| 1 | L1₹24.7 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹25.8 L+₹8,373 (0.33%)Rejected-Finance OPP SHRI NAVNIKETAN H S SCHOOL CHHOLA KANCHI BHOPAL M P | BHOPAL | MADHYA PRADESH | 462010 | L2 | Rejected-Finance Higher | |
| 3 | L3₹26.6 L+₹91,730.50 (3.57%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Higher | |
| 4 | L4₹30.4 L+₹4.7 L (18.4%)Rejected-Finance | L4 | Rejected-Finance Higher |
Tender Value
₹27.3 L
EMD Value
₹54,600
Closing Date
4 Feb 2019, 6:00 pmClosed
GE (AF) Amla
GE (AF) Amla Amla Depot Dist Betul (MP) 460553
Repair/maintenance of Rewiring and fitting fixtures at 28 ED AFS Amla
2018_MES_229818_2
8292/E8 of 2018-19
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Amla
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹54,600
Yes
28 Mar 2020
15 Jan 2019
5 Feb 2019
15 Jan 2019
4 Feb 2019
16 Jan 2019
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fitting fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. complete all as specified
Taking down ceiling fans of any size/sweep after disconnecting the wire from existing ceiling rose and refixing the same after cleaning dust, oiling, greasing including providing flexible cable from ceiling rose to connector of fan complete all as directed by Engineer-in-Charge
M&L for point wiring using approved colour coding as per IS with 1.5 sqmm two single core PVC insulated but unsheathed FR cable, 1100 volts grade, ISI-694 marked with multistranded copper conductor and earth continuity wire with similar 1.5 Sqmm cable (including connecting to earth dolly) drawn through ISI Marked heavy duty rigid PVC concealed conduit with all accessories etc with mild steel sunken box duly,concealed in wall and having PVC modular cover plate with frame suitable for modular switch/Sockets/regulators for the following :-
One light / fan controlled by one switch one way.
One light point controlled by two 2 way switch.
One 3 pin socket outlet 05 Amp on same board with other switches
One 3 pin socket outlet 05 Amp on independent board.
One bell / buzzer point controlled by one bell switch
All as per item No : 03 but for point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board.
All as per item No : 03 but for point wiring but for AC box (sheet metal enclosure) with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core cable.
M&L for point wiring using approved colour coding as per IS with 1.5 sqmm two single core PVC insulated but unsheathed FR cable, 1100 volts grade, ISI-694 marked with multistranded copper conductor and earth continuity wire with similar 1.5 Sqmm cable (including connecting to earth dolly) drawn through ISI Marked PVC Casing caping with all accessories etc with mild steel sunken box duly conceled in wall and having PVC modular cover plate with frame suitable for modular switch/Sockets/regulators for the following :-
One light point controlled by one No one way switch
One three pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One bell / buzzer point controlled by one bell push
All as per item No 6 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board.
All as per item No : 06 point wiring but for AC box (sheet metal enclosure) with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core cable.
M&L for point wiring using approved colour coding as per IS with 1.5 sqmm two single core PVC insulated but unsheathed FR cable, 1100 volts grade, ISI-694 marked with multistranded copper conductor and earth continuity wire with similar 1.5 Sqmm cable (including connecting to earth dolly) drawn through ISI Marked PVC Casing caping with all accessories etc with mild steel sunken box duly conceled in wall and having ISI marked Hylem sheet suitable for piano type switch/Sockets/regulators for the following :-
One light/ Fan point controlled by one No one way switch
One three pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One bell / buzzer point controlled by one bell push
All as per item No 9 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board.
M&L in repair for submain wiring with approved colour coding as per IS in replacement with 2 runs of 1.5 Sqmm size main cable and one run of 1 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through surface mounted heavy duty marked rigid PVC Conduit of size 25mm dia with all fittings accessories including making good the surface on wall etc complete(Note- 2 run of 1.5 sq mm and one run of 1 sq mm and one run of heavy duty PVC Conduit will be measured as one unit)
M&L in repair for submain wiring with approved colour coding as per IS in replacement with 2 runs of 2.5 Sqmm size main cable and one run of 1.5 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through ISI Marked heavy duty PVC conduit of size 25 mm dia with all accessories etc including making good the surface on wall etc complete.(Note- 2 run of 2.5 sq mm and one run of 1.5 sq mm and one run of heavy duty PVC conduit will be measured as one unit )
M&L in repair for submain wiring with approved colour coding as per IS in replacement with 2 runs of 4 Sqmm size main cable and one run of 2.5 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through ISI Marked PVC Casing caping with all accessories etc including making good the surface on wall etc complete.(Note- 2 run of 4 sq mm and one run of 2.5 sq mm and one run of PVC casing capping will be measured as one unit )
M&L in repair for submain wiring with approved colour coding as per IS in replacement with 2 runs of 6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through Concealed heavy duty ISI marked rigid PVC Conduit of size 25mm dia with all fittings accessories including making good the surface on wall etc complete(Note- 2 run of 6 sq mm and one run of 4 sq mm and one run of heavy duty PVC Conduit will be measured as one unit)
M&L in repair for submain wiring with approved colour coding as per IS in replacement with 4 runs of 6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FR cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked drawn through Concealed heavy duty ISI marked rigid PVC Conduit of size 25mm dia with all fittings accessories including making good the surface on wall etc complete(Note- 4 run of 6 sq mm and one run of 4 sq mm and one run of heavy duty PVC Conduit will be measured as one unit)
S&F in repair modular switch 01 way 6 Amp , 01 module complete
S&F in repair modular switch 02 way 6 Amp , 01 module complete
S&F in repair modular switch 01 way 16 Amp , 01 module complete
M&L in repair Modular bell push 6 amp 230 volt 50 hz AC supply one way, complete all as specified
S&F in repair modular socket 6 Amp , 2 module complete
S&F in repair modular socket 6 / 16 Amp , 02 in 01 , 02 module complete
S&F in repair modular step fan regulator 120 watt 2 module suitable for 230 Volt 50 Hz supply all as specified
S&F in repair Switch piano flush type single pole one way, and 6 amp complete ISI mark
S&F in repair Socket outlet multipurpose having provision for 2 in 1, 3 pin 5 amp piano flush type complete all as specified
S&F in repair Switch piano flush type single pole one way, and 15 amp complete ISI marked.
S&F in repair socket outlet 2 in 1, 2/3 pin 5 Amps and 15 Amps flush type.
S&F in repair bell push 6 amp 230 volt 50 hz AC supply flush type one way, complete all as specified
Supply & fix in repair Bell multi music type complete
S&F in repair stepped type electronic fan regulator Socket type on the existing phenolic laminated sheet, etc. as required
S&F in repair ceiling rose surface Bakelite 3 terminals 230V 50 Hz ISI marked.
S&F in repair Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fitting completes all as specified.
S & F highly efficient LED retrofit Lamp 9W used as a ready replacement for existing GLS/CFL of make Philips/Havells/ Crompton all as specified and as directed.
S&F in repair for wall mounted LED 10W CRCA fitting 230 V with extruded aluminium heat sink provided for efficient heat dissipation and integeral electronic driver connector block etc complete with all accessories internally prewired including neccessary mounting arrangement , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including neccessary polycarbonate LED tube 2FT 10 W complete all as specified and directed. Cat No TARA-M/10W of make C&S or equivalent in Havelles/Philips
S&F in repair for wall mounted LED 20W CRCA fitting 230 V with extruded aluminium heat sink provided for efficient heat dissipation and integeral electronic driver connector block etc complete with all accessories internally prewired including neccessary mounting arrangement , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including neccessary polycarbonate LED tube 4FT 20 W complete all as specified and directed. Cat No : LT8 20-865-2 for Rod & DML N1 LT8-16 for batten of Crompton, BLRB18W for Rod & BLRBDB118 for batten of Bajaj, LHDDBXEUL7Z020 for Rod and LMFYBW1TB1W020 of Havels
Supply & fix in repair decorative wall mounted energy saving 03 watt LED bedside light fitting flexible and adjustable to any direction with integeral electronic driver complete with all accessories Cat Part No 48042 of philips or equivalent in Havells/Bajaj/Crompton
Supply & fix in repair decorative cylendrical shaped energy saving LED Bollard light fitting 08 to 10 watt 1000 mm long pressure die cast powder coated housing with diffuser with integeral electronic driver connector block etc complete with all accessories internally prewired with neccessary mounting arrangement complete all as specified and directed. Cat Part No MAYAI LBLA1-10-CDL of crompton, 111282 BGBOL 605 9W LED of Bajaj, LHENAXP7PZ6K008 (BAMBOO) of Havells
M & L for PCC (1:4:8) type D2(using 40 mm graded stone aggregate ) as in foundation of poles and similar works, filling mass concrete complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply, lay, joint, test and commissioning of XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 6 sqmm 2 core
M & L in repair for wall mounted GI Bracket as per sample suitable for 25 Watt building security light with necessary clamps and nut bolts all as specified and directed.
S&F in repair for environment friendly high efficiency with better thermal management type building security light 25Watt with integeral electronic driver connector block etc complete with all accessories internally prewired including neccessary mounting arrangement, provision of 2 core 1 Sqmm multistranded copper conductor from ceiling rose to fitting complete all as specified and directed. Cat Part No ASTRA LSTS-25-CDL of crompton, Edqe Plus series 169826 BRLEP 25W LED WH of Bajaj, Endura city Lite platinum TGL LHETAXU7PA6S025 of Havells
S&F in repair for MCB DB TPN 4 way double door sheet metal enclosure comprising of 200 Amps, 415 Volts, 50 Hz bus bar and neutral link complete complete all as specified.
S & F in repair MCB triple pole and neutral 415 Volts, 63 Amps, 10 KA.
S&F in repair for MCB DB SPN 12 way double door sheet metal enclosure comprising of 200 Amps, 415 Volts, 50 Hz bus bar and neutral link etc complete all as specified.
S&F in repair for MCB DB SPN 08 way double door sheet metal enclosure with 200 Amps common bus bar and neutral link compete to fixtures
S & F in repair 'C' curve MCB single pole & neutral 240Volts 40 Amps.
S&F in repair 'C' curve MCB SP 240 volt 6 to 30 Amp
S&F in repair for single pole and neutral sheet metal enclosure with a two pin earth plug and socket etc with 1 SPN MCB 240 Volts 20 Amps complete.
M&L for telephone wiring as per IS with suitable size of telephone wire drawn through heavy duty ISI marked rigid PVC conduit conceal in wall/ceiling for one no telephone socket on same board complete all as directed by Engr - in - Charge .
Supply & fix modular telephone socket , heavy duty complete all as directed by Engr- in -Charge .
M&L in for TV cable wiring with suitable size of TV cable drawn through heavy duty ISI marked rigid PVC conduit conceal in wall for one no TV socket on same board complete all as directed by Engr - in - Charge .
Supply & fix modular TV cable socket , heavy duty complete all as directed by Engr- in -Charge .
S&F in repair 3 pin plug top, 16 amp capacity, 240 VAC, heavy duty, ISI marked
Supply & fix in repair ISI marked heating element of rating 1.5 KW for vertical Geysers as required at site including rubber washers etc.
Supply & fix in repair thermostat ISI marked suitable for the vertical Geysers 25 ltrs. to 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample
Supply & fix in repair PVC connections pipe with brass hexagonal adapters both side. Suitable for 15mm dia pipe 60cm long for HOT & Cold water as per requirement..
Supply only GI tubing light grade size 40 mm complete
Fixing only of GI tubing light grade size 40 mm on wall for hanging of ceiling fan including civil works , cutting of GI tubing and clamps with nuts , bolts & wshers and making good surface area complete all as specified and directed by Engr - in - Charge .
M&L for making of hole in exsiting wall for exhaust fan size 250/300 / 400 mm dia including all civil work and making good surface area as per existing all as specified and directed by Engr - in - Charge .
Supply & fixing in repair of Exhaust fan , PVC body , size 250 mm , Single phase , 230 Volts including providing flexible copper cable from ceiling rose to connector of fan complete all as directed by Engineer-in-Charge. (Make :- Ventil Air-DX WHT of Havells or equivalant in Bajaj / crompton)
Supply / Fixing / connecting & testing of ceiling fan size 1200 mm sweep single phase , 230 Volts complete , Make : Bajaj / Usha / Havells with suitable length of down rod as per ground condition all as directed by Engr - in - Charge .
Supply and lay in trenches / fixed to walls PVC pipe 32/40 mm dia class 3 grade for protection of XLPE cable all as specified and as directed. NOTE :- Rates for flat iron clamps, bolts, nuts and washer etc are deemed to be included in rate quoted.
S & F three phase 4 wire directly connected Prepaid Energy Meter, 10-60 Amp, 240V, Accuracy class 1.0 with Polycarbonate seal, RJ11 cable 02 RM and transparent polycarbonate meter box. Make : Secure/ Orbit/ Arihant
S&F in repair CMRI Certified LED Flame proof 40w bulkhead fitting,Recommended for ammunition Shed ,IP 65 protection complete with all accessories internally pre- wired complete all as specified and as directed Make : Crompton Greave Cat No. FWL1315 or equivalent in Sudhir/Bajaj
S&F in repair CMRI Certified LED Flame proof 2X16/20 W,Tube light fixture,Recommended for ammunition Shed ,IP 65 protection complete with all accessories internally pre- wired complete all as specified and as directed Make : Crompton Greave Cat No. EXTN1LT8 or equivalent in Sudhir/Bajaj
Disconnecting / taking out carefully old unserviceable LT Feeder pillar box and making good the disturbed surfaces including Supply, Installation, Testing & Commissioning Factory made wall monted LT feeder pillar box {CPRI approved } 440V AC ,Compartmentalized , in door type in 1.6 MM thick CRCA Sheet of Appropriate Size, Front Open Double Doors, Dust & vermin proof, Cable Entry through Gland plates - Bottom only, Powder Coated , 3Phase HR Sleeved Colour Coded Aluminium Main Bus bar of 250 Amp , 03 No’s along with one Neutral Half Bus bar . Wiring with 10 Sq mm Size of Copper wire ( FRLS ) ,Cable glands brass chromium plated of different sizes suitable for incoming MCCB' 125 Amp and fitted with following specified items:- (a) MCCB 4 POLE 415 Volt , 125 Amp , Thermal Release Range 35 KA , Make : L&T / Lerand / Havells - 01 No (b) Bus bar chamber (c) MCCB 4 Pole 63 Amps 25 KA - 04 No Make : L&T / Lerand / Havells (d) MCB SPN 25A -01 Nos (e) Space for prepaid Energy meter, digital type three Phase , with optical port - 04 Each . Note - (i) MCCB's must be Fixed Vertically in LT feeder pillar box . (ii) " AS PER CPRI APPROVED "must be Write on right top corner With riveted separate plate. (iii) ) A separate locking arrangement ( Sliding bolt type ) must be made in LT panels.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. light grade protection pipe for earth lead complete with charcoal and common salt in alternate layer including watering arrangement with galvanized iron pipe medium grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. (Note :- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.)
M&L for plate earthing for complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of equipments etc at the other end , earth strip encased in and including 40 mm bore GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 3 mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with wire mesh , funnel and earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No -3 of SSR Pt-I. (Note :- GI earth strip 25x4 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.)
Supply and fix RGB 18 w LED under water light with all accessories and mounting arrangment for under water purpose complete all as specified and directed Make : Teknolite
Supply and fix junction box IP 65/IP55 with metallic knockouts for cable entry. Box size 200x160x98mm with terminls sealing ring and lockout nut complete all as specified and directed. Make Cat No K9255 of Hansel or equivalent
Note:- (i) The amount against Schedule of Credit on Page No. 28 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contarct Sum for Acceptance.
NIHAL ENTERPRISES
Shri Sai Enterprises
AMBIKA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .