| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹41.3 L+₹1.8 L (4.50%)Rejected-Finance | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹43.1 L+₹3.6 L (9.05%)Rejected-Finance | L3 | Rejected-Finance Other than lowest. |
Tender Value
₹37.0 L
EMD Value
₹73,980
Closing Date
21 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) 866 EWS Carnicobar
GE(I)866 EWS CARNICOBAR PIN-913866 C/O 99APO
REPAIR / MAINTENANCE OF AC PLANTS AND SUMMER, COOLING APPLAINCES AND ITS PERIODICAL MAINTENANCE AT AF STATION CARNICOBAR.
2023_MES_624770_1
8658/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (I) 866 EWS Carnicobar
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (I) 866 EWS
₹73,980
Yes
8 Feb 2024
24 Oct 2023
28 Nov 2023
24 Oct 2023
21 Nov 2023
7 Nov 2023
Amount
S&F in replacement of blower belt of AHU / Compressor belts as per existing model and type ISI marked including re-alignment of the motor and blower if required for proper tension of belts as directed by Engr-in-charge.
M&L for replacement of unserviceable scroll type compressor of package type ac plant of cap 5.5 TR capacity suitable for working on 3 phase, 50Hz, suitable for R-407c Refrigerant, having mineral lubricant oil, LRA-I Block 75.0,67-0-74-0 ,I opera Max 12.1, including crank case heater, cutting brazing to inlet out let refrigerant piping, nitrogen pressure test for leakage testing, vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified by OEM & directed by Engr in Charge. Make - Emersion Copeland Scroll Model No ZR72KCE-TFD-522 or equivalent in Danfoss
M&L for replacement of unserviceable digital micro processor controller PCB complete suitable for Model No DPA661S Nominal Cap 16500Kcal/Hr 415V, 3 Phase, 50 Hz, Rated Amp 13. Make- Blue Star / Soft Hard or equivalent
M&L for replacement of unserviceable digital microprocessor controller micro PCB complete suitable for Package type AC plant model No DPA1983R2A-I nominal capacity 49500 Kcal/Hr with contactor complete as specified by OEM & directed by Engr in Charge Make- Blue Star /Soft Hard or equivalent
M&L for replacement of unserviceable digital microprocessor controller PCB complete suitable for Package type AC plant model No XAC2S-024MAR2 of Make Bluestar with contactor & relay complete as specified by OEM & directed by Engr in Charge Make- Blue Star /Soft Hard or equivalent
M&L for replacement of crank case heater of scroll type compressor suitable for 5 to 18 TR capacity as per existing type capacity and model.
M&L for taking out existing unserviceable scroll compressor and replace with new compressor suitable for working on 380-415V 3 phase , 50Hz, LR 175A, Max Oper-35A, thermally protected system, PED, LP side (PS 25 bar, TS max 54oC TS min : -35oC, Vol 31.0L), HP side (PS 31.9 bar, TS max 150oC, TS min : -35oC, Vol 2.0L), having lubricant Mineral Oil P.O.E.160SZ , crank case heater, suitable for R-407C refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing , vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make- Danfoss commercial compressors Model No- SZ185S4RC or equivalent.
M&L for replacement of defective temperature controller with sensor including making proper wiring & connections of chiller line complete all as specified & directed by Engr in Charge. Make: Sub-zero, Honeywell, Schneider
M&L for replacement of defective humidity controller with sensor including making proper wiring & connections complete all as specified & directed by Engr in Charge. Make : Sub-zero, Honeywell, Schneider
Replacement of unserviceable flow switch of chiller & condenser line 63 to 200mm dia line , including making all control connections complete all as specified & directed by Engr in Charge. Make : Honeywell or its equivalent.
M&L for Servicing of outdoor (condenser) unit of air cooled central / Package type AC plant by cleaning of fins by water jet of suitable pressure or cleaning by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking electrical wiring, servicing, oiling of condenser motor, etc. complete as specified and directed by Engr-in-charge.
M&L for Servicing of water & air cooled chiller central / Package type AC plant 22.7 TR through OEM service Engineer having min 5 yrs. experience by cleaning of fins by water jet of suitable pressure or cleaning by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of condenser motor, etc. complete as specified by OEM and directed by Engr-in-charge. Make of installed plant- Blue Star
M&L for Servicing Indoor units of air cooled central/ Package type AC plant 5.5 TR through OEM service Engineer having min 5 yrs. experience by cleaning of cooling coil by using chemical if reqd, including combing of fins by using fins comb to making straight the fins, checking all electrical & control wiring, servicing, oiling of blower motor, etc. complete as specified by OEM and directed by Engr-in-charge. Make of installed plant- Blue Star
M&L for replacement of unserviceable fan blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable condensor fan motor with blade of outdoor condenser unit of air cooled water chiller AC plant 22.7TR (Model XAC2S-024MAR2 of Make Bluestar ) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable blower motor 3 Phase, 415 V, 50 HZ, 0.75 HP 1400 RPM, s1 duty, Frame-80 of air cooled AC plant (5.5 TR) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable motor suitable for working on single phase, 230V,50 Hz 1/3HP, 920 RPM, thermally protected of outdoor condenser unit of air cooled package/ central type AC plant (5.5 TR) as per existing make, model and type complete all as directed by Engr-in-charge.
M&L for servicing of Main Electric Panel board / Control panel board of Central / Package type AC Plant by cleaning the panel with blower, replacement of unserviceable burnt wire, cables with existing size & length including proper numbering, replacement of u/s fuse link, lugs, washer, nuts, bolts, checking proper electrical connection, connectivity etc. & find out defective parts and making the panel functional by replacing the unserviceable item (taken as supply only) as directed by Engr-in-charge. Note : - (i) Unserviceable parts as MCB, MCCB, contactor, relay, MPD, etc. will be measure and paid separately under relevant items of BOQ at supply only rates. (ii) Minor parts like thimbles, tags, nut, bolts, washers etc shall be deemed to be included in rate quoted against this item.
Supply only the following for above items (Make- Hager/Legrand/C&S/L&T/Merlin Gerin)
MCB 6-32 Amp SP C series
MCB 6-32 Amp SPN C series
MCB TPN 40 to 63Amp C series
MCB TPN 10 to 32 Amp C series
Add on Auxiliary contact block (MNX A-2 /MNX A-1/TA1-DN22)
HRC fuse link RH type having breaking capacity 80 kA ( 2-32 amps)
HRC fuse link bottle/Din type having breaking capacity 80 kA (36 to 63 amps)
Fuse bases for HRC fuse up to 32 Amp
Electronic Timers 110 / 240 / 360 / 415Volts 50 Hz for (3-10/ 9-30/36-120 Sec)
R / Y /B Phase / On / Trip indicating lamps (as per colour code)
Contactor MNX9
Contactor MNX18
Contactor MNX25
Contactor MNX32
Single phase preventer suitable for 3 HP to 15 HP Monoblock pump sets (Make Minilic)
3 way valve controller current transformer 60 XA. Make SS Enterprises or equivalent
MCCB 200A 4 Pole DU series
MCCB 100A 3 Pole DU series
Material and labour for taking out unserviceable burnt electric motor of (compressor / Monoblock pump set / Blower / condenser / cooling tower) and rewinding the same by removing the burn out copper coil cleaning the motor and winding with super enamel copper wire of same gauge & turns including varnishing, providing new insulation sheet, heating the winding including replacement of unserviceable both end bearings, bush of existing size etc reqd at site, refixing to its original place and testing after repair complete all as specified and directed by Engr in charge. for following capacity:- Note: Rates for transportation from site to workshop & return shall be deemed to be included in quoted rates.
Up to 2 HP single / three Phase
3 HP 3 phase
5 HP 3 phase
7.5 HP 3 phase
M&L for replacement of butter fly valve including taking out existing unserviceable butter fly valve and making good to the disturbed surface matching to existing specification (i.e. insulation of chiller / condenser pipe line) of following size. Make sant ,zoloto,kirloskar or equivalent
(a) 80 mm dia
(b) 100 mm dia
Supply and filling/topping up refrigerant gas R-22/R-404a/R-407c in scroll compressors of package type AC plants of any capacity as per OEM specification including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Make : Mefron/Floron/Refron. Note :- The rates quoted by the contractor for topping up/ filling of refrigerant gas shall deemed to include leakage detection, rectification of leakage by brazing, nitrogen pressure testing, etc.
M&L for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., keeping the AC unit in satisfactory working condition after necessary servicing complete all specified and directed by Engineer-in-Charge.
M&L for servicing of Window type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, keeping the AC unit in satisfactory working condition after necessary servicing refixing the same in existing position complete all specified and directed by Engineer-in-Charge.
S&F in repairs Running capacitor 2.5 to 10 MFD. (Make:- Epcos/ Usha/ Keltron.)
S&F in repairs Running capacitor 36 to 50 MFD. (Make:- Epcos/ Usha/ Keltron.)
S&F in repairs Starting capacitor 80 -120 MFD. (Make:- Epcos/ Usha/ Keltron.)
S&F in repairs Starting Relay for window/split AC. (Make:- Hytec/ Renutral/ Sri Ram/Microtech.)
S&F in repairs Overload Relay for window/split AC . (Make:- Hytec/ Renutral/ Sri Ram/Microtech.)
S&F in repairs Thermostat switch window/split AC. ( Make :- Indfoss/ Renutrol).
S&F in repairs Condenser fan blade for Window type A.C of Capacity 1.5/2.0 TR made of Plastic.
S&F in repairs Condenser fan blade for spilt Type A.C of Capacity 1.5/2.0 TR made of Plastic.
S&F in repairs Wiring kit for Window/split type AC of Capacity 1.5/2.0 TR
S&F in repairs Remote control compatible for split AC of Cap 1.5/2.0 TR of any make and model as per site requirement as directed by Engr-in-Charge.
S&F in repairs main printed circuit board (PCB) with electric accessories and sensors suitable for non invertor Split / Window AC of capacity 1.5/2 TR as directed by Engr-in-Charge.
Labour only for rectification of water leakage problem of AC unit by cleaning indoor unit & drain pipe of split type AC up to 2 Ton cap complete all as specified and directed
Supply & fixing in repairs plastic louvers for (Front panel) for Window AC 1.5/2 TR complete all as directed by Engr-in-Charge.
Supply & fixing in repairs of suction and discharge valve set of follwing sizes complete all as directed by Engr-in-Charge.
suction and discharge valve set 15mm (5/8'') and 10mm (3/8") for Split AC 2 TR capacity
suction and discharge valve set 6mm (1/4'') and 12mm (1/2'') for Split AC 1.5 capacity
Supply & fixing in repairs of capillary tube for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge.
Supply & fixing in repairs of capillary filter for Split/ Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge.
Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2 TR and refixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed by Engineer-in-charge.
Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap 2 Ton, of any make any type from any location and Supply , Installing and testing of new sealed unit compressor alongwith test certificate from manufacturer including cleaning and removing dust/dirt from the cooling coil condenser coil with necessary modification capillary tube etc & Charging of Gas R-22/R-32/R-410a and commissioning complete all as specified & directed by Engg-in-Charge. (Make:- Emerson /Tecumseh/ LG)
-ditto- all as per item No. 42 above but window type Air Conditioner of Capacity1.5 TR. (Make:- Emerson /Tecumseh/ LG)
-ditto- all as per item No. 42 above but spilt type Air Conditioner of Capacity 2 TR. (Make:- Emerson /Tecumseh/ LG)
-ditto- all as per item No. 42 above but spilt type Air Conditioner of Capacity 1.5 TR. (Make:- Emerson /Tecumseh/ LG)
Supply & fixing in repairs of Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Supply & fixing in repair copper wounded Indoor Air blower motor for Split AC 1.5/2 TR capacity complete all as specified & as directed. Make-AUE/Speed King/Cool Master.
Supply & fixing in repairs of copper wounded condenser fan motor for Split type AC of 1.5 TR & 2 TR capacity outdoor units complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
Disconnecting the mains and taking out the unserviceable condenser coil of window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make :- As per exisitng sample)
-ditto- all as per item No.49 above but spilt type Air Conditioner Capacity 1.5/ 2 TR. (Make:- As per existing sample)
Supply & fixing in repairs of evaporator/cooling coil for window type Air Conditioner of capacity 1.5/ 2TR of existing make and size complete all as specified & as directed by Engr-in-Charge.
-ditto- all as per item No. 51 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
Supply and fixing in repairs of 1.5TR capacity split type Air Conditioner outdoor kit including rotary compressor, copper condenser coil, blower motor, chasis, base plate, including initial charging of gas complete all as specified & as directed by Engr-in-Charge. (Make:- Commander/Camipro/Skoda/Hitachi.)
All as per item No. 53 above but spilt type Air Conditioner of capacity 2 TR. (Make:- Commander/Camipro/Skoda/Hitachi.)
Taking down unserviceable indoor unit of split type AC of any make and supply & fixing new indoor unit complete set suitable for 1.5 TR capacity inlcuding remote complete all as directed by Engr-in-Charge. (Make:- Hitachi/ Camipro)
All as per item No. 55 above but spilt type Air Conditioner of capacity 2 TR including remote. (Make:- Hitachi/ Camipro)
Supply & fixing heavy duty copper pipe 12 mm (1/2") dia/ bore complete including nitrile rubber insulation, brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. Make Godrej / Malaysia / Johnson or equivalent.
-ditto- all as per item No. 57 above but copper pipe 6mm (1/4") dia/ bore.
-ditto- all as per item No.57 above but copper pipe 15mm (5/8") dia/ bore.
-ditto- all as per item No. 57 above but copper pipe 10mm (3/8") dia/ bore.
Taking down unserviceable insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 4.0 TR all as specified and directed by Engineer-in-charge.
M&L for replacement of PVC pipe 20mm dia heavy duty with all fittings (bend, elbow, tee) etc including fixing with clamp on wall or floor for AC drain line complete as directed. Make Astral / Prince and equivalent.
Supply and filling refrigerant gas R-22/R-32/R-404a/R-407c/410a in window /Split Type AC unit of capacity 1.5/2 TR and in compressors of Cold storage units of any capacity as per OEM specification including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Make : Mefron/Floron/Refron. Note :- The rates quoted by the contractor for topping up/ filling of refrigerant gas shall deemed to include leakage detection, rectification of leakage by brazing, nitrogen pressure testing, etc.
Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 1.5 to 2.0 TR all as specified as idirected by Engineer in-charge.
Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed.
Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal cross sectional area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed.
Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal cross sectional area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded, unsheathed 1100 volts grade in PVC casing caping (heavy grade) of adequit size with all fittings and casing caping accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694) as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) {Notes for item No.66 & 67 :-(i) Two runs of cable with one run of earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.}
Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed. (Make:- Schnieder/ Legrand/ ABB/ Seimens/ L & T)
Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and as directed. (Make:- Schnieder/ Legrand/ ABB/ Seimens/L & T)
Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed.(Make:- Schnieder/ Legrand/ ABB/ Seimens/ L & T)
Supply & fixing in repairs metal clad plug with two pin of capacity 20 Amps complete all as specified & as directed.(Make:- Schnieder/ Legrand/ ABB/ Seimens/ L & T)
Disconnecting from mains and taking down for servicing of Water Cooler of Capacity 40/80, 60/120, Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs over load protector relay suitable for 40/80, 60/120 Ltrs capacity water coolers. Make : Renutrol/Sri Ram/Microtech
S&F in repairs thermostat suitable for 40/80, 60/120 Ltr capacity water coolers. Make : Indfas/Renutrol
S&F in repairs condenser motor fan blade suitable for 40/80, 60/120 Ltr capacity water coolers.
S&F in repairs PVC flexible drain Hose Pipe 40 mm.
S&F in repairs Waste water tray complete suitable for 40/80, 60/120, 150/150 Ltr capacity water coolers all as directed.
S&F in repairs chromium plated push taps suitable for 40/80, 60/120 Ltr capacity water coolers all as directed. Make : Usha/Prayag/Cera/Essco.
S&F in repairs PVC float valve of size 15mm dia complete suitable for 40/80, 60/120 Ltr capacity water coolers including GI socket of same size all as directed.
S&F in repairs Starting Capacitor 25 MFD for water coolers. Make : Bentex/Delcon/Epcos
S&F in repairs running Capacitor 10 MFD for water coolers. Make : Bentex/Delcon/Epcos
S&F in repairs Starting relay suitable for 40/80, 60/120 Ltr cap water coolers. Make : Renutrol/Sri Ram/Microtech
Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/16 HP from water cooler cap. 60/120 Ltr and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE/ Cool Master)
All as per item No.83 above but 1/32 HP Water cooler of Capacity 40/80 Ltrs.
Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-134A, commissioning and testing Water Coolers of 40/80 Ltrs capacity complete all as specified and directed. Make :- Emerson /Tecumseh/LG.
Dismantling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-134A, commissioning and testing Water Coolers of 60/120 Ltrs capacity complete all as specified and directed. Make :- Emerson /Tecumseh/LG.
Disconnecting the mains and taking out the unserviceable condenser coil and S&F new condenser coil as per existing size & patterns for Water Coolers of capacity 40/80 & 60/120 Ltrs complete all as specified & as directed.
Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff)
Dismanling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-134A, commissioning and testing refrigerators of 165 to 210 Ltrs capacity complete all as specified and directed. Make :- Emerson /Tecumseh/LG.
Dismanling and removing defective compressor and supply and fixing (in repairs) new sealed compressor of approved make obtained from authorised dealers submitting Warranty certificate & test certificates from manufacturer/authorised dealers including charging of refrigerent gas R-134A, commissioning and testing refrigerators of 280 to 310 Ltrs capacity complete all as specified and directed. Make :- Emerson /Tecumseh/LG. Note :- (i) The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor's repair workshop and back.
Dismantling of existing repairable Refrigerators of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. Note :- Parts replaced shall be measured and paid separately under relevant items of BOQ at supply only rates.
Supply and filling refrigerant gas R-134A in Refrigerators/Deep Freezers/Water Coolers of any capacity, model and make including detecting the leakage of gas at any location and rectifying the defect to stop the leakage by gas welding or by any other means including including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition. Make : Mefron/Floron/Refron.
Supply only capillary tube of existing size including necessary brazing suitable for 165/300 Ltrs capacity refrigerator, including dismantling the old unserviceable one all as specified and directed.
Supply only over load protector relay suitable for upto 310 Ltrs capacity refrigerator all as directed. Make : Renutrol/Sri Ram/Microtech
Supply only thermostat suitable for upto 310 Ltrs capacity refrigerators all as directed. Make : Indfas
Supply only freezer door with spring of refregierators of any capacity & make all as specified and directed.
Supply only vegetable basket with glass suitable for upto 310 Ltrs capacity refrigerators.
Supply only PVC defrost tray as per sample suitable of upto 310 Ltrs capacity refrigerators.
Supply only door gasket for refrigerators of capacity upto 310 Ltrs complete all as specified and directed.
Dismantling of existing repairable deep freezers upto 400 Ltrs of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, all as specified and directed by Engineer-in-Charge. Note :- Partsreplaces shall be measured and paid separately under relevant items of BOQ at supply only rates.
Supply only starting relay suitable for deep freezer upto 400 Ltrs capacity. Make :- Renutrol/Sri Ram/Microtech
Supply only over load protector suitable for upto 400 Ltrs capacity deep freezer all as specified and directed. Make : Renutrol/Sri Ram/Microtech
Supply only running capacitor for upto 400 Ltrs capacity deep freezer all as specified. Make : Bentex/Delcon/Epcos
Supply only starting capacitor for upto 400 Ltrs capacity deep freezer all as specified and directed. Make : Bentex/Delcon/Epcos
Supply only thermostat suitable for upto 400 Ltrs capacity deep freezer all as specified and directed. Make : Indfas
Supply only Axial Fan for deep freezers complete all as specified and directed.
Taking down defective compressor of deep freezer of capacity Upto 400 Ltrs and any make and supplying and fixing new sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant gas Non CFC based or equivalent to Non CFC gas in required qty and testing complete all as specified and directed by Engineer-in-Charge. Make :- Emerson /Tecumseh/LG.
Servicing of air curtains, single phase, 240V by checking all electrical connection, blower, motor oiling greasing and replacement of u/s wire, lugs, bushes, rubber pads, bearing etc. all as directed by Engr-in-charge.
Labour only for taking out existing split type air conditioners of any type and capacity removing from the site and keeping it in a safe custody for re-use or deposit in store all as specified and directed.
Fixing only split type air conditioners of any type and capacity including core cutting for passing copper tubing , drain pipe & cable through wall with connected accessories such as mounting bracket with fasteners, copper tubing & elect power cord cable from indoor to out door unit and drain water pipe etc as per site requirement all as specified and directed.
M&L for replacement of single phase Axial fan motor 220V, 50 Hz, 0.42A, 90W, 1350 RPM CE certified weather proof cooling coil motor suitable for cold storage 0 to -18o C. Make- Osaka Shoji Kaisha Ltd / HI cool
M&L for replacement of unserviceable digital controller model No BSL52 of Blue Star suitable for cold storage 1/1.8 Ton cap having -2o to -10o C temp range complete with sensor & control wiring. Make- Blue Star
M&L for replacement of unserviceable digital cold room temp controller model CCR-2052 with MCB of Sub Zero suitable for cold storage 1.8 Ton cap having -0 to -18 oC temp range complete with sensor & control wiring Make - Sub Zero
M&L for replacement unserviceable of SS hinges of cold storage unit as per existing type & model complete as required at site & directed by Engr in Charge. Note: Two no's of SS hinges for bottom and top measured as one unit. i.e., 'Each Set'
M&L for replacement of unserviceable door stopper of cold storage as per existing type & model complete all as specified & directed
M&L for taking out existing unserviceable scroll compressor and replace with new compressor of cold storage suitable for working on 380-415V 3 phase , 50Hz, LR 74A, Max Oper-22.3A, thermally protected system, LP side (PS 22.6 bar, TS max 50oC TS min-35oC, Vol 31.L) HP side (PS 28.5 bar, TS max 60oC TS min-35oC, Vol 1.2L), having lubricant P.O.E.160Z, crank case heater, suitable for R-404a refrigerant etc including making connections inlet outlet refrigerant piping, nitrogen pressure test for leak testing, vacuum the system and charging suitable Refrigerant gas and testing after replacement complete all as specified. Make- Danfoss commercial compressors Model No- NTZ215A4LR1A or equivalent.
M&L for replacement of Refrigerant drier filter as per existing model & type Make including brazing and making leak proof complete all as reqd at site & directed by Engr in Charge
Replacement of unserviceable HP / LP cut outs as per model & type including cutting, brazing complete as specified & directed by Engr in Charge
S&F in repairs FR round PVC insulated multistranded copper conductor cable Twin core of size 2.5 Sqmm complete as directed. Make - Havells/Finolex/Plaza
Supply and fixing in repairs new PCB suitable for LG (Dual inverter)/Hitachi/Voltas/Panasonic make for indoor/outdoor units of inverter ACs of capacity 1.5/2 TR complete all as specified and directed by Engineer-in-Charge.
M&L for disconnecting the unserviceable PCBs from existing LG (Dual inverter)/Hitachi/Voltas/ Panasonic make Inverter ACs of capacity 1.5/2 TR, and re-fixing after necessary repair for satisfactory functioning of the AC unit complete all as specified and directed.
M&L for disconnecting the unserviceable DC condensor fan motor of outdoor units and Supply, fixing & testing for proper functioning of existing LG (Dual inverter)/Hitachi/Voltas/Panasonic make Inverter ACs of capacity 1.5/2 TR
M&L for disconnecting the unserviceable DC blower fan motor of Indoor units and Supply, fixing & testing for proper functioning of existing LG (Dual inverter)/Hitachi/Voltas/Panasonic make Inverter ACs of capacity 1.5/2 TR
MGP Enterprises
M/s Karbhagam Sales Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .