SE EWC Gorakhpur
Srirampuram Colony Mohaddipur Gorakhpur
Increasing Capacity of Gauribazar, khukhundu, Majhaulira, Ramilila Maidan Deoria
2024_PVVNV_920951_1
58/EWC(G)/2023-24
Open Tender
Electrical Works
Item Wise
30 days
Deoria
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE EWC Gorakhpur
₹40,000
Yes
28 May 2024
1 Apr 2024
15 Apr 2024
1 Apr 2024
12 Apr 2024
1 Apr 2024
Amount
Shifting & loading of following materials on private truck at store centre Deoria & carriage up to 33/11 KV Sub-Station Gauribazar Distt-Deoria & Un-loading of the same with proper stacking (Distance about 0 to 18 km)
11 KV ‘XLPE’ Power cable.
33 KV ‘VCB’ complete with all structure
33 KV. C.T. with structure
33 KV Control panel for Single Transformer
33 KV Bus Isolator 400 Amp.
33 KV Post Insulator with structure
Repairing of plinth and foundation for 10 MVA transformer as per required specification. Dismantling of T/F all connection, Rail pieces and T/F shifting to another place by crane.
Providing & Making connection of Battery charger with 24 (12+12 volt) Volt battery ( Exide tubuler battery) with cabinet.(1 Set=2 No. Battery 12 Volt and 01 No. charger)
Dismantling of H.T. jumpers, 11 KV C/J kits & different earthings of existing 5 MVA T/F. Drain out of T/F oil After closing valves and opening of radiators for shifting of existing 5 MVA T/F from plinth by Crane about 30 mtrs distance & resetting of accessories etc. complete work
Providing & Making connection 33 KV PG clamp for jumpering of Busbar connection
Digging of pits for taking out of old, used and damaged 11 KV cable & making ring safely.
Providing & Making connection of Alluminium. Lug 3x300 mm2 for jumpering of 10 MVA T/F and Busbar connection
Dismantling of Bus bar Jumpers, different earthings of existing 5 MVA T/F. etc. complete work
Transformer body earthing at two places including cost of G.I. strip, G.I. pipe and other earthing materials required.(delta type)
Laying of 11 KV “XLPE” cable 3 x 300 mm2 including digging of pits of size 0.5 x 0.5 mtr. covering of cable with sand and 1st class bricks around and top of the cable.
Providing of 33 KV. Top channel for cable stand & neutral earthing
Neutral earthing of 10 MVA transformer complete including cost of G.I. strip, G.I. pipe 1.5” dia 30’ long and other earthing materials.(delta type)
Grouting of M.S. Channel 3.2 mtr. long for neutral earthing support of 10 MVA transformer with help of G.I. strip 50 x 6 mm and copper flexible bond etc.
Grouting of M.S. channel 3.2 mtr long for cable stand and welding of M.S. flat at equal distance for fastening cable by clamp with nuts and bolts mounting of cable at cable stand and connection of jumpers.
Providing & Jointing charges of 11 KV “XLPE” C/J kit 3 x 300 mm2 indoor/outdoor.
Dismantling of existing pale fencing and resetting after completion of trnasformer work.
Erection and grouting of “VCB” Structure, mounting and fitting of “VCB” on erected structure, earthing, wiring etc complete work.
Erection and grounting of CT structure, mounting and fitting of “CT” on erected structure, earthing, wiring etc complete work.
Carriage of old and Used 11 KV Cable From 33/11 KV Sub Station -Gauribazar to Store center deoria .
Installation of 33 KV control panel, wiring with complete earthing and respectively installation of battery and battery charger in control room and making connection.
Erection, grouting and earthing of following structure
33 KV Post Insulator Structure
Mounting and fitting of equipment on erected structures.
33 KV Bus – Isolator 400 Amp
33 KV Post Insulator
Providing following control cable and its laying form switchyard to control room 33 KV panel by digging trench in switchyard including cost of sand and 1st class bricks with covering and making connection complete and including cost of laying.
Painting of structure in switchyard.
Shifting & loading of following materials on private truck at store centre Deoria & carriage up to 33/11 KV Sub-Station Khukhundu Distt-Deoria & Un-loading of the same with proper stacking
33 KV ‘VCB’ complete with all structure
33 KV. C.T. with structure
33 KV Control panel for Single Transformer
33 KV Bus Isolator 400 Amp.
33 KV Post Insulator
Repairing of plinth and foundation for 10 MVA transformer as per required specification. Dismantling of T/F all connection, Rail pieces and T/F shifting to another place by crane.
Providing & Making connection of Battery charger with 24 (12+12 volt) Volt battery ( Exide tubuler battery) with cabinet.(1 Set=2 No. Battery 12 Volt and 01 No. charger)
Dismantling of H.T. jumpers, 11 KV C/J kits & different earthings of existing 5 MVA T/F. Drain out of T/F oil After closing valves and opening of radiators for shifting of existing 5 MVA T/F from plinth by Crane about 30 mtrs distance & resetting of accessories etc. complete work
Providing & Making connection 33 KV PG clamp for jumpering of Busbar connection
Providing & Making connection of Alluminium. Lug 3x300 mm2 for jumpering of 10 MVA T/F and Busbar connection
Dismantling of Bus bar Jumpers, different earthings of existing 5 MVA T/F. etc. complete work
Transformer body earthing at two places including cost of G.I. strip, G.I. pipe and other earthing materials required.(delta type)
Providing of 33 KV. Top channel for cable stand & neutral earthing
Neutral earthing of 10 MVA transformer complete including cost of G.I. strip, G.I. pipe 1.5” dia 30’ long and other earthing materials.(delta type)
Grouting of M.S. Channel 3.2 mtr. long for neutral earthing support of 10 MVA transformer with help of G.I. strip 50 x 6 mm and copper flexible bond etc.
Grouting of M.S. channel 3.2 mtr long for cable stand and welding of M.S. flat at equal distance for fastening cable by clamp with nuts and bolts mounting of cable at cable stand and connection of jumpers.
Erection and grouting of “VCB” Structure, mounting and fitting of “VCB” on erected structure, earthing, wiring etc complete work.
Erection and grounting of CT structure, mounting and fitting of “CT” on erected structure, earthing, wiring etc complete work.
Installation of 33 KV control panel, wiring with complete earthing and respectively installation of battery and battery charger in control room and making connection.
Mounting and fitting of equipment on erected structures.
33 KV Bus – Isolator 400 Amp
33 KV Post Insulator
Providing following control cable and its laying form switchyard to control room 33 KV panel by digging trench in switchyard including cost of sand and 1st class bricks with covering and making connection complete and including cost of laying.
Painting of structure in switchyard.
Shifting & loading of following materials on private truck at store centre Deoria & carriage up to 33/11 KV Sub-Station Majhauliraj Distt-Deoria & Un-loading of the same with proper stacking.
11 KV ‘XLPE’ Power cable.
33 KV ‘VCB’ complete with all structure
33 KV Control panel for Single Transformer
33 KV Bus Isolator 400 Amp.
33 KV Post Insulator with structure
Repairing of plinth and foundation for 10 MVA transformer as per required specification. Dismantling of T/F all connection, Rail pieces and T/F shifting to another place by crane.
Providing & Making connection of Battery charger with 24 (12+12 volt) Volt battery ( Exide tubuler battery) with cabinet.(1 Set=2 No. Battery 12 Volt and 01 No. charger)
Dismantling of H.T. jumpers, 11 KV C/J kits & different earthings of existing 5 MVA T/F. Drain out of T/F oil After closing valves and opening of radiators for shifting of existing 5 MVA T/F from plinth by Crane about 30 mtrs distance & resetting of accessories etc. complete work
Providing & Making connection 33 KV PG clamp for jumpering of Busbar connection
Digging of pits for taking out of old, used and damaged 11 KV cable & making ring safely.
Providing & Making connection of Alluminium. Lug 3x300 mm2 for jumpering of 10 MVA T/F and Busbar connection
Dismantling of Bus bar Jumpers, different earthings of existing 5 MVA T/F. etc. complete work
Transformer body earthing at two places including cost of G.I. strip, G.I. pipe and other earthing materials required.(delta type)
Laying of 11 KV “XLPE” cable 3 x 300 mm2 including digging of pits of size 0.5 x 0.5 mtr. covering of cable with sand and 1st class bricks around and top of the cable.
Providing of 33 KV. Top channel for cable stand & neutral earthing
Neutral earthing of 10 MVA transformer complete including cost of G.I. strip, G.I. pipe 1.5” dia 30’ long and other earthing materials.(delta type)
Grouting of M.S. Channel 3.2 mtr. long for neutral earthing support of 10 MVA transformer with help of G.I. strip 50 x 6 mm and copper flexible bond etc.
Grouting of M.S. channel 3.2 mtr long for cable stand and welding of M.S. flat at equal distance for fastening cable by clamp with nuts and bolts mounting of cable at cable stand and connection of jumpers.
Providing & Jointing charges of 11 KV “XLPE” C/J kit 3 x 300 mm2 indoor/outdoor.
Erection and grouting of “VCB” Structure, mounting and fitting of “VCB” on erected structure, earthing, wiring etc complete work.
Erection and grounting of CT structure, mounting and fitting of “CT” on erected structure, earthing, wiring etc complete work.
Installation of 33 KV control panel, wiring with complete earthing and respectively installation of battery and battery charger in control room and making connection.
Erection, grouting and earthing of following structure
33 KV Post Insulator Structure
Mounting and fitting of equipment on erected structures.
33 KV Bus – Isolator 400 Amp
33 KV Post Insulator
Providing following control cable and its laying form switchyard to control room 33 KV panel by digging trench in switchyard including cost of sand and 1st class bricks with covering and making connection complete and including cost of laying.
Painting of structure in switchyard.
Increasing Capacity of (2x10 to 2x10+5 MVA) 33/11 S/s Ramlila Maidan, Deoria PART - A (Decentralized Materials Provided by Contractor)
11 KV T-off Channel
T-off Channel holding clamp with Bolts and Nuts
‘F’ Bracket with Bolts and Nuts
11 KV. polymer Disc Insulator T&C Type
11 KV. Disc fitting T&C Type
11 KV.composite polymer Pin Insulator
Stay Complete ( stay Rod 16x1800 mm, stay wire 5 Kg, stay clamp with nut and bolt with grouting.
Number Plate with clamp and Nut & Bolt
Danger Board with Clamp
G.I. Barbed Wire
Bolts, Nuts, & Washers all Sizes
Alluminium Paint
Red Oxide Paint
M.S. earthing complete
Armoud Cu. Control cable 2 x 2.5 mm2
Armoud Cu. Control cable 4 x 2.5 mm2
TG for extension of Bus -Bar
11 KV “XLPE” C/J kit 3 x 300 mm2 indoor
11 KV “XLPE” C/J kit 3 x 300 mm2 outdoor.
11 KV “XLPE” C/J kit 3 x 185 mm2 indoor
11 KV “XLPE” C/J kit 3 x 185mm2 outdoor.
PART - B (WORK) Shifting & loading of following materials on private truck at store centre. Deoria & carriage up to 33/11 KV Sub-Station - Ramlila Maidan Distt. Deoria & Un-loading of the same with proper stacking.
11 KV Cable 300mm² XLPE/3x185mm²
33 KV ‘VCB’ complete with all structure.
33 Bus Type Isolator
33 KV control Pannel
33 KV lightening arrester
33 KV Small structure( Bus isolater structure,post insulator structure, fuse set structure.CT Structure, LA Structure, PT Structure)
33 KV Post insulator
11 KV Switchgear panels
S.T. Pole – 11 Mtr. Long
Construction of power transformer plinth for 5 MVA transformer of size 3.5 x 3.5 x 1.5 mtr. including cost of all material as per drawing.
Installation of New 5 MVA T/F about 35 mtrs distance & placing on T/F plinth.Erection of conservator tank, radiators & filling of T/F oil, jumpering etc. complete work.
Earthing of 5 MVA power transformer body earthing at two places including cost of G.I. strip, G.I. pipe and other earthing materials required.(delta type earthing)
Providing & Making connection of Battery charger with 24 (12+12 volt) Volt battery ( Exide tubuler battery) with cabinet.(1 Set=2 No. Battery 12 Volt and 01 No. charger)
Providing & Making connection 33 KV PG clamp for jumpering of Busbar connection
Providing & Making connection of Alluminium. Lug 3x300 mm2 for jumpering of 10 MVA T/F and Busbar connection
Providing of 33 KV. Top channel for cable stand & neutral earthing
Neutral earthing of 10 MVA transformer complete including cost of G.I. strip, G.I. pipe 1.5” dia 30’ long and other earthing materials.(delta type)
Grouting of M.S. Channel 3.2 mtr. long for neutral earthing support of 10 MVA transformer with help of G.I. strip 50 x 6 mm and copper flexible bond etc.
Grouting of M.S. channel 3.2 mtr long for cable stand and welding of M.S. flat at equal distance for fastening cable by clamp with nuts and bolts mounting of cable at cable stand and connection of jumpers.
Providing & Jointing charges of 11 KV “XLPE” C/J kit 3 x 300 mm2 indoor/outdoor.
Providing & Jointing charges of 11 KV “XLPE” C/J kit 3 x 185 mm2 indoor/outdoor.
Erection of Single pole structure on 11mtr ST. (SP-55) Pole including all works of evocation of pit, pole erection, making plinth for poles 30 cm above , grouting in the ratio 1:4:8 (cement, sand, 40mm brick ballast),back filling of earth ,proper ramming & fitting of all accessories for double circuit ( 'M.S. T- off Channel with clamps & bolt and nut, composite polymer Disc insulator, composite polymer pin insulator, danger board with clamp, Alluminium paint, red. oxide paint, barbed wire earthing, etc. complete). for 11 KV Cable hanging
Installation of 33 KV control panel for “VCB” with complete earthing with installation of battery and battery charger in control room and making connection.
Laying of 11 KV “XLPE” power cable 3 x 300 mm2 / 185 mm2 mm2 including digging of pits of xize 0.5 x 0.5 mtr. covering of cable with sand and 1st class brick around the cable.
Shifting of 11 KV switchgear to control room and placing in control room with grouting of bolts and mounting of switchgear panels properly.
Erection and grouting of “VCB” Structure, mounting and fitting of “VCB” on erected structure, earthing, wiring etc complete work.
Electrical connection of 11 KV switchgear panel and fitting of Bus Bar and P.T.
Testing of 11 KV switchgear panel in all respect.
Separate earthing of 3 Nos. 11 KV switchgear with help of 4 Nos. G.I. pipe 3 Mtr. long will be penetrate in earth duly interconnected at the distance of 3 Mr. each as per RESSPO drawing No. RES-40 at both end of cable trench and G.I. strip 50 x 6 mm with clamping from earthmat to switchgear complete including cost of materials.
Erection, grouting and mounting of CT structure. fitting of “CT” on erected structure with complete earthing.
Erection, grouting and mounting of PT structure. fitting of “PT” on erected structure with complete earthing.
Erection, grouting and mounting of Fuse Set structure. fitting of “Fuse Set” on erected structure with complete earthing.
Erection grouting and mounting of following structure.
33 KV Bus Isolator structure
33 KV fuse set structure
33 KV Post insulator structure
33 KV L.A. structure
33 KV fuse set ( Copper strip as required size for 33 KV fuse set)
Earhing of outdoor type switchyard earthing for newly erected structure as per proper specification with GI Earthing strip.
Jumpring form 33 KV Bus bar to post insulator, bus isolator, VCB, CT and LA to 5 MVA transformer etc.( Providing alluminium Lug and PG Clamp)
Construction of approach road inside the switchyard 1.5 Mtr. wide with 1st class bricks on edge soling and tipping complete work including cost of all materials.
Providing following control cable and its laying form switchyard to control room 33 KV panel by digging trench in switchyard including cost of sand and 1st class bricks with covering and making connection complete and including cost of laying.
Dismentaling of old TG of Existing Bus bar due to extension of bus bar.
Erection and grouting of TG for extension of Bus -Bar ( TG provided by contractor )
Safly Dismentaling of old Bus bar and extention of bus bar.with Disc Insulator and others required materials.
Safly Dismentaling of Single ST.Pole /Rail Pole
Saflty Out of ground existing 11 KV cable and re- laying of existing cable and hanging of cable due to Construction of power transformer plinth for 5 MVA
Tree Cutting due to Bus Bar extesion
Shifting,Loading Carriage & Unloading of old and damaged ST pole and damaged existing TG from work site to store centre Deoria Distt. Deoria
Painting of newly erected structure in switchyard (Applying on coat of good quality red oxide primer then two coat of good quality of high class luxol aluminium paint)
Ravi Traders
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .