| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.9 LAccepted-Finance 10 2 NARAYAN BAG INDORE M P | ₹37.9 L | L-1 | Accepted-Finance Lowest Rates after Schedule of Credit Rs. 92612.50 |
| 2 | L-2₹39.7 L+₹1.7 L (4.60%)Rejected-Finance | ₹39.7 L+₹1.7 L (4.60%) | L-2 | Rejected-Finance High Rates |
| 3 | L-3₹41.3 L+₹3.4 L (8.92%)Rejected-Finance | ₹41.3 L+₹3.4 L (8.92%) | L-3 | Rejected-Finance High Rates |
| 4 | L-4₹44.1 L+₹6.2 L (16.3%)Rejected-Finance | ₹44.1 L+₹6.2 L (16.3%) | L-4 | Rejected-Finance High Rates |
| 5 | L-5₹44.8 L+₹6.8 L (18.1%)Rejected-Finance | ₹44.8 L+₹6.8 L (18.1%) | L-5 | Rejected-Finance High Rates |
| Sl No | Description | Qty | Unit | Vinayak Trading House L5 | S.S. Engineers L1 | Ms Kailash Chandra Babulal L4 | m/s rudraksh enterprises L6 | ALLAHABAD ENTERPRISES L3 | SAHYOG ELECTRIC L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in repair of LED street light Luminaies 90 watt wih IP 66 rating. LEDs shall have optical grade polycarbonate/PMMA lens to provide street light distribution. The fixture should be made of pressure die cast Aluminium/ Aluminium Extrusion and clear flat glass. The housing should be with manufacturer's name embossing permanent mark on the die cast housing (Stickering/ screen printing is not acceptable). Control gear shall be provided with die cast aluminum cover for safety. Short Circuit protection should be such that it recovers automatically after fault condition is removed. Integral control gear, IK 08 or above. The fixture should have lumen maintenance of at least 70% at 50000 burning hours at ambient temp of 35 degree C. The driving current for LED should be Max 1A ±10 % . CCT should be 5700 K (+-300K). The efficacy of fixture should be at least 130 lumens/ watt. The power factor of driver should be > 0.95 and the THD < 10% & Internal surge Protection should be 4Kv internal and 10kv external surge protection should be atleast 10Kv for better saftey of fixture where CRI > 70%. The Fixture should be complete with LED Driver and all other accessories.Fixture should have discrete LED type and not Chip on board for better heat managment system and long life of LED. Vendor should provide third party NABL for LM 79, LM 80 Report of LED street light luminaire. Own lab certificate calming third party won’t be accepted. (reports should not be older than 6 months from the date of tender). Other certificates like ROHS certificate, REACH certificate, Photo biological test report & ISO certification for vendor will be needed. Manufacturer to have his own R&D lab for testing & should be approved from ministry of science government of India. The Lighting Fixtures should be supplied with 5 years Warranty against any manufacturing defect and warranty certificate shall be provided to the department through the OEM. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable complete all as specified and directed. | 80 | Each | 4,290 ₹3,43,200 | 3,876 ₹3,10,080 | 3,500 ₹2,80,000 | 3,700 ₹2,96,000 | 3,800 ₹3,04,000 | 3,400 ₹2,72,000 Lowest |
| 2.00 | All as per Srl item No. 1.00 above but capacity 120 Watts complete all as specified and directed. | 70 | Each | 5,400 ₹3,78,000 | 4,361 ₹3,05,270 | 4,200 ₹2,94,000 | 5,400 ₹3,78,000 | 4,200 ₹2,94,000 | 3,800 ₹2,66,000 Lowest |
| 3.00 | S&F in repair of LED Flood light Luminaires of Wattage 200watt with IP 66 rating. LEDs shall have optical grade polycarbonate/ PMMA lens to provide street light distribution. The fixture should be made of pressure die cast Aluminium having heat sink in Aluminium Extrusion and clear flat glass. The housing should be with manufacturer's name embossing permanent mark on the die cast housing (Stickering/ screen printing is not acceptable). Control gear shall be provided with die cast aluminum cover for safety. Short Circuit protection should be such that it recovers automatically after fault condition is removed. Integral control gear, IK 07 or above. The fixture should have lumen maintenance of at least 70% at 50000 burning hours at ambient temp of 35 degree C. The driving current for LED should be Max 1A ±10 %. CCT should be 5700 K (+-300K). The efficacy of fixture should be at least 120 lumens/ watt. The power factor of driver should be > 0.9 and the THD < 10% & Internal surge Protection should be 4Kv with external surge protection should be atleast 10Kv for better saftey of fixture where CRI > 70%. The Fixture should be complete with LED Driver and all other accessories. Fixture should have discret LED type and not Chip on board for better heat managment system and long life of LED. Own lab certificate calming third party won’t be accepted. Manufacturer to have his own R&D lab for testing & should be approved from ministry of science government of India. vendor should provide third party NABL LM 79 & LM 80. The Lighting Fixtures should be supplied with 3 years Warranty against any manufacturing defect and warranty certificate shall be provided to the department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable, complete all as specified and directed. All certificates required before supply of material. | 50 | Each | 7,900 ₹3,95,000 | 7,676 ₹3,83,800 | 7,000 ₹3,50,000 | 7,800 ₹3,90,000 | 7,200 ₹3,60,000 | 4,300 ₹2,15,000 Lowest |
| 4.00 | All as per Srl item No. 3.00 above but 150 Watt complete all as specified and directed. | 40 | Each | 5,520 ₹2,20,800 | 6,308 ₹2,52,320 | 6,500 ₹2,60,000 | 6,950 ₹2,78,000 | 5,500 ₹2,20,000 | 4,150 ₹1,66,000 Lowest |
| 5.00 | S&F of landscape lighting decorative poles jet black painted galvanized with gold colorpainted decorative rings embelishment of aluminium pdc including landscape LED luminaries of 40 watt including taking down old unsv complete all as specified and directed. | 32 | Each | 21,200 ₹6,78,400 | 17,490 ₹5,59,680 Lowest | 20,500 ₹6,56,000 | 30,400 ₹9,72,800 | 20,000 ₹6,40,000 | 20,400 ₹6,52,800 |
| 6.00 | S&F of IP65 rated inverted pyramid tripod type LED Bolard 10 W with soft 360 light distribution including taking down old unsv complete all as specified and directed. | 50 | Each | 5,555 ₹2,77,750 | 850 ₹42,500 Lowest | 6,000 ₹3,00,000 | 3,175 ₹1,58,750 | 6,500 ₹3,25,000 | 7,850 ₹3,92,500 |
| 7.00 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed. | 180 | Cum | 125 ₹22,500 | 120 ₹21,600 | 85 ₹15,300 | 170 ₹30,600 | 190 ₹34,200 | 80 ₹14,400 Lowest |
| 8.00 | Excavating over areas, exc 1.5 m deep and getting out complete all as specified and directed. | 18 | Cum | 135 ₹2,430 | 135 ₹2,430 | 140 ₹2,520 | 40 ₹720 Lowest | 250 ₹4,500 | 300 ₹5,400 |
| 9.00 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. | 98 | Cum | 30 ₹2,940 Lowest | 42 ₹4,116 | 30 ₹2,940 Lowest | 40 ₹3,920 | 100 ₹9,800 | 40 ₹3,920 |
| 10.00 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. | 82 | Cum | 50 ₹4,100 | 42 ₹3,444 | 30 ₹2,460 Lowest | 40 ₹3,280 | 90 ₹7,380 | 40 ₹3,280 |
Tender Value
₹48.2 L
EMD Value
₹96,460
Closing Date
13 Jul 2026, 6:00 pmClosed
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
SPECIAL REPAIR/ REPLACEMENT OF VARIOUS TYPES OF STREET LIGHTS, FLOOD LIGHTS, JUNCTION BOX AND OTHER ALLIED WORKS UNDER GE (MCTE) MHOW
2026_MES_772030_1
GE(MCTE)/MHOW/12(T) OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (MCTE) Mhow
As per Tender Document
10 documents required · 10 mandatory
₹500
GE (MCTE) Mhow
₹96,460
Yes
11 Sept 2026
15 Jun 2026
15 Jul 2026
15 Jun 2026
13 Jul 2026
29 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F in repair of LED street light Luminaies 90 watt wih IP 66 rating. LEDs shall have optical grade polycarbonate/PMMA lens to provide street light distribution. The fixture should be made of pressure die cast Aluminium/ Aluminium Extrusion and clear flat glass. The housing should be with manufacturer's name embossing permanent mark on the die cast housing (Stickering/ screen printing is not acceptable). Control gear shall be provided with die cast aluminum cover for safety. Short Circuit protection should be such that it recovers automatically after fault condition is removed. Integral control gear, IK 08 or above. The fixture should have lumen maintenance of at least 70% at 50000 burning hours at ambient temp of 35 degree C. The driving current for LED should be Max 1A ±10 % . CCT should be 5700 K (+-300K). The efficacy of fixture should be at least 130 lumens/ watt. The power factor of driver should be > 0.95 and the THD < 10% & Internal surge Protection should be 4Kv internal and 10kv external surge protection should be atleast 10Kv for better saftey of fixture where CRI > 70%. The Fixture should be complete with LED Driver and all other accessories.Fixture should have discrete LED type and not Chip on board for better heat managment system and long life of LED. Vendor should provide third party NABL for LM 79, LM 80 Report of LED street light luminaire. Own lab certificate calming third party won’t be accepted. (reports should not be older than 6 months from the date of tender). Other certificates like ROHS certificate, REACH certificate, Photo biological test report & ISO certification for vendor will be needed. Manufacturer to have his own R&D lab for testing & should be approved from ministry of science government of India. The Lighting Fixtures should be supplied with 5 years Warranty against any manufacturing defect and warranty certificate shall be provided to the department through the OEM. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable complete all as specified and directed. | 80 | Each | 100 | ₹8,000 |
| 2 | All as per Srl item No. 1.00 above but capacity 120 Watts complete all as specified and directed. | 70 | Each | 101 | ₹7,070 |
| 3 | S&F in repair of LED Flood light Luminaires of Wattage 200watt with IP 66 rating. LEDs shall have optical grade polycarbonate/ PMMA lens to provide street light distribution. The fixture should be made of pressure die cast Aluminium having heat sink in Aluminium Extrusion and clear flat glass. The housing should be with manufacturer's name embossing permanent mark on the die cast housing (Stickering/ screen printing is not acceptable). Control gear shall be provided with die cast aluminum cover for safety. Short Circuit protection should be such that it recovers automatically after fault condition is removed. Integral control gear, IK 07 or above. The fixture should have lumen maintenance of at least 70% at 50000 burning hours at ambient temp of 35 degree C. The driving current for LED should be Max 1A ±10 %. CCT should be 5700 K (+-300K). The efficacy of fixture should be at least 120 lumens/ watt. The power factor of driver should be > 0.9 and the THD < 10% & Internal surge Protection should be 4Kv with external surge protection should be atleast 10Kv for better saftey of fixture where CRI > 70%. The Fixture should be complete with LED Driver and all other accessories. Fixture should have discret LED type and not Chip on board for better heat managment system and long life of LED. Own lab certificate calming third party won’t be accepted. Manufacturer to have his own R&D lab for testing & should be approved from ministry of science government of India. vendor should provide third party NABL LM 79 & LM 80. The Lighting Fixtures should be supplied with 3 years Warranty against any manufacturing defect and warranty certificate shall be provided to the department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable, complete all as specified and directed. All certificates required before supply of material. | 50 | Each | 102 | ₹5,100 |
| 4 | All as per Srl item No. 3.00 above but 150 Watt complete all as specified and directed. | 40 | Each | 103 | ₹4,120 |
| 5 | S&F of landscape lighting decorative poles jet black painted galvanized with gold colorpainted decorative rings embelishment of aluminium pdc including landscape LED luminaries of 40 watt including taking down old unsv complete all as specified and directed. | 32 | Each | 104 | ₹3,328 |
| 6 | S&F of IP65 rated inverted pyramid tripod type LED Bolard 10 W with soft 360 light distribution including taking down old unsv complete all as specified and directed. | 50 | Each | 105 | ₹5,250 |
| 7 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed. | 180 | Cum | 106 | ₹19,080 |
| 8 | Excavating over areas, exc 1.5 m deep and getting out complete all as specified and directed. | 18 | Cum | 107 | ₹1,926 |
| 9 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. | 98 | Cum | 108 | ₹10,584 |
| 10 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. | 82 | Cum | 109 | ₹8,938 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
TD12T.pdf
Tender Documents • 0.77 MB
Make12T.pdf
Tender Documents • 0.23 MB
PS-12T.pdf
Tender Documents • 0.31 MB
Undertaking12T.pdf
Additional Documents • 0.10 MB
BOQ_864673.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .