Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.4 LAccepted-AOC | ₹29.4 L Quoted ₹31.2 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹35.3 L+₹4.1 L (13.3%)Rejected-AOC 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | ₹35.3 L+₹4.1 L (13.3%) | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹36.3 L+₹5.1 L (16.4%)Rejected-AOC | ₹36.3 L+₹5.1 L (16.4%) | L-3 | Rejected-AOC L-3 |
| 4 | L-4₹44.3 L+₹13.1 L (42.2%)Rejected-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | ₹44.3 L+₹13.1 L (42.2%) | L-4 | Rejected-AOC L-4 |
Tender Value
Refer Docs
EMD Value
₹79,500
Closing Date
24 Dec 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR / REPLACEMENT OF OLD UNSERVICEABLE LT/HT CABLE, INCLUDING REWINDING OF TRANSFORMER AND REPLACEMENT OF OLD TRANSFORMER OIL AND OTHER CONNECTED WORKS AT ADRDE AGRA UNDER GE I RnD DELHI
2022_MES_564028_1
GE/RND-86/AGR/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Agra
Class-D, Cat-b(i), b(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹79,500
Yes
24 Jan 2023
18 Nov 2022
26 Dec 2022
18 Nov 2022
24 Dec 2022
7 Dec 2022
Amount
Supplying, laying, jointing & testing, 1100 volts grade, heavy duty, LT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed,3.5 Core, 185 Sqmm nominal cross section in service connections laid in loops /ducts, along wall /pole or under floor /road or laid in trenches including taking out old unserviceable cable complete all as specified and directed.
All as per item Ser No. 1.00 above but 120 Sqmm 3.5 Core.
All as per item Ser No. 1.00 above but 95 Sqmm 3.5 Core.
All as per item Ser No. 1.00 above but 70 Sqmm 3.5 Core.
All as per item Ser No. 1.00 above but 50 Sqmm 3.5 Core.
Supplying, laying, jointing & testing 11000 volts grade, heavy duty, HT XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, 3 Core, 95 Sqmm nominal cross-section in service laid in loops /ducts, along wall /pole or under floor /road or laid in trenches connections including taking out old unserviceable cable complete all as specified and directed.
Supply and spread clean dry sand for cable cushioning in trenches all as specified in clause 19.75 of SSR Part-I complete all as specified and directed. Note : Punned thickness shall be measured.
M&L for brick, subclass 'B' well burnt, laid dry flat in trenches for protection of cable with a maximum gap of 10 mm between two consecutive brick over LT cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 m in depth and getting out in soft/loose soil for foundation, LT cable, HT cable etc including leveling and ramming complete all as specified and directed.
Returning, filling in trenches soft/loose soil, including spreading leveling & well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated surplus soil to a distance n.exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
S&F in replacement GI tube light grade 40mm bore including all new fittings, laid in trenches/wall for protection of UG cable complete all as specified and directed.
All as per item Ser No 12.00 above but size 50 mm bore.
All as per item Ser No 12.00 above but size 80 mm bore.
M&L for boring holes by manually / machine under road, pavement, hard standing by trenches for laying of GI pipe of 40/50/80mm bore for cable laying etc complete all as specified and directed. Note: GI pipe will be measured and paid seperately under respective item.
S&F in repair cable jointing kit for 11 KV (earthed) grade cable, for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of 95 Sqmm complete all as specified and directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
S&F in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
S&F in repair cable jointing kit for 1.1 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured aluminium conductor cable of 120 Sqmm complete all as specified and directed.
S&F in repair cable jointing kit for 1.1 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured aluminium conductor cable of 95 Sqmm complete all as specified and directed.
S&F in repair cable jointing kit for 1.1 KV (earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5 Core XLPE armoured aluminium conductor cable of 70 Sqmm complete all as specified and directed.
S&F in repair Copper lugs, E-blot size 10.5 mm, suitable for 25 sqmm 3.5 core to 120 sqmm 3 core cable including crimping/ connecting with UG cable and panel board complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 32x6 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion of the following :- (a) GI strip of size 32mm x 6mm. (b) Watering pipe GI light grade 40mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with GI wire 4.00mm by means of nuts, bolts and washers. GI Wire shall be laid in 20mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) wih following complete all as specified and shown in electrical plate No. 3 of SSR Part-I & testing on completion of the following:- (a) GI wire 4.00mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
S&F MCCB TPN 63 Amp 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable complete all as specified and directed.
S&F MCB TPN 63 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable complete all as specified and directed.
S&F MCB TPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable complete all as specified and directed.
S&F MCB SPN 32 Amp,C curve, 415 Volts, 50 Hz suitable for existing and connection with copper lugs including taking down old unserviceable complete all as specified and directed.
Supply ,installation, testing and commissioning in replacement of canopy headed HT 11K volt grade, 3 phase , AC, 50 cycle, feeder pillar box size 1200x1000x1000 mm, factory made outdoor pedestal type double door, fabricated out of 3.15 mm thick CRCA sheet with powder coated painting in side and outside of approved shade ,locking arrangement with duplicate keys two earthy terminal suitable cable gland for all incoming and outgoing cable grouting of feeder pillar box 15 cm above ground level by providing 90 cm long angle iron of size 50x50x6 mm welded on all the four comers embedded in PCC (1:2:4) using 20 mm graded stone agg upto 30 CM deep and 45 CM above from normal ground level complete all as specified and directed incl the following components:- (a) The panel will be having copper bus bar of size 400×40×6 mm 03 strips with porcelain HT long post insulator Note - HT Feeder pillar will be from CPRI Approved firm.
S&F in replacement busbar chambers 200 Amps 6 way, 415 Volts complete all as specified and directed.
S&F in replacement busbar chambers 400 Amps 6 way, 415 Volts complete all as specified and directed.
S&F in repair on load change over switch including enclosure, 400 Amp, 4 pole with advance neutral including making cable connection to the change over switch, fixing on wall/ floor with mild steel fastener, nut/bolts complete all as specified and directed.
S&F in repair on load change over switch including enclosure, 125 Amp, 4 pole with advance neutral including making cable connection to the change over switch, fixing on wall/ floor with mild steel fastener, nut/bolts complete all as specified and directed.
M&L for filtration/dehydration transformer oil of transformer capacity 50 KVA to 630 KVA indoor/outdoor type, pole mounted / plinth mounted in situ to achieve dielectric strength minimum 40 KV at 4mm gap complete all as specified and directed.
M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and directed. Note :- (a) New transformer oil to be bought in company sealed ISI marked container with original test certificate. (b) Filtration /dehydration of transformer oil shall be carried out at the location where transformer is installed and necessary filter/dehydration plant having pressure gauge, hour meter, temperature gauge to be brought at site by contractor. (c) During process of filtration of oil, transformer shall be on load.
M&L for silica gel grain in the breather assembly of transformer complete all as specified and directed
Taking down transformer carefully of capacity 100-630 KVA from its original position up to road n exc 50 mtr by manually and transportation by vehicle (Recovery van) to other installation n. exc 5 KM to install the transformer at its original position or to work shop for repair and reinstallation after repair complete all as specified and directed.
M&L for rewinding of LT/HT coils suitable for 11000/1100 volts grade with new supper enamelled copper wire having class-F insulation as per existing size and turns of capacity of transformer 100-630 KVA complete all as specified and directed.
M&L for LT bush insulator complete with outer bushing studs made out of brass including oil seal ,gaskets as per existing sample for three indoor/outdoor type transformer of cap for upto 630 KVA (set of four) including taking out the old unserviceable complete all as specified and directed.
M&L for HT bush insulator complete with outer bushing stud, made out of brass including oil seal ,gaskets as per existing size for indoor/outdoor transformer of cap for upto 630 KVA for 11K / 440 Volts including taking out the old unserviceable complete all as specified and directed (Set of three)
Supply and Fixing Packing gasket for top cover and terminal box for HT and LT side as per existing sample for out door/indoor type transformer including nuts, bolts and washer etc for upto 630 KVA transformer (after draining out transformer oil and refilling to the same transformer oil) complete all as specified and directed. Note :- Cost of minor spares i.e nut bolt and washer if required to complete the job is deemed to be included in quoted rates.
M&L for painting of transformer outer surface with one coat of synthetic enamel paint for transformer capacity 100-250 KVA after preparation of old painted surface using spray machine complete all as specified and directed. Note:- After completion of painting HT/LT bushing, oil inspection glass and name plate to be made clean using volatile cleaner, complete all as specified and directed.
All as per item Ser No 42.00 above but capacity of transformer 400-630 KVA.
M&L in replacement air break switch gang operated device HT 11 KV triple pole outdoor type with 12 insulator 200 Amps rating with drop out fuse assembly with fuse carrier and the fuse element mounted on insulator and steel frame mechanically operated with operating mechanism consisting of operating rod of 25mm bore light grade GI pipe of suitable length operative from ground level and with locking arrangement with MS flat iron clamp 50 x 6 mm including MS channel of suitable size and length to fixing of GOD including nuts, bolts and washers complete all as specified and directed.
S&F pin type insulator, porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut 100mm height 65 mm dia for working pressure 1100 volts including dismantling old unserviceable insulator complete all as specified and directed.
M&L in replacement aluminum conductor steel reinforced (ACSR) including copper binding wire complete all as specified and directed.
S&F PVC type over head line spacer for up to four conductor, suitable for 1100 volt grade intended to avoid short circuiting during sagging/storm etc including taking out the old unserviceable complete all as specified and directed.
Supply & fixing/crimping of old/overheated jumpers/service connection with Bimetallic PG Clamp of aluminum alloy with GI nut & bolt and conducting jelly, suitable for weasel / Mink or any other ACSR Conductor including taking out the old unserviceable complete all as specified and directed.
M&L in repair Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated complete all as specified and directed.
Triming/cutting of tree branches up to height 12.00 m to 15.00 m in electric HT/OH lines with both side 3.00 m distance from outer conductor and including surface dressing and removing the material at a distance not exceeding 500.00 m complete all as specified and directed.
Surface excavation in hard/dense soil, not exceeding 30 cm deep and averging average 15cm deep for cleaning the area by cutting the unwanted bushes/vegetation growth in and around the area of installations/around the valve pit chamber/along the pipe line routes if reqd etc complete all as specified and directed.
Labour only for re-stretching/ restringing of existing loosed / sagged ACSR over head conductor of any type and size including fixing with binding wire/aluminium tape of required size, opening from insulators as fixed on pole after taking proper electric shut down from concerned staff including taking down unserviceable conductor from OH line and proper binding with additional conductor and restringing on line complete all as specified and directed.
S&F in repairs lightning arrestor HT,11 KV, 10 KA expulsion type complete with all fittings,transmission class complete all as specified and directed.
S&F Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green 'Two-in-series' assembly for tension with tension clamps for conductors, working pressure 11000 volts including taking down old unserviceable insulator complete all as specified and directed.
S&F in true vartical position steel tubular swaged poles type 410 SP-22 (8.5 meter long) complete with CI base plate pole cap,finial taper plug,bolts, nuts, washers etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking out old unserviceable pole complete all as specified and directed. Note :- (i) The portion above coping shall be painted in alternative bands of colours starting with black colour (each band of 30 cm wide) by two coats of synthetic enamel paint upto 1.5 meter height and the cost of same shall be deemed to be included in the quoted rates. (ii) The pole numbers etc shall be enumerated on the poles and the cost of writing letters with synthetic enamel paint shall be deemed to be included in the quoted rates. (iii) PCC and and exavation shall be measured and paid separately. (iv) The rates also include drilling of holes in steel tubular poles for continuous G.I. earth wire etc. to the required size and number.
S & F steel tubular swaged pole with cast iron base plate finial taper plug,bolts,nuts,and screw as specified type SP-55 (11.0 metres long) including fixing of cross arms ,insulators and all electrical cables/ACSR conductors/earthwires and painting with two coats of aluminium paints over a coat of primer of pole as per sample including taking out the old one complete all as specifies and directed. Note: (i) The portion above coping shall be painted in alternative bands of colours starting with black colour (each band of 30 cm wide) by two coats of Synthetic enamel paint upto 1.5 meter height and the cost of same shall be deemed to be included in the quoted rates. (ii) The pole numbers etc shall be enumerated on the poles and the cost of writing letters with synthetic enamel paint shall be deemed to be included in the quoted rates. (iii) PCC and and exavation shall be measured and paid separately. (iv) The rates also include drilling of holes in steel tubular poles for continuous G.I. earth wire etc. to the required size and number.
M&L for PCC 1:2:4 type B1 using 20 mm graded agregrate as in coping of pole floor furnishes etc including necessary form work complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40 mm graded agregrate as in foundation of pole including necessary form work complete all as specified and directed.
Disconnecting & taking out non functional VCB of circuit current 30 Amps and busbar current 400 Amps, 50 Hz, Panel Type : UN1 VAC for 11 KV Make : Crompton Greaves dismantling / opening of the VCB for servicing / overhauling, taking out and removing unserviceable /defective parts including cleaning & servicing ,greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing complete all as specified and directed. Note :- (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately.
Supply only Tripping Coil 24 / 110V DC Suitable for VCB 11000 Volt of 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Closing Coil 24 / 110V DC Suitable for VCB 11000 Volt. of 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Segment Gear suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Spring Charging motor 220V suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Tripping Latch/Shaft suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Closing Lactch/Lever suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only TNC Switch suitable for VCB 11000 Volt 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Auxiliary Switch 6 No-6NC suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Panel Spout Set, 11 KV suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Jaw Contact suitable for VCB 11000 Volt, of 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Insulator Type - Resin Cast Epoxy, Size - 61mm/130mm 11KV suitable for VCB 11000 Volt, 630 Amp, 3.5 MVA complete all as specified and directed.
Supply only Vacuum Intrepter 11KV suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Current Transformer (CT) Resin Cast Epoxy, 11KV suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Potential Transformer (PT), Dry Type Resin Cast Epoxy, 11KV suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only LED indication Lamp 240V, DC Red, Green and White, 11KV suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only LED indication Lamp 220V, DC Blue, 11kV Suitable for VCB 11000 Volt, 400 Amp, 3.5 MVA complete all as specified and directed.
Supply only Protection 3 Phase Over Current + Earth Fault Relay, 11kV Suitable for VCB 11000 Volt, of 400 Amp, 3.5 MVA complete all as specified and directed.
Maintenance and overhauling of DG set of capacity 400/500 KVA including checking, cleaning, adjusting/tightening, oiling, greasing and reseting of existing part decarbonising of battery terminals of DG set at different location of installation and keep ready to set for proper functioning of valve 'V' belts pulleys, fan hub, idler, water pump, fiters engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbons brushes vibration dampers, springs, AVRs exhause pipes etc complete all as specified and directed. Note : New Spares parts as will if required shall be measured and paid separetely under respective item of BOQ/ Sch 'A'.
Supply only Air Filter suitable for 400/500 KVA DG Set complete all as specified and directed.
Supply only Oil Filter suitable for 400/500 KVA DG Set complete all as specified and directed.
Supply only diesel filter suitable for 400/500 KVA DG Set complete all as specified and directed.
Supply only Water separator suitable for 400/500 KVA DG complete all as specified and directed.
Supply only Coolant for DG Set complete all as specified and directed.
Supply only Engine oil for DG Set complete all as specified and directed.
Disconnecting connection of radiator and taking down for servicing and cleaning and refixing complete all as specified and directed.
Excavation in post holes in soft / loose soil each not exc 0.5 cum and getting out returning filling in and ramming earth or broken rubble and removing surplus soil to a distance not exc 50 mtr complete all as specified and directed.
S&F in repair 4mm dia galvanised steel wire chain link fencing (wire mesh size100x100mm) complete all as specified and directed.
Supply only Mild Steel Round bars Fe-410-W (Gde E-250) quality A complete all as specified and directed.
S&F joist, channel, MS pipe, angle or tee sections as in posts and struts in fencing including cutting to shape as directed drilling holes notching for wire etc, flat iron fillets (for securing wire mesh/chain-link fencing etc) including all necessary drilling, riveting,nut bolt etc and similar work confirming to Gde-Fe-410-0 or Fe-310-0 including dismantling old unserviceable complete all as specified and directed.
M&L for preparation of new steel or iron surface over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F in repair Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doo0rs etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of OH tank,pump houses finished cement concrete surface even and fair including necessary form work and foundation of pole complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
M&L for sand filling floors or pavings laid in layers n exc 15 cm thick ,spread, levelled, and blind earth and rammed in cluding watering complete all as specified and directed.
S&F post top lantern LED type 45 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant with driver and lamp including taking down old unserviceable post top light fitting complete all as specified and directed.
S&F round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof eiling including connecting up with existing light point with three core flexible copper conductor cable of suitable size including taking down old unserviceable round fitting complete all as specified and directed.
S&F LED light fitting 1x9W/1X10 W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable bulk head fitting complete all as specified and directed.
S&F in repair heating element 1500/2000 watts as per existing capacity in round/ triangular shape bottom(Cup shape ) with rubber gasket and fixing to existing geyser complete all as specified and directed.
S&F in replacement thermostat suitable for adjusting the temperature from 0 degree centigrade to 80 degree centigrade for geyser complete all as specified and directed.
S&F in repair brass geyser assembly suitable for 25 Ltr capacity geyser including nuts, washers, check nuts and all connected items complete all as specified and directed.
S&F in repair copper inner tank suitable for geyser of capacity 25 ltr with 6/9 numbers of holes complete all as specified and directed.
S&F in repair cover outer of geyser complete including top and bottom suitable for 25 Ltr capacity geyser of any make, shape and size as per existing, gauge of sheet not less than 22 SWG complete all as specified and directed.
S&F in repairs PVC connection 15mm size with CP brass nuts and PVC washer, 450mm long for hot/cold water fittings complete all as specified and directed.
M&L painting of complete outer body of storage type geyser of capacity 25 to 50 litres with two coat of synthetic enamel paint including preparation of surface and including writing of MES No with black synthetic enamel paint complete all as specified and directed.
S&F in repair GI tubing 15 mm dia medium grade ISI Marked, laid in trench/floor or fixed on wall with all fixing accessories etc complete all as specified and directed.
S&F in replacement Rubber Gasket flange as per site requirement for 25/50 ltr geyser including taking out the old one complete all as specified and directed.
S&F in repair stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete of 15 mm dia complete all as specified and directed.
S&F Top plug 15 amps 3 pin , 240 Volts including taking out the old unserviceable complete all as specified and directed.
Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core conforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primer with top cover 3 mm thick bakelight laminated sheet with brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthed stranded copper conductor cable 2.5 sqmm single core in green colour as earth wire connected to earth dolly including taking down old unserviceable point wiring complete all as specified and directed .
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with mpact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old unserviceable light fitting complete all as specified and directed.
M & L for dismantling and removing of MS fuel tanks any size/ type by disconnecting of fuel pipes connection, draining out of oil from the tank, cleaning and removing sediments, dirts etc from fuel tank including repairing of fuel gauge dial type by replacing unserviciable parts etc complete for 500 KVA Capacity DG Sets complete all as specified and directed.
Supply, fixing and testing in replacement new self starter motor 12V/24 DC complete all as specified and directed.
Supply, fixing and testing of maintenance free battery 12 Volts 180 AH complete all as specified and directed.
Supply, fixing including testing of new Automatic voltage regulator suitable DG Sets of capacity 500 KVA including taking down old unserviceable voltage regulator complete all as specified and directed.
S&F in repair flexible rubber coupling of engine and alternater with bolts and nuts etc of suitable size complete all as specified and directed for 500 KVA Capacity
Taking out FIP from DG set for 500 KVA capacity, transporting up to nearest workshop for calibration including calibration of FIP from authorised workshop, transporting back, refixing the same in DG Set including testing for smoth functioning complete all as specified and directed.
M/S OM Enterprises
M/S GUPTA ENTERPRISES
M/s SCHOLASTIC ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .