The Project Engineer (EnM),Urimari OCP, Barka Sayal Area, Pin 825311
Complete electrical rewiring of Urimari Thana under Urimari OCP.
2023_CCL_272689_1
PE(EnM)/Urimari/e Tender/22-23/101Dated 24/02/2023
Open Tender
Electrical and Maintenance Works
Item Wise
15 days
Urimari OCP
As per NIT
2 documents required · 2 mandatory
₹4,700
9 May 2023
25 Feb 2023
7 Mar 2023
25 Feb 2023
6 Mar 2023
25 Feb 2023
25 Feb 2023 - 1 Mar 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(2 X 4 sq. mm + 1 X 4 sq. mm earth wire)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(2 X 2.5 sq. mm + 1 x 2.5 sq. mm earth wire)
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(5/6 amps socket) Outlet.
Providing of 63 Amp Switch Fuse unit
Providing of 32 Amp Switch Fuse unit
200mm x150mm x 75mm deep metal box etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass button/ angle holder including connection etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Double Pole)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 4 way/ 6 way , Double door
Copper service wire 2 core 6 sqmm
Installation of maintenance free chemical earthing:Make Ashok,model:T-39mm, 3mtrs with BFC bag approximately 50Kg(25X2) with all accessories
Fixing and Contractor profit(Si. No. 5,6 &14)
Total impact of GST for the purpose of CTC
M/S ABHISHEK ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .