Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAdmitted-Finance | ₹4.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.2 Cr+₹16.7 L (4.16%)Admitted-Finance | ₹4.2 Cr+₹16.7 L (4.16%) | L2 | Admitted-Finance |
| 3 | L3₹4.8 Cr+₹78.1 L (19.4%)Admitted-Finance | ₹4.8 Cr+₹78.1 L (19.4%) | L3 | Admitted-Finance |
| 4 | L4₹5.6 Cr+₹1.6 Cr (40.0%)Admitted-Finance | ₹5.6 Cr+₹1.6 Cr (40.0%) | L4 | Admitted-Finance |
| 5 | L5₹5.7 Cr+₹1.7 Cr (42.8%)Admitted-Finance | ₹5.7 Cr+₹1.7 Cr (42.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ASEM NINGTHEMJAO SINGH L5 | RK FORTUNE DEVELOPERS PVT. LTD. L4 | K. Santabiren Singh L1 | Murphy Thumrah L2 | M/S KIM & SONS CONSTRUCTIONS & EQUIPMENTS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00SH: (1) Academic Building DM college of Arts | ||||||||
| 2.00 | Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. | 144.02 | cum. | 526.6 ₹75,840.93 | 526.65 ₹75,848.13 | 225 ₹32,404.5 | 162.05 ₹23,338.44 | 113 ₹16,274.26 Lowest |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. | 48.01 | cum. | 221.33 ₹10,626.05 | 221.34 ₹10,626.53 | 185 ₹8,881.85 | 122 ₹5,857.22 | 100 ₹4,801 Lowest |
| 4.00 | Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete. | 258.2 | cum. | 1,016.14 ₹2,62,367.35 | 1,000 ₹2,58,200 | 782 ₹2,01,912.4 | 446.39 ₹1,15,257.9 Lowest | 2,905 ₹7,50,071 |
| 5.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size. | 55.88 | cum. | 10,064.18 ₹5,62,386.38 | 8,000 ₹4,47,040 | 7,150 ₹3,99,542 Lowest | 7,235.68 ₹4,04,329.8 | 7,970 ₹4,45,363.6 |
| 6.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size). | 67.73 | cum. | 14,041.86 ₹9,51,055.18 | 12,000.32 ₹8,12,781.67 | 9,540 ₹6,46,144.2 Lowest | 10,077.41 ₹6,82,542.98 | 10,380 ₹7,03,037.4 |
| 7.00 | Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size). | 15.88 | cum. | 15,598.47 ₹2,47,703.7 | 15,599.79 ₹2,47,724.67 | 10,250 ₹1,62,770 Lowest | 11,297.91 ₹1,79,410.81 | 12,882 ₹2,04,566.16 |
| 8.00 | Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size). | 79.62 | cum. | 16,195.53 ₹12,89,488.1 | 13,000.7 ₹10,35,115.73 | 11,050 ₹8,79,801 Lowest | 11,662.57 ₹9,28,573.82 | 13,826 ₹11,00,826.12 |
| 9.00 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars | 31,258.65 | kg. | 124.81 ₹39,01,392.11 | 110.18 ₹34,44,078.06 | 93 ₹29,07,054.45 Lowest | 96.5 ₹30,16,459.73 | 118 ₹36,88,520.7 |
| 10.00Centering and shuttering including strutting, propping etc. and removal of form for: | ||||||||
Tender Value
₹5.7 Cr
EMD Value
₹11.5 L
Closing Date
5 Feb 2026, 5:00 pmClosed
Executive Engineer, Division-I, Education Engineer
Education Engineering Wing, Education (S) Department, Manipur, Babupara, Near D.C. Office (Old), Imphal West
Infrastructure Development of DM University (Classroom construction and half wall fencing), Imphal, Manipur
2026_DoEs_3205_1
EE-I/T-14/E-TENDER/2025-26/23
Open Tender
Civil Works
Works
Imphal
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Chief Finance Officer, Education Engineering Wing,
₹11.5 L
Imphal
25 Mar 2026
16 Jan 2026
6 Feb 2026
16 Jan 2026
5 Feb 2026
17 Jan 2026
22 Jan 2026
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
c) Column, Pillars, Piers, Abutments, Post and Struts.
d) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
e) Stairs, (excluding landings) except spiral-staircases.
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position a) Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Tolhao wood: 35 mm thick shutters
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300 x 16 mm
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. - Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a prime coat of approved steel primer. (a) M.S. tube
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : (a) udaipur green marble.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (i) Electric resistance or induction butt welded tubes.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete: (a) Precoated galvanised iron profile sheets 0.50 mm thick.
at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I,
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 ( 1 cement : 3 fine sand)
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood).
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications: Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
c) Column, Pillars, Piers, Abutments, Post and Struts.
d) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
e) Stairs, (excluding landings) except spiral-staircases.
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position a) Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Tolhao wood: 35 mm thick shutters
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300 x 16 mm
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. - Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a prime coat of approved steel primer. (a) M.S. tube
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : (a) udaipur green marble.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (i) Electric resistance or induction butt welded tubes.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete: (a) Precoated galvanised iron profile sheets 0.50 mm thick.
at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I,
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 ( 1 cement : 3 fine sand)
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood).
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications: Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
a) Foundation footings, bases of columns etc. and mass concrete.
b) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
c) Column, Pillars, Piers, Abutments, Post and Struts.
d) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
e) Stairs, (excluding landings) except spiral-staircases.
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position a) Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Tolhao wood: 35 mm thick shutters
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300 x 16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing bright finished brass hard drawn hooks and eyes :
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. - Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a prime coat of approved steel primer. (a) M.S. tube
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm
Marble stone flooring with 18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : (a) udaipur green marble.
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. (i) Electric resistance or induction butt welded tubes.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete: Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
P/F at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm
at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I,
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 ( 1 cement : 3 fine sand)
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood).
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications: Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
SH: Half wall Fencing with MS steel
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Column, Pillars, Piers, Abutments, Post and Struts.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
Providing, hoisting and fixing upto floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like including the cost of required centering, shuttering but excluding cost of reinforcement with a)1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size).
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. Electric resistance or induction butt welded tubes.
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coats
Applying priming coat:- With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
SH: (1) Vertical extension of Multipurpose Hall.
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Column, Pillars, Piers, Abutments, Post and Struts.
b) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
c) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
P/F aluminium works for doors windows, ventilators and partions woth extruded built up standard tubular sections/appropiate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed wihy rawl plugs and screws or with fixing clips, or with expansion hold fasteners indluding necessary filling up gaps at junctions, at top, bottom and side with required EPDM rubber/Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight. mitred and jointed mechanically wherever required including cleatangle. Aluminium snap beading for glazing/panelling, C.P. brass/Stainless steel screws, all complete as per architectural drawing and the directions of engineer-in-charge (Glazing and panelling to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15
P/F glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawing and the directions of engineer-in-charge (cost of aluminium snap beading shall be paid in basic item) With float glass panes of 4.0 mm thickness
Providing and fixing stainless steel ( SS-304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. 255 x 19 mm
P/F M.S. fan clamp type I ot II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying i/c painting the exposed portion of loops, all per standard design complete
Providing wood works in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastner shall be paid seperately).a) Local best quality Teak wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Teak wood: 35 mm thick shutters
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
P/F ISI marked oxidised M.S pressed butt hinges with necessary screws etc.
a) 125 x 65 x 2.12 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.(a) Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete: Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing wood work in frame of false ceiling partition etc. sawn and put in position. (a) Local best quality Tolhao wood
P/F insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). (a) White face insulation board 12 mm thick.
12 mm thick with cement mortar 1 : 3 (1 cement : 3 fine sand)
P/L vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all clours and shades, laid on 20 mm thick cement mortar 1 : 4 (1 c : 4 c/sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600 x 600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. i) 75 mm diameter
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content i) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/litre
Varnishing with varnish of approved brand and manufacture : i) Two or more coats glue sizing with spar varnish or an under coat of flatting varnish
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : i) Two coat
SH: (1) 3 (Three) nos Toilet block for Gents and ladies
Earth work in excavation by mechanical means (hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 dqm on plan) i/c dressing of sides and ramming of bottoms, lift upto 1.5m, i/c getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, side of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: (a) 1:4:8 (1cement:4 coarse sand: 8 graded stone aggregate 40 mm nominal size.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement - All work upto plinth level: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in beams, suspended floor, roofs having slope upto 150 landing, balconies, shelves, chajjas, lintel, abnds, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforced cement concrete work in wall (any thickness) i/c attached pillasters, buttress, plinth and string courses, fillets, columns, pillars, piers. abutments. posts and struts etc. upto floor five level but excluding the cost of centering and shuttering and reinforcement: (a)1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. a) Thermo Mechanically Treated Bars
Centering and shuttering including strutting, propping etc. and removal of form for:
a) Foundation footings, bases of columns etc. and mass concrete.
b) Column, Pillars, Piers, Abutments, Post and Struts.
c) Lintel, beams, plinth beams, girders, bressumers and centilevers, with water proof ply 12mm thick.
d) Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick.
Brick work with 1st class common burnt clay F.P.S. (non modular) brick in foundation and plinth in Cement mortar 1:4 (1cement:4 coarse sand).
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in: Cement mortar 1 : 3 (1 cement : 3 coarse sand).
Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately: (a) Local best quality Uningthou wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. a) Local best quality Tolhao wood: 35 mm thick shutters
P/F glazed shutters for doors, windows and clere story windows using 4 mm thick float glass panes including ISI marked MS pressed butt hinges bright finished of required sizes with necessary screws. Local best quality Tolhao wood. 35 mm thick
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300 x 16 mm
P/F ISI marked oxidised M.S tower bolt black finish, with necessary screws etc. complete 100x10mm
P/F aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (i)Double charge vitrified tile polished finish of size. (a) size of Tiles 600 x 600 mm
P/F 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. (i)40mm thick with 20mm nominal size stone aggregate.
12 mm cement plasterof mix 1:4 (1 cement: 4 fine sand)
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: (i) Water thinnable cement primer
Finishing walls with water proofing cement paint of required shde: New work (two or more coats applied @ 3.84 kg/10sqm).
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of HE primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture.
P/F PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (a) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
P/F white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (a) W.C. pan with ISI marked white solid plastic seat and lid
P/F wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps.
P/F mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
a) Rectangular shape 453x357 mm
P/F white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm size respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
P/F Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
(a) 40mm nominal outer dia Pipes
(a) 100mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. (Internal work - Exposed on wall)
a) 20mm nominal outer dia Pipes
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
a) 15 mm nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
a) 25 mm nominal bore.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
SH: Providing I.E.I for Academic building G+1 Arts
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Wiring for light point/power plug with 2 x 4 mm2 PVC insulated copper conductor single core cable in PVC casing and capping along with 1 no. 4 mm2 PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
Wiring for circuit/sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable in PVC casing and capping etc. as reqd.
a)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
b)2 x 2.5mm2 + 1 x 2.5mm2 Earthwire
c)2 x 4mm2 + 1 x 4mm2 Earthwire
Supply and fixing (following Modular type switch / socket) on the existing switch box/ cover i/c connection etc as req.
a)3 pin 5/6 amps socket outlet
b)5/6 amps switch
c)16 pin 15/16 amps socket outlet
d)15/16 amps switch
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd
S/f 20mm iron stapples/saddles/ screws
S/F 25 mm x 3 mm bolts & nuts
S/F 48” sweep (1200 mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regular etc as reqd. (Make Bajaj / Usha or similar)
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd
18 W LED Surface Light (Havells)
S/F LED Flood Light 100 W (Havells)
S/F (following way) single/double pole and neutral, sheet steel MCCB distribution board, 240 V on surface/recessed complete with tinned copper but bas neutral bus bar, earth bar, din bar, detachable gland plate interconnection, phosphatized and powder painted including earthing etc. as reqd. (but without MCB/RCCB/Isolator).
8 Way double door
Supplying and fixing 5 amp to 32 amp rating 230 V B series MCB for lighting and other load for (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
Single pole and neutral
S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
S/F Fire Extinguisher ABC/ Stored pressure type portable 4kg capacity (palex,getech,rainx)
10 sq.mm ISI marked, FR PVC insulated, single core copper conductor cable
S/F following PVC modular switch box with cover
18 way modules
6 way modules
4 way modules
Earthing with G.I earth pipe 4.5m long 40mm dia i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal and salt) as reqd
P/L earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia G.I. pipe as reqd.
P/F 63 Amp Main switch Compact (Legrand)
SH: Providing I.E.I for Academic building G+1 Block -I Science
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Wiring for light point/power plug with 2 x 4 mm2 PVC insulated copper conductor single core cable in PVC casing and capping along with 1 no. 4 mm2 PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
Wiring for circuit/sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable in PVC casing and capping etc. as reqd.
a)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
b)2 x 4mm2 + 1 x 4mm2 Earthwire
Supply and fixing (following Modular type switch / socket) on the existing switch box/ cover i/c connection etc as req.
a)3 pin 5/6 amps socket outlet
b)5/6 amps switch
c)16 pin 15/16 amps socket outlet
d)15/16 amps switch
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd
S/f 20mm iron stapples/saddles/ screws
S/F 25 mm x 3 mm bolts & nuts
S/F 48” sweep (1200 mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regular etc as reqd. (Make Bajaj / Usha or similar)
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd
18 W LED Surface Light (Havells)
S/F LED Flood Light 100 W (Havells)
S/F (following way) single/double pole and neutral, sheet steel MCCB distribution board, 240 V on surface/recessed complete with tinned copper but bas neutral bus bar, earth bar, din bar, detachable gland plate interconnection, phosphatized and powder painted including earthing etc. as reqd. (but without MCB/RCCB/Isolator).
8 Way double door
Supplying and fixing 5 amp to 32 amp rating 230 V B series MCB for lighting and other load for (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
Single pole and neutral
S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
S/F Fire Extinguisher ABC/ Stored pressure type portable 4kg capacity (palex,getech,rainx)
10 sq.mm ISI marked, FR PVC insulated, single core copper conductor cable
S/F following PVC modular switch box with cover
18 way modules
6 way modules
4 way modules
Earthing with G.I earth pipe 4.5m long 40mm dia i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal and salt) as reqd
P/L earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia G.I. pipe as reqd.
P/F 63 Amp Main switch Compact (Legrand)
SH: Providing I.E.I for Academic building G+1 Block -II Science
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Wiring for light point/power plug with 2 x 4 mm2 PVC insulated copper conductor single core cable in PVC casing and capping along with 1 no. 4 mm2 PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
Wiring for circuit/sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable in PVC casing and capping etc. as reqd.
a)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
b)2 x 4mm2 + 1 x 4mm2 Earthwire
Supply and fixing (following Modular type switch / socket) on the existing switch box/ cover i/c connection etc as req.
a)3 pin 5/6 amps socket outlet
b)5/6 amps switch
c)16 pin 15/16 amps socket outlet
d)15/16 amps switch
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd
S/f 20mm iron stapples/saddles/ screws
S/F 25 mm x 3 mm bolts & nuts
S/F 48” sweep (1200 mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regular etc as reqd. (Make Bajaj / Usha or similar)
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd
18 W LED Surface Light (Havells)
S/F LED Flood Light 100 W (Havells)
S/F (following way) single/double pole and neutral, sheet steel MCCB distribution board, 240 V on surface/recessed complete with tinned copper but bas neutral bus bar, earth bar, din bar, detachable gland plate interconnection, phosphatized and powder painted including earthing etc. as reqd. (but without MCB/RCCB/Isolator).
8 Way double door
Supplying and fixing 5 amp to 32 amp rating 230 V B series MCB for lighting and other load for (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
Single pole and neutral
S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
S/F Fire Extinguisher ABC/ Stored pressure type portable 4kg capacity (palex,getech,rainx)
10 sq.mm ISI marked, FR PVC insulated, single core copper conductor cable
S/F following PVC modular switch box with cover
18 way modules
6 way modules
4 way modules
Earthing with G.I earth pipe 4.5m long 40mm dia i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal and salt) as reqd
P/L earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia G.I. pipe as reqd.
P/F 63 Amp Main switch Compact (Legrand)
SH: Providing I.E.I for vertical extension of Multipurpose hall
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Wiring for light point/power plug with 2 x 4 mm2 PVC insulated copper conductor single core cable in PVC casing and capping along with 1 no. 4 mm2 PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
Wiring for circuit/sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable in PVC casing and capping etc. as reqd.
a)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
b)2 x 4mm2 + 1 x 4mm2 Earthwire
Supply and fixing (following Modular type switch / socket) on the existing switch box/ cover i/c connection etc as req.
a)3 pin 5/6 amps socket outlet
b)5/6 amps switch
c)16 pin 15/16 amps socket outlet
d)15/16 amps switch
S/F brass batten/angle holder i/c connection etc. as reqd.
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd
Sqaure box 12mm to 32mm
S/F 25 mm x 3 mm bolts & nuts
S/F 48” sweep (1200 mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regular etc as reqd. (Make Bajaj / Usha or similar)
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd
18 W LED Surface Light (Havells)
S/F LED Flood Light 100 W (Havells)
S/F 1.5 tone capacity split type Air Conditioner,Samsung
S/F (following way) single/double pole and neutral, sheet steel MCCB distribution board, 240 V on surface/recessed complete with tinned copper but bas neutral bus bar, earth bar, din bar, detachable gland plate interconnection, phosphatized and powder painted including earthing etc. as reqd. (but without MCB/RCCB/Isolator).
8 Way double door
Supplying and fixing 5 amp to 32 amp rating 230 V B series MCB for lighting and other load for (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
Single pole and neutral
S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
10 sq.mm ISI marked, FR PVC insulated, single core copper conductor cable
S/F following PVC modular switch box with cover
12 way modules
6 way modules
4 way modules
S/F 60 amp/63 amp 500 V porcelain fuse unit (Kitkat)
SH: Providing IEI for 3 (Three) nos Toilet block for Gents and ladies
Wiring for light/Fan point/ Exhaust Fan point JCall bell point with 1.5mm2 FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate suitable G.I.box and earthing the point with l.5mm2FRPVC insulated copper conductor single core cable etc.as required.
a) Group A
b) Group B
c) Group C
Wiring for light point/power plug with 2 x 4 mm2 PVC insulated copper conductor single core cable in PVC casing and capping along with 1 no. 4 mm2 PVC insulated copper conductor single core cable for loop earthing etc. as reqd.
Wiring for circuit/sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable in PVC casing and capping etc. as reqd.
a)2 x 1.5mm2 + 1 x 1.5mm2 Earthwire
b)2 x 4mm2 + 1 x 4mm2 Earthwire
Supply and fixing (following Modular type switch / socket) on the existing switch box/ cover i/c connection etc as req.
a)3 pin 5/6 amps socket outlet
b)5/6 amps switch
c) 6 pin 15/16 amps socket outlet
d)15/16 amps switch
S/F 3 pin 5 amp ceiling rose on the existing junction box / wooden block i/c connection etc. as reqd
S/f 20mm iron stapples/saddles/ screws
S/F 25 mm x 3 mm bolts & nuts
S/F 450 mm Sweep exhaust fan complete with all accessories i/c connection etc as req
S/F 12 W LED Surface Light (Philips)
S/F 1 Hp Crompton Water Pump
S/F (following way) single/double pole and neutral, sheet steel MCCB distribution board, 240 V on surface/recessed complete with tinned copper but bas neutral bus bar, earth bar, din bar, detachable gland plate interconnection, phosphatized and powder painted including earthing etc. as reqd. (but without MCB/RCCB/Isolator).
4 Way double door
Supplying and fixing 5 amp to 32 amp rating 230 V B series MCB for lighting and other load for (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd.
Single pole and neutral
S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd.
10 sq.mm ISI marked, FR PVC insulated, single core copper conductor cable
S/F following PVC modular switch box with cover
6 way modules
P/F 60 amp/63 amp 500 V porcelian fuse unit (Kitkat)
stage.html
html • 0.04 MB
techsummary_3483.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.33 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tendernotice_2.pdf
PDF • 1.64 MB
Tendernotice_3.pdf
PDF • 1.28 MB
BOQ_3483.xls
BOQ • 0.60 MB
TechnicalDrawings.pdf
Additional Documents • 1.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .