EXECUTIVE ENGINEER
132 KV SUB STATION NAUGARH
REPLACEMENT/CONFIGURATION AND INTIGRATION OF 01 NO. BCU, INTERCONNECTION WIRING CON. RELAY PANEL FOR 220KV TRANSFER BUS-COUPLER BAY AT 220 KV SUBSTATION BANSI
2026_UPTCL_1212808_1
E-tender no.43-2026-27
Open Tender
Electrical Works
Lump-sum
30 days
SIDDHARTHNAGAR
AS PER TENDER
2 documents required · 2 mandatory
₹590
ELECTRICITY TRANSMISSION DIVISION II BASTI
₹1,000
27 Nov 2026
27 Nov 2026
5 Dec 2026
27 Nov 2026
4 Dec 2026
27 Nov 2026
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fixing of BCU & O/C E/F Relay at TBC Bay Control & Relay Panel installed in BCU room by opening of cable connections & damaged BCU & O/C E/F relay. Work Including safe connection of 220 KVTBC Bay and cable loop, panel to panel (PGCIL/BASTI/160 MVA T/F-I&II) connection for Isolator Status to protection transfer of other running 220 KV bay as required. The work also includes identification of the control cables by providing suitable ferrules, checking of DC Leakage etc. completion of work schedule shall be provided as executed mentioning Cable Tag, TB No. & ferrules for C&R Panel. | 1 | No. | - | - |
| 2 | Testing of all 220 KV bay (PGCIL/BASTI/160 MVA T/F-I&II) Circuit breaker Manual/Protection operation shall be done jointly with T&C wing including troubleshooting as needed/necessary, until protection relay of each 220 KV bay operated through TBC Panel with the help of electronic secondary relay testing kit. | 1 | No. | - | - |
| 3 | Configuration, Integration and testing of new installed BCU (Micom/Micmo make) including Data validation from SCADA Display in Main control room. Including replacement LAN Cable from BCU to Main control room. All other associated works to complete the job satisfactorily. | 1 | No. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
BOQ_2306985.xls
BOQ • 0.25 MB
TECHNICALDOC43.pdf
Tender Documents • 2.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .