Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.4 CrAccepted-AOC 2 HOUSE NO 214 FRIENDS COLONY RAJIV NAGAR MANDI DABWALI 125104 | MANDI DABWALI | SIRSA | HARYANA | 125104 | ₹12.4 Cr Quoted ₹12.5 Cr | 1 | Accepted-AOC Accept |
| 2 | 2₹1.3 CrRejected-AOC HOUSE NO 3000 SECTOR 15 HOUSING BOARD COLONY SONIPAT 131001 | SONIPAT | SONIPAT | HARYANA | 131001 | ₹1.3 Cr | 2 | Rejected-AOC Reject |
| 3 | Rejected-Technical HSVP PANCHKULA | PANCHKULA | HARYANA | 133301 | - | - | Rejected-Technical ok |
Tender Value
₹11.2 Cr
EMD Value
₹22.4 L
Closing Date
19 Jul 2023, 3:00 pmClosed
GAURAV KANSAL
EE PHE Division No. 2 Kaithal
Rajound-Detailed Project Report of 4.50 MLD Sewerage Treatment Plant Based on SBR Technology and Sewerage Network in Rajound District Kaithal (Haryana)
2023_HRY_296428_1
20237FE24E08 EF4E 4C7E BA3D A011E3574B08595PUH
Open Tender
Civil Works
540 days
Rajound
2 documents required · 2 mandatory
₹20,000
₹22.4 L
Yes
29 Feb 2024
12 Jul 2023
19 Jul 2023
12 Jul 2023
19 Jul 2023
12 Jul 2023
Amount
Providing, Lowering, Laying, Aligning, Fixing in Position in pipe line Manually operated CI D/F Sluice Valve of approved make PN 1.0 class of following dia complete (including jointing and jointing material) including all material, labour, testing, and commissioning as per technical specifications and as per direction of engineer (500mm i/d)
Provding and Fixing of Sluice Gates Manual: 350mmx350mm Make IVC/JASH, PLC Panel, Level Sensors, Controllers, Pressure Gauges, Electro Magnetic Flow Meter with Data Logger, CC TV Camera Complete with DVR and Monitor and other accessories, Manual Screen, SS 304, 850mm wide, Wiring Cable Etc. Complete in all respect.
Supplying, installation and commissioning of Non Clog sewage submersible pumping sets fitted with effective motor, mechanical seal, thermal and mositure sensor, suspension device, anti coupling bracket, 10 m guide pipe of following duly conditions panel complete in all respects as per scope of work and specification of MPS (Non Clog Submersible Pump Set of Discharge 282 Cum /Hr 4500 LPM and 50 Meter Head) 85 BHP
Supplying erection, testing of fully automatic electric control panel board consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 4500 LPM x 50 Mtr. Head 85 HP
Construction of HT / LT Panel room, PLC room, Centrifuge house, blower room and Lab cum office building including doors, windows and fittings with toilet block including all Sanitary fittings etc. as per drawings approved by SE at MPS and STP. 500 Sqm covered area built up with RCC framed structure and brick work finished with vitrified glazed tiles flooring, powder coated aluminum frame made with 10 guage sheet having size 100mm x 45mm for chowkhat, 75mm x 45mm for door frame and 45mm x 45mm for window frame with 5mm thick glass AIS/Saint Gobain/ Modi Float including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter
Design, construction, erection, testing and commissioning of 4.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including Landscaping, MCC Panel Room, all other contingent ie. Electrical, Mechanical, Piping and Instrumentation work with PLC and SCADA arrangement for STP integrated with MPS-1, MPS-2 and MPS at STP including furniture and laboratory equipments as per detail given in the bid document and following components including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. Supply and installation 2 Nos. fine Screens of suitable size for 4.00 MLD average flow with peak factor of 3 including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED suitable size, outdoor type energy efficient lamps on each pole, 20 no. LED outdoor light with 7 m. high GI pole along road / path including all accessories complete in all respect including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. Supply and installation of 1 No. 3.65 m wide Main Gate of MS and 1.25 m. wide wicket gate at STPto the entire satisfaction of Engineer-in-charge. (Total weight not less than 500 kg) including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. Providing and installing 2 No. centrifuges (1Working plus 1 Stand bye) including centrifuge feed pump, all fittings, instrumentation, electric panel board etc. as perdesign complete in all respect including packing dry sludge in 20 Kg. bag and supplying the same in market Kisan Sewa Kendra or as directed by Engineer-in-charge within the lead as pointed at clause 4.4.4 of the DNIT including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter.
Design, construction, erection, testing and commissioning of MPS and following components: a RCC Inlet chamber, screening chamber, collecting tank, , wet well sump suitable for 4.00 MLD average flow with peak factor 3 including Providing and installing 5 no. non clog sewage submersible pump sets ie. 2 No. of 166.66 M3/hr, 500 M3/hr 1 No. and 83.33 M3 /hr 2 No having minimum head of 15 m, equipped with suitable LT panel boards, all safety devices, automatic capacitor bank and suitable size submersible cable from LT panel to pumps complete in all respect including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. b K9 DI pipe of suitable dia at MPS including welding and screwing of flanges, ISI marked D.I. fittings, sluice valves, non returning valves as per requirements even for bye-pass arrangements complete in all respect including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. c 3 Nos. CI Gear Operated Sluice Gate with SS Spindle (SS 410) and seats (SS 304) (2 nos. for screen and 1 no. for partition of collecting tank) as per design including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. d Supply and installation of 2 mechanical coarse screens suitable for for 5.50 MLD average flow with peak factor of 3.0 complete in all respect including OandM during Defect liability period of 12 months after trial run period of 3 months and 5 years thereafter. e Entire infrastructure except construction of staff quarter, Boundary wall, path ways / roads and work covered under Schedule -1A (HSR - Items) required to be executed at site to make the MPS functional is included in the scope of work for lump-sum job. f All the pumping machinery, panel board, Level sensor etc shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at MPS and STP site through broadband internet facility. g Raw sewage will be available near boundary wall within the premises of proposed STP but the conveyance of sewage through DI pipe of suitable diameter, from this terminal point to the receiving Chamber of the MPS is included in the Turnkey contract. The Level of the MPS / STP will be as per bed level of existing incoming sewer at MPS. h The size and quantities of all the above components will be as per approved structural/ Hydraulic / Mechanical/ Electrical design to be approved by Departmental before actual execution of work.
Bidder Name
Amount
Jaiveer Singh Contractor(GSTN-06ATQPS8420H1Z8)
M/s Sourabh Construction Pvt. Ltd.(GSTN-NA)
Jaiveer Singh Contractor
Jaiveer Singh Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.