Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC 3 1ST FLOOR SRINIDHI BUILDING SM ROAD T DASARAHALLI BANGALORE 560 057 | BENGALURU URBAN | KARNATAKA | 560057 | L1 | Accepted-AOC AOC | |
| 2 | L2₹15.3 L+₹18,568.84 (1.23%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹16.5 L+₹1.4 L (9.25%)Rejected-Finance 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹15,200
Closing Date
12 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(South) Bangalore
GE(South) Bangalore
REPAIR MAINT OF LT DISTRIBUTION SYSTEM FOR ZONE F, G, H, J K AREA UNDER GE (SOUTH) BANGALORE
2023_MES_621624_3
8748/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
As per tender document
6 documents required · 6 mandatory
₹500
GE(South) Bangalore
₹15,200
Yes
26 Feb 2024
22 Jan 2024
14 Feb 2024
22 Jan 2024
12 Feb 2024
29 Jan 2024
Amount
Excavation in trenches in Soft/ loose soil not exceeding 1.5 M wide and not exceeding 1.5 M in depth for laying of UG cables and LT Panel board foundation etc and complete all as specified and directed .
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil.
Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point all as directed.
M&L for sand cushioning in trenches for bricks of u/g cable with coarse sand laid dry in trenches with uniform thickness.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection all as specified and directed.
Material & Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Material & Labour for PCC 1:3:6 type D2 (using 20mm graded stone aggregate) as in foundation, mass concrete for road crossing etc., complete all as specified and directed.
Taking down old unserviceable service cable 10/6 sqmm 2 core
S&F 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, 6 Sqmm twin core served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, One twin core cable flat or circular
All as per item No 9 but of size 10 Sqmm twin core.
Taking down old unserviceable XLPE UG Cable form site any size any capacity
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium sonductor of size 10 Sqmm x 2 core complete all as specified and directed.
All as per Item No 12 but of size 16 Sqmm x 4 Core
All as per Item No 12 but of size 25 Sqmm x 3.5 Core
All as per Item No 12 but of size 35 Sqmm x 3.5 Core
All as per Item No 12 but of size 50 Sqmm x 3.5 Core
All as per Item No 12 but of size 70 Sqmm x 3.5 Core
All as per Item No 12 but of size 95 Sqmm x 3.5 Core
All as per Item No 12 but of size 120 Sqmm x 3.5 Core
All as per Item No 12 but of size 150 Sqmm x 3.5 Core
Labour only for Re-Laying fixing or passing through pipe only LT 1100 Volts grade Underground cable of any size incl connections from LT panel board of size 50 to 120 Sqmm all as specified and directed by Engr-in-Charge.
M&L for Breaking road, pavement, hard standing, tiles of any type, including excavation of subbase, soil upto the depth of 0.60 mtr and width 0.45 mtr by mechanical means for fault finding in water pipe lines and including making good to the disturbed surfaces matching with existing after rectification of fault including removal of surplus material to nearby dumping point complete all as specified and directed by Engr-In-Charge. Note:(i) Any T&P required for work is deemed to be included in quoted rates. (ii) Tiles, cement concrete etc. required for making good is deemed to be included in quoted rates.
S&F for post insulator for fixing of aluminium strip on wall for safety purpose complete all as per specified and directed
Supply and fixing Aluminium strip of size 25x3.15mm incl epoxy/porcelain insulators of suitable size , distance between insulators not more than 1mtr including fixing screws washers etc complete for
Dismnaling of old unserviceable GI Pipe of capacity 80/100mm dia
Supply and lay pipe galvanized light grade including fittings 40mm dia for cable protection using road crossing etc.
All as per Item No 26 above but of size 80mm dia
Material & Labour for LT straight through joint for under ground cable for 3 ½ / 4 Core upto 50 sqmm all as specified and directed.
All as per Item No 28 but of size 70 Sqmm x 3.5 Core
All as per Item No 28 but of size 95 Sqmm x 3.5 Core
All as per Item No 28 but of size 150 Sqmm x 3.5 Core
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete.
Dismanling olf old unserviceable GI Bracket from Pole any size any dia
M&L for GI bracket for street light fittings 32mm dia 1.2Mtr length including D/C clamps for PCC/Steel pole round or square nut bolt and washers etc and painiting of bracket and clamps all as specifiedf and directed by Engr in Charge
Dismantling of old unserviceable street light fitings/driver any size any capacity
Supply and fix LED security light fittings aesthetically designed roadway luminaire with excellent thermal management complete 35/45Watt IP 66 complete all as specified and directed.
S&F of LED street light fittings driver for various capacity 45/60/90Watt for various make all as specified and directed by engr in Charge .
Dismantling old unserviceable Junction Box any size capacity
Supply and fixing junction box suitable for IP 65, for and including terminal block 32 Amps trminating LT cable of size up to 16 Sqmm fabricated of thermoplastic complete with gaskets , gland for cable entry and locking arrangement including mounting arrangement for pole complete all as specified and directed .
Supply and fixing junction box suitable for IP 65, for and including terminal block 32 Amps trminating LT cable of size up to 16 Sqmm fabricated of thermoplastic complete with gaskets , gland for cable entry and locking arrangement including mounting arrangement for poleincluding ON/OFF switch and mounting bracket clamp suitable size as per site with nut bolt washer complete all as specified and directed.
Dismanling old unserviceable of MCB/MCCB any type any capacity
S&F of MCCB 3 pole 415 volt fixed type of capacity 400 Amps with breaking capacity 36 KA
S&F of MCCB 3 pole 415 volt fixed type of capacity 250 Amps with breaking capacity 36 KA
S&F of MCCB 3 pole 415 volt fixed type of capacity 200 Amps with breaking capacity 25 KA
S&F of MCCB 3 pole 415 volt fixed type of capacity 160 Amps with breaking capacity 25KA
S&F of MCCB 3 pole 415 volt fixed type of capacity 125 Amps with breaking capacity 16 KA
S&F of MCCB 3 pole 415 volt fixed type of capacity 100 Amps with breaking capacity 16 KA
S&F of MCCB 3 pole 415 volt fixed type of capacity 63 Amps with breaking capacity 16 KA
S&F MCB TPN 40 Amp capacity three phase 425 volt 50 Hz
S&F MCB TPN 63 Amp capacity three phase 425 volt 50 Hz
Taking down old unserviceable form pole PVC Conduit and PVC Copper wire
S&F PVC Conduit pipe from PVC Junction Box to street light bracket for protection of cable fixing clamp on PCC poles drilled the hole and insert a PVC gutti and screwed suitable size screw and fix the clamp
S&F PVC 3 Core copper cable 1.5Sqmm insulated for fixing of junction box as approved street light fittings complete all as specified and directed
Dismantling of old unserviceable feeder pillar box any size any capacity
Supply, testing, commissioning for Feeder pillar box made out door type of copper bus bar of 400A capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.0mm thick, CRCA sheet, angle iron frame of size 40x40x6mm including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform etc complete all as specified and directed
S&F Aluminium thimbles for end connection for suitable for cable size 120Sqmm to 150 Sqmm tightned with suitable crimping tools along with connecting accessories ie nut bolt washers etc complete all as specified and directed by Engr in Charge.
All as per Item No -56 but size 70 to 90 Sqmm
All as per Item No -56 but size 25 to 50 Sqmm
All as per Item No -56 but size up to 16 Sqmm
GS TRADERS
Vasavi Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .