RequiredExperience with Government
RequiredAnnual Turnover
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled Yes Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Dental Autoclave With Accessories ( 198 pieces ) Technical Specifications 1/8 * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Performance Parameters Purpose Autoclaving of equipments
Requiredinstrument etc for dental treatment Autoclaving of equipments
Requiredinstrument etc for dental treatment Scope of Supply Auto clave
Requiredservo stabilizer
Requiredwater tank and sterilizatinon pouches Auto clave
Requiredservo stabilizer
Requiredwater tank and sterilizatinon pouches Type of Loading Front Front Type of auto clave Table Top Table Top No of separators to hold different types of instruments materials 3 3 Sterilization Process Automatic Automatic Drying process Automatic Automatic Control management and monotoring Completely microprocessor controlled
Requiredconstant management and monitoring of autoclave functions and parameters * Range of Capacity of autoclave in liters(Hint Seller to select the option based on capacity of auto clave offered) 17-19 17-19
Required20-22 Provision of Pre vaccum cycles to remove air from the chamber Yes * Class type B B Provision of pre vaccum cycles to remove air from the chamber Yes * Provision of Dry cycle option with selectable time periods Yes * Type of display with soft touch pad LED LED Material of construction of the perforated trays Anodized aluminum Anodized aluminum 2/8 Porosity of microbacterial filter 0.3 micron 0.3 micron Location of Antimicrobial filter The microbacterail filter is located inside the autoclave undermeath autoclave to prevent dust from going inside the autoclave The microbacterail filter is located inside the autoclave undermeath autoclave to prevent dust from going inside the autoclave Weight of the autoclave in KG 45 * Availability of Alpha numeric display to set protocol with soft key pad Yes * Number of error messages and warning systems available more than 30 more than 30 Table top auto clave has different pre program cycles of autoclaving different wrapped and unwrapped equipment/materials ie metal solid instruments
Requiredhollow metal instruments
Requiredrubber
Requiredplastic
Requiredtextile Yes * Type of monitoring systems available with the Autoclave Constant monitoring of temperature
Requiredpressure
Requiredvacuum and drying cycle * sterilization holding time for short load over 3 minutes and less than or equal to 4 Minutes over 3 minutes and less than or equal to 4 Minutes No of preprogrammed autoclaving cycles available 5 5 Availability of Prion Program Yes Yes sterilization holding time for prion programme in minutes 17-20 17-20 Door opening and closure indication Digital display Digital display 3/8 Availability of saftey valve to release excess pressure to prevent accident Yes * Table top autoclave have automatic pressure locking system while sterilization to prevent accidental door opening Yes * Power supply Supply voltage range 220-240 Volts
Required50/60 Hz
Requiredsingle phase * Accessories Facility to print temperature
RequiredPressure
Requiredtime and date of cycle yes yes The item shall be supplied with an inbuilt water tank with automatic water level sensors Yes Yes There shall be provision to add water to chamber automatically when required Yes * Thermal Printer Provided with Autoclave Yes Yes Availability of RS 232 Port for connecting Thermal printer Yes * Servo stabiliser (atleast 3 KvA)
Requiredprovided either inbuilt or separate Yes Yes Number of sterilzation pouches of 10 cm width
Requiredmade of paper and polypropylene
Requiredwith thermal chemical indicator provided 1000 1000 compatible distilled water plant manufactured by the same OEM Yes Yes
RequiredNo Certifications Product/model Certification European CE European CE 4/8 Conformity to 93/42/CEE- Medical device directive Yes Yes Conformity to 97/23/CEE- Pressure equipment directive Yes Yes Conformity to 2002/96/CEE- Waste electrical and electronic equipment(WEEE) Yes Yes Conformity to IEC 61010-2-040- Safety requirement for electrical equipment for measurement control and laboratory use Yes Yes Technical demonstration and training to be arranged at buyer's premises after delivery before acceptance Yes Yes OEM and supplier certificate that equipment is original and new and not a refurbished reconditioned product to be provided at time of supplies Yes Yes Guarantee & Warranty in years 5 5 Comprehensive Maintanance service(CMC) included after the offered warranty period Not included Not included The equipment might be required to be installed at remote/field location and OEM authorised service centres will provide prompt Installation
Requireduser training
Requiredservice on-site as and when required Yes Yes 5/8 * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents