Tender Value
₹6.6 L
EMD Value
₹13,140
Closing Date
25 Mar 2025, 5:00 pmClosed
Smt Priyanka Saini
Municipal Corporation Karnal
Providing and fixing of 2 nos of 12.5 mtr. Long High Masts with energy efficient LED flood light erected at Ambedkar Bhawan and Kashap Chaupal of ward no. 3 area under Municipal Corporation, Karnal. (Recall)
2025_HRY_434568_1
202560719560 847E 4C6F B646 593953E1BA67747ULB
Open Tender
Civil Works
Works
30 days
Karnal
2 documents required · 2 mandatory
₹1,000
₹13,140
Yes
2 May 2025
18 Mar 2025
26 Mar 2025
18 Mar 2025
25 Mar 2025
18 Mar 2025
Amount
Supply of Aluminium cable make should be as equivalent grade as capable for 650/1100V, XLPE Insulated, cores laid up, PVC tape,inner sheathed for Multicore Cables Make should be as equivalent grade of havells, RR Kabel, polycab,grandley etc. make Approved by PWD/ DULB and as per directions given by Engineer-in-charge, complete in all respects 10 Sq. mm 4 Core Cable (Arm)
Supply and erection of Digital Time switch with current carring capacity upto 16A and capable for the range for 110-240 VAC, make should be as equivalent grade of havells, LandT, INDO-ASIAN, SIEMENS,HPL etcApproved by PWD/ DULB and as per directions given by Engineer-in-charge, complete in all respects .
Supply and erection of power Contactor (40 Amp.) with low VA burdon coil completely shield for dusty atmosphere should be capable for 16A to 60A range. Make should be as equivalent grade of havells, LandT, INDO-ASIAN, SIEMENS, HPL etc. Approved by PWD/ DULB and as per directions given by Engineer-in-charge, complete in all respects
`200 watt Flood light:- Supply of LED-based flood light and it must possess the following minimum specifications:- 1.The 05 years warranty will be given by the Manufacturer/Brand area Manager in written. Only then, LED light will be acceptable. 2. LED light fittings of make Havells, Crompton, H.P.L, Polycab, Bajaj, Surya Approved by PWD/ DULB and as per directions given by Engineer-in-charge, complete in all respects ` {1 Input voltage:- 90-270 V, AC standard with cut off at 300v with automatic on provision. for protection from surge high voltage, the provision of auto shutdown should be provided. 2 Input Frequency:- Input Frequency =50 Hz plus 3% 3 Power factor :- ()0.95) 4 Working Humidity:-10% to 90% RH 5 Working temperature:- -10°C to ( plus ) 50°C) 6 Luminary efficiency:- =100 lumen/watt as per LM79 data from certified third-party testing facilities like NABL-approved lab/UL Lab. 7 Optics-Lens Material/Make of lens:- High impact polycarbonate (PMMA)/Cathode, Ledlink, Ledil. 8 Luminary Housing:- power pressure die-cast aluminium housing with ADC 12 Or LM6 alloy and toughened glass cover. 9 Screws, Fasteners and Clamping material:- Stainless steel Grade – 304. 10 Surge / Spike Protection:- 4 KV (internal) and 10 KV using external certified surge protector. 11 Make of LED:- Lumileds/Cree/Osram /Nichea /Samsung/Seoul or any other equivalent. 12 Color Temperature:- 5500-6500K 13 Color rendering index:- = 70 14 Life expectancy of the project (LEDs):- Minimum 50000 hrs. with minimum 70% lumen output L70 data to be produced for LEDs and LM79 for Luminaries. 15 LED Printed Circuit Board:- Metal Core Printed Circuit Board. Thermal Conductivity = 2W/MK 16 Class of Power Supply:- Class II, LVLE input output isolations (Max 100 VA output) 17 THD:- = 10% 18 Uplight:- Zero Uplight as per LM79 report from NABL/Lighting Facts/accredited third-party testing facility. 19 Photometry:- LM79 Report from NABL/Lighting Facts accredited lab for all variants. 20 Lumen depreciation (L-70) :- = 50,000 hours (as per TM21 using L80 data and INSITU data by LED manufacture LM 80 report). 21 Ingress Protection:- IP66 as per IEC 60598/IEC 60529 from NABL accredited lab for all LED. 22 Conducted Emission and Radiation:- Emission test report from NABL accredited lab conforming limits complying with IEC 61000. 23 Driver Test:- As per BIS 24 Wattage Variation:- ±10% 25 Wattage of LED:- 1-3 watt 26 Pole entry dia:- It should be suitable for mounting 30 to 56mm outer diameter poles with locking bolts. It should provide a complete bracket with a locking bolt. 27 LED drive current:- (1000mA 28 Beam angle:- 80° / 135° with lens 29 Safety Test:- As per IEC 61347 – 2 - 13 30 LED light fittings as per list approved by the DULB/PWD Department 31 LED light fitting will provide an on-site Guarantee/Warranty certificate applicable for a minimum of five(5) years from the date of commissioning of LED light fitting from the company in writing. }
Bidder Name
Amount
M/S J.B.R. Electrical Company (GSTN-NA) BID ID -1230455
MS Tiger Solar Light Trading Co. (GSTN-NA) BID ID -1230395
SITA RAM ENTERPRISES (GSTN-NA) BID ID -1228254
UNIVERSAL ENTERPRISES (GSTN-NA) BID ID -1230200
SITA RAM ENTERPRISES (BID ID -1228254)
M/S J.B.R. Electrical Company (BID ID -1230455)
MS Tiger Solar Light Trading Co. (BID ID -1230395)
M/S J.B.R. Electrical Company (BID ID -1230455)
MS Tiger Solar Light Trading Co. (BID ID -1230395)
SITA RAM ENTERPRISES (BID ID -1228254)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .