| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23,155Accepted-Finance | L1 | Accepted-Finance Qualified | |
| 2 | L2₹27,157+₹4,002 (17.3%)Accepted-Finance | L2 | Accepted-Finance Qualified | |
| 3 | L3₹27,847.50+₹4,692.50 (20.3%)Accepted-Finance | L3 | Accepted-Finance Qualified |
| Sl No | Description | Qty | Unit | SHREE BALA JI ELECTRICALS L2 | C B S ENTERPRISES L3 | A K ELECTRICAL ENG WORKS L1 |
|---|---|---|---|---|---|---|
| 0.00d | ||||||
| 1.00Carriage of followings from ESC. BSR to pit site on kachcha pakka road including loading and unloading chagres at both ends, requird for proper completion of work, distance about to 60 Kms. | ||||||
| 2.00 | PCC Pole from E.S.C Bulandshahr to Site. | 1 | Nos. | 990 ₹990 | 1,000 ₹1,000 | 790 ₹790 Lowest |
| 3.00 | Carriage of All line Material from store to j.e store Sub station as ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc. | 1 | Qtl. | 550 ₹550 | 600 ₹600 | 345 ₹345 Lowest |
| 4.00 | Erection of Single support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 1 | Nos. | 1,540 ₹1,540 | 1,580 ₹1,580 | 1,445 ₹1,445 Lowest |
| 5.00 | Erection & Grouting of Double Pole including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 1 | Nos. | 7,600 ₹7,600 | 7,750 ₹7,750 | 6,900 ₹6,900 Lowest |
| 6.00 | Grouting of Single support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of cement, sand, brick ballast/stone ballast, etc. required for proper completion of work. | 1 | Nos. | 1,050 ₹1,050 | 1,100 ₹1,100 | 850 ₹850 Lowest |
| 7.00 | Laying, sagging. Stringing and binding and jumpering of ACSR Weasel conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work. | 1 | Mtr. | 16 ₹16 | 16.5 ₹16.5 | 14 ₹14 Lowest |
| 8.00 | Laying, sagging. Stringing and binding and jumpering of ACSR Rabbit conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work. | 1 | Mtr. | 16 ₹16 | 17 ₹17 | 14 ₹14 Lowest |
| 9.00 | Fixing of Stay rod with Stay wire in proper way with Nozelling. | 1 | Nos. | 500 ₹500 | 550 ₹550 | 400 ₹400 Lowest |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
26 Feb 2026, 11:00 amClosed
SE, EDC-II, BULANDSHAHR.
SE, EDC-II, BULANDSHAHR.
Under EDD-Syana, Bulandshahr, on the basis of rate contract, work like straightening of crooked poles and replacement of damaged poles etc. in emergency situations.
2026_PVVNL_1117856_1
T-67/EDC-II/BSR/25-26
Open Tender
Electrical Works
Lump-sum
30 days
BULANDSHAHR
Under EDD-Syana, Bulandshahr, on the basis of rate contract, work like straightening of crooked poles and replacement of damaged poles etc. in emergency situations.
2 documents required · 2 mandatory
₹1,180
SE, EDC-II, BULANDSHAHR
₹5,000
Yes
6 Mar 2026
18 Feb 2026
26 Feb 2026
18 Feb 2026
26 Feb 2026
18 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | d | - | - | - | - |
| 1 | Carriage of followings from ESC. BSR to pit site on kachcha pakka road including loading and unloading chagres at both ends, requird for proper completion of work, distance about to 60 Kms. | - | - | - | - |
| 2 | PCC Pole from E.S.C Bulandshahr to Site. | 1 | Nos. | 1 | ₹1 |
| 3 | Carriage of All line Material from store to j.e store Sub station as ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc. | 1 | Qtl. | 1 | ₹1 |
| 4 | Erection of Single support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 1 | Nos. | 1 | ₹1 |
| 5 | Erection & Grouting of Double Pole including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. | 1 | Nos. | 1 | ₹1 |
| 6 | Grouting of Single support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of cement, sand, brick ballast/stone ballast, etc. required for proper completion of work. | 1 | Nos. | 1 | ₹1 |
| 7 | Laying, sagging. Stringing and binding and jumpering of ACSR Weasel conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work. | 1 | Mtr. | 1 | ₹1 |
| 8 | Laying, sagging. Stringing and binding and jumpering of ACSR Rabbit conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work. | 1 | Mtr. | 1 | ₹1 |
| 9 | Fixing of Stay rod with Stay wire in proper way with Nozelling. | 1 | Nos. | 1 | ₹1 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
67NIT.pdf
Tender Documents • 1.16 MB
BOQ_2077343.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .