Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹13.7 L+₹2.2 L (19.6%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹14.1 L+₹2.7 L (23.5%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹14.5 L+₹3.0 L (26.5%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹14.8 L+₹3.3 L (29.0%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
28 Sept 2021, 6:00 pmClosed
Sh Himanshu
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2021_MES_471708_1
GE(S)/PAT-35/S/2021-22
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Sangrur
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (S) Patiala
₹38,000
Yes
23 Oct 2021
31 Aug 2021
30 Sept 2021
31 Aug 2021
28 Sept 2021
14 Sept 2021
31 Aug 2021 - 7 Sept 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out as directed.
Returning filling in including spreading leveling, watering and well ramming in layers.
Removing excavated soil to a distance not exc. 50 mtr and depositing where directed.
M&L for sand cushioning with dry and clean over and under the cable, 80 mm sand laid before laying and 150 mm after laying the cable complete all as specified & directed.
S&F GI tube light grade 80 mm dia complete all as specifed & directed.
Supply and laying best quality bricks locally availanle sub class ‘B’ bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as specified & directed.
Taking up steel tubing 40 mm dia complete all as specified and directed.
Taking out PVC insulated LT electric cable with aluminium conductor of any size and description from panels/ poles/ trenches/ pipe/ duct etc setting aside for measurement meant for credit purpose complete all as specified and directed.
Supply, installation, commissionning and testing of outdoor LT panel board kiosk type made out of CRCA sheet 3.15 mm thick vermin proof factory made CPRI approved, with copper bus bar of capacity 800 Amps for 3 phase and neutral with necessary angle iron 50 x 50 x 6 mm support frame including two coats powder painting over a coat of red oxide primer and grout in PCC complete all as specified and directed comprising of the followings:- (A) INCOMING : (a) MCCB 415 V, 500 A, 4 pole with over load , short circuit and earth fault protection with earth module breaking capacity 35 KA-01 No (b) Multi function meter for measuring V,A,F,kW,KVA etc (c) Indicator lamps RYB LED type(Set of Three)-01 No (d) CT coils 400/5 A-03 Nos (B) OUTGOING : (a) MCCB 125 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 35 KA - 03 Nos (b) MCCB 100 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA - 03 No (c) MCCB 63 A, 415 V , 4 pole with over load short circuit protection, breaking capacity 25 KA - 03 No (d) MCCB 40 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA -02 Nos (e) Wiring of above accessory with suitable size of copper conductor cable Note :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. The rate be inclusive of taking down old LT Panel Board.
Supply , installation, commissionning and testing of outdoor LT feeder pillar kiosk type made out of CRCA sheet 3.15 mm thick vermin proof factory made CPRI approved, with copper bus bar of capacity 200 Amps for 3 phase and neutral with necessary angle iron 50 x 50 x 6 mm support frame including two coats powder painting over a coat of red oxide primer and grout in PCC complete all as specified and directed comprising of the followings:- (A) INCOMING : (a) MCCB 125 A, 415 V , 4pole with over load short circuit protection, breaking capacity 35 KA - 01 No (b) Multi function meter for measuring V,A,F,kW,KVA etc (c) Indicator lamps RYB LED type(Set of Three)-01 No (d) CT coils 400/5 A-03 Nos (B) OUTGOING : (a) MCCB 63 A, 415 V , 4 pole with over load short circuit protection, breaking capacity 25 KA-02 Nos (b) MCCB 40 A, 415 V , 4 pole with over load short circuit protection, breaking capacity 25 KA-02 No (c) MCCB 32 A, 415 V , 4 pole with over load short circuit protection, breaking capacity 25 KA-02 No (d) Wiring of above accessory with suitable size of copper conductor cable Note :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. The rate shall be inclusive of taking down old Feeder Pillar.
Supply, installation, commissionning and testing of indoor LT panel board made out of CRCA sheet 2.15 mm thick vermin proof factory made CPRI approved, with copper bus bar of capacity 200 Amps for 3 phase and neutral with necessary angle iron 50 x 50 x 6 mm support frame including two coats powder painting over a coat of red oxide primer and grout in PCC complete all as specified and directed comprising of the followings:- (A) INCOMING : (a) MCCB 160 Amps Four pole 35 KA -01 No (b) Multi function meter for measuring V,A,F,kW,KVA etc (c) Indicator lamps RYB LED type(Set of Three)-01 No (d) CT coils 400/5 A-03 Nos (B) OUTGOING : (a) MCCB 125 A, 415 V , 4 pole, breaking capacity 35 KA (b) MCB DP 6-32 Amps (c) Single phase preventer (d) Phase indicator lamp-01 set of three (e) Onload change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amp (f) Wiring of above accessory with suitable size of copper conductor cable (g) Starter of suitable size complete fixed in panel for 40 HP three phase submersible motor Note :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. The rate shall be inclusive of taking down old LT Panel Board.
Supply , installation, commissionning and testing of outdoor LT feeder pillar kiosk type made out of CRCA sheet 3.15 mm thick vermin proof factory made CPRI approved, with copper bus bar of capacity 100 Amps for 3 phase and neutral with necessary angle iron 50 x 50 x 6 mm support frame including two coats powder painting over a coat of red oxide primer and grout in PCC complete all as specified and directed comprising of the followings:- (For High Masts) (A) INCOMING : (a) MCCB 40 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA-01 No (b) Indicator lamps RYB LED type(Set of Three)-01 No (B) OUTGOING : (a) MCCB 32 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA-01 No (b) MCB DP 6-32 A -01 No (c) Wiring of above accessory with suitable size of copper conductor cable Note :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. The rate inclusive of taking down old LT Feeder Pillar
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earthpit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level , connected to galvanised earth strip 32x6 mm thick by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No -4 connected to machinary /panel complete including PCC pit in PCC(1:3:6) type C-1, pre cast RCC(1: 1 1/2:3) nominal mix cover slab reinforced with 8 mm dia mild steel deformed bar 15cc and suitable handle of 10 mm Dia round bar including necesary excavation earth work in soft/loose soil and disposal of soil to a distance n.exc 50m all as specified & directed by Engr in Charge.
Supply, laying, connecting and testing of cable XLPE /PVC insulated armoured and sheathed LT 1100 volts grade with aluminium conductor of following size complete all as specified and directed.
300 sqmm 3½ core.
240 sqmm 3½ core.
185 sqmm 3½ core.
120 sqmm 3½ core.
70 sqmm 3½ core.
50 sqmm 3½ core.
35 sqmm 3½ core.
25 sqmm 4 core.
16 sqmm 4 core.
10 sqmm 4 core.
10 sqmm 2 core.
6 sqmm 2 core.
R D Bansal
The Rahul Vig
NARINDER KUMAR SONS
AR CONSTRUCTIONS
Arneja Builders
UNITED ENGINEERING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .