Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC BEING A LOWEST BIDDER | |
| 2 | L2₹16.8 L+₹27,401.25 (1.66%)Rejected-Finance | L2 | Rejected-Finance Not being a lowest bidder | |
| 3 | L3₹17.0 L+₹49,257 (2.98%)Rejected-Finance | L3 | Rejected-Finance Not being a lowest bidder | |
| 4 | L4₹17.2 L+₹69,383 (4.19%)Rejected-Finance | L4 | Rejected-Finance Not being a lowest bidder | |
| 5 | L5₹19.0 L+₹2.4 L (14.7%)Rejected-Finance | L5 | Rejected-Finance Not being a lowest bidder |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
25 Aug 2021, 6:00 pmClosed
GE 861 EWS
GE 861 EWS PIN-913861 C/o 56 APO
PROVN OF GENERATOR SHED WITH HARD STANDING AND CERTAIN OTHER SANCTIONED WORKS AT AWANTIPUR GRN UNDER GE 861 EWS
2021_MES_464062_1
GE 861 EWS-33/2021-2022
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
As per NIT
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹45,000
Yes
1 Oct 2021
30 Jul 2021
27 Aug 2021
30 Jul 2021
25 Aug 2021
13 Aug 2021
Amount
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc nexc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Demolition of cement concrete (unreinforced in ground floors & pavings n.exc 15 cm thick (below or above ground level), complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25cm in depth complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
M & L for precast cement concrete block masonry type B-1 (1:3:6) 20mm graded aggregate with hollow blocks exc 10cm in width set in CM 1:6, complete all as specified as directed by Engr-in- Charge
M&L Rendering 10 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L Rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L preparation of new plaster surface of walls and applying two coat of cement base paint over a coat of alkali resistance primer complete all as specified and directed.
M&L preparation of newly plaster surface and applying two coat of distemper oil emulsion white tinted over a coat of primer complete all as specified and directed by Engr -in - charge.
S&F Aluminium powder coated door shutter side hung type on pivots alongwith hydraulic door closer with style rails ( Top, bottom & lock rail) top rails meeting style, lock rail size 48x44mm, top & bottom rail size 108x44mm, frame for chowkats size 40x63mm including door lock , handles 5mm thick plain glass in top and 12mm thick prelaminated particle baord (both side laminated) in bottom panel including necessary jointing cleat, glazing clips, rubber packing, snap beading, screws of suitable size etc (thickness of aluminium section shall not be less than 1.5mm), complete all as specified and directed.
S&F three track aluminium sliding window with two or more shutter with 4mm thick tinted glass plain/black and one shutter using aluminium wire cloth 0.36mm nominal dia & 1.18mm width aperture for mosquito proofing with good quality bearing handle, lock, rubber beading and glazing clips etc using following aluminium powder coated section conforming to size for frame 95mmx45mm, trak size 92mmx32mm, shutter section 43mmx18mm (thickness of aluminium section shall not be less than 1.5mm), complete all as specified and directed.
S&F Aluminium partition with powder coated aluminium tube of section 114mmx44mmx1.5mm thick at bottom and remaining vertical and horizontal sections 44.5mmx45mmx2mm thick with aluminium clips ,rubber beading ,aluminium nuts bolts etc including 5.5mm thick plain/black glass and 12mm thick prelaminated particle baord (both side laminated) spacing of glazed aluminium tube in horizontal 75cm max and vertical 90cm max complete all as specified and directed.
M&L 75mm thick PCC 1:2:4 Type B-2 (40 mm graded stone aggregate) as in floor finished even and smooth without using extra cement complete including 3mm thick 38mm wide glass dividing strips complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
M&L rolled mild steel as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St.-240, complete all as specified and directed.
S&F rolled mild steel as in roof trusses Fe 410-W(Gde-E- 250) quality-A (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel, or flat sec) incl distance pieces cleats etc complete all as specified and directed.
M&L preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M&L for treating ends of posts,backs of chowkats,etc.with tar or coal tar black paint ,area tarred exceeding 0.10 sqm but not exc 0.50 sqm each, complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Hardcore of broken stone or boulder of gauge n exc 63 mm , deposited, spread and levelled in layers n. exc 15 cm thick, watered and rolled/ rammed to a true surface complete all as specifid and directed.
M&L 100 mm thick PCC 1:3:6 type C-2, (using 40 mm graded aggregate ) as on sub base of floor and paving, complete all as specified and directed.
M&L coloured Machine pressed precast concrete interlocking paver block with grey cement and pigment, any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, laid over and including 50mm thick sand cushion and compacted with mechanical vibrator, complete all as specified and directed.
M&L PCC 1:3:6 type C-1(20 mm gardded aggregate) as in copings including necessary form work complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering and removing surplus soil to a distance n exc 50 m and making good surface all as specified.
S&F of 0.63mm thickness galvanised corrugated mild steel sheeting with two corrugations side lap fixed with L type or J type or cranked hook bolts in roofs, walls etc.with grade of Zinc coating 275 complete all as specified and directed.
S&F plain galvanised 0.80 mm thick mild steel sheeting in ridges,hips,valley gutters,drips and straight flashing,length and of zinc coating of grade 275 complete all as specified.
Material and labour for two coats of synthetic enamel paint on new untreated CGI / PGI sheet surface over a coat primer including preparation with mordant solution all as specified.
M&L 25mm thick Plain cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in flooring all as specified and as directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
Chequered coloured cement concrete tiles of size 300 x 300 x 25 mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L 2nd class hard wood, plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints.
M&L 30mm thick second class hard wood (Sal/ Hollock) factory made glazed and skeleton shutters, divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of sash bars and framing moulded, and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b); supplied and fitted to chowkhats, complete all as specified and as directed.
M&L 75 mm long, mild steel cold rolled Butt hinges, medium weight, complete all as specified and directed.
M&L 75mm long, aluminium alloy handles, cast type, anodised, all as specified and directed.
M&L100mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
M&L stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm & fixed with stainless steel wire staples, complete all as specified and directed.
M&L 2nd class hard wood clean swan plain fillets square/rectangular or triangular in section of sectional area exc 13 sqcm but n exc 25 sqm secured with nail or brads complete all as specified and directed.
M&L 2nd class soft wood fillets of sectional area exc 3 sqcm but n exc 6 sqcm bull nosed, splayed, chamfered or rounded on one edge or face secured with nail or brads complete all as specified and directed.
M&L 2nd class soft wood fillets of sectional area n exc 3 sqcm but bull nosed, splayed, chamfered or rounded on one edge or face complete all as specified and directed.
M&L 6 mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in ceiling flat and sloping with nails to timber frame complete all as specified and directed
M&L 6 mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in wall with nails to timber frame complete all as specified and directed
M&L 2nd class soft wood as in scantlings and similar work, clean sawn, timber framed and fixed in position, complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box all as directed by Engr in Charge & 3mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per srl item No-47 here in above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed.
All as per srl item No-47 here in above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
All as per srl item No-47 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead complete all as specified and directed.
M&L for Switch piano flush button single pole one way 5/6 amps 240 volts, complete all as specified and directed.
M&L for Switch Socket combination outlet 5 Amps 5 pin flush type, 230 volts, complete all as specified and directed.
M&L for Switch Socket combination, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts, complete all as specified and directed.
Supply and fixing fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required at site or directed by engineer-in-charge.
S & F Lamp holder angular/straight insulated body with back plate for batten fittings complete all as specified and directed.
S&F decorative ultra slim linear LED in replacement of 18 Watt , 4 ' long warm colour lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack incl LED tube complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable with suitable size LED tube all as specified and directed by EIC. Make : Havells Cat Part No LHDD02102674 or Equivalent/C&S/Bajaj.
Supply and fixing LED bulk head fitting 9 W in engineering plastic housing with clear prismatic diffuser, including LED lamp and all accessories for fixing on wall all as specified and directed.
S & F ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
Sheet metal enclosures distribution board, single pole and neutral 8 way with 200 Amps rated bus bar 240 V, double door IP-42 protection, fixed on wall duly groted in solid block wall or n wooden board with electrical connection and making good distributed wall surfaces to match with existing specification, complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, testing and commissioning, complete all as specified & directed.
MCB, DP (Double Pole), AC, 240 volts, "B" series capacity 20 Amps to 32 Amps 10kA and making connections, testing and commissioning, complete all as specified & directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by 25%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Fixing only exhaust fan 230mm to 250mm sweep PVC body with louvers, 240 volts AC single phase, 50 Hz, ISI marked, including necessary work in wall/sheet, including connection cable of suitable size, nut bolt and other fixing material complete all as specified and directed.Note :- Item will be issued under Sch 'B' free for fixing.
Supply and fixing LED lamp 10W, 240V, complete all as specified and directed by Egnr-in-Charge.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 Sqmm nominal cross section 2 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
M&L Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified.
M&L Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified.
Supply , laying and fixing 40mm bore galvanised steel mild steel tubes with all fittimgs ,light grade laid in trenches for cable protection complete all as specified.
M/S STARE BUILDERS
M/S U.K. ENTERPRISES
JANDOO AND CO.
M/s Jamsheed Ahmad Dar
NAJAR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .