Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-Finance | L1 | Accepted-Finance In order and L1 | |
| 2 | L2₹26.1 L+₹9,605 (0.37%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹29.5 L+₹3.5 L (13.3%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L3 | Rejected-Finance In order but L3 | |
| 4 | Progressive Builders L4₹32.0 L+₹6.0 L (22.9%)Rejected-Finance | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹33.7 L+₹7.7 L (29.6%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
31 Jan 2024, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee Road Meerut Cantt
CLEANING, PAINTING AND MARKING AND ITS ALLIED ITEMS OF OVERHEAD RESERVOIR AT VARIOUS PUMP HOUSES OF NORTH AREA OF AGE E/M (WS) UNDER GE (U) MEERUT CANTT
2024_MES_635520_1
8569/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (U) Meerut Cantt
₹86,000
Yes
10 May 2024
3 Jan 2024
3 Feb 2024
3 Jan 2024
31 Jan 2024
17 Jan 2024
Amount
M&L for seven stage cleaning and sterilization inside the existing RCC overhead tank of capacity up to 200000 gallon through bacteriological and fungal treatment by using sodium hypochlorite, potassium permanganate /E-in-C's Branch approved chemical as recommended by Engr-in-Charge and ULTRA VOILET RAY at Pump house at any height (as per site requirement), including suitable staging/scaffolding seven stage are as under follows:- (a) First stage is to drain out the water by using high capacity pump of dewatering system. (b) Second stage is cleaning all the stage formation inside the tank by using sodium hypochlorite a laboratory tested branded chemical/ E-in-C's Branch approved chemical as recommeded by Engr-in-Charge. (c) Third stage is scrubbing the walls and floor with mechanised scrubber and fresh water cleaning high speed jet pump (Rotary & flat) to remove all scalling algae and other formed particlaes on internal surfaces of the tank completely. (d) Fourth stage and first fungal screening is sterilization by using potassium permangate, Laboratory certified and tested chemical E-in-C's Branch approved chemical as recommended by Engr -in-Charge, test certificate from government laboratory monitoring suitability for sterilization should be submitted to the office before using stralisation. (e) Fifth stage is cleaning the floor of water tank by heavy duty industrial vaccume cleaners and sludge succor having maximum 1200 watt with suitable heavy duty rugged motor to free any foreign and loose particales of any nature (f) Sixth stage is providing UV radition which shall have 360 degree off sterilization with in the tank to kill all suspended bacteria (The radition shall portable and effective for sterilization of drinking water tanks for diminetion of floeting and suspended bacteria.) (g) Seventh stage of cleaning is to sterlizes the floor of the water tank by using branded strong oxidizing agent non toxic bio-degredable eco-friendly anti-bacterial agent (high potency sodium hypochlorite) certified by a Govt. approved laboratory to disinfect the over head tank from all harmful pathogens. (h) Cleaning of, lid wall of the tank, structure for all scales and other particles any algae, hives and any type of vegetation of any other unwanted matters.
(j) A sticker of appropriate size and colour as directed by Engr-in-Charge and of non degradable material with printed details as under :- Tank capacity, date of cleaning and expiry date will be written or printed on the sticker by permanent marking ink. (K) The wire mess of ventilaters of the tank shall be replaced with new GI wire mesh. (L) Testing of water sample of each OHT before and after cleaning shall be carried out of following tests: (i) Chemical and Physical : - Colour, odour, taste, turbodity, PH, total hardness, iron, chloride, free residue chlorine, fluoride, total dissolve solid, calcium, magnesium (ii) Biological testing:- E- coli, Coliform as per IS from any govt NABL approved laboratories and submission of test report complete all as specified and directed by Engr-in- Charge. Note:-(i) Collection of Sample of water shall be done by the authrozied rep of the approved laboratry from whom the testing of water is to be carried out (ii) All required safety equipemnts (Gumboot, helmets, safety belts, safety foogles, torch light etc) and necessary insurance for safety of working staff to execute the work is resposibility of the contractor. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/disel shall not be provided by the MES. (iv) Contractor will not be allowed more than one day to do the work inside of the each OH tank /UG sump to prevent interruption of water supply to the users.
All as per item No 01 above here in before but the capacity of the tank is 25000 gallon
All as per item No 01 above here in before but the capacity of the tank is 50000 gallon
All as per item No 01 above here in before but the capacity of the tank is 100000 gallon
All as per item No 01 above here in before but the capacity of the tank is 200000 gallon
Sampling of chlorinated water from various pump houses under AOR of AGE E/M W/S Meerut as and when required and carry out the following tests :- (i) Chemical and Physical : - Colour, odour, taste, turbodity, PH, total hardness, iron, chloride, free residue chlorine, fluoride, total dissolve solid, calcium, magnesium (ii) Biological testing:- E- coli, Coliform as per IS from any govt NABL approved laboratories and submission of test report complete all as specified and directed by Engr-in- Charge. Note:- Collection of Sample of chlorinated water shall be done by the authrozied rep of the approved laboratry from whom the testing of water is to be carried out.
Sampling of non chlorinated water from various pump house under AOR of AGE E/M W/S Meerut as and when required and carry out the following tests :- (i) Chemical and Physical : - Colour, odour, taste, turbodity, PH, total hardness, iron, chloride, free residue chlorine, fluoride, total dissolve solid, calcium, magnesium (ii) Biological testing:- E- coli, Coliform as per IS from any govt NABL approved laboratories and submission of test report complete all as specified and directed by Engr-in- Charge. Note:- Collection of Sample of non chlorinated water shall be done by the authrozied rep of the approved laboratry from whom the testing of water is to be carried out.
M&L for painting to existing MS structure at pump houses with two coat synthetic enamel paint after prepration the steel surfaces by srubbing the old paint with brush and cleaning the oil surface clearely of any description over 10cm in width or girth , not otherwise described complete as specified and directed .
Taking down copper / aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets light fitting etc removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per condition seprately) and making good disturbed surfaced of wall , floors etc complete all as specified and as directed by Engr-in-Charge.
M&L Point wiring surface type with 1.5 sqmm (nominal area) PVC insulated stranded single core unsheathed FRLS copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 1.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FR copper cable as earth continuity wire connecting to common earth point with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting switches, sockets, regulatros etc complete) for One light point or one fan point or exhaust fan controlled by one switch complete all as specified and as directed
-do- all as per item No- 06 here in above but for one 3 pin socket outlet, 6 Amp on the same board with other switch complete all as specified and directed.
-do- all as per item No- 06 here in above but for one 3 pin socket outlet, 6 Amp on the independent board with other switch complete all as specified and directed.
- do - all as per item no - 06 here in above but using 2.5 sqmm (Nominal Area) for 5 pin, 16 Amp on independent board complete all as specified and as directed.
S&F in repair stepped type fan regulator for ceiling fan of sweep 1200/1400 mm stepped type 230 volts, 100 watt flush mounted complete all as specified and as directed.
S&F in repair switch piano, flush type 5 amps, 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 5 pin 5 Amps flush type conforming to IS complete all as specified and as directed.
S&F in repair switch piano, flush type 15 amps, 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
S&F in repair socket outlet 2 in 1, 6 pin, 15 Amp flush type 240 volts, single pole, one way, conforming to IS complete all as specified and as directed.
Supply and fixing in repairs surface and wall mounted LED batten, 1 X 20 Watt in extruded aluminium housing, with polycarbonate diffuser & integrated electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper conductor cable of suitable size incl taking down existing fitting complete all as specified and directed.
Supply and fixing in repairs energy saving & Enviroment friendly LED bldg security light fittings single phase 220 volt with pressure die cast anodized alluminium housing having capacity 35 watt including bracket fitting made out of GI pipe 32mm dia bend to required shape fixing on wall with two nos of MS clamps , nuts and bolts of suitable size including connecting up electrically complete all as directed by Engr - in - Charge.
Taking down and supply and fixing of flex board of size 3 ft X 4 ft with heavy duty PVC hard good quality border of size 40mm width including writting the details of pump set like Type, capacity of pump , Make, SL No, Date of installation, SM No , same for Motor like Type, Capacity, Make, SL No. OH Reservoir tank capacity and water supplied area etc all as specified by Enginner in Charge
M&L for earth required to be brought from outside defence land including spreding and levelling in layers not exc 25 cm thick and add for well ramming including watering and consolidation complete all as specified and directd by engr-in- charge.
Supply and fix in repair MCB , single pole 6 to 32 Amps 230 volt 10 KA complete all as specified and directed .
Supply and fix in repair MCB , single pole and neutral 6 to 32 Amps 230 volt 10 KA complete all as specified and directed .
Taking out old unserviceable submersible pump set and Supply ,install, testing and commissioning submersible pump set against recommended BER of capacity 30 HP,and discharge 1200 LPM at 70 Mtr Head electric driven 415 V, TP suitable for 150 mm dia bore well (Casing pipe size 250/300mm) including removal of old pump to MES Store yard, complete all as specified and directed.
Taking out old unserviceable submersible pump set and Supply ,install, testing and commissioning submersible pump set against recommended BER of capacity 20 HP and discharge 800 LPM at 70 Mtr Head electric driven 415 V, TP suitable for 150 mm dia bore well (Casing pipe size 250/300mm) including removal of old pump to MES Store yard, complete all as specified and directed.
Electrically disconnecting of defective Voltage stablizer of capacity 30 KVA to 200 KVA three phase 415 Volt of any make disconnect incoming and out going cables, carrying to auth work shop for carrying out the repair, replacing by of old unsv part like gasket set, nuts, bolts, washers oil, including rewinding of Voltage stablizer with supper enamel copper wire of exiting gauge complete with insulating material ,varnishing , heating and brining back to site, re-installing, connecting and testing on full load complete after repair all as specified and directed by Engr-in-Charge. Note:- (a) Spare parts shall be measured and paid for separately as supply only. (b) Rate shall be deemed to inclusive for transportation incl loading/unloading charges.
Supply only supper enamel copper wire for rewinding of voltage stablizer under item No-23 of suitable gauge ,1100 Volt grade complete all as specified and directed at site.
Taking out old unserviceable cable,Supply and laying XLPE cable PVC Insulated, screened PVC bedded galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 volts grade with standard aluminium conductor of size 95 Sqmm 3.5 core , laid in trenches/ducts or passed through pipes/roads or fixed to walls/poles complete all as specified and directed.
Taking out old unserviceable cable, Supply and laying XLPE cable PVC Insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 volts grade with standard aluminium conductor of size 70 Sq mm 3.5 core , laid in trenches/ducts or passed through pipes/roads or fixed to walls/poles complete all as specified and directed.
Taking out old unserviceable cable, Supply and laying XLPE cable PVC Insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 volts grade with standard aluminium conductor of size 50 Sq mm 3.5 core , laid in trenches/ducts or passed through pipes/roads or fixed to walls/poles complete all as specified and directed.
Dehydration of Voltage stablizer oil including filtration and cleaning of Voltage stablizer oil at site by dehydration machine including testing of sample before and after dehydration including testing of stabilizers complete all as specified and directed
Supply only transformer oil for topping up in Voltage stablizer as per IS-335/93 die electric strength not less than 40 KV including testing after topping complete all as specified and directed at site.
Material and labour for painting to Voltage stablizer after preparation of old painted surface of steel or iron surface by brushing cleaning staining grease/oil spot with thinner and applying two coats of synthetic enamel paint by spray gun machine to external surface of stabilizers of sizes 30 KVA to 75 KVA 3 phase 440 Volt complete with writting the SM No all as directed
Material and labour for painting to VT motor after preparation of old painted surface of steel or iron surface by brushing cleaning staining grease/oil spot with thinner and applying two coats of synthetic enamel paint by spray gun machine to external surface of VT motor of capacity 25 HP to 75 HP, 3 phase 440 Volt complete with writting the SM No all as directed
Supply only rotary mechanism of dimmer through armature motor of Voltage stablizer capacities 30 KVA to 75 KVA complete all as specified and directed .
Supply only rotary switch for voltmeter RY-YB-BR Make - AE/L&T/Havells
Supply & fixing in repair terminal plate hard bakelite insulating with copper terminal for cable connection of three phase and neutral , 1100 Volt suitable 75 HP motor complete all as directed at site.
S & F in repair butter fly valve with handle conforming to IS-14846-2000 both end flange including suitable size of nuts, bolts with washer and rubber gasket of valve size 200 mm bore including taking out old unserviceable complete all as specified and directed.
S & F in repair butter fly valve with handle conforming to IS-14846-2000 both end flange including suitable size of nuts, bolts with washer and rubber gasket of valve size 150 mm bore including taking out old unserviceable complete all as specified and directed.
S & F in repair butter fly valve with handle conforming to IS-14846-2000 both end flange including suitable size of nuts, bolts with washer and rubber gasket of valve size 100 mm bore including taking out old unserviceable complete all as specified and directed.
M&L for repair / replacement of steel ladder at over head water tank by febricated from steel structure bracings , supports including nut bolt washer , welding , bending cold or hot drilling holes for bolt , in any shape or size as directed at site complete.
S & Fixing in repair long length cast iron detachable joint size not less than 200mm long complete with nut , bolt , washer and eubber ring set suitable for CI pipe of size 200 mm dia.
S & Fixing in repair long length cast iron detachable joint size not less than 200mm long complete with nut , bolt , washer and eubber ring set suitable for CI pipe of size 150 mm dia.
S & Fixing in repair long length cast iron detachable joint size not less than 200mm long complete with nut , bolt , washer and eubber ring set suitable for CI pipe of size 100 mm dia.
S&F in repairs mild steel plain black sheet to cover the over head tank main entrance and roof of pump house for lifting purpose of chain pully of suitable size and thick ness not than 5.0 mm thick complete with welding / bending to requird size complete with one coat of red oxide primer and two coat of black enamel paint all as specified and directed at site.
Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed
Disconnecting and Taking out old existing CI pipe including all fitting with spigot and socket ends and lead jointed any description / grade and in any position of trenches / under floors/ on wall etc all as directed of size 200mm bore.
M & L in repair Ductile iron pipes 200mm dia bore with spigot and socket ends, centrifugally cast (spun) class K9, in any length, externally coated with metallic Zinc Coating finished with bituminous paint complete all as specified of the following bore:- Note :- Excavation, earthwork and GI clamps shall be measured and paid separately)
CHAUDHARY FURNITURE HOUSE
SIYA ASSOCIATES
Progressive Builders
VIRAT CONSTRUCTIONS
Shikha Enterprises
M/S JPS Electrical Engineer & Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .