Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC L1 |
Tender Value
₹2.5 Cr
EMD Value
₹4.9 L
Closing Date
19 Mar 2020, 9:00 amClosed
Raja Nagender Singh
XEN(E) Gurugram
CONSTRUCTION OF FLATS FOR OFFICERS AT GURUGRAM (BOQ FOR THE WORK PDG. E.I. AND ESTATE SERVICES) PHASE - 1
2020_HRY_123746_1
Construction of flats of Officers in Officer Colon
Open Tender
Electrical Works
Works
180 days
XEN(E) Gurugram
Refer DNIT
3 documents required · 3 mandatory
₹20,000
Executive Engineer,Electrical Division
₹4.9 L
27 Aug 2020
14 Mar 2020
19 Mar 2020
14 Mar 2020
19 Mar 2020
14 Mar 2020
Amount
Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. (Make : Grandlay,Havells, Polycab,R.R. Kabel of approved make list) Size 1.50 sqmm ( 48 / 0.20mm).
Suply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. Make L&T, ABB, Havells & Standard 15 amp.to 60 amp. 415 V ,10 KA 3-phase.
100 amp.to 220 amp.415 V,10 KA 3-phase.
250 amp. 415 V , 35 KA 3-phase.
Suply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. Make L&T, ABB, Havells & StandardS.P.N. enclosure for single pole MCB 20 amp.
Blanking sheet .Suply and erection of blanking sheet in existing distribution board.
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. Make L&T, ABB, Havells & StandardMiniature circuit breakers of 9 KA breaking capacity.SP MCB 6 Amp. to 32 Amp.
SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp.
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.
Supply and erection of Fittings and Accessories.Bakelite angle / straight button holder large size.
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job.
Making suitable hole in the wall upto 450 mm sweep exhaust fan including finishing the same and fixing of wire mesh duly fixed with Deodar wood frame of section 40 mm x 25 mm thick.
Pdg. and fixing of equired size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep.
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Make Jindal, Prakash, Ravindra, TataHeavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness flushed.
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. make AKG, Diplast, PolypackPVC pipe 65 mm dia.
Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as equired.
Extra for using salt and charcoal / coke for pipe earth electrode as equired.
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) comlete as equired.
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode.
Suplying and laying of 6 S.W.G. G.I. wire at 0.50 metre below ground level as conductor earth electrode including thimbles, soldering etc. as equired .
Suplying and laying of 25 mm x 5 mm G.I. Strip at 0.50 metre below ground level as strip earth electrode including soldering etc. as equired.
Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required .
Pdg. and laying earth connections from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode as required .
Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material.
Pdg. and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required .
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refiling of trenches. (Make : Grandlay,Havells, Polycab,R.R. Kabel) 16 Sq. mm 4 Core Ard. Cable .
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections. (Make : Grandlay,Havells, Polycab,R.R. Kabel ) 240 Sq. mm 3.5 Core Ard. Cable .
185 Sq. mm 3.5 Core Ard. Cable .
150 Sq. mm 3.5 Core Ard. Cable .
95 Sq. mm 3.5 Core Ard. Cable .
70 Sq. mm 3.5 Core Ard. Cable .
50 Sq. mm 3.5 Core Ard. Cable .
35 Sq. mm 3.5 Core Ard. Cable .
16 Sq. mm 4 Core Ard. Cable .
10 Sq. mm 4 Core Ard. Cable .
6 Sq. mm 4 Core Ard. Cable .
Suply and erection of suitable compression type brass cable glands for underground Cable. Up to 6 sqmm Cable 2 to 4 core.
10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core .
120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core
240 Sqmm Cable 3 to 3.5 Core .
300 Sq mm to 400 Sqmm Cable 3 to 3.5 Core .
Supply and erection of 75 mm x75 mm x 60 mm deep M.S.box for telephone and inter-communication system including 2 pin 5 amp. socket including cost of bakelite sheet .
Supply & erection of PVC unsheathed copper conductor cbale single core 1100 volts grdae in pipe of suitable size excluding cost and erection of pipe. (Make : Grandlay,Havells, Polycab,R.R. Kabel ) Cable size 1.5 Sqmm (3/0.81 mm )
Cable size 4 Sqmm ( 7/0.85 mm ).
Size 6 sqmm (7/1.05 )
Cable size 10.0 sq.mm(7/ 1.05 mm)
Cable size 16.0 sq.mm(7/ 1.05 mm)
Suply and erection of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material equired to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make L&T, ABB, Havells & Standard8 way SP&N (Horizontal)
12 way SP&N (Horizontal)
Suply and erection of double door/four pole residual current circuit breaker(RCCB/ELCB) suitable for operation on 240/415 V 50 HZ, AC Suply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material equired to complete the job in all respect upto entire satisfaction of Engineer-in-charge of work. Make L&T, ABB, Havells & Standard25 A/240 V DP ELCB with 100 mA sensitivity
40 A/240 V DP ELCB with 100 mA sensitivity
63 A/240 V DP ELCB with 100 mA sensitivity
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. (Make : AKG,DIPLAST,POLYPACK) 25 mm dia.
Supply and erection of M.S Saddles and clamps on wall/RCC parapit for fixing the under ground cable at a distance of .60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect.
Providing and fixing modular type accessories of approved make in existing boxeincluding fixing and making necessary connection, complete in all respect.Bell Push
Fan Regulator
Call bell Ding-Dong (Monica)
Blanking plate.
Suply , erection, testing and commissioning of wall / free standing floor mounting dust and vermin proof compartmentalized cubical Panel made out of 2.0 mm thick CRCA sheet, equired hardware, 3mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel, dully painted by 2 coat of zinc / Red oxide primer followed by 2 coats of powder coating in grey or equired shade after rinsing. The panel having PU/ Neoprene ruBus Barer gasket of not less than 3 mm thickness, separate detachable gland plate MS base channel, hinged door with inter locking arrangemrnt for equipment / switch gear, Transparent acrylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bars. Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra items. Side walls and cable alley compartments shall be having bolted type doors with detachable extension type structure. The panel will be complete with control wiring ( copper) and fuse protection. ( only outer area on all sides shall be measured).
Suply and erection of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in equired size and shape and insulation with colour coading heat shrinkable PVC sleeves complete in all respect upto entire satisfaction of Engineer-in-charge of work.
Suply & fixing of rotary handle for on / off operation of existing MCCB in the LT panel including fixing the same in position with all labour and material equired to complete the job in all respect Make L&T, ABB, Havells & StandardRotary handle up to 125 A, MCCB
Rotary handle above 125 A, MCCB
S/E of ISI mark double walled corrugated (DWC) HDPE pipe laid 1 mtr. Below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material equired to complete the job in all respect upto the entire satisfaction of Engineer-In- Charge of the work. HDPE pipe 63/50 mm outer dia/ inner dia.
HDPE pipe 90/75 mm outer dia/ inner dia.
Supply and errection of Hot Dip Galvanized octagonal pole 3 mm thickness, with base plate including of nut and bolts and all accessories as supplied by the manufacture including cost of foundation accessories etc. The foundation bolts as per manufacturer design should be hot dipped galvanized pole complete of 2 nos. 100 A, 4 pole nature links including connection etc with suitable connection arrangements for 2 no. MCB/ kit kat including cost of RCC 1:1:5:3 for foundation of size 0.7 m x 0.7m x 1.8 m with minimum 8 Nos. 12 mm dia longitudinal MS reinforcement rods with rings of 8 mm dia not more than 200 mm CC for fixing the pole with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work.(Make : Philips,Bajaj, GE India,Surya Roshni) 7 Mtr. Long pole with top dia 70 mm and bottom dia 130 mm with base plate of size 220 x 220 x 12 mm
Suply and erection of moulded case circuit breaker single pole/ 4 pole on wall/ on existing pedestal including bounding to earth and making necessary connection equired to complete the job the job in all respect up to the entire satisfaction of the Engineer -in - Charge of the work. Make L&T, ABB, Havells & Standard4 pole MCCB 63 amp.
4 pole MCCB 100 amp.
4 pole MCCB 200 amp.
Suply and erection of heavy duty 4 pole ON load changeover load breaker switch comprising of switches 63 amp. To 100 amp. Suitable for operation on 415 V 50 Hz AC Suply complete with handle assembly having door interlook & padlocking arrangemrnt on existing panel/ including making necessary connections with petty material equired to complete the job. Make L&T, ABB, Havells & Standard200 amp. 4 pole ON load changeover switch
Supply and laying of multicore telephone cable conductor size 0.5 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/ Channel and making necessary connection complete in all respect upto the entire satisfaction of the Engineer -in- Charge of the work.2 pair telehone wire
S/E/T/C of RG-11 COAXIAL cable in existing PVC pipe/ channel complete in all respect with all labour and material required to complee the job in all respect
Suply & erection of cable tray made out of 2 mm thick galvanised perforated sheet steel including erection of the same on wall or ceiling with necessary fixture and other material equired to complete the job in all respect upto the entire satisfaction of Engineer - in - Chage of the work. 40 x 100 mm
Supply and erection of factory manufactured general purpose enclosure suitable for installation of three/four pole single MCCB upto 250/400 amp. Current rating. The enclosure should be duly powder coated painted complete with necessary nuts and bolts required for fixing the enclosure on wall with all labour and material required to complete the job in all respect. Make L&T, ABB, Havells & Standard100 amp.
Supply and erection of load line i.e. double door TPN vertical distribution board suitable for MCCB as incommer on existing angle iron board / on wall / in pedestal including making nacessary connection with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work. Make L&T, ABB, Havells & Standard8 way Double door TPN distribution board suitable for 100 amp. 4 pole MCCB but without cost of MCCB.
Supply and erection of single arm bracket made of 50 mm dia G.I pipe B class ISI 1.5 mtr. long with 25 mm dia G.I. bottom pipe with 75 mm dia 60 cm. long G.I. collar pipe, top covered with ornamental cap duly welded, painted 2 coats of aluminium paint on bracket and golden paint on ornamental cap including erection of same with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In - charge of work.Single side G.I street light bracket(as per standard specifications of manufacturer of GI octagonal pole).
Supply and erection of 70/72 watts LED street light fittng dia cast aluminium housing, illumination of 110 lumens per watt, IP 66, including erection of same on pole with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge. Make Crompton LSTP-72-CDL or equivalent model of Bajaj/ Philips/ Wipro/Surya Roshini/ C&S ElectricPVC Insulated wiring in recessed conduit.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular inner and outer plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with all labour, material, chasing, refelling of walls complete in all respect upto entire satisfaction of Engineer in Charge .Light Point/Exhaust PointShort Point
Medium Point .
Long Point .
Fan Point Medium Point .
Long Point .
Twin control light point with 2 way 5 amp. single pole switchShort Point
Long point.
Call bell point including M.S box of size 180 mmX100 mmX 60 mm deep for Call bell Long point
3 pin 5 amp. plug point including earthing the 3rd. pin etc.Short point.
Medium point.
Long point.
3 pin 15 amp. plug point with 4 sq mm PVC insulated copper conductor cable including earthing the 3rd. pin etc. Long point.
Supply and fixing of the following sheet steel clad wall / recess / floor mounting telephone tag block constructed from 14 SWG sheet steel, finished with powder coated paint, with hinged gasketted door and complete with adequately rated and sized telephone terminal block to receive incoming and outgoing wires etc. as required. 10 Pair
Supply installation testing and commissioning of 800 Amp. 4 pole 50KA microprocesser based manual drawout type ACB including cost of under voltage release, rotary handle, shunt trip and closing coil including making necessary connection with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer -in- charge of the work. Make L&T, ABB, Havells & Standard
Supply & erection of A.C. ceiling fan Size of ceiling fan 48" (1200mm) sweep complete blade, canopy and downrods etc. and other material equired to complete the job in all respect upto the entire satisfaction of Engineer - in - Chage of the work. (Make : Bajaj,Crompton,Khaitan,Orient,Havells)
Supply & erection of A.C. ceiling fan Size of ceiling fan 56" (1400mm) sweep complete blade, canopy and downrods etc. and other material equired to complete the job in all respect upto the entire satisfaction of Engineer - in - Chage of the work. (Make : Bajaj,Crompton,Khaitan,Orient,Havells)
Supply & erection of none matelic exhaust fan 250 mm size medium duty and other material equired to complete the job in all respect upto the entire satisfaction of Engineer - in - Chage of the work. (Make : Bajaj, Crompton, Khaitan, Orient, Havells)
Supply & erection of 1x 18 LED fitting with other material equired to complete the job in all respect upto the entire satisfaction of Engineer - in - Chage of the work. (Make : Bajaj,Crompton,Havells,C&S Electric)
Supply and erection of surface mounted 12 watt LED light complete with all labour and material required to complete the job in all respect upto entire satisfaction of Engineer - In- Charge. (Make : Bajaj,Crompton,Havells,C&S Electric)
Supply, erection, testing and commissioning of machine room less electric traction passenger elevator of OTIS / KONE / MITUSUBISHI / KINETIC HUNDAI/ SCHINDLER/ HITACHI / JOHNSON/ ORBIS make suitable for 13 persons (884 kg. weight) having speed @ 1 meter per second to travel from ground floor + 6 upper floors with 7 stops, 7 opening on same side with ARD system and full height infra red safety as per technical specifications attached upto the entire satisfaction of the Engineer-in-charge of work.
Supply, erection, testing and commissioning of machine room less electric traction passenger elevator of OTIS / KONE / MITUSUBISHI / KINETIC HUNDAI/ SCHINDLER/ HITACHI / JOHNSON/ ORBIS make suitable for 13 persons (884 kg. weight) having speed @ 1 meter per second to travel from ground floor + 5 upper floors with 6 stops, 6 opening on same side with ARD system and full height infra red safety as per technical specifications attached upto the entire satisfaction of the Engineer-in-charge of work.
Supply, erection, testing and commissioning of machine room less electric traction passenger elevator of OTIS / KONE / MITUSUBISHI / KINETIC HUNDAI/ SCHINDLER/ HITACHI / JOHNSON/ ORBIS make suitable for 13 persons (884 kg. weight) having speed @ 1 meter per second to travel from ground floor + 3 upper floors with 4 stops, 4 opening on same side with ARD system and full height infra red safety as per technical specifications attached upto the entire satisfaction of the Engineer-in-charge of work.
Supply, erection, testing and commissioning of machine room less electric traction passenger elevator of OTIS / KONE / MITUSUBISHI / KINETIC HUNDAI/ SCHINDLER/ HITACHI / JOHNSON/ ORBIS make suitable for 13 persons (884 kg. weight) having speed @ 1 meter per second to travel from ground floor + 1 upper floor with 2 stops, 2 opening on same side with ARD system and full height infra red safety as per technical specifications attached upto the entire satisfaction of the Engineer-in-charge of work.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .