Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC AT JAGAPUR ROAD WARD 01 PO DASAPALLA DIST NAYAGARH PIN 752084 | DASAPALLA | NAYAGARH | ODISHA | 752084 | ₹2.8 Cr | L1 | Accepted-AOC Selected in Transparent lottery System |
| 2 | L1₹2.8 CrRejected-AOC | ₹2.8 Cr | L1 | Rejected-AOC Rejected in Transparent lottery System |
| 3 | L1₹2.8 CrRejected-AOC | ₹2.8 Cr | L1 | Rejected-AOC Rejected in Transparent lottery System |
| 4 | L1₹2.8 CrRejected-AOC AT BARIMAL PO HATIBARI PS SUKINDA DIST JAJPUR PIN 755018 | JAJAPUR | ODISHA | 755018 | ₹2.8 Cr | L1 | Rejected-AOC Rejected in Transparent lottery System |
| 5 | L1₹2.8 CrRejected-AOC AT PO KRUSHNA CHANDRAPUR PATNA DASAPALA DIST NAYAGARH | DASAPALA | NAYAGARH | ODISHA | ₹2.8 Cr | L1 | Rejected-AOC Rejected in Transparent lottery System |
Tender Value
₹3.2 Cr
EMD Value
₹3.2 L
Closing Date
15 Jan 2026, 5:00 pmClosed
Chief Construction Engineer
Office of CCE, Brutang and Hadua Irrigation Project Dasapalla
Construction of D type Quater (Block B) of Brutanga and Hadua Irrigation Project at Dasapalla Irrigation Colony District Nayagarh (Civil PH Electrical)
2025_CCEBH_123765_1
CCE-BHIP-BID-04(03)/2025-26 Dt.16 .12.2025
National Competitive Bid
Civil Works - Buildings
Percentage
Dasapalla
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹3.2 L
Yes
9 Apr 2026
24 Dec 2025
16 Jan 2026
24 Dec 2025
15 Jan 2026
24 Dec 2025
Earth work in excavation of foundation trenches in all kinds of soil including moorum stoney earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and leveling the bed upto the required depth and depositing the excavated materials away from the work site with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.
Supplying, Diluting & Spreading Chemical Emulsion like CHLORPYRIPHOS OR Other Chemical approved by the Central Insecticides Board as directed by the manufacturer and spraying the mixture uniformly by the sprayer as preconstructional antitermite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. complete at the rate of 7.5 litres (or as directed by the manufacturer) per sqm on vertical and 5.0 litres per sqm on horizontal surfaces, 50% of the emulsion to be filled in center to center etc. complete as per the holes made in trenches at 150m.m IS:6313/1981(Part-II) complete including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P, sundries and scaffolding where required for the work etc. as directed by the Engineer -in -charge.
Filling in foundation trenches and plinth with excavated earth well watered and rammed in layers not exceeding 23 c.m in depth including all lead and lift, cost of all labour, sundries, T&P required for the work etc. complete in all respect as directed by the Engineer- in- charge.
Supplying & Filling foundation trenches , plinth & ditches with river sand well watered and rammed in layers not exceeding 23 c.m in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and taxes of all Materials, cost of all Labour,Sundries, T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge. (Measurement will be taken on finished compacted section only.)
Providing and Laying Plain Cement Concrete of proportion (1:3:6) in foundation and floors (i.e. below the base course of the flooring) using 40 mm size crusher broken H.G Stone Metal free from weathered skins , cement and screened & washed sharp river sand for mortar of approved quality & from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering & curing etc complete to required levels, laid in layers not exceeeding 15cm thick in each layer including cost, conveyance , loading,unloading, stacking ,royalties and taxes of all materials, cost of all labour, Sundries, T&P required for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of the water pump required for the work etc complete in all respect as directed by the Engineer-in-charge.
Providing Fly Ash Brick Masonry using bricks of size 25 c.m. x 12 c.m. x 8 c.m. having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in Foundation & Plinth of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
Providing Fly Ash Brick Masonry using bricks of size 25 c.m. x 12 c.m. x 8 c.m. having crushing strength not less than 75 kg per square c.m. in cement mortar of mix (1:6) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in the works in superstructure and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Terrace
Providing Fly Ash brick masonry using Fly Ash bricks of size 23 c.m. x 11 c.m. x 8 c.m.having crushing strength not less than 75 kg per square c.m in cement mortar of mix (1:4) (for half brick masonry wall) with provision of 2 nos of 6mm. dia M.S. Round Reinforcement bars at each 4th layers) with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth, basement and for ornamental flower beds, plinth moulding and similar such type of works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, loading, unloading, royalties and taxes of all materials ,cost of all labour, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Terrace
Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete of M-250 grade , as per approved designs and drawings having a minimum compressive strength ( in work test) 250Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips( of required quantities) from weathered skins of approved quality & from approved quarry, washed and cleaned to be mixed in concrete mixture with approved quality of cement including hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing the debrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, scaffolding, sundries, T&P
required for the work etc. complete in all respect but the excluding cost & conveyance of M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or Tor steel and binding wires and tying the grills and placing in proper position as directed by the Engineer-in-charge.
Foundation
Plinth beam
Column in Superstructure
Ground Floor
First Floor
Second Floor
Terrace Floor
LINTELS
Ground Floor
First Floor
Second Floor
CHAJJA AND SILL PROJECTION
Ground Floor
First Floor
Second Floor
FLOOR BEAM
Ground Floor
First Floor
Second floor
Terrace
STAIRCASES
Ground Floor
First Floor
Second Floor
ROOFSLAB
Ground Floor
First Floor
Second Floor
Terrace
Cutting, Straightening coiled or bent up HYSD / TMT Reinforcement Bars of Fe 500 welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing Fan Hooks where necessary and hoisting, lowering and placing the same in proper position according to the approved designs and drawings in all floors at all height including cost, coveyance, loading, unloading ,stacking & taxes of HYSD/ TMT Reinforcement Bars and Binding Wires of 18 to 20 Gauge as required for the work , cost of all Labour ,Sundries, T&P,Staging and Scaffolding complete in all respect as directed by Engineer-in-charge. (Payment will be made according to the actual / proper weight of the HYSD / TMT Reinforcement Bars & Binding Wires consumed in the particular work only) .
Ground Floor
First Floor
Second Floor
Terrace
16 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the rough surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. as directed by the Engineer- in -charge.
Ground Floor
First Floor
Second Floor
Terrace floor
12 m.m thick cement plaster in cement mortar of mix (1:6) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement, finished smooth to the even surface of the brick masonry walls after racking out the joints properly ,providing grooves wherever necessary including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, T&P, Sundries , Scaffolding, Watering, Curing,Rounding of corners etc. required for the work complete etc. as directed by the Engineer- in -charge.
Ground Floor
First Floor
Second Floor
Terrace floor
6 m.m thick cement plaster in cement mortar of mix (1:4) in all floors at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and taxes of all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge
Ground Floor
First Floor
Second Floor
Terrace Floor
12 m.m thick cement plaster with cement mortar of mix(1:4) in all floors using approved quality of cement , screened &washed sharp river sand for motar , with neat cement punning finished smooth to the brick walls in dados skirting after racking out the joints property including cost,conveyance,loading,unloading,stacking,royalties and taxes of all materials, cost of all labour,sundries T&P, scaffolding,watering,curing required for the work etc.complete in all respect as directed by the Engineer-in charge.
Ground Floor(Drain plaster)
25 m.m average thick artificial stone Flooring laid to proper slope with cement concrete of propertion (1:2:4) using approved quality of cement, screened &washed sharp river sand for motar with 12mm.to 20mm.size black hard crusher broken granite stone chips (20mm.size chips not to exceed 25%) of approved quality and from approved quarry, washed and cleaned, free from all debrises and slit, laid in two layers i.e. the bottom layer being 19mm.thick and top layer of 6mm. thick including chipping, chiselling, cleaning the top surface of the Roof slabs in upper floors, rounding of corners, watering and curing required for the work including cost, conveyance, loading,unloading,stacking,royalties and taxes of all materials,cost of all labour,sundries, T&P etc.complete in all respect as directed by the Engineer-in -charge.
Providing , Fitting & Fixing Ceramic Floor Tiles in flooring using special plain / printed series Anti-Skid Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 300 m.m x 300 m.m OR 400 m.m x400 m.m) confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry, joining the Anti-Skid Ceramic FloorTiles with neat white cement slurry,mixed with required (Tiles are to be immersed in the water for required time before use) quantities of pigments of approved marks to match the shades of the Anti-Skid Ceramic FloorTiles if required including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Supplying, Fitting & Fixing Ceramic Glazed Wall Tiles in Dados Skirting and Riser of Steps using approved shade,quality and size of Ceramic Glazed Wall Tiles (having thickness of 6.5 mm to 6.7 mm & 300 mm X450.mmsize) confirming to IS.13753 in proper position in all floors at all heights on 12 mm. thick cement plaster (1:3) using screened and washed sharp river sand for mortar with cement, grounted with neat cement slurry and jointed with neat cement mixed with required approved shade of pigment to match the shade of the Ceramic Glazed Wall Tiles (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading,stacking, royalties and taxes of all Materials, cost of all Labour, Curing, Sundries and T&P, etc. required for the work complete as directed by the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing minimum 20 m.m thick Granite Slab Flooring using approved quality, shade and size of Granite Slab above 0.40sqm specially in floors, treads on steps and landings in all floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Granite Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Granite Tile if required including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering,Curing for required days including rubbing mechanically and wax polishing etc. complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Supplying,Fitting & Fixing minimum 20mm.Thick Granite slab in Dadoos Skirting using approved shade,quality and size of Granite slab of 10mm.Thick above 0.40 sqm) in all floors at all heights on 12 m.m thick cement plaster (1:3) using screened & washed sharp river sand for mortar with cement, grouted with neat white cement slurry and jointed with neat white cement slurry mixed with required approved shade of pigment to match the shade of the Granite slab including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour,Watering, Curing,Sundries and T&P, etc. required for the work complete as directed by the of Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing edge moulding to 18 mm /20mm thick marble stone/Granite counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Ground Floor
First Floor
SecondFloor
Providing, Fitting and Fixing minimum 8 m.m to 10 m.m thick double charge Vitrified Tile in flooring using vitri Tile in flooring using vitrified Tile of approved quality, colour and size (600 mmx 600 mm coloured printed series homogeneous) in floors , treads on steps landings in all floors at all height on 25 m.m thick bed of cement mortar of mix(1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and grouted with neat white cement slurry joining the Vitrified Tile with neat white cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Vitrified Tile if required (Tile are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials , cost of all Labour , sundries, T&P required for the work, Watering, Curing for required days including cleaning the flooring space.
Ground Floor
First Floor
SecondFloor
Providing, Fitting & Fixing of 8 mm. to 10mm. thick Vitrified Tile (of size 600mm.x600mm.) of approved make confirming to specifications having minimum breaking strength 1400 kg/sq.cm in dados skirting and riser of steps in all floors at all height on 12m.m thick cement mortar (1:3) to proper slope , line and level including cutting to required size and shape ,fixing at corners and splays etc. including filling the joints with silicon sealant to match the shade of Vitrified Tile as per the design & drawing including cost, conveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing Chequered Tile Flooring using Chequered Tile (25mm thick) of approved quality, colour and size in floors at all height on 25 m.m thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened & washed sharp river sand for mortar ,grouted with neat cement slurry joining the Ultra Designer Tile with neat cement slurry mixed with required quantities of pigments of approved marks to match the shades of the Ultra Designer Tile if required (Tiles are to be immersed in the water for required time before use) including cost, conveyance, loading, unloading, stacking, royalties and taxes of all Materials, cost of all Labour, Sundries, T&P required for the work , Watering, Curing for required days, including rubbing and wax polishing etc. complete in all respect as directed by the Engineer-in-charge.
Ground Floor
Painting 2(two) or more coats with premium quality exterior emulsion paint(weather shield max ) of approved Brand/Quality & colour on the finished external plasterd surface using required quantities of paint by the concerned manufacturer to give an even shade over a coat of primer in all floors at all height, watering the surface before applying the Weather Coat paint and curing for the required period including cost , onveyance, loading , unloading , stacking, royalties and taxes of all materials, cost of all labour, T&P , sundries , watering & curing etc. required for the work complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Terrace Floor
Finishing surface of interior walls with premium quality interior acrrylic emulsion paint over a coat of wall priming of approved make and finished smooth & even surface with two coats of wall putty to receive painting in all floors at all height including cost, coveyance, loading , unloading ,stacking and taxes of all Materials, cost of all Labour, Sundries ,Scafffolding ,Staging and T&P etc. required for the work complete in all respect as directed by the Engineer-in-charge.
Ground Floor
First Floor
Terrace Floor
Terrace Floor
Providing and fixing factory made single extruded WPC wood polymer composite doors , windows and other frame with high dencity rigid solid wood polymer composite of 0.7DWPC foam sheet ,mitre cut at two corners abd joined and the two vertical door profile are to be reinforced to horizontal member .The door frame shall be fixed to the wall using 6nos 150mm long M.S holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer -in -charge.
Ground Floor size(125mmx65mm)
First Floor size(125mmx65mm)
Second Floor size(125mmx65mm)
Head room size(125mmx65mm)
Ground Floor size(75mmx50mm) in toilet
First Floor size(75mmx50mm)in toilet
Second Floor size(75mmx50mm)in toilet
Supply and fixing doors as per drawing with WPC solid 3layer and ISI marked door shutter of 30 mm thick single shutter with bond wood solid block board type of 0.7 D WPC sheet incluiding cost of convinience to site of WPC shutter incluiding supplying and fixing cost of ISI mark alluminium fixtures of 3 nos. butt hinges ( IS: 205) 150 mm long , one number of aldrop ( IS: 2681) 300 mm long, one number of tower bolt (IS: 204) of 200 mm x 10 mm dia at top , two numbers 150 mm long handles ( IS : 208) , one number door stoper and one number rubber / nylon door stop bushes incluiding fixing the fixtures to doors with required number of screws, bolt and nuts incluiding labour charges for fixing the frame in position, fixing the shutter to the frame etc. incluiding over head and contractor profit .
Ground Floor
First Floor
Second Floor
Head room
Supplying, Fitting and Fixing Stainless Steel 304 Grade of approved designs made out of Stainless steel bars etc. of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including required holes in Massonary Walls /R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Massonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.( Weight to be taken properly prior to fixing the grills in the works and payment to be made accordingly )
Ground Floor
First Floor
Second Floor
Providing, fitting, fixing UPVC windows( sliding type) including providing stainless steel hinges, locking arrangement and other requisite fittings and fixtures including cost, coveyance, loading, unloading and taxes of all materials,cost of all labour,scaffolding, staging, sundries and T&P required for the works etc. complete in all respect as per approved drawing,design & specification and as directed by the Engineer-in-charge all complete. (Fenest/ Wintek make).
Ground Floor
First Floor
Second Floor
Supplying , fitting and fixing of unplasticised poly vinyle chloride ( UPVC ) Doors and ventilator top hang 60 series duly manufactured using upvc reinforced profile of 60 mm x 55 mm x 2.5 mm outer frames, 75 mm x 60 mm x 2.25 mm for casement window sash profile capable of mounting single glazing system , structurally reinforced with hot dip galvanised upto 50 micrones of minimum thickness of 1.5 mm prefabricated and welded so through fusion welding the window sash shall be fitted with 6 mm thick clear toffen glass of saint Gobain make duly fixed with EPDM weathering seal resistance accessories like cliping locking system made of alluminium one number per set shases and the system is to be instalised at the site using anchoring fastner silicon rubber sealant, easy glazing/ deglazing at the site incluiding cost of convinience of all materials, accessories, labour charges , materials and product conferming to ASDM D 638-14, EN-477-95 and other applicable codes and standards.
Ground Floor
First Floor
Second Floor
Painting with synthetic enamel paint of approved colour, shade and brand like ICI/ Asian/ Berger on New wood work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.
Ground Floor
First Floor
Second Floor
Terrace Floor
Painting with synthetic enamel paint of approved colour, shade and brand like ICI/ Asian/ Berger on Steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.
Ground Floor
First Floor
Second Floor
Terrace Floor
Supplying, Fitting and Fixing of Stainless Steel of 304 grade in Handrail using 50mm dia of 2mm thick circular pipe with stainless steel balustrade of size 32 m.m x 32 m.m x 2 m.m @ 0.90mtr.centre to centre and stainless steel square pipe bracing of size 32m.m x 32m.m x 2m.m in 3 (Three) rows in stair case and at required places as per approved Drawings, Design and Specification,welding, buffing, polishing etc with cost, conveyance,loading,unloading ,stacking & taxes of all materials,cost of all labour, T&P etc. required for the work complete in all respect in all floors at all height as directed by the Engineer-in charge
Ground Floor
First Floor
Second Floor
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. (DSR 2014 Item No. 22.5 converted OSR-2014)
First Floor
Second Floor
Providing and filling AAC block inside the sunken floor with all cost, conveyance, taxes transportation loading, unloading etc complete as directed by the Engineer-in-Charge
First Floor
Secod Floor
25 mm. thick Grading Concrete of proportion (1:2:2) on top of the Roof Slab using approved quality of cement, 6 mm. size hard crusher broken granite stone chips with screened & washed sharp sand for mortar of approved quality from approved quarry, washed & cleaned, free from all debrises and silt along with providing a layer of waterproofing treatment by using pedicrete (URP/SBR) Latex before grading concret (Mix - Latex @ 0.54 Ltr/Sqm & Cement @ 0.008Qntl /Sqm) including hoisting, lowering and laying concrete in all floors at all height after chipping, chiseling and cleaning the entire roof surface by using wire brush, finished smooth to proper required slope and gradient including cost, conveyance, royalties, loading, unloading,stacking and taxes of all Materials, cost of all Labour, T &P, Sundries, Watering ,Curing etc.required for the work complete in all respect as directed by the Engineer-in-charge.(sika/pidilite/equivalent)
Second Floor&Top of head room
INTERNAL AND EXTERNAL PLUMBING WORKS
INTERNAL WATER SUPPLY WORKS
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer - in - Charge.
15mm dia.
20mm dia.
25mm dia.
32mm dia.
40mm dia.
50mm dia.
Cutting holes through existing brick work including making good the same in cement mortar (1:4) from taking GI / PVC pipes and fittings etc all complete as per specification.{with 1:4 brick work in cement mortar [Excluding contractors profit & Over head charges.] 10 x 0.12 x 0.25 and 12mm thick cement plaster (1:4) [Excluding CP & OHC] 10 x 0.12 x 0.25} For 250mm Thick Wall.
Brick Holes Cutting
Cutting hole in R.C.C floor and roofs upto 19 cm thick for passing G.I / P.V.C pipes and fittings etc and repairing the hole after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof. Details cost of 1 hole of average size 15cm x 15cm x 25cm
Rcc & Roofs Cutting
Cutting grooves in pucca floors and wall for taking GI / PVC pipes and making good the damages as per specification complete. With Cement concrete (1:3:6) with metal [Excluding CP & OHC] and 12mm cement plaster (1:3) [Excluding CP & OHC] along with Cement punning [Excluding Cp & OHC]
Cutting grooves in pucca floors
Fixing of Brass/GM Full Way Valve/ Ball Valve conforming to the following nominal sizes with wheel as per specification complete.
40mm dia.
50mm dia.
SOIL WASTE,RAIN WATER AND VENT PIPE.
Providing and fixing on floor unplasticised PVC sewer pipes conforming to IS:4985-2000 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion, (i) single socket pipes.
For 160mm diameter U-PVC SWR pipes.
200mm Dia Upvc
Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion, (i) single socket pipes.
For 110mm diameter U-PVC SWR pipes.
110mm Dia Upvc pipe
110mm Dia Upvc pipe with Encashing with c.c (1:3:6)
50mm dia waste pipe
Fixing floor traps of the following nominal diameter of outlet of self cleaning design with screwed down hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors all complete as per the specification
110mm INLET & OUTLET FLOOR TRAP
Providing and fixing on wall face PVC SWR moulded fittings/ accessories for unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type A, including Jointing with seal ring leaving 10mm gap for thermal expansion.
110MM DIA PLAIN BEND P.V.C SWR TYPE
110MM DIA BEND WITH DOOR P.V.C SWR TYPE
110MM DIA TEE W/O DOOR P.V.C SWR TYPE
110MM DIA CROSS TEE W/O DOOR P.V.C SWR TYPE
110MM DIA SINGLE "Y" P.V.C SWR TYPE
110MM DIA DOUBLE "Y" P.V.C SWR TYPE
110MM DIA COWEL AS PER P.V.C SWR TYPE
Fixing 110mm size 'P/S' trap (with horn or without horn) for water closet including jointing the trap with pan in cement mortar(1:1) as per specification.
110MM DIA P.V.C SWR P-TRAP
Providing and fixing square mouth S.W. Gully trap grade A complete with CI grating brick masonary chamber and water tight C.I cover with frame of 300 X 300 mm size (inside) the weight of the cover to be not less than 4.53 kg as per standard design. Cement concrete 1:2:4 around and 1:5:10 in base 125 X 100mm 'P,Q or S' type
GULLY TRAP S.W. TYPE
Construction of inspection chamber including excavation with clear opening of 400 X 400 and upto the depth of 450 mm in all type of soil with half brick masonary with well burnt chimney bricks crushing strength not less than 40kg/cm2 and water absorption not more than 20% and in C.M (1:4), 100 mm thick PCC of M15 in foundation. 12mm thick inside and outside plastering with CM(1:3), finished with PCC M15 flooring of 75mm thick as per drawings, including covering of chamber by supplying and fixing CI frame and cover as per IS covering by M15 grade concrete complete as per approved drawing, including fixing required number of uPVC pipe pieces and plugging the same etc.,complete as per drawing and/or directed by Engineer.
INSPECTION CHAMBER
Constructing manholes with R.C.C top slab in (1:1½:3) mix, foundation concrete (1:4:8), inside plaster 12mm thick with cement mortar (1:3) finished with neat cement punning, 12mm thick outside cement plaster (1:3), brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:5), cement concrete (1:2:4) finished smooth using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber with r.c.c precast cover complete as per specification.
MANHOLE
SANITARY FIXTURES & FITTINGS
Providing & Fixing Wash Down Water Closet (European type W.C pan) with integral 'P' trap conforming to JAQUAR MAKE of brand code CNS-WHT-751P180SPPZ and of viterous china make with Wall Hung Cistern, Drainage L Bend Pipe, Gasket and Installation Kit with PP normal close seat cover, hinges, Fixing Accessories all complete as per specification.
Water Closet (European type W.C pan)
Providing & Fixing Wash basin with hole for pillar tap conforming to IS : 2556 : Part 4-2004 / JAQUAR MAKE with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all compete as per specification. (Vitreous china flat back wash basin 560 x 415 x 200 mm (CODE CNS-WHT-801 JAQUAR MAKE)
Wash basin
Providing all materials, labour and T&P for fixing of C.P High Flow Diverter.
C.P High Flow Diverter.
Spout
Hand shower
Providing & Fixing of Screw-down ANGLE Stop Cocks conforming to CON-053KN (JAQUAR MAKE) of the following nominal sizes as per specification complete. (Deluxe Head & high quality),
(15mm diameter angle stop cock)
Providing & Fixing of Pillar Cock conforming to CON-CHR-011KN (JAQUAR MAKE) of the following nominal sizes as per specification complete. (Deluxe Head & high quality),
(15mm diameter pillar cock)
Providing & Fixing Chromium Plated Shower rose conforming OHS-1989 (JAQUAR MAKE) WITH SHA-477 SHOWER ARM INCLUDING polishing all complete as per specification . (Deluxe Head & Heavy quality)
Shower Head with Arm
Providing & Fixing Chromium Plated Liquid Soap Container complete with Chromium Plated brass brackets fixed to P.V.C plugs with Chromium Plated brass screws as per specification. (JAQUAR MAKE, BRAND ACN-1135N)
Liquid Soap Container
Liquid Soap Container
Providing & Fixing standard sized towel rail of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screw, complete as per specification. (Single towel rail 600mm long), (BRAND CODE ACN-1111SM), (Heavy Quality).
Towel Rail 600mm
Providing & Fixing standard sized towel ring of JAQUAR MAKE complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screw, complete as per specification. (Towel Ring Round with Round Flange), (BRAND CODE ACN-1121BN), (Heavy Quality).
Towel Ring
Providing & Fixing 630mmX445mm bevelled edge mirror (JAQUAR MAKE-AKP-35795) of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification.
Edge mirror
600mm Glass-shelf
Providing & Fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete as per specification
PVC waste pipe of 32mm
Providing & Fixing PVC inlet connection pipe of 15mm diameter and of nominal length for making connection with pillar cocks,cisterns and others with supply mains as per specification
PVC inlet connection pipe of 15mm
Providing & Fixing 32mm dia 80mm height CP brass waste coupling(JAQUAR MAKE Code - ALD-709) all complete as per specification
32mm waste coupling
Providing & Fixing 100m dia SS floor grating all complete as per specification
SS Floor Grating
Providing & Fixing 15mm dia CP two way bib cock conforming to JAQUAR MAKE of brand code Jaquar KUP 35041PM , Fixing Accessories all complete as per specification
Two way bib cock
Providing & Fixing 15mm dia health faucet(Jaquar) conforming to JAQUAR MAKE all compete as per specification.
Health faucet
Supplying all materials, labour, T&P and fixing SS Sink without Drain board Nirali Elegance Ultra or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
SS kitchen Sink
Supplying all materials, labour, T&P and fixing standard size Sink cock of Jaquar Cat. No.-CON 347KNM or equivalent type of approved make etc complete including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge.
Sink Cock
Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks of 2000 Ltr capacity each conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge
2000 Ltr capacity Tank
Roof Top Tank Pedestal for 2000ltr. Capacity four nos
Sinking of 200mm x 150mm Dia Production Well drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of Engineer-in-charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of 200 mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/PVC casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tube well).
Sinking of 200mm x 150mm Dia Production Well
1.50 dia x 3.0 m deep soakway pit
Supplying all material, labour, T&P and construction 50 users Spetic tank with Two years cleaning interval of iner size 7.7 x 2.4 x 1.7 (liquid depth) as per the approved drawing and specifications with over a bed of 100mm thick P.C.C (1:4:8) 150mm thick P.C.C (1:2:4) & 40 mm thick ( Avg.) A.S flooring inside wall plastering with 12mm thick C.P in C.M (1:4) including neat cement punning, outside wall plastering with 16mm thick C.P in C.M (1:4), RCC down graded chips with necessary reinforcement, centering and shuttering including 02 nos of SFRC manhole cover with frame of approved quality with inlet & out let chamber of size 750 x 750 x 450mm, one partition wall & two buffle walls, supply,fitting and fixing of necessary specials & fitting Tee, vent pipe ,pvc footrest including excavation of earth in all kind of soilincluding bailing out water and shoring, shuttering etc. as necessary and back filling the sides of tank and filling up the chamber with after.
INTERNAL WIRING INCLUDING SUPPLY OF ALL REQUIRED MATERIALS.
Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Each lightpoint should have provision for ceiling rose and angle holder point. In all the rooms there shall be two types of switchboard- one for raw and the other one for inverter. The inverter switchboard shall include atleast one fan, one light and other emergency sockets. Each quarter shall have 2 separte Dbs- one for raw and the other one for inverter.
GROUP-A
GROUP-B
GROUP-C
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius ) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)(( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.Make Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 2 x 6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type) ( ( flame retradant type) with suitable size modular box & metallic cover plate (both side)( flame retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius )/Panasonic (vision)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (2X1.5+1X1.5)
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit. (2X2.5+1X1.5)
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit (2X4+1X1.5)
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit . (2X6+1X2.5)
Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
Sub-Head II (Light fitting Fixture & Fan)
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.( REGULATOR COMPATIBLE)
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
SITC of Sleek LED 9 watt LED Lamp complete with all accessories etc. directly on angle holder as required AS PER DIRECTION OF eNGINEER-IN-CHARGE. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supply and fixing of 10 Watt LED BH Fitting (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
BDBS,DB,AC DB,FLOOR PANELS,MCBS
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years
Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
Supply and fixing of 8 way(Inverter DB) DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ABB SB 200 the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 years.
Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, DP MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 year.
Supplying and fixing 32Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9./ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
Supplying and fixing 32 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, DP MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ ABB FB200 in the existing DB complete with connections as required as per direction of Engg.-in-Charge. . The MCB should be Replacement Warranty will be 1 year.
(Earthing) INSTALLATION
S/IT/C Of Earthing withG.I earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.
Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
CABLING AND END TERMINATION MAIN AREA
Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
3.5core x 95 sq mm
LAYING OF CABLE
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Supplying and making end termination with brass comprecision gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
3.5 core x95 sq mm
PANELS
MAIN METERING PANEL
S/I/T&Commissioning of CPRI tested LT indoor floor mounted double door with provision of padlock Metering main cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.20X10MM Separate Aluminium Earth bus bar should be installed.. 1 nos of 3P+N Type 1+2 SPD65kA with 63A 4P MCB,10kA, Cseries(Make-LEGRAND/ Siemens/ Schneider shall be installed in the incomer.OFF/ON/TRIP indication for all the feeders.
In commer - 160A 4P Icu=100%Ics,25Ka MCCB with TMR based release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula & 1 no of 125A 4P ON Load changeover switch( ( Make-LEGRAND / Siemens-Model/ Schneider/ABB )
Busbar-1&2 04 numbers of 250Amps al busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
Out going- (i) 63A 2P MCB rating,10 KA breaking capacity,C series, MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) 11nos with space for 11 nos 10-60A 1PH KWH Meter digital type for each quarter .
Out going- (ii) 25A 2P MCB rating,10 KA breaking capacity,C series, MCB (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200) 2 nos with space for 2 no 10-40A 1PH KWH Meter digital type for common area.
Instrument- (i) phase indicating lamp with toggle switch & HRC fuse for all incomers
(ii) Digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication for all incomers..
LIGHTENING PROTECTION SYSTEM
Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/ABB/Equivalent
Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/ABB/Equivalent
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
EXTINGUISHER SYSTEM
Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories Make-Ceasefire/Safex/Fireshield
Supply of 3 nos un Skilled labour for watch and ward during the execution work period.
stage.html
html • 0.06 MB
technical_573205.pdf
techsummary_573205.pdf
finance_573205.pdf
BOQ Comparative Chart
xlsx
finsummary_573205.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.20 MB
dtcndmer.pdf
Tender Documents • 15.93 MB
BOQ_573205.xls
BOQ • 1.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .