No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
14 conditions · 2 needing a document upload
The tenderer must have a minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VI B (GCC-April-2022), along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (As per clause No.10.1 of GCC-2022 and latest amendments) and Chapter-II & III of tender documents. (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during the last 07 (seven) years, ending the last day of the month previous to the one in which the tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender (b)(i) In the case of composite works (e.g., works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges substructure, superstructure etc.), the tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note: Separate completed works of minimum required values for each component shall also be considered for the fulfilment of technical eligibility criteria. (b) (ii) In such cases, what constitutes a component in a composite work shall be predefined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of the tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be executed by the tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through the subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through a subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarized, legally enforceable in the court of law, shall be executed by the main contractor with the sub-contractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards the fulfilment of technical eligibility. Such subcontractor must fulfil technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to the work proposed for a subcontract, costing not less than 35% value of the work to be Sublette, in the last 5 years, ending the last day of the month previous to the one in which tender is invited through a works contract.
Defination of Similar Work :- Supply, installation, testing and commissioning of IP Based Video Surveillance system anywhere in India or abroad". Bidders having experience in IP Based video surveillance system works carried out in India or abroad for work done in Government / Semi- Government / PPP organizations only will be considered.
4 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Technical and functional requirements Provision of Supply, installation testing and commissioning of cctv cameras at Arag, Bhigwan, Bale, Dharashiv, Kurduwadi, Latur, Pandharpur, Solapur, Taj Sultanpur and Wadi over SOLAPUR Division, Central Railway on SOLAPUR Division Central Railway. The Supply, Installation, Commissioning and Testing of all Schedule Items must be as per specifications as specified in the Tender Schedule and Tender Documents to the complete satisfaction of Railways. Any other items which are not included in this tender schedule but required for smooth functioning of the system to be supplied and installed by the contractor at no additional cost. The subject work is very sensitive in nature and is in the interest of Railway safety purpose at 10 for Goods sheds over SOLAPUR Division, Central Railway.
Scope of the work includes provision of CCTV Cameras as above mentioned Goods & Parcel offices. The cameras are to be fitted on metallic poles. The video data of these cameras to be stored in NVR. The NVR and associated accessories / items to be installed inside the Goods Sheds. This technical specification should be read in conjunction with concerned clauses of STQC specifications mentioned in the tender schedule. The requirements are mainly based on STQC specification as per latest guidelines. The tenderer shall submit MAF (Manufacturer's Authorization Form) from OEM (original equipment manufacturer) at the time of material supply, for items such as cameras, NVR/Servers, UPS and Video display; stating that the OEM will support availability of spares and/or software / firmware including services for at least 5 years beyond the date of installation of CCTVs. Tenderer shall submit detail specifications/brochures of the offered items along with para wise compliance against STQC / tender specifications. For ensuring protection against hacking and other types of threats and vulnerabilities for vital equipment, the bidders while selecting OEMs of equipment and hardware (proposed to be supplied against this tender) are advised to avoid those products and/or OEMs which are suspected to have clandestinely embedded spyware/malicious code either in embedded form or in application software to hack or intercept data and intrude into the network. In this context the bidders are requested to refer advisories of bodies like CERT-IN and also reports published in various international media, technical journals, trusted websites etc. The items of the tender schedule having as per STQCs specifications unless otherwise mentioned shall be conforming to various clauses of the aforesaid specifications and shall fully comply the scope of work described in clause 2.2 in chapter 2 of Special Condition of Contract (SCC) of the tender document. All the materials and workmanship used in this work shall be of extremely good quality and high class in every respect and is expected to give trouble free service. The equipment/materials as per STQC specifications are to be procured from the STQC approved sources only
Regulatory Approvals/ Certifications: The IP Colour Cameras shall have security features which can be deployed meeting all the parameters applicable to cameras with relevant and equivalent safeguards as per Essential Requirements (ERs) latest as issued by MeitY, as specified in STQC Specification- 'to be submitted by the tenderer in advance. STQC, to ensure security of the Cameras, Software and other IT Items from vulnerabilities & breaches and discourage false undertaking from OEMs, security auditing and testing of equipment including source code of camera and software shall be carried out from STQC (Ministry of Electronics & Information Technology) only. In order to ensure security of network and other IT equipment of VSS system, before bulk supply and installation, it is to be ensured that security auditing and testing at the time of POC (Proof of Concept) as well as at the time of completion of project are to be conducted. In case any security breach is found in the system at any stage including at POC level, immediate strict penal action shall be initiated against the erring party. Note : - 1.All of the certifications regarding Type Tests, Acceptance Tests, POC, STQC applicable for items in the tender schedule as specified in the STQC Specification- latest' to be submitted by the tenderer in advance. 2. The Regulatory Approvals / Certifications are to be provided from STQC (Ministry of Electronics & Information Technology) only. 3. The Regulatory Approvals/ Certifications are to be provided from NABL/NABCB accredited Labs or internationally reputed and accredited Labs/Agencies.
Supply, installation testing and commissioning of CCTV cameras at 1. Solapur, 2. Kurduwadi, 3. Pandharpur, 4. Dharashiv, 5. Latur, 6. Bhigvan, 7. Tajsultanpur, 8. Wadi, 9. Bale and 10. Arag Goods sheds (Total 10 Goods sheds) over Solapur Division, Central Railway
SUR-C-WORKS-CCTV-GOODS-SH
SUR-C-WORKS-CCTV-GOODS-SH
Open
Works - General
6 Months
Solapur, Maharashtra
₹0
₹2.9 L
4 May 2026
9 Apr 2026
20 Apr 2026
87 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,46,14,457.59 | ||
| — | 48.00 | — | — | ||
| Supply of wall mount 6U Rack Enclosures Networking/ Server Rack with power strip 5A socket 06 no. & MCB, Depth of the Rack: Upto 600mm, Transparent Toughened Glass used in front door, CRCA Steel rear door, with Secure Locks, Support cable entry from top or bottom, with fan tray and two nos. fans suitable for outdoor installation (IP 68 rated) make: Valrack/ Dyanamic Rack/ Digilink/ similar, Inspection: Consignee | — | — | — | 2,78,996.64 | |
| — | 12.00 | — | — | ||
| Supply of STP (shielded Twisted Pair) CAT-6 cable, the cable should be compliant to EIA/TIA 568 B/C standards from D-Link, Finolex., Lucent or DAX Make/similar (1Box-305 mtrs) (Inspection by Consignee) | — | — | — | 1,00,137.24 | |
| — | 3050.00 | — | — | ||
| Supply of FR CAT-6 UTP Cable suitable for 10 BASE-T/100BASETX/and 1000BASE-T (Gigabit Ethernet). Make: DLINK/ AMP/ Avaya/ Krone/ Bestnet/ Ambernet/similar Inspection: Consignee | — | — | — | 63,318 | |
| — | 120.00 | — | — | ||
| Supply of CAT-6 UTP RJ-45 patch cord (5mtr long) twisted stranded cable terminated with RJ45 modular plugs at both the ends. TIA/EIA-568-C.2 standard, Insulation Material : High Density Polyethylene, Outer Jacket: FR-PVC,Conductor diameter: 24 to 26 AWG,Conductor Metal : Bare Copper, Make D-Link/Similar, Inspection: Consignee. | — | — | — | 30,510 | |
| — | 12.00 | — | — | ||
| Supply of Gigabit Ethernet Media Converter Single Mode Single Fiber, SM, Sc, 1310 nm, Transmission Type: 10/100/1000MFDX/HDX, Wavelength: Single mode: 1310/1550nm up to 20Km, Power Supply: External 1A,+5VDC, Connector: UTP: RJ-45 connector, Optical: SC connector (Single Fiber), with all accessories like power adaptor, make: JT Optics /Digisol/ TPLink / similar. Inspection: Consignee | — | — | — | 77,959.8 | |
| — | 8000.00 | — | — | ||
| Supply of FRLS power cable 3 core 2.5 sq mm multi strand (36/0.3 mm dia) cable asper IS-694:2010 or latest, make :Havells /Polycab /Finolex/Similar. Inspection:Consignee | — | — | — | 5,33,200 | |
| — | 80.00 | — | — | ||
| Supply of 8 ports Gigabit Managed PoE+ Layer 2 Access 19 inch rack mountable switch with two Gigabit SFP ports duly OEM loaded from Cisco or HP or Juniper or Extreme/similar. (Inspection by Consignee) | — | — | — | 10,55,092.8 | |
| — | 10.00 | — | — | ||
| Supply of (cable nails) 12mm dia wire fastener circle cable clips with metal nail, set of 100nos. Make: Hi-plast or ssimilar. Inspection: Consignee. | — | — | — | 3,493.5 | |
| — | 12.00 | — | — | ||
| Supply of 1KVA Online UPS with min. 30 minute back up along with 03 Nos.12v/26Ah external battery (Quanta/ Exide) with terminal & accessories set. Model: Liebert GTXMT + CX1KVA (800W) UPS, Make: Emerson Liebert (Vertiev)/ APC/ Numeric/similar. Inspection: Consignee. | — | — | — | 3,14,660.28 | |
| — | 400.00 | — | — | ||
| Supply & fixing of Round PVC Passive Networking Flexible Pipe, 01- inch Dia, Zig Zag Outer Surface Pattern, Round Shape, with ISI Mark, make: Dutron/ TMT Plus/ similar Inspection: Consignee. | — | — | — | 3,848 | |
| — | 8000.00 | — | — | ||
| Supply of flame retardent PVC conduit pipe (lSl Mark), 25mmx1.5mm, This includes all required fixing materials such as screws, nut & bolts, washers, clamps, elbow, Tee, etc. make: Anchor/ AKG/ Precision/ Polycab/ similar Inspection: Consignee. | — | — | — | 3,09,760 | |
| — | 8000.00 | — | — | ||
| Running, laying of power cable/ data cable/ cat-6 cable through pvc pipes as per site engineer's instruction. All fixing material to be arranged by contractor. | — | — | — | 94,080 | |
| — | 1400.00 | — | — | ||
| Supply of Fire-retardant and corrosion-free 25x25/32/38 MM PVC Casing Capping, make Pressfit /PRESTO/ SGI/ similar, Inspection:Consignee. | — | — | — | 1,30,046 | |
| — | 1400.00 | — | — | ||
| Fixing of PVC conduit pipe on wall, bridges, platform shed complete with 'U' clamps and necessary fixture screws etc as per route given by site engineer of Railways. | — | — | — | 10,626 | |
| — | 80.00 | — | — | ||
| Supply of 2 MP EXIR VF Bullet Network Camera, Image Sensor : 1/2.7" Progressive Scan CMOS, Resolution : 1920 x 1080, Lens Type : Fixed lens, 2.8/4 mm, Aperture: F2.0, IR Range : Up to 30 m, video resolution : 1920 x 1080, Video Compression : Main stream :H.265 +/ H.265/ H.264+/ H.264, Sub-stream :H.265 /H.264/ MJPEG, Audio Compression :G.711/ G.722.1/ G.726/ MP2L2/ PCM, Basic Event : Motion detection, video tampering alarm, exception (illegal login), Image Enhancement : BLC, 3D DNR, Day/Night Switch : Day/ Night / Auto/Schedule, Protocols : TCP/IP, ICMP, HTTP, HTTPS, FTP,DHCP, DNS, RTP, RTSP, RTCP, NTP, IGMP, QoS, UDP, API : ONVIF (PROFILE S,PROFILE G), ISAPI, SDK, Communication Interface : 1 RJ45 self-adaptive Ethernet port, Audio : 1 audio input (built-in microphone), mono sound, Power Supply :12 VDC 5.5 mm coaxial power plug; PoE,IP66, Built-in microphone, make: Hi vision/CP Plus, model: Hikvision DS-2CD1023G0-IU/ Similar. Inspection: Consignee. | — | — | — | 7,32,992.8 | |
| — | 12.00 | — | — | ||
| Supply of 2MP IP Dome Camera, Image Sensor : 1/2.7" Progressive Scan CMOS,Day & Night : IR cut filter, Digital Noise Reduction : 3D DNR, Focal Length : 2.8/4mm fixed lens, Aperture : F2.0, Focus :Fixed, IR Range : Up to 30 m, Video Compression : Main stream :H.265 +/H.265/H.264+/H.264, Max. Resolution : 1920 x 1080@ 30fps,communication Interface : 1 RJ4510M/100M self-adaptive Ethernet port, Audio : 1 audio input (built-in microphone),mono sound, Audio Compression:G.711/G.722.1/G.726/MP2L2/PCM, Power Supply : 12 VDC, 5.5 mm coaxial power plug PoE, IP67, IP66 Built-in microphone, Basic Event : Motion detection, video tampering alarm, exception (illegal login),Image Enhancement : BLC, 3D DNR, Day/Night Switch :Day /Night/ Auto/ Schedule, make: Hikvision/CP PLUS/similar, model: HikvisionDS-2CD1323G0-IU/similar, Inspection: Consignee. | — | — | — | 58,639.44 | |
| — | 6.00 | — | — | ||
| Supply of 8 Channels DVR/NVR with 4K(3840 x 2160), IP video input : 8-chIncoming band width : 80 Mbps, Outgoing bandwidth : 160 Mbps, HDMI output resolution : 4K (3840 x 2160)/30Hz, VGA output resolution : 1920 x 1080/60Hz,Audio output : 1-ch, RCA, Decoding format: H.265/H.265+/H.264/H.264+/MPEG4,Recording resolution : 8MP, Synchronous playback : 8-ch, Capability : 2-ch @ 4K,SATA : 2 SATA interfaces, Capacity : Up to6TB capacity for each HDD, Network interface : 1, RJ-45 0/100/1000 Mbps self-adaptive Ethernet interface, USB interface : Front panel: 1 x USB 2.0; Rear panel: 1 x USB 3.0, Alarm in/out : 4/1,Power supply : 12 VDC, Make: Hikvision/CPPLUS/similar, Model: Hikvision DS-7P08NI-K2/ equivalent. Inspection: Consignee | — | — | — | 80,886 | |
| — | 6.00 | — | — | ||
| Supply of 16 Channels NVR with 4K (3840x 2160), H.265/ H.265+/ H.264/ H.264+/ MPEG4 video formats, Connectable to the third-party network cameras, Recording at up to 8 MP resolution, HDMI and VGA independent outputs, HDMI Video output at up to 4K (3840 x 2160) resolution, Up to 2 SATA interfaces connectable for recording and backup, 1 self-adaptive 10 M/100 M/ 1000 Mbps network interface, Connectable to IP cameras from ikvision and the recording, playing back, and backing up of VCA alarms, Centralized management of IP cameras, including configuration, information import/export, real-time information display, two-way audio, upgrade, etc., IP video input : 16-ch, Incoming bandwidth : 160 Mbps, Outgoing bandwidth : 160 Mbps, Audio output : 1-ch,RCA, Decoding format : .265/H.265 +/H.264/H.264 +/MPEG4, Synchronous playback : 16-ch, Capability :2-ch @ 8 MP (25fps), SATA : 2 SATA interfaces, Capacity : Up to 6 TB capacity for each HDD, Two-way audio : 1-ch, RCA (2.0 Vp-p, 1k), Network interface : 1, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface, USB interface : Frontpanel: 1 x USB 2.0; Rear panel: 1 x USB3.0 Alarm in/out : 4/1, model: HikvisionDS-7616NI-K2/similar, make: Hikvision/ CPPLUS/ similar, Inspection: Consignee. | — | — | — | 1,11,384 | |
| — | 12.00 | — | — | ||
| Supply of Professional Large Format Display, Size 138 cm Wi-FI Screen Share HotSpot Screen Brand: LG or NEC or Sony or Samsung or similar with 3 years onsite warranty and interfacing equipment for IPIS system at the station under installation | — | — | — | 7,18,680 | |
| — | 12.00 | — | — | ||
| Supply of 4TB Windows Surveillance Hard Disk, RAM Size: 4 GB, Memory Type: DDR3 SDRAM, Hard Drive Size: 4TB, Hard Drive Interface: Serial ATA, Rotational Speed:5400 RPM, Wattage: 5 Watts, Make:Toshiba/ WD/ Seagate. Inspection:Consignee. | — | — | — | 1,17,211.08 | |
| — | 10.00 | — | — | ||
| Installation, testing, commissioning of CCTV System & fixing of camera, at various locations as per instruction of site engineer | — | — | — | 64,001.5 | |
| — | 16.00 | — | — | ||
| Supply of Permanent Lubricated HDPE Telecom duct of size 50/42mm and accessories as per latest specification TEC GRNo.GR/TX/CDS-008/03/ March11 with latest amendment for OFC cable of size 24/6 fibre armoured in length of 1000 mtrs/roll. Duct to be supplied from TEC approved sources.(Inspection by Consignee) | — | — | — | 13,52,241.76 | |
| — | 16.00 | — | — | ||
| Laying of HDPE duct in trench and its protective work as per direction of site engineer. | — | — | — | 1,13,616.32 | |
| — | 180.00 | — | — | ||
| Supply of GI pipe, inner dia.100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA, JINDAL/ ZENITH BIRLA/similar make. (Inspection by Consignee) | — | — | — | 2,14,347.6 | |
| — | 180.00 | — | — | ||
| Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site. | — | — | — | 14,571 | |
| — | 8000.00 | — | — | ||
| Over head laying of 6-core OFC cable including clamping along the wall/fob structure as per instruction site engineer. | — | — | — | 4,70,320 | |
| — | 100.00 | — | — | ||
| Supply, Transporting and installation of concrete (RCC) route indicators at intervals of 50 meters as per technical specification. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations it shall be painted with RED colour. (Inspection by Consignee) | — | — | — | 1,44,622 | |
| — | 16.00 | — | — | ||
| Supply of Optic Fibre Cable 6 Core (Single mode) armoured, as per TEC Spec. TEC/GR/OFC02/03.Sep.2003 or latest, Make: Finoles cables/ Usha martin/ Sterlite/ Vindya Telelinks/ West coast/ Birla Cables/similar, Inspection: Consignee. | — | — | — | 7,28,236.96 | |
| — | 80.00 | — | — | ||
| Supply of 12 port LIU, 19 in chrack mountable as per following specification: a) It should have12 SP type ports for termination of SM optical fibres. b) It should be rack mountable with 1U height. c) It should be equipped with front managed saddle for jumper/patch cord management. d) It should have12 SC termination. e) It should be equipped with adequate nos. of splicing trays to splice 12fibres. f) It should have proper rubber grommet for cable protection and to minimize dust build up. g) It should be fully loaded with all the accessories for splicing and termination of fibres. h) It shall be of reputed make like D-Link or 3M or Digilink or Molex or similar make.(Inspection by Consignee) | — | — | — | 6,97,899.2 | |
| — | 80.00 | — | — | ||
| Installation & commissioning of 12 port LIU with all accessories and shall be used for terminations of optical fibers into the splice trays supplied with it, it shall be installed inside the 19 inch rack using all required fixing/ installation material like nuts, bolts, screws and cable ties etc. asper requirement. The splice trays shall be placed and secured into the LIU after splicing. The SC terminations shall be fixed and secured after splicing of the pigtails into the LIU. It shall be ensured that the movement of the trays is easy and free of any obstructions. | — | — | — | 1,02,899.2 | |
| — | 320.00 | — | — | ||
| Supply of optic fiber pigtails for termination of OFC cables with following specification: a) It shall be single mode SC/SC type with push pull mechanism or as per site requirement and fully compliance with latest industry standard. b) It shall have length of 2 Meters at least. c) It shall have SC connector at one end and other shall be loose for splicing. d) It should be of reputed make D-Link or 3M or Digilink or Molex/similar.(Inspection by Consignee) | — | — | — | 1,76,342.4 | |
| — | 480.00 | — | — | ||
| Splicing/ dropping/termination of each fiber/ pigtail in LIU/IO box/ terminal joint through fusion splicing for termination of OFC cables. The fibers terminated shall be tested and test report (hard copy and soft copy) shall be submitted to the Railways site in-charge for records. each fiber shall be properly marked with necessary ferrules/tags, as per following specification: i) The optical fibre cables shall be entered in to the rack through cable entry and using the cable guides. ii) The loosened ends of the fibres and pigtails shall be properly prepared for termination in to the already fixed LIU. iii) Each of the fibre shall be spliced with a pigtail by the method of fusion splicing using a Fusion Splicing Machine of standard reputed make. The splicing shall be done carefully by a skillful person. iv) The splices shall be carefully placed and well secured in the splice trays of the LIU. v) Each fiber /pigtail shall be properly marked with necessary ferrules/ tags.vi) The extra length of the fibers / pigtails shall be coiled and placed and secured with cable ties. vii) The optical connectors of the pigtails shall be placed into the patch panel as per the numbering of fibers. viii) All of the terminated fibers shall be tested with OTDR and test report (Hard copy and Soft copy) shall be submitted to the Railways site In-charge for records. | — | — | — | 88,372.8 | |
| — | 10.00 | — | — | ||
| Maintenance free earth as per RDSO/SPN/197/2008 or latest consisting of: (1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min 250 micron & UL listed & marked-01 No. (2) Earth Enhance compound RDSO approved in sealed bag of 10Kg-03 Nos. (3) Copper strip 150 x 25 x 6 mm-02 Nos. (4) Copper strip 300 x 25 x 6 mm-01 No. (5) 35 Sqmm copper cable to connect earth electrode to MEEB-15 Mtr. approximately. (Inspection by RDSO) | — | — | — | 2,05,770.1 | |
| — | 10.00 | — | — | ||
| Installation of unit earth as per RDSO/SPN/197/Ver 1 or latest, to construct earthing of </= 1Ohm consisting of: a) Digging the earth to required depth, insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the equipment room, exothermic weld material and tools & fixtures for the welding copper tapes and electrodes etc. shall be arranged by the contractor. | — | — | — | 61,203.9 | |
| — | 10.00 | — | — | ||
| Supply & Installation of Router with all accessories (Technical specification as per attached annexure-A). Inspection: Consignee | — | — | — | 14,56,299.5 | |
| — | 5.00 | — | — | ||
| Excavation of trench in all kinds of soil (1.0mtr. Depth 300 mm width) and refilling of the trench without Bricks and final back filling, ramming and consolidation of soil as well as the disposal of the soil, if any. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately. Note: Payment will be made as per actual work done on pro-rata basis ,if the required depth is not available at site. If the depth of trench is not uniform in as pan of 100 mtr. of shorter lengths along the cable run, minimum depth will be taken for that particular stretch for payment. Prior permission should be taken before laying of cable if the depth of trenching is less than 1.0 Mtr. Inspection: Consignee. | — | — | — | 5,84,170.05 | |
| — | 240.00 | — | — | ||
| Boring under Metalled Road/Railway track for crossing of Telecom cables. Boring to be done for crossing road/rail at 1.5 mtr depth & after boring min. 2/4" dia G.I pipes are to be inserted & cable to be laid through the pipes | — | — | — | 1,42,248 | |
| — | 72.00 | — | — | ||
| Cutting of all types of Roads/ platforms preparatory to trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site. | — | — | — | 2,42,949.6 | |
| — | 81.00 | — | — | ||
| Where ever depth of 0.5 m cable trench is not feasible cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. | — | — | — | 4,53,943.44 | |
| — | 12.00 | — | — | ||
| Supply of High throughput LAN extenders as per RDSO specification. (Inspection by Consignee) | — | — | — | 3,24,227.88 | |
| — | 80.00 | — | — | ||
| Supply & installation of independant iron (galvanised) structure post (100 mm) of min. 15 feet in length including water proof protecting arrangement with canopy for cctv including painting & erection. Inspection: Consignee | — | — | — | 3,14,004.8 | |
| — | 1.00 | Lumpsum 499000.00 | — | ||
| Provision of application software for Android and iOS devices to monitor the operation of these GS services round the clock with necessary client licence of 100 user for operational life of the CCTV system. | — | — | — | 4,99,000 | |
| — | 20.00 | — | — | ||
| "Supply, Installation, Testing & commissioning of Full HD Resolution PTZ (Pan, Tilt, Zoom) IP Colour Camera with varifocal lenses along with housing and mount with all accessories as per RDSO specification No.RDSO/SPN/TC/65/2021 Version 6.0 or latest. Inspection by RDSO. " | — | — | — | 13,37,648 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TENDERDOCSFORCCTVINGOODSSHED08.04.2026.pdf SUR TENDER DOC FOR CCTV
ATTACHMENT
GCC-April2022_merged20.05.2024.pdf
ATTACHMENT
TENDERDOCSFORCCTVINGOODSSHED08.04.2026.pdf
ATTACHMENT
GCCACS1113032026.pdf
ATTACHMENT
GCC-2022-uptoACS10_2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .