Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC 0 H O SIDHARTH SHANKAR ROY DIGHA GHAT DIGHA PATNA BIHAR 800011 UDYAM BR 26 0085368 | PATNA | BIHAR | 800011 | ₹16.7 L Quoted ₹17.4 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹17.9 LRejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹17.9 L | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹26.3 LRejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹26.3 L | L3 | Rejected-Finance BEING L3 |
| Sl No | Description | Qty | Unit | sapana enterprises L3 | Sagar Electricals L2 | M/S KHUSHI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | REPAIR/MAINT OF FANS:- Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismentaling of blades, canopy, down rod etc & remove to store for repair. & Refix the same including provision of 3 core 0.5 sq mm copper flexiable cable from ceiling rose to connector complete all as specified and directed. | 575 | EACH | 25 ₹14,375 | 60 ₹34,500 | 20 ₹11,500 |
| 2.00Material and labour for Opening of body cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge:- | ||||||
| 2.01 | Ceiling fan 1200 / 1400 mm Sweep complete all as specified and directed. | 450 | EACH | 650 ₹2.9 L | 380 ₹1.7 L | 500 ₹2.3 L |
| 2.02 | Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep complete all as specified and directed.. | 60 | EACH | 650 ₹39,000 | 420 ₹25,200 | 500 ₹30,000 |
| 2.03 | Exhaust Fan, Pedastal fan,wall fan, 380 / 450 mm Sweep complete all as specified and directed. | 40 | EACH | 650 ₹26,000 | 420 ₹16,800 | 500 ₹20,000 |
| 2.04 | Wall Fan,pedastal fan 600 mm Sweep complete all as specified and directed.. | 25 | EACH | 650 ₹16,250 | 420 ₹10,500 | 500 ₹12,500 |
| 3.00 | Material and labour Painting only of ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, scraping out of old paint filling of cavities with filler preparation of body and clearing of dust etc Painting by Spray with first Quality Paint including rewriting of MES number complete for all as directed | 575 | EACH | 60 ₹34,500 | 150 ₹86,250 | 50 ₹28,750 |
| 4.00 | Material and labour Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep Oiling, Greasing including removing all dust and replacement of Split Pin and Bolts, Nuts and Screws as in repair complete all as specified and directed.
Note : Spares shall be measured & paid under item 4.01 to 4.21 | 325 | EACH | 60 ₹19,500 | 42 ₹13,650 | 50 ₹16,250 |
| 4.01 | Capacitor up to 2.5 mfd 230 volts AC complete all as specified and directed. | 250 | EACH | 60 ₹15,000 | 42 ₹10,500 | 50 ₹12,500 |
| 4.02 | Capacitor 4.0 mfd, 230 volts, AC complete all as specified and directed. | 75 | EACH | 60 ₹4,500 | 60 ₹4,500 | 50 ₹3,750 |
Updated dates
Tender Value
₹25.5 L
EMD Value
₹51,000
Closing Date
29 Oct 2025, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIRS / MAINTANANCE OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, PEDESTAL FANS, DG SET AMF PANEL AND OTHER CONNECTED E/M WORKS AT SNCO MESS AIRMENN MESS, DSC MESS, LOS 765 SU OLD AIR PORT AREA UNDER OF AF STN KALINA UNDER GE AF THANE
2025_MES_733662_1
GE (AF) T-40 OF 2025-26 (8533)
Open Tender
Electrical and Maintenance Works
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹51,000
Yes
24 Dec 2025
3 Oct 2025
5 Nov 2025
3 Oct 2025
29 Oct 2025
17 Oct 2025
Amount
REPAIR/MAINT OF FANS:- Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismentaling of blades, canopy, down rod etc & remove to store for repair. & Refix the same including provision of 3 core 0.5 sq mm copper flexiable cable from ceiling rose to connector complete all as specified and directed.
Material and labour for Opening of body cleaning of slots, Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge:-
Ceiling fan 1200 / 1400 mm Sweep complete all as specified and directed.
Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep complete all as specified and directed..
Exhaust Fan, Pedastal fan,wall fan, 380 / 450 mm Sweep complete all as specified and directed.
Wall Fan,pedastal fan 600 mm Sweep complete all as specified and directed..
Material and labour Painting only of ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, scraping out of old paint filling of cavities with filler preparation of body and clearing of dust etc Painting by Spray with first Quality Paint including rewriting of MES number complete for all as directed
Material and labour Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep Oiling, Greasing including removing all dust and replacement of Split Pin and Bolts, Nuts and Screws as in repair complete all as specified and directed. Note : Spares shall be measured & paid under item 4.01 to 4.21
Capacitor up to 2.5 mfd 230 volts AC complete all as specified and directed.
Capacitor 4.0 mfd, 230 volts, AC complete all as specified and directed.
Capacitor clamp with connector As per sample complete all as specified and directed.
Rubber insulator sutiable for any type of ceiling fan complete all as specified and directed..
Mild steel down anti sucide rod with clamp nut bolts & split pin for 600 mm long as par sample complete all as specified and directed.
Mild steel down anti sucide rod with clamp nut bolts & split pin for 850 mm long as par sample complete all as specified and directed.
Exhaust fan bracket with frame nut, bolt, Rubbers etc complete 300 mm sweep as par sample complete all as specified and directed.
Exhaust fan bracket with frame nut, bolt, rubbers etc complete 380/ 450 mm sweep as par sample complete all as specified and directed.
Ball bearing sutiable for any type of fans complete all as specified and directed.
Gun metal bush as per sample sutiable for any type of fans complete all as specified and directed.
Ceiling fan Blade suitable for 1200/1400 mm sweep as per sample complete all as specified and directed.
Exhaust fan blade suitable for 300 mm sweep as per sample complete all as specified and directed.
Exhaust fan blade suitable for 450 mm sweep as per sample complete all as specified and directed.
Pedestal/wall fan blade suitable for 450 mm sweep as per sample complete all as specified and directed..
Pedestal / wall fan blade suitable for 600 mm sweep as per sample complete all as specified and directed.
Ceiling fan canopy set of two as par sample complete all as specified and directed.
Wall fan regulator as per sample complete all as specified and directed.
Exhaust fan louvers with wire mesh of size 450mm sweep complete all as specified and directed.
Exhaust fan louvers with wire mesh of size 300 mm sweep complete all as specified and directed.
Fan regulator electronic step type 240 V complete all as specified and directed
Material and labour fan step regulator, 120W - 2 module complete all as specified and directed
Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose's lamp holder from existing batten PVC conduit/steel conduit / PVC casing and capping wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match all as specified and directed by Engr-in-Charge
Taking down main Switches,MCB DB with MCBs complete all as specified and directed
Taking down sub main wiring of any sizes complete all as specified and directed
M & L for point wiring with FRLS insulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC casing capping and accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers all as specified for the following :-
One light / fan/bell point controlled by one way switch
One socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
M & L for point wiring with FRLSinsulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC conduit and accessories, concealed in wall conduit on ceiling (for fan/downlighter only) etc with necessary fixing accessories and earth continuity conductor cable of size 1.5 Sqmm green colour Connected to common earth and earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers including making good the disturbed surface and painting the surface with color matching to the wall color all as specified for the following :-
One light / fan/bell point controlled by one way switch
One socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per Sl item No 9 herein before but with 2.5 Sqmm for phase & neutral and 2.5 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed
All as per Sl item No 9 herein before but with 4 Sqmm for phase & neutral and 4 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed
Supply and Fix in repairs of Switch piano flush type single pole one way 5 Amp complete all as specified and directed .
Supply and Fix in repairs of Ceiling rose surface bakelite two to three terminal complete all as specified and directed .
Supply and Fix in repairs of Fan regulator electronic step type 240 V complete all as specified and directed .
Supply and Fix in repairs of Bell push flush type 5 Amps complete all as specified and directed .
Supply and Fix in repairs of Electronic Call Bell 230 volts single pole AC complete all as specified and directed .
Supply and Fix in repairs of Switch socket combined two in one 06 pin 5/15 Amps flush type universal complete all as specified and directed .
Supply and Fix in repairs of Switch Socket multipurpose 5 pin 5 Amps 240 V flush type complete all as specified and directed .
Supply and Fix in repairs of Lamp holder,insulated body with back plate complete all as specified and directed
M&L MCCB DB verticle type made of sheet steel , powder painted with neutal bus bar 200 A, neutral link, IP-30-IK08 protection grade , 415Volts TPN with 8 way Double door complete all as specified and directed,
M&L MCCB DB verticle type made of sheet steel , powder painted with neutral bus bar 200 A, neutral link, IP-30-IK08 protection grade , 415Volts TPN with 4 way Double door complete all as specified and directed
M&L MCCB TPN 100 Amps , 415Volts, 25KA ,3 Polecomplete all as specified and directed
M&L MCCB TPN 160 Amps , 415Volts, 25KA ,3 pole complete all as specified and directed
Supply and Fix in repairs of MCB DB SPN 8 Way Double door type 240 Volts complete all as specified and directed .
Supply and Fix in repairs of MCB DB TPN 4 Way double door type 415 V with bus bar complete all as specified and directed .
Supply and Fix in repairs single pole and neutral enclouser with a two pin and earth and metal clad plug socket complete with one single pole MCB 25 Amp 240 Volts complete all as specified and directed.
Supply and Fix in repairs of MCB TPN 63 Amps 415 Volts complete all as specified and directed .
Supply and Fix in repairs of MCB SP 06 to 32 Amps 240 Volts complete all as specified and directed .
Supply and Fix in repairs of SPN 6- 40 Amps 240 Volts complete all as specified and directed .
Supply and Fix in repairs of MCB SPN 63 Amps 240 Volts complete all as specified and directed
Supply and Fix in repairs of MCB SPN 100 Amps 240 Volts complete all as specified and directed NOTE FOR ITEM NO 26 to 37 :- (a) Unit rate includes for cutting the brick walls to accommodate DB to make flush with wall/ DB tobe fixed on wall including frame made out of MS flat 40x5mm. (b) Unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
M&L for Sub Main wiring with two single core 2.5 Sqmm FRLS insulated multistranded flexible copper conductor cable 660/1100 volts grade drawn in through rigid flexible PVC casing -n- caping/PVC conduit with and including PVC insulated 2.5 Sqmm single core multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly all as specified and as directed. Note:- 1. Two runs of cable and one run of earth wire incl PVC conduit will be measured and paid one unit. 2. Separate sub main wiring will be run for each accn
M&L for Sub Main wiring complete with 4.0 Sqmm FRLS insulated 1100 Volt grade with multistranded copper conductor cable with and including drawn through PVC casing -n- caping/PVC conduit with all accessories fixed on Walls/floors/roofs with and including pressed steel terminal sunken boxes fixed on the existing sunken portion (Where the old boxes are removed under respective item) with 3 mm laminated bakelite sheet top cover fixed with cadmium plated screws,cup washer for housing metal clad plug socket for AC Point including provision of 4 sqmm PVC insulated copper wire as earth continuity conductor and connecting to common earth dolly all as specified.
All as per item No. 205 herein before but with 6 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable drawn in through PVC casing -n- caping/PVC conduit complete with all accessories including provision of 6.0 sq mm FRLS insulated copper wire as earth continuity conductor all as specified and as directed.
S & F LED retrofit lamp B-22 holder based with polycarbonate body and aluminium heat sink with warm white, 7W LED Lamp, all as specified and as directed by Engr-in-Charge.
S & F LED retrofit lamp B-22 holder based with polycarbonate body and aluminium heat sink with warm white, 9W LED Lamp, all as specified and as directed by Engr-in-Charge at site
S&F anti suicide ceiling rod (12",18") white/brown,others including metallic as per need,MS pipe zinc plated pipe OD -19mm,thickness 1.08+/-0.05mm,spring set 3 carbon spring steel material,zinc plated,MSME tested ,load of 22kgs come on the anti suicide impact fan rod,the rod will get open from centre,spring inside will be expanded, fan clamp with rubber reel nut bolt & safety pin as suitable for ceiling fan complete all as specified and directed
S&F for energy efficient light emmitting LED light fitting 1x10 watt Two feet LED tube light with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed
S&F in Repairs LED Light luminaries Square type 36W suitable suitable for Modular/pop/Gypsum ceiling with starter, connector block, etc,complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible conductor of copper with PVC square blocks of size 600mmX600mm for fixing the fittingcomplete all as specified and directed.
Material and labour Modular white cover plate with frame of following types complete all as specified and directed:-
White cover plate with frame, 1 module
White cover plate with frame 2 module
White cover plate with frame 4 module
White cover plate with frame 6 module
White cover plate with frame 8 module
Material and labour Modular switch 1 way 6A, 1 module complete all as specified and directed.
Material and labour Modular Bell push, flush type, 5 ampcomplete all as specified and directed.
Material and labour Fan step regulator, 120W - 2 module complete all as specified and directed.
Material and labour Mouduler metal box flush type 1 /2/3 module complete all as pecified and directed.
Material and labour Mouduler metal box flush type 4 module complete all as specified and directed.
Material and labour Mouduler metal box flush type 6 module complete all as specified and directed.
Material and labour Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch 16 Amps complete all as specified and directed.
REPAIR/MAINT OF DG SET:-
Ckeck the sample of coolent concentration.
Check the fan belt for tension and replace if needed.
Check exhaust condensate drain and remove any debris or dust.
Examine the charge level of batteryand check for any loose connection and de-scale carbon deposits if any on terminals and application jelly.
Check the air cleaner componenets and clean the dirt with air pressure.
Check and adjust the voltage level of the battery charger.
Drain out the water from the container of the bottom of the filter housing and fuel tank.
Check the control panel wiring, Instrumentation, contacts fuses, etc.
Check the specific gravity of battery every month and condition of Plates once in three months.
Check the serviceability of safety controlls of Engine.
Checking fo all electricalconnectons for its proper tightness.
Check AVR connections & power cable connections for tightness.
Check RPM/Frequency and adjust it.
Checking of Load balancing of alternator/AMF panel output.
Check the condition wire breaded / nonbreaded hoses of engine.
Replace the fuel filter and oil filter.
Clean the crank case breather.
Check the radiator hoses.
Greasing of Alternator Bearing
Cleaning the diesel tank.
Check the installation.
Check the installation.
Checking of exhaust back pressure.
Checking of temperature of exhaust.
Check the performance of radiator.
Checking of all rotary and stationery parts of engine and adjust/repair the defects as required for satisfactory running of DG set.
Cleaning and refitting the air cleaner.
Cleaning of fuel filter assembly and replacement of filter element along with rubber 'O' ring.
Renewal of oil filter elements including checking of serviceability of lubricants oil pump and repair where necessary for proper oil pressure.
Drain out the lub oil and refill new oil after proper cleaning.
Note :- (i) DHPP required for testing will be supplied by the Department under sch 'B' for free for filling. (ii) In case of any breakdown service engineer shall attend the break down immediately and make the DG Set Serviceable within 24 working hrs. (iii) Repair, if any must be carried by Contractor through authorised workshop of original manufacturer and Payment will be made to the contractor on Produce of Original Manufacturer's Bills/vouchers.
All as per ser item No 39 (39.01 to 39.31) here- in- before but for DG Set 75 KVA, qty - 02 Nos make:- Kirloskar , Location : LOS 765
All as per ser item No 39 (39.01 to 39.31) here- in- before but for DG Set 160 KVA, qty - 01 Nos make:- Kirloskar , Location :MAO HQ 765 SU
All as per ser item No 39 (39.01 to 39.31) here- in- before but for DG Set 40 KVA, qty - 03 Nos make:- Kirloskar , Location : Kalina Campus & 121 HF
All as per ser item No 39 (39.01 to 39.31) here- in- before but for DG Set 30 KVA qty - 01 No make:- Kirloskar , Location : DSC Mess, Santacruz
All as per ser item No 39 (39.01 to 39.31) here- in- before but for DG Set 15 KVA qty 2 Nos make:- Kirloskar , Location : LOS & Kalina Campus
Draining out the old slugs oil from the DG set and replace with new oil as recommended by Mfg. NOTE : Draining out of Oil shall be done twice in year each time reffiling/Top up will be measured & paid seperataly.
Disconnecting old unserviceable battery 12 Volts DC upto 180 AH from Engine & transporting to work shop for refilling electrolite, distilled water, checking of sp gravity complete & initial charging of the battery for 48 hours min, transporting back to site , reconnecting up complete all as directed by EIC at site
Servicing of AMF Panel suitable for 15 KVA DG Set to 75 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs all as directed NOTE :- Spare parts shall be measured and paid sepretely in respective item of this schedule if required.
M&L in replacement for MCB SP 6 amp AC/DC.
M&L in replacement forLED type Indicator.
M&L in replacement for Control relay 9/11 pin 12 /24 volt DC.
M&L in replacement for Micro processor unit for automatic and manual function as specified.
M&L in replacement for Contactor four pole 165 amp coil voltage 230 volt AC.
M&L in replacement for Contactor Type ML-4.
M&L in replacement for Contactor Type ML-2. Make:- L&T
M&L in replacement for CT of ratio upto 150 / 5 10 VA burdan.
Servicing of DG Manual Panel suitable for 15 KVA DG Set to 75 KVA DG Set including cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, replacement of control fuses / MCBs all as directed NOTE :- Spare parts shall be measured and paid sepretely in resppective item of this schedule if required.
M&L for in replacement Fault Indicator Control Relay Model No SU 01 of RB Electronics of Kirloskar
M&L for in replacement Fault Indicator Control Relay Model No KRB 101 of RB Electronics of Kirloskar
M&L in replacement for temperature gauge.
M&L in replacement for Oil Pressure Guage 0-10 Bar.
M&L in replacement for Digital Frequency meter.
M&L in replacement for DC Volt meter 0 to 30 volt .
M&L in replacement for DC ammeter 0 to 2 amp.
M&L in replacement for Excitation coil for 75 KVA DG SET.
M&L in replacement for AVR card for 75 KVA DG SET.
M&L in replacement for AVR card for 15 KVA DG SET.
M&L for Servicing of Self Starter 12/24 Volt DC for 75KVA DG Set, dismantling complete,& replacement of solenoid field coils. cleaning the cummutator strips including replacing the bearing, bends pinion re-assembling, connecting and testing complete all as directed.
Ditto as above but for capacity for 15 KVA DG SET.
M&L in replacement self starter 12 volt DC for 75 KVA DG SET including all accessories completeall as directed .
M&L in replacement self starter 12 volt DC for 15 to 40 KVA DG SET including all accessories completeall as directed.
M&L in replacement oil Feed Pump for Aquastic DG SET for capacity 15 to 75 KVA.
M&L in replacement alternetor for battary charging 12/24 volt DC complete with all accessories.
Draining out the Water from the radiator, dis-mantling the leaking radiator assembly complete from the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing the leaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leaks, transporting the same to the site and re-fixing and testing complete in the presence all as directed.
Ditto all as per item 75 Above but for 15 to 25 KVA DG Set.
M&L for Taking down carefully Old rusted silencer & exhaust pipe from engine scraping & cleaning in side & out side applying one coat of zink primer for out side silencer pipe & providing self adjestive Asbasto Rope 12 mm dia from engine to exhaust pipe and painting with 2 coat of syenthetic enameled paint for expose portation of exhaust; all as directed.
M & L for scraping the peeled paint of DG set, preparing the surfaces, cleaning the dust and dirt etc of (alternator and engine) applying 2 coats of synthetic enamel paint over a coat of red oxide of approved shade and sign writing of SM / MES No on the set all as directed
all as per item 78 above but for 15 KVA to 40 KVA DG Set.
M&L in replacement for solenoid Switch 12 Volt DC.
M&L in replacement for Stopping relay 24 volt DC.
M&L in replacement for Anti - Vibrating Pad suitable for 15 to 40 kVA DG Set.
M&L in replacement for Heavy duty Battery terminal for 12 volt DC battary.
M&L in replacement for Radiator Hose pipe as per existing Set of 2.
M&L inreplacmennt for Door Lock Assembly with key for Acauastic DG SET.
M&L in replacement for Heavy duty Automatic electronic battery charger suitable for 12/24 Volt DC.
M&L in replacement for Ignition Switch for capacity up to 75 KVA DG SET.
M&L in replacement for Solenoid coil for capacityy up to 75 KVA DG SET.
M&L Coolant as required for top up. Make : MAX Supar Cool for Accostic DG SET.
M&L in replacement for Rubber Coupling with nut bolt & washer in between Alternator& Engin & up to 75 KVA DG SET
M&L in replacement for Battery lead with lug as per existing length & size for capacity up to 75 KVA DG SET
M&L for Refilling of distilled water for top up battery 12 volt DC.
M&L inreplacement for Air Filter inside & out side for capacity 15 kVA to 75 KVAR DG SET
M&L in replacement for Primary Fuel Filter for capacity 75 KV DG SET.
M&L in replacement for Secondray Fuel Filter for capacity 75 KV DG SET.
M&L in replacement for Lubricating Oil Filter for capacity 75 KV DG SET.
M&L in replacement for Fuel pipes with benjo bolt and washers.For capacity 75 KV DG SET.
M&L in replacement for V- Belt as per existing size for capacity 75 KV DG SET
M&L in replacement for Diesel pipe PVC Flexible up to 12 mm for capacity 75 KV DG SET.
M&L in replacement for Air Filter inside & out side for capacity up to 40 KV DG SET.
M&L in replacement for Primary Fuel Filterfor capacity up to 40 KV DG SET.
M&L in replacement for Secondray Fuel Filter for capacity up to 40 KV DG SET.
M&L in replacement for Lubricating Oil Filter for capacityy up to 40 KV DG SET.
M&L in replacement for Fuel pipes with benjo bolt and washers. For capacity up to 40 KV DG Set
M&L in replacment for V- Belt as per existing size for capacity 15 to 40 KV DG SET.
M&L in replacement for Diesel pipe PVC Flexible up to 12 mm for capacity up to 40 KV DG Set.
M&L PVC / FRP chequered plates 10 mm and over cut to shape, square / notched ( ordinary and counter sunk , forming holes without any attachment in Quality 'A' all as specified and directed.
M & L in replacement for Voltage Monitoring Relay(VMR).
M & L in replacement for OEN Relay.
M & L in replacement for water pump of capacity 75 KVA for DG set.
M & L in replacement for water pump of capacity 30 KVA for DG set .
M & L in replacement for Coolant Hose set for 75 KVA.
M & L in replacement for Coolant Hose set for 30 KVA- 40 KVA.
M & L in replacement for Fuel hose set for 75 KVA.
M & L in replacement for Fuel hose set for 30 KVA-40 KVA.
M & L in replacement for Air filter element for 75KVA.
M & L in replacement for Air filter element for 30 KVA- 40 KVA.
M&L for replace to acoustic canopy of size appx 3 mtr X 1.2 Mtr X 1.5 mtr of 75 kVA & 82.5 KVA DG set incl painting matching with the existing color code and coushion pads , complete all as specified and as directed .
Ditto as per Srl Item No 118 above but of size appx 2 mtr X 1.2 Mtr X 1.5 mtr of 15 kVA DG set incl painting matching with the existing color code and coushion pads , complete all as specified and as directed .
M&L Battery 12 Volts DC upto 180 AH suitable to startng of DG set with warrenty of five year complete all as specified & directed.
M&L for Battery 12 Volts DC upto 92 AH suitable to startng of DG set with warranty of five year , complete all as specified and as directed .
M&L for repair to SFC of Capacity 2KVA working at input voltage 415 Volt 3 Phase power Supply and Output voltage 36 Volt 3phse at frequency of 400HZ and out put voltage adjustment phase to phase and Phase to neutral 32 to 40 Volts . a) Replacement transformer of suitable range to required output with suitable gauge of copper enamelled wire all as per manufacturer specification and site requirement – 01 No b) Replacement control card - 01 No c) Replacement of display meter -01 No
M&L for repair to SFC of Capacity 2KVA working at input voltage 415 Volt 3 Phase power Supply and Output voltage 115 AC Volt Single phse at frequency of 400HZ and output voltage adjustment phase to phase and Phase to neutral 115 Volt Make -Aplab a) Replacement transformer of suitable range to required output with suitable gauge of copper enamelled wire all as per manufacturer specification and site requirement – 01 No b) Replacement control card - 01 No c) Replacement of display meter -01 No
M&L for repair to DCPs of Capacity 3 KVA working at input voltage 415 Volt 3 Phase power Supply and Output voltage 27 DC Volt Single phase adjustment range 0f 25 Volt to 32.5 Volt DC , output current 111 Amp AC and adjustment phase to phase and Phase to neutral 115 Volt . a) Replacement transformer of suitable range to required output with suitable gauge of copper enamelled wire all as per manufacturer specification and site requirement – 01 No b) Replacement control card - 01 No c) Replacement of display meter -01 No
Sagar Electricals (BID ID -3455925)
sapana enterprises (BID ID -3455917)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
TD8533.pdf
Tender Documents • 2.05 MB
BOQ_821466.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid