Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I M I CA CWS I Cooling Tower II Overhauling of Flow Control Valves and including reconditioning of released FCV spares during AOH 2026 2027 of Unit II
2026_EB_710390_1
CE / MTPS-I / SE / M-I / CA /OT.118/ 2026 -27
Open Tender
Power/Energy Projects/Products
Works
20 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹5,200
Yes
1 Oct 2026
1 Oct 2026
16 Oct 2026
1 Oct 2026
15 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for dismantling of inspection doors provided at Flow Control Valve assembly casing. Dismantling of Flow control valve assembly (about 300 kg weight) from taping pipe flange of hot water header line. Reassembling the same by using Rubber gasket properly without water leakage. Open/close operation checking works. | 22 | Nos | - | - |
| 2 | Charges for Dismantling of Flow control valve spares from Flow Control Valve assembly for cleaning, inspection and to renewal of worn-out spares like guide bush, stem, CI disc, lock nut, locking bar and operating handle etc. and reassembling the Flow Control Valve assembly. | 22 | Nos | - | - |
| 3 | Charges for dismantling the GI casing / concrete block of FC valve to facilitate the OH of FCV & renewal of nozzles etc., and reassembling the same. | 22 | Nos | - | - |
| 4 | Charges for reconditioning Flow control valve casing for fixing inspection doors by Drilling and removal of existing 8 Nos of eroded M10 / M12 stud, making 8 Nos of new M 10 / M12 thread on the valve body by using tap set. | 22 | Nos | - | - |
| 5 | Charges for reconditioning of worn-out Flow Control Valve (FCV) spares released from Cooling Tower –II at outside workshop, Re boring of GI Disc, fabrication and assembling of M.S. flange on CI Disc, moulding of new CI guide bush, machining, drilling & thread cutting on new bush to suit with the existing S.S. Stem. Reconditioning of released S.S. Stem by rethreading and suitable to end nut with 2 Nos. of plate washers for 1 No. stem including transporting charges. | 11 | Nos | - | - |
| 6 | Charges for removing the existing damaged Nitrile rubber from the M. S Flange of FCV’s in Cooling Tower. Cleaning and sand blasting on both the surface for Nitrile rubber impregnation, moulding the Nitrile rubber over the flange for 5 mm thick on each side ( the size of the flange to be impregnated is OD-640mm; ID-450 mm) trimming and steam vulcanizing ,including the cost of Nitrile rubber, adhesive and also charges including transporting charges of released FCV spares from MTPS-I to outside work shop and return back same to MTPS-I. | 11 | Sets | - | - |
| 7 | Charges for transportation of Stop log gate from clarifier area, leading, lifting, positioning and inserting the stop log gate in the cold water Outlet canal of CT to facilitate the cold water dewatering work. After completion of dewatering work removing, leading, transporting and placing the stop log gate in the clarifier area. | 1 | Set | - | - |
| 8 | Charges for removing the rust and old paint from all 22 Nos. of Flow control valve casing along with tapping pipe. | 43 | M² | - | - |
| 9 | Charges for painting of one coat of epoxy red oxide primer and two coats of sea green paint on outer surface area of Flow Control Valve casing along with tapping pipe and casing frame (43 M2), CT ID fan door and its frame structures (81M2),cleaning & painting with one coat of epoxy red oxide primer and two coats of enamel sea green paint one over the other with proper interval on the stop log gate stands, including cleaning the surface of the area to be painted (21M2). | 145 | M² | - | - |
| 10 | Charges for cleaning and painting with epoxy red oxide primer and Two coats of epoxy coal thar black paint in the inner surface of Flow Control valve taping pipe (12M2), inner surface of FCV body (21M2) and on the surface of 2 Nos. Stop Log gates (28M2). | 61 | M² | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
BOQ_853549.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .