Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹7.6 L+₹55,338.30 (7.84%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹7.7 L+₹68,476.20 (9.70%)Rejected-Finance 544 STREET NO 10 GHUMMAN NAGAR PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.1 L+₹1.1 L (15.1%)Rejected-Finance 6 C SHEKHAWAT COLONY SIRSI ROAD MEENAWALA JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | 302012 | L4 | Rejected-Finance Being L4 |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
10 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender document
2020_MES_395730_1
GE(S)/PAT-47/S/2020-21
Open Tender
Civil Works
Item Rate
150 days
Mil Stn Nabha
refer tender document
6 documents required · 6 mandatory
₹500
Yes
GE (South) Patiala
₹18,000
Yes
30 Dec 2020
17 Nov 2020
12 Dec 2020
17 Nov 2020
10 Dec 2020
24 Nov 2020
17 Nov 2020 - 23 Nov 2020
60 days
Amount
Taking down cement plaster on walls built in cement mortar etc including racking out joints, hacking for key. Scrubbing down with water etc, complete all as specified and directed.
Demolition of brick work built in cement mortar, complete all as specified and directed.
M&L for brick work in cement mortar (1:6) using sub class 'B' bricks staight or curved on plan exc 6.0 m mean raidus, complete all as specified and directed.
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished fair and even without using extra cement complete all as specified and directed Note : Water proofing compound shall be measured and paid saparately.
M&L 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Complete removal of existing treatment of any type/description such as distempering work ,internal emulsion etc from internal/external surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed.
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits(thickness vary from 1.5to2.5mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall careputty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed.
Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceiling surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.
Applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed.
Supply only integral water proofing compound ISI marked.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame, complete all as specified and directed.
All as per srl item No 11 hereinbefore but n. exc 1.5 sqm each, complete all as specified and directed.
S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 125x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified. ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item )
S&F factory made flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides with veneer with 6mm thick lipping frame to match, complete all as specified and fixing following items : (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 4 nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf (d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x250/300 mm - 1 nos per leaf (e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos per leaf (Note:- Steel Mongery shall be paid as supply only against respective item.)
S&F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-1 section 8 clause 8.20(a), kiln seasoned and chemically pressure treated and fixing following items, complete all as specified and direceted. (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 4 nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf (d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x300mm - 1 nos per leaf (e) 200 mm long MS rat tail pattern spring hinge including roller and roller plate - 01 No per leaf. (Note:- Steel Mongery shall be paid as supply only against respective item.)
Factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges,handle tower bolts,lugs etc all as shown on drawing noTD-219(c) sheet 1/3 to 3/3 and TD-220 (c) sheet 1/3 to 3/3 as applicable, complete all as specified and directed. Note;- (i)for the purpose of measurement& payment double shuttre with frame shall be considered as one unit. (ii) Glaging , wire mesh and glass,shall be measured and paid for separately
Sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
S & F in repair Wire netting of galvanised steel wire 1.40mm dia and size of mesh 25mm fixed with tinned tacks of wire staples
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed.
M&L for vitrified ceramic 10mm floor tiles of minimum size 600X600 mm 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid over complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates for base of flooring in complete all as specified and directed.
Coloured glazed ceramic tiles (300 x 600 mm) x 7mm or (450X350 mm)X7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:4), complete all as specified and directed.
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws, complete all as specified and directed.
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws, complete all as specified and directed.
M&L for squar hollow sections as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165), complete all as specified and directed.
S&F mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed.
Dismantling of wrought timber truss scantling 40Sq.cm and over in section framed work, provided for, complete all as specified and directed.
Dismantling of wrought timber scantling as in fillets, post rafter , purlins etc under 40Sq.cm in section framed work, provided for, complete all as specified and directed.
M& L for Preparation new steel surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide as in primer all as specified and directed.
Hard core of broken bricks of gauge n exc. 63 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface, complete all as specified and directed.
PCC (1:3:6), 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement, complete all as specified and directed.
Machine pressed rubber moulded precast concrete inter locking paver block any shape and size made of M-35 grade concrete (with grey cement and no pigment) of 60mm thickness with 6mm top layer of anti abrasive material laid over 25mm thick (compacted) fine sieved sand complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed.
M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sectiopns of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 12 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed.
Supply only Stainless Steel (304 Grade) Finished Butt Hinges 150mm, complete all as specified.
Supply only Stainless Steel (304 Grade) Finished Tower Bolt 200mm long, complete all as specifed.
Supply only Stainless Steel (304 Grade) Finished Handles 200 mm, complete all as specifed.
Supply only Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x250/300 mm, complete all as specifed.
Supply only Stainless Steel (304 Grade) Finished Floor Door Stooper, complete all as specifed.
Supply only 200 mm long MS rat tail pattern spring hinge including roller and roller plate, complete all as specified.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.iii) Neccessary cutting chasing wherever required and making good the disturbed surface as per existing shall be part of job at no extra cost.
All as per item No 45 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 45 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for Modular switch 1 way 6A, 1 module, complete all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module type , complete all as specified and directed.
M&L for Modular Socket, 6A - 5 pin 2 module type, complete all as specified and directed.
M&L for Modular Socket 6A/16A - 2/3 pin 2 module type , complete all as specified and directed.
Supply & fix in replacement of existing unserviceable FTL with new techonlgy ultra bright led tubelight with aluminium heat sink & polycarbonate diffuser having high efficacy suited for installation in existing t5 tubelight with G5 lamp holders to give glare free light with separate led driver of capacity 18W 865 1148mm LED including neccessary electric conection with batten, complete all as specified and directed.
Supply & fix in replacement of existing unserviceable batten with BOX TYPE Pre-coated CRCA body, heavy duty regaL Batten for LED tube universal batten for G13 t8 lamps including neccesary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface, complete all as specified and directed.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 18 watts for batten fitting, complete all as specified.
Supply and fix LED Lamp LED new Adore 7W E27 WW Ball Lamp LHLDERHEMD 8X007 9 watt , complete all as specified and directed.
Supply and replace environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit led luminaire comprising of high brightness leds of capacity10 Watt , complete all as specified and directed.
M&L for replacement of existing UNSV earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I , complete all as specified and directed.
M & L for Fan step regulator, 120W - 1 module, complete all as specified and directed.
Excavation in trenches soft/loose soil n.exc 1.5mtr wide and n.exc 1.5mtr deep for laying of cable and getting out complete all as specified including taking out defective existing cable of any type of size, complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exceeding 25cm each in soft/loose soil complete all as directed by Engr-in-Charge.
Removing surplus spoil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as directed by Engr-in-Charge
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable completed all as specified and directed.NOTE: For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I, complete all as specified and directed.
Sub class ‘B’ old size bricks laid adjacent to each other perpendicular to the direction of cable in trenches for protection of cable , complete all as specified and directed.
Cutting channels,grooves or rebates excavation 15 cm but not exceeding 30 cm on unreinforced surface for laying of pipe and make disturbed suface good after laying of pipe complete all as specified and directed.
S& laying GI pipe Light grade 50 mm passing through cables, walls , across the roads with proper clamps, nut & bolts including taking down complete all as specefied and dirceted.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system complete all as directed. Note: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar, complete all as specified and directed. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The DB shall be fiush fixed and making good the disturbed surface shall be part of job at no extra cost.
S&F sheet metal enclosures distribution boards,vertical type double door three phase 415 volts 4 ways MCCB,ISOLATOR&MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a)MCCB FOUR POLE 200 AMPS AC 415 VOLTS 16 KA IHLGNF0063 =01 NO as incoming Note :- (i) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost. (ii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. (iii) all the vacant holes of the DB shall be provided with blank plates of appropriate size.
Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Supply & laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of crosssectional area 35 Sqmm 3 & 1/2 Core all as specified & directed by Engr-in-Charge.
Taking down fan, sealing cable end, dismantling blades and removing fan and deposite the store, complete all as specified and directed.
Hanging only ceiling fan retrieved against item no-74 and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
Supply and fixing in repairs 1100 volts grade heavy duty cable PVC insulated aluminium conductor 10 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twine core cable flat or circular, complete all as specified and directed.
Supply & Fixing in repair with new tecnology LED energy saving LED street light with PDC aluminium body and toughned glass visor fitted in frame. secondary optical lense for superior light distribution . Efficency > 100 lumens/watt & IP66 protection level of 25 Watt capacity including GI bkt of 40 mm bore 1.5 mtr long bent to shape and making neccessry connection with service cable as directed by Engr-in- Charge.
R D Bansal
FAVOURITE ENGINEERS
m/s k.k. construction co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .