Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC 32 06 PEST HOUSE NARONA CHAURAHA MALL ROAD POST BOX NO 49 KANPUR 208001 UP | KANPUR | KANPUR | UP | 208001 | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | L2₹37.0 L+₹2.6 L (7.59%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹40.1 L+₹5.7 L (16.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Firm banned by HQ CE (AF) Allahabad in WLR QE SEP 2022 |
Tender Value
₹43.7 L
EMD Value
₹87,400
Closing Date
14 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BIHTA
Air force Station Bihta 801103
IMPROVEMENT/UPGRADATION TO L/IN ACCN OF AIRMEN AT AIR FORCE STATION BIHTA ( PHASE-II)
2023_MES_576061_1
8277/BHT/E8
Open Tender
Civil Works
Item Rate
180 days
BIHTA
Class D category a(i)
7 documents required · 7 mandatory
₹500
GE AF BIHTA
₹87,400
Yes
17 Mar 2023
19 Jan 2023
16 Feb 2023
19 Jan 2023
14 Feb 2023
2 Feb 2023
20 Jan 2023 - 27 Jan 2023
Amount
Dismantling of stone stabs & tiles of any description or thickness in floor, aprons etc and bedded & pointed in cement mortar and disposing off debris to a distance up to 250 m, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises to a distance upto 250M, complete all as specified and directed.
Dismantling of brick work or stone/boulders masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removing all rubbish material to a distance upto 250 m, complete all as specified and directed.
M&L for roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc., complete all as specified and directed.
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick/concrete surfaces in CM 1:6 finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 with using WPC as per manufacturer's instructions, finishing surfaces even and smooth without using extra cement, complete all as specified and directed. (Note: WPC shall be measured and paid separately under appropriate item.)
M&L rendering 5 mm thick in CM 1:3 on concrete surfaces of ceiling, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying a layer of 1-1.50 mm thick wall care putty and over it applying two coats oil bound distemper over a coat of alkali resistant primer, complete all as specified & as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats cement based paint over a coat of primer, complete all as specified & as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed.
M&L for preparation of old previously treated surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
M&L for complete removing of existing treatment from wall surfaces and applying two coat of cement base paint over a coat of primer, complete all as specified and directed.
M&L for complete removal of existing treatment from walls and applying a layer of 1-1.50 mm thick wall care putty and over it applying two coats oil bound distemper over a coat of alkali resistant primer, complete all as specified & as directed.
M&L for old painted wooden surfaces and applying one coat of synthetic enamel paint (ordinary tint) of any description, over 10 cm in width or girth, not otherwise described, complete all as specified and directed.
M & L Granite 20 mm thick (Telephonic black) work (table rubbed and polished) in steps, jambs, pillars, window-cills, Wash basin platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L Non skid ceremic tiles 7 to 8mm thk (square/ rectangular)area of each tile exc. 0.06sqm but not exc. 0.11sqm, in floors etc , set and jointed in neat cement sluury and pointed in white or coloured cement to match the coloured tiles, laid over and including 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes, complete all as specified and directed.
M & L glazed ceramic coloured tiles of approved quality ISI marked (350 X 250 X 7 mm / 450 x 350 x 7 mm / 450 x 300 x 7 mm thick) as in vertical surfaces such as skirting, dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles, laid over and including 10 mm thick cement mortar 1:4 backing on brick work and concrete surface, complete all as specified and directed.
S&F in repairs 10 Ltr capacity vitreous china valveless syphonic action type flushing cistern, low level, coloured with inlet, ball valve, float and handle incl PVC flush pipe of 32 mm dia, fixed to wall, complete all as specified and directed. (Note: Removal of any type of flushing cistern, low/high level is deemed included in quoted rates)
S&F in repair bib tips cast copper ailoy, fancy type, half turn, chromium plated, screwed down, screwed for iron pipe or for brass furrule and fixed for 15mm dia pipe, complete all as specified and as directed.
S&F in repairs stop valves, fancy type, half turn, chromium plated brass with long shank and cup (Concealed type), screwed down, high pressure, both ends screwed to iron pipe or for union, dia of pipe 15 mm, complete all as specified and directed.
S&F in repair stop valves cast copper alloy, fancy type, half turn, chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for union, dia of pipe 15 mm, complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flushing cistern, complete all as specified and directed.
S&F in repairs vitreous china half stall type urinal, white with CP brass grating and union for discharge pipe and PVC waste pipe of 40 mm bore, including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back with white cement, complete all as specified and directed.
S & Fixed in repair Vitreous china wash basin, white, oval type size 560x410 mm, including waste pipe and plug and porcelain stopper alongwith 32mm dia CP waste coupling and PVC waste pipe, complete all as specified and directed.
S&F in repair 15 mm bore fancy type pillar taps, cast copper alloy, with capston heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts, screwed to PVC Connection and fixed, complete all as specified and directed.
S&F in repair shower rose, chromium plated brass, fancy type, 125 mm size with swivel joint, screwed to iron pipe or for union of 15 mm dia, complete all as specified and directed.
S&F PVC (SWR) floor trap including jointing to waste pipe with solvent cement, diameter of outlet 75mm, provided with and including stainless steel grating, complete all as specified and directed.
Taking up or down steel tubing 15 mm dia and connections including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down steel tubing 20 mm dia and connections including cleaning for refixing or removal to store, complete all as specified and directed.
Taking up or down steel tubing 25 mm dia and connections including cleaning for refixing or removal to store, complete all as specified and directed.
Cutting chases pinning in, making good to facing where required and pointing in CM (1:3) to ends of edges of landings, shelves, cills, lintels etc and making good cutting, girth not exc 10 cm, in brick walls, complete all as specified and directed.
S&F 15 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
S&F 20 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
S&F 25 mm dia GI tubing, medium grade, with all fittings and fixed complete to walls, ceilings and floors complete all as specified and directed.
Demolition and breaking up drain pipes and fittings, salt glazed ware, AC, PVC or RCC, internal dia of pipe 100 mm, complete all as specified and directed.
Demolition and breaking up drain pipes and fittings, salt glazed ware, AC, PVC or RCC, internal dia of pipe 75 mm, complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
S&F PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and laid in trenches/floor, complete all as specified and directed.
S&F PVC (SWR) bend 110 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
S&F PVC (SWR) 110 mm bore single Junction 'T', equal or unequal, incl jointing to waste pipe with solvent cement, complete all as specified and directed.
S&F PVC (SWR) bend 75 mm bore, any radius, incl jointing to waste pipe with solvent cement, complete all as required and as directed.
M&L brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for plain cement concrete, 25 mm thick, 1:2:4 mix using 20mm graded stone aggregates as in levelling course in floor and roof tops etc, complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed.
M & L Marble work 18 to 20mm thick (table rubbed and polished) in floors for border work in kota stone flooring, and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble of any shade over 20 mm thick screed bed in cement mortar (1:6), complete all as specified and directed. Note : Shade and tint of marble as approved by GE.
M&L for machine cut kota stone slab as in skirting, dado, risers etc, 18 to 20 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing, laid over and including 10 mm thick CM 1:4 backing, complete all as specified and directed.
Demolition/Dismantling of existing normal roof treatment, any type from RCC roof slab including lime concrete/PCC padding over roof, removing layer of bitumen under lime concrete/PCC padding, cement mortar, felt etc and cleaning the surface by hacking to receive plaster and removing demolished materials outside MD land, complete all as specified and directed. Note :- (a) The surface shall be wired brushed and cleaned to receive the PCC/plastering. (b) Any mechanical item such as Solar panel system incl its water tank and other accessory shall be removed and refixed after necessary repair work. The rate for the same shall be deemed included in this item.
M&L for rendering 10mm thick in CM 1:3 on concrete surfaces /roof slabs, finished even and smooth without using extra cement with admixture of integral water proofing compound @ 3% by weight of cement for filling depressions if any to receive water proofing treatment, complete all as specified and directed. (WPC shall be measured & paid seperately)
M&L for applying bitumen primer @0.30 Ltr/sqm, applied evenly over plastered surfaces of roof including cleaning of roof surfaces, complete all as specified and directed.
M&L for applying evenly a tack coat of bitumen 85/25 grade @1.2 kg per Sqm on primed roof surfaces, complete all as specified and directed.
M&L for providing APP based 5 layer polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyester non-woven fabric (weight not less than 150 gms/sqm) centre core, laid on roof surfaces by torch application immediately after applying tack coat as per the manufacturer's instructions with side over lap of 75mm and end over lap of 100mm, complete all as specified and directed.
M & L 40mm thick brick tiles laid on cement mortar mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement, laid over and including 20 mm thick screed bed of cement mortar in CM 1:4 with using WPC @ 3% by weight of cement, complete all as specified and directed. (Note :- WPC shall be measured and paid separatly)
Supply only approved ISI marked integral water proofing compound, complete all as specified and directed.
Closing bolt holes etc. with metal putty in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm self tapping screw, incl removing old tapping screw and all set in stiff white lead, bolt not exc 25 mm in length, complete all as specified and directed.
M & L Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surface, complete all as specified and directed.
Refixing of shutters exc. 1 Sqm but n. exc. 2 Sqm each in same or other opening after easing and adjusting including renewal of screws etc as required at site, complete all as specified and directed
Taking down Chowkats or frames with shutter (without taking taking off shutters from the frame) n. exc. 1.50 Sqm each, complete all as specified and directed.
S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as specified and directed.
S&F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stile) with 2, 4 or 6 raised panels designed with 2 mm thick moulded PVC sheet on the front face and 2 mm plain coloured PVC sheet on back face, supplied and fixed to frame at site as per specification and drawing with particle board core, complete all as specified and directed.
S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed, complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type, anodised 125 mm size complete all as specified and directed.
S & F Aluminium powder coated anodised frame for ventilator incl joining cleats & rubber beading for fixing for glass, wire mesh etc, complete all as specified and directed.
Supply only sheet glass 3 mm thick frosted, ordinary quality and cut to required size for fixing in aluminium frames, complete all as specified and directed. (Cost of fixing shall be deemed included in the unit rates of aluminium frames.)
Supply only stainless steel wire cloth with 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and cut to required size for fixing in aluminium frames, complete all as specified and directed. (Cost of fixing shall be deemed included in the unit rates of aluminium frames.)
Disconnecting existing water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside (or lowering of required) for repairs to roofs etc. and hoisting if required reconnecting and refixing in position on roof, complete all as specified and directed.
S&F in repair ball valve 20 mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 210 grams) complete all as specified and directed.
S&F in repairs gun metal globe or gate valves of 20mm dia pipes with iron wheel head screwed both ends for iron pipe or for unions, fixed in repairs etc, complete all as specified and as directed
M&L 75 mm thick PCC 1:4:8 type D-2, using 40 mm graded stone aggregate, as in sub base of floors etc, complete all as specified and directed.
Taking down carefully copper / Aluminium point wiring (Light/Fan/Socket/power) complete including fittings and fixtures such as switches , ceiling roses , pendents , regulators , sockets , light fittings etc. and making good the disturbed surfaces of walls/ floors etc complete all as specified and as directed by Engr-in-Charge.
Taking down submain wiring of any size /description from wooden battens/PVC conduits from walls/floors/ceiling etc., complete and making good the disturbed area complete all as specified and as directed by Engr-in-Charge.
Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceiling etc, to match with the existing surfaces, complete all as specified and as directed by Engr-in-Charge.
M&L for point wiring with 1.5 Sqmm, PVC insulated but unsheathed, stranded copper conductor single core FRLS cable, 1100 volts gradeIS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia (medium grade) or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel terminal switch box 1.6mm thick with bakelite laminated sheet top cover 3mm thick, brass screws and cup washers including 1.5 Sqmm dia stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for:- (a) One light/fan/exhaust fan/bell point controlled by 1 No. one way 5/6 Amp switch/bell push.
(b) One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board.
(b) One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches, fan regulator etc.
Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable FRLS of size 2.5 Sqmm stranded for earth continuity wire, to be drawn in rigid PVC medium grade concealed conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and phenolic laminated sheet cover 3.0 mm thick and brass screws with cup washers for one socket outlet 15 amp on independent board including all necessary wall cutting and making good disturbed surface all as directed and specified. Note for item of point wiring: Rate for wall cutting for switch/terminal boxes & chase cutting for concealing conduits and making good disturbed surfaces to match with the adjoining surface shall be deemed included in the unit rate.
S&F switch piano flush button single pole one way 6 Amp, 220 Volts, complete all as specified and as directed by Engr-in-Charge.
S&F switch socket combination, 5/6 Amps, 220 volt, multi pin, flush type, universal, complete all as specified and directed.
S&F switch piano flush button single pole one way 15/16 Amp, 220 Volts, complete all as specified and as directed by Engr-in-Charge.
S&F for socket outlet, 6 Pin, 15 Amp flush type, 220 Volts, complete all as specified and as directed by Engr-in-Charge.
S&F bell push piano, flush type 5/6 Amps, 220 volts AC,single pole, complete all as specified and directed.
S&F Call bell AC 220 Volts, single pole, ding dong sound, complete all as specified and directed.
S&F Ceiling rose, surface bakelite, 65x20 mm, three terminal, complete all as specified and directed.
S&F stepped type electronic fan regulator, flush type, 230 volts AC, single pole, humming free, fixed on the existing phenolic laminated sheet, complete all as specified and directed.
Supply and fixing LED tube light fitting 1x 22W, 220V, including inbuilt LED driver and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and complete all as specified and directed by engineer-in-charge.
S&F round shape 12 watt, 220 volts AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holder, LED lamp, suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm, sweep with, blades, and frame and louvers, complete all as specified and directed.
S&F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps, complete all as specified and directed.
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one single pole MCB of "C" series of cap 6-32 Amps including taking out the old one complete all as specified and as directed by Engr-in-Charge.
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching including taking down old one complete all as specified and as directed by Engr-in-Charge.
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 12 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching including taking down old one complete all as specified and as directed by Engr-in-Charge.
S & F MCCB TPN, 415 V, fixed thermal and fixed magnetic settings, 125 Amps with breaking capacity 16 KA, complete all as specified and directed.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 sqmm as current carrying conductor and one run of 4 sqmm as neutral cable, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated, unshealthed, stranded copper conductor of size 4 sqmm, complete all as specified and directed.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6 sqmm as neutral cable, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated, unshealthed, stranded copper conductor of size 6 sqmm, complete all as specified and directed. Note for sub main wiring:- Two runs of single core FRLS PVC cable with one run of earth contunity conductor and one run of pvc conduit shall be measured as one unit.
Disconnecting and taking down carefully ceiling fan/exhaust fan and refixing after cleaning, oiling/greasing and connecting with suitable size copper conductor cable, complete all as specified and directed.
M&L for painting of ceiling fans/exhaust fans of any sweep with one coat of synthetic enamel paint applied with spray machine, including filling cavities with filler after cleaning of surfaces, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to test point /machinery / equipment. supplying and laying charcoal dust comman salt PCC (1:2:4) type B1 using 20 mm graded stone agregrate chamber and RCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1 using 20 mm stone agrigrtae ) reinforced with 8 mm dia TMT bars @ 75mm C/C both ways with mild steel handle 12 mm dia, using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1 including testing and taking out the old one complete all as specified and directed Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.
Bikarma Enterprise
BRIJESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .