Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.1 CrAccepted-AOC | ₹2.1 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹2.2 Cr+₹7.1 L (3.37%)Rejected-AOC | ₹2.2 Cr+₹7.1 L (3.37%) | L-2 | Rejected-AOC Other than L-1 |
| 3 | L-3₹2.2 Cr+₹9.9 L (4.71%)Rejected-AOC 1252 SECTOR 15 PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | ₹2.2 Cr+₹9.9 L (4.71%) | L-3 | Rejected-AOC Other than L-1 |
| 4 | L-4₹2.4 Cr+₹33.4 L (15.9%)Rejected-AOC 6313 14 PUNJABI MOHALLA AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹2.4 Cr+₹33.4 L (15.9%) | L-4 | Rejected-AOC Other than L-1 |
| 5 | L-5₹2.8 Cr+₹71.2 L (34.0%)Rejected-AOC 452 1 STREET NO 2A KAULAGARH ROAD RAJENDRA NAGAR DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹2.8 Cr+₹71.2 L (34.0%) | L-5 | Rejected-AOC Other than L-1 |
| Sl No | Description | Qty | Unit | Parveen Builders L1 | M/s Om parkash L2 | Sham Sunder Bansal L4 | K L Kataria and Sons L3 | B.K.ASSOCIATES L6 | M/S SEWA AND SERVE BUILDERS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge. | 3,070 | SQM | 18 ₹55,260 | 50 ₹1,53,500 | 15 ₹46,050 | 40 ₹1,22,800 | 90 ₹2,76,300 | 10 ₹30,700 Lowest |
| 2.00 | Demolition of stone slabs of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. including complete removal of debris outside MD land complete all as specified and as directed by Engineer-in-Charge. | 13 | TEN SQM | 180 ₹2,340 Lowest | 400 ₹5,200 | 200 ₹2,600 | 400 ₹5,200 | 1,800 ₹23,400 | 500 ₹6,500 |
| 3.00 | M&L for Non Skid ceramic coloured tiles, 8mm thick, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick cement mortar (1:6) screed bed for floor finishes complete all as specified and as directed by Engineer-in-Charge. | 450 | SQM | 1,100 ₹4,95,000 | 900 ₹4,05,000 Lowest | 925 ₹4,16,250 | 950 ₹4,27,500 | 1,100 ₹4,95,000 | 999 ₹4,49,550 |
| 4.00 | M&L for Glazed ceramic coloured printed tiles in vertical surfaces of size 300 x 450 x 7 mm set and jointed in neat cement slurry over 10 mm thick rendering in CM 1:4 for receiving the tiles complete all as specified and as directed by Engineer-in-Charge. | 1,550 | SQM | 1,000 ₹15,50,000 | 900 ₹13,95,000 | 787 ₹12,19,850 Lowest | 900 ₹13,95,000 | 1,100 ₹17,05,000 | 1,100 ₹17,05,000 |
| 5.00 | M&L for Glazed/ Matt finish coloured tiles of size 300 x 450 mm, 7-8 mm thick over for wall cladding purpose, colour and design of tiles as approved by GE over and including 10 mm thick rendering in CM 1:4 7 - 8 mm thick complete all as specified and as directed by Engineer-in-Charge. | 100 | SQM | 100 ₹10,000 Lowest | 950 ₹95,000 | 800 ₹80,000 | 1,000 ₹1,00,000 | 1,100 ₹1,10,000 | 1,100 ₹1,10,000 |
| 6.00 | M&L for Vitrified Ceramic tiles 10 mm thick, Dark shade (square/ rectangular), polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm screed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge. | 570 | SQM | 1,200 ₹6,84,000 | 1,150 ₹6,55,500 | 877 ₹4,99,890 Lowest | 1,050 ₹5,98,500 | 1,400 ₹7,98,000 | 1,250 ₹7,12,500 |
| 7.00 | All as per serial item no 6.00 here-in-above but as in skirting over and including 10 mm rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge. | 23.5 | SQM | 1,200 ₹28,200 | 1,200 ₹28,200 | 877 ₹20,609.5 Lowest | 1,100 ₹25,850 | 1,500 ₹35,250 | 1,450 ₹34,075 |
| 8.00 | M&L for 16-18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl laid over including 20 mm thick screed bed in CM 1:4 in skirting/ dado complete all as specified and as directed by Engineer-in-Charge. | 130 | SQM | 4,200 ₹5,46,000 | 3,000 ₹3,90,000 | 2,725 ₹3,54,250 Lowest | 3,200 ₹4,16,000 | 4,500 ₹5,85,000 | 3,400 ₹4,42,000 |
| 9.00 | Demolition of reinforced concrete such as roofs, floors, beams, staircase, landing, chajjas, facia and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by Engineer-in-Charge. | 3.5 | CUM | 500 ₹1,750 | 600 ₹2,100 | 275 ₹962.5 Lowest | 450 ₹1,575 | 2,200 ₹7,700 | 300 ₹1,050 |
| 10.00 | M&L for reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. | 3.5 | CUM | 5,000 ₹17,500 | 6,000 ₹21,000 | 4,877 ₹17,069.5 Lowest | 6,000 ₹21,000 | 8,500 ₹29,750 | 7,000 ₹24,500 |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
7 Jul 2025, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM-13/2025-26 ADDITION/ ALTERATION and SPECIAL REPAIR TO PRESTIGIOUS BUILDING NO P-163 AT CHANDIMANDIR MILITARY STATION UNDER GE CHANDIMANDIR
2025_MES_710968_1
CWE/CHM-13/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Chandimandir
Class B, Cate a(i)
9 documents required · 9 mandatory
₹2,000
GE Chandimandir
₹3.0 L
4 Sept 2025
28 May 2025
14 Jul 2025
29 May 2025
7 Jul 2025
18 Jun 2025
29 May 2025 - 3 Jun 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
Demolition of stone slabs of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. including complete removal of debris outside MD land complete all as specified and as directed by Engineer-in-Charge.
M&L for Non Skid ceramic coloured tiles, 8mm thick, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick cement mortar (1:6) screed bed for floor finishes complete all as specified and as directed by Engineer-in-Charge.
M&L for Glazed ceramic coloured printed tiles in vertical surfaces of size 300 x 450 x 7 mm set and jointed in neat cement slurry over 10 mm thick rendering in CM 1:4 for receiving the tiles complete all as specified and as directed by Engineer-in-Charge.
M&L for Glazed/ Matt finish coloured tiles of size 300 x 450 mm, 7-8 mm thick over for wall cladding purpose, colour and design of tiles as approved by GE over and including 10 mm thick rendering in CM 1:4 7 - 8 mm thick complete all as specified and as directed by Engineer-in-Charge.
M&L for Vitrified Ceramic tiles 10 mm thick, Dark shade (square/ rectangular), polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm screed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
All as per serial item no 6.00 here-in-above but as in skirting over and including 10 mm rendering in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for 16-18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl laid over including 20 mm thick screed bed in CM 1:4 in skirting/ dado complete all as specified and as directed by Engineer-in-Charge.
Demolition of reinforced concrete such as roofs, floors, beams, staircase, landing, chajjas, facia and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and as directed by Engineer-in-Charge.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200 mm thick (Horizontal or sloping) for flat rough finish surface of concrete complete all as specified and as directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10 mm dia & over, cut to length, bent to shape as required including cranking, bending specially for columns, hooking ends & binding with MS wire, annealed, not less than 0.9 mm dia or welding as required at site complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work masonry, built in cement mortar including dismantling all quions, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' bricks, straight/ curved on plan exceeding 6 metre mean radius built in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster on brick/ stone walls etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 10 mm thick rendering on fair face brick work or concrete surfaces in cement and sand mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 15 mm thick rendering in Cement and Sand mortar 1:4 over brick or concrete surfaces finished fair and even with using WPC complete all as specified and as directed by Engineer-in-Charge. Note:- (WPC shall be measured and paid separately)
M&L for Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth without using extra cement on ceiling in cement mortar 1:3 complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new surfaces of walls and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified and as directed by Engineer-in-Charge.
M&L preparation of new plastered surfaces of walls with wire brush and washing rubbing down with water, with Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including 1 mm thick wall care putty complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new surfaces of ceiling and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on New ceiling Surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour for One coats of oil bound distempering of approved manufacturer, of required shade and colour complete, as per manufacturer's specification for Old Wall Surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour for One coats of oil bound Distempering of approved manufacturer, of required shade and colour complete, as per manufacturer's specificationfor Old ceiling Surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of old decorated wall/ ceiling surfaces by removing spoiled paint/ scale dirt with wire brush or mechanical means/ grinder including washing rubbing and applying 1 mm thick wall care putty interior grade in smoothening the surfaces with sand papers and applying coat of wall primer and two coats of plastic emulsion on wall surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of undecorated wall surfaces for complete removing spoiled paint/ scale dirt with wire brush or mechanical means/ grinder including washing rubbing the surfaces and applying two coats of exterior emulsion paint as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge.
Preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old steel and iron surfaces of any description over 10 cm width or girth and one coat of synthetic enamelled paint on steel and iron surfaces over 10 cm width or girth including preparation of old surfaces complete all as specified and as directed by Engineer-in-Charge.
M&L for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats/ frames exceeding 1.5 Sqm but not exceeding 4.0 Sqm including shutters (without taking off shutters from the frames complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats/ frames not exceeding 1.5 Sqm including shutters (without taking off shutters from the frames) including grill etc complete all as specified and as directed by Engineer-in-Charge.
S&F of Stainless Steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed Stainless Steel wire staples complete all as specified and as directed by Engineer-in-Charge.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) Complete all as specified as per Manufacturer broucher.
S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
S&F 100 mm size butt hinges, medium weight stainless steel complete all as specified and as directed by Engineer-in-Charge.
S&F 150 mm size Aluminium barrel tower bolt of extruded section complete all as specified and as directed by Engineer-in-Charge.
S&F Aluminium handle, cast type, anodized, of size 150 mm, complete all as specified and as directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc. complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm dia PVC (Rain water pipes and sewage line) single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge.
S&F 75 mm bore PVC bends of any radius complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm bore PVC bends of any radius complete all as specified and as directed by Engineer-in-Charge.
S&F PVC SWR floor traps 75 mm dia with grating including jointing to waste pipe with solvent cement and setting/ fixed in cement concrete type 1:2:4, type B-1 complete all as specified and as directed by Engineer-in-Charge.
S&F PVC(SWR) gully traps125/110 mm dia setting and jointing with cement solvent complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Vitreous china squatting pan, ‘Orissa’ pattern, size 575 x 440 x 250 mm white, with integral foot rests (excluding flushing cistern and flush pipe), including 100 mm CI 'P' or 'S' trap set in and including concrete complete all as specified and as directed by Engineer-in-Charge. Make: CERA Cat Part No 'S3020105', Hindware Cat Part No '20042' and ESSCO Cat Part No 'ECS-WHT-451'
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), concealed type, white with PP soft Close Slim seat cover, Hinges, fixing accessories set size 340 x 515 x 405 mm, S or P trap, complete all as specified and as directed by Engineer-in-Charge. Make: Euronics Cat Part No 'C022-EWC', Hindware Cat Part No '20086' and ESSCO Cat Part No 'AIS-WHT-101955P180SPPSM'.
S&F in repair 10 litre capacity wall hang Dual flush Cistern with 39 mm drainage L Bend & Extension pipe with Gasket, O-ring & installation kit (Top cover with Legde) suitable for EWC and Orissa Pan including bracktes complete all as specified and as directed by Engineer-in-Charge. CERA Cat Part No 'B1020106', Hindware Cat Part No '516364' and Euronics Cat Part No 'EFT-D01'.
S&F in repair Vitreous China One Piece EWCs with Seat Cover and Twin Flush Fittings (Rimless Single Piece WC with UF soft cistern fitting, fixing accessories and Accessories set size 360 x 675 x 750 mm) complete all as specified and as directed by Engineer-in-Charge. Make: Kohler Cat Part No K-77739T-SL-0, Hindware Cat Part No '92562' and Jaguar Cat Part No 'ITS-WHT-89851S300PP'
S&F in repair of Table top wash basin snow white colour and size of 550 x 400 mm, including waste coupling 32 mm size half thread with 130 mm height & bottle trap 32mm size with 300 mm & 190 mm long wall connection pipes & wall flange complete all as specified and as directed by Engineer-in-Charge. Make: Jaguar Cat Part No 'JDS-WHM-25907N', CERA Cat Part No 'S2020153', Hindware Cat PArt No '91041'.
S&F in repair Vitreous china urinal snow white with EFS (Electronic Flushing system), Half stall type (Flat back large), size 320 x 300 x 525 mm with necessary brackets and including waste coupling 32 mm size, half thread with 130 mm height & bottle trap 32 mm size with 300 mm complete all as specified and as directed by Engineer-in-Charge. Make: Hindware Cat Part No '96004', Kohler Cat Part No 'K-21839T-2ER-0' and Euronics Cat Part Code 'KUF'
S&F in repair Vitreous china urinal, snow white (Back inlet) size 385 x 325 x 635 mm with fixing accessories, PVC connection and bottle trap (Providing and fixing by concern auth dealer/ manufacturer technician) complete all as specified and as directed by Engineer-in-Charge. Make: Jaquar Cat Part No - 'URS-WHT13253N', Kolar Cat Part No 'K-26474IN-ER-0' and Hindware Cat Part No '60010'
S&F in repair Push Cock/ Metropole Flush Valve, dual flow, 32 mm size (Concealed Body) with exposed shut off provision (2.0/4.0 Litres per flushing) complete all as specified and as directed by Engineer-in-Charge. Make: Jaquar Cat Part No 'PRS-CHR-073', Hindware Cat Part No 'F860077CP' and CERA Cat Part No 'F8010109'.
S&F in repair single lever Tall boy faucet, Brass, chromium plated, with 180 mm extension body fixed spout without popup waste system with 600 mm long braided hoses complete all as specified and as directed by Engineer-in-Charge. Make: Jaquar Cat Part No 'FLP-CHR5005BPM', Kohler Cat Part No 'K-22539IN-4-CP' and CERA Cat Part No 'F1005452'.
Supply and fixing in repair electronic sensor type Tall boy faucet, Brass, chromium plated, for wash basin (9V transformer & battery operated) (including machine and battery) complete all as specified and as directed by Engineer-in-Charge. Make: Jaquar Cat Part No 'SNR-CHR-91017', Hindware Cat Part No 'F240009CP' and Euronics Cat Part No 'ET12LE Auto Tap Long Body'.
S&F in repairs Bib tap, brass, chromium plated, fancy type, long body with wall flange, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, suitable for 15 mm bore pipe complete all as specified and as directed by Engineer-in-Charge. Make: Euronics Cat Part No 'RIV-1010R', Hindware Cat Part No 'F520004CP', and Jaquar Cat Part No 'KUP-CHR-35037PM'.
S&F stainless steel Grating 127 mm (5'') size complete all as specified and as directed by Engineer-in-Charge.
S&F PVC connections, 15 mm bore size, 450 mm length with PTMT nuts complete all as specified and as directed by Engineer-in-Charge.
S&F waste pipe of polyethylene of low or high density or PVC, 32 mm dia, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair Stainless steel single towel rail 600 mm long fixed with stainless steel screws with pvc rawl plugs complete all as specified and as directed by Engineer-in-Charge. Make: Kohler Cat Part No 'K-25065IN-CP', Jaquar Cat Part No 'AKPCHR-35711PS' and Euronics Cat Part No 'ACC04'.
Supply and fixing in repair Stainless steel towel ring fitted with Stainless steel screws and pvc rawl plugs complete all as specified and as directed by Engineer-in-Charge. Make: Kohler Cat Part No 'K-5631IN-CP', Jaquar Cat Part No 'CPACHR-1121RD' and Euronics Cat Part No 'ACC03'.
Supply and fixing in repair Stainless steel bathroom cloth Hooks, set of five hooks, solid body of best quality and fixed with brass screws with pvc rawl plugs complete all as specified and as directed by Engineer-in-Charge. Make: Kohler Cat Part No 'K-25073IN-CP', Jaquar Cat Part No 'ACNCHR-1161N' and Euronics Cat Part No 'ACC05'.
S&F as in repairs of Angle/ stop cock with wall flange, (desired distance between inlet end and lever 88 cm), cast copper alloy, chromium plated, fancy type, 15 mm bore, complete all as specified and as directed by Engineer-in-Charge. Make: Kohler Cat Part No 'K-23515IN-4-CP', Jaquar Cat Part No 'OPPCHR-15053PM' and Euronics Cat Part No ' RIV-1003R'.
S&F in repair CP Health faucet, Brass body with 8 mm dia, 1.20 metre long flexible tube in chrome finish & wall hook with N.R.V (Back flow preventer) for 15 mm bore with fittings, complete all as specified and as directed by Engineer-in-Charge. Make: Kohler Cat Part No '12925IN-RGD'. Jaquar Cat Part No ALD-SSF-577M and Hindware Cat Part No 'F160122CP'.
S&F in repair stainless steel toilet Roll holder with Flap with chromium plated screws and pvc rawl plugs complete all as specified and as directed by Engineer-in-Charge. Make: Euronics Cat Part No 'EPH04F'. Jaquar Cat Part No 'CPA-CHR-1153' and Kohler Cat Part No 'K-5633IN-CP'.
Taking up or down GI steel/ Kitek tubing 20 mm with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-charge.
Taking up or down GI steel/ Kitek tubing 15 mm with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-charge.
S&F 20 mm (outer dia) CPVC pipes, SDR 11 and Plain CPVC SDR 11 fittings, fixed on walls/ ceiling or laying in floors, complete all as specified and as directed by Engineer-in-Charge.
S&F 16 mm (outer dia) CPVC pipes, SDR 11 and Plain CPVC SDR 11 fittings, fixed on walls/ ceiling or laying in floors, complete all as specified and as directed by Engineer-in-Charge.
S&F Brass Elbow, 16 mm bore for CPVC Pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Brass Elbow, 20 mm bore for CPVC Pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Brass Tee, 16 mm bore, for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Brass Tee, 20 mm bore, for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Male Brass Threaded Adaptor, 16 mm bore (MTA/ MBTA) for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Male Brass Threaded Adaptor, 20 mm dia (MTA/ MBTA) for CPVC pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Female Brass Threaded adaptor, 16 mm bore (FTA/ FBTA) for CPVC Pipe, complete all as specified and as directed by Engineer-in-Charge.
S&F Female Brass Threaded adaptor, 20 mm bore (FTA/ FBTA) for CPVC Pipe, complete all as specified and as directed by Engineer-in-Charge.
Demolition of un-reinforced cement concrete exceeding 15 cm thick, any description and in any position not otherwise specifically provided for and removing all demolished material/ debris to 1.50 Km from the site and depositing where directed complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:5:10 (using 40 mm graded brick aggregates) as in sunken filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
M&L of water proofing of the sunken portion using a flexible two part acrylic polymer modified cementitious liquid appying water proofing coating "Sika TOP 107 seal flex IN" or equivalent product in Fosroc/ Dr. fixit/ Asian paint, which include the substrate preparation by mecahnical mean in odere to clean the area from dust/ loose particle., contamination etc. Repairing surface irrugularties damaged concrete surface crack, bugs holes or potholes in base slab. if any, with an acryclic polymer, sika latex SBR or eqivalent product in Fosroc/ Dr. fixit/ Asian paint. These substrate shall then be primed using high pressure water jet or other method, properly prewetted to SSD condition before coating. post substrate repair a primer coat shall be laid using a synthetic rubber emulsion based cememtious coating system, using brush or roller. (sika SBR latex tube added with OPC cement/ or water dilution as per PDS). Contd..
Contd.. once primer as applied, two coat of flexible two part acrylic polymer modified cememtious liquid appiled water profing coating using" Sika top 107 sealed flux IN" or equivalent make in Fosroc/ Dr. fixit/ Asian paint, shall be made including fibre mesh with a consumption rate 2 kg/sqm for two coats, which must meet the technical specification as under:- - Tensile strength > 1.5mm N/mm2 as per ASTM D412-92. Elongation of break> 105% as per astm d412-92. Hardness shore A> 40ASTM D2240:91
S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling existing water tank complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs, blankets, any thickness, including cover fillets complete all as specified and as directed by Engineer-in-Charge.
S&F false ceiling GI frame work for seamless ceiling comprising of GI perimetre channel 0.55 mm thick with two unequal angle of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exceeding 1.2 metre length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with clips of 10.5 mm fixed to intermediate channel with connecting clips accross the intermediate channel at 457 mm centre to centre complete all as specified and as directed by Engineer-in-Charge.
S&F Hangers 3 mm dia (up to1200 mm length) adjusting level fixed to roof slabs by means of ceilings cleats madeout of GI flat 40 x 3mm size 60 mm long and expansion hold fastenres 12.5 mm dia 40 mm long complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 5 mm thick PVC Sheet fillet of width 35 mm for wall panelling/ ceiling inclusive fixing on to wall/ ceiling to make PVC frame as per specification and drawing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Solid PVC Wall/ Ceiling lining consisting of 5mm thick plain colour PVC Sheet fixing at site on PVC frame as per specification drawing but wood grain printed PVC sheet used instead of plain colour sheet complete all as specified and as directed by Engineer-in-Charge.
M&L Solid 14 mm WPC Louvers wall panelling fixed to walls with necessary clip screw/ adhesive complete all as specified and as directed by Engineer-in-Charge.
M&L Anodised aluminium snap grid frame work for false ceiling including Hangers 3 mm dia. G.I. (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long complete all as specified and as directed by Engineer-in-Charge.
S&F 4mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and as directed by Engineer-in-Charge.
S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Note : (i) Glass/ wooden panel/ ACP sheet shall be measured and paid separately under respective items. (ii) Design will be as directed by Engineer in charge.
Supply and fixing 4.80 mm thick, frosted (figured) glass, ordinary quality, fixed to aluminum frame work in panels exceeding 0.5 Sqm in each pane, complete all as specified and as directed by Engineer-in-Charge.
S&F for 3 mm thick aluminium composite panel sheet (ACP) of any colour as approved by Engr-in-Charge complete all as specified and as directed by Engineer-in-Charge.
S&F for 200 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and as directed by Engineer-in-Charge.
S&F Butt hinges 100 mm size, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21 complete all as specified and as directed by Engineer-in-Charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing mortice lock, vertical type, mild steel, 4 levers, size 100 mm, brass body, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Door closer, aluminium (Extruded section body) body, hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg complete all as specified and as directed by Engineer-in-Charge.
S&F in repair double action floor spring, hydraulically regulated, made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made UPVC coloured sliding window three track made of extruded profile with wall thickness of 2.30 mm. Window profile with hollow section with multi chamber frame (88 mm x 52 mm), sliding sash (42 mm x 67 mm), sliding mesh sash (42 mm x 57 mm), sliding interlock (one vertical length in each shutter) (45.5 x 28 mm). Glazing bead (24.5mm x 16 mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage etc, making arrangement for fixing of hardware, EPDM gasket 1.2, 0.2mm thick galvanized steel frame (30mm x 18mm) 02 Nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to wall with 8mm x 100mm long fasteners. Hardware touch lock with zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, 8mm thick tinted float glass and required accessories complete all as specified and as directed by Engineer-in-Charge.
NOTE : (a) The unit rate quoted by the contractor include the cost of glass, wire cloth and includes all other connected accessories (b) Area of each window shall be exceeding 2.00 Sqm Each.
Demolition of un-reinforced cement concrete Nominal Mix Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed by Engineer-in-Charge.
M&L for precast cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) as in landings, cover slabs (for man holes etc.) chajjas, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 10 mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required. complete all as specified and as directed by Engineer-in-Charge.
S&F steel works as in rolled mild steel Plates (plain or chequered), channels. Square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment GDE Fe410-0 or Fe 310-O complete all as specified and as directed by Engineer-in-Charge.
S&F Steel works such as Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. GDE Fe410-W quality 'A' and complete all as specified and as directed by Engineer-in-Charge.
M&L preparation of new or previously untreated surfaces of steel of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of a red oxide zinc primer complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by Engineer-in-Charge.
M&L for 10 to 15 mm thick Industrial homogeneous vitrified heavy duty tile (parking Tiles), premium 1st quality of size not exceeding 0.36 sqm (any coloured as approved by Engr-in-charge/GE) over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregates) as in plinth protection complete all as specified and as directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge.
Taking down copper/ aluminum point wiring for (light, fan, socket point 5/15 amps) complete including fitting such as switches, ceiling rose, light fittings, sockets, bulb holder, ceiling roses, existing PVC/ Steel conduit etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular GI metal sunken box of thickness not less than 1.2 mm and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall, comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge.
NOTE for serial item no 111.00: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per site requirement etc. (ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing. (iii) Instruction for point wiring to be followed/compiled strictly as per Para 1 (a) to (q), Page Ser No 439 of SSR Part-II of 2020.
All as per serial item 111.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge.
All as per serial item No 111.00 here-in-before but for one socket outlet 3/ 5 pin, 5 amps on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per Serial item No 111.00 here-in-before but for one socket outlet 3/5 pin, 15 amps on independent board size of cable 2.5 sqmm for phase, neutral & 2.5 sqmm as earth wire complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F Modular socket outlet, 2 in 1, 3 pin 6 Amps, ISI marked, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet 2 in 1, 6/16 Amps, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular bell push, single pole, one module 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F electric bell, AC, 230 volt, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular fan regulator, suitable for BLDC fan as per make, single pole, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose, surface bakelite 65 x 50 mm dia three terminal complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder, insulated body, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed by Engineer-in-Charge.
S&F LED Lamp, Zero Watt, Red and Green fixed on holder complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing MCB, SP, 6 - 32 Amps, 'B' series, breaking cap 10KA, complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing MCB, SPN, 32 Amps,'B' series, breaking cap 10KA, 240V complete all as specified and as directed by Engineer-in-Charge.
S&F MCB, SPN, 40 to 63 Amp, 230 volts, having breaking capacity 10 KA "C" type complete all as specified and as directed by Engineer-in-Charge.
S&F MCCB 4 pole, 3 phase, 415 volts of capacity 125 Amps, 16 KA with adjustable thermal and magnetic release complete with proper cooper thimble connection complete all as specified and as directed by Engineer-in-Charge.
S&F in repair SLIM LED batten with polycarbonate housing and diffuser with elegantly designed end caps 1 x 20W, 220 V, AC connecting up with three core flexible of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair LED Luminaire 600 x 600 mm, 36 watt, 220V, Recessed type with high efficiency PMMA diffuser, soft, glare free light complete with driver holders and LED lamps suitable for roof ceiling including connecting up with driver with three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Exhaust vent F-06 size 150 mm rated voltage 240V, RPM 2100, air flow 320 m3/h, made of ABS plastic body, noise 35 db of make WadBros/ Rextan/ Asatbag complete all as specified and as directed by Engineer-in-Charge.
M&L for Cutting holes into or through brick or concrete wall surfaces for air ducting of exhaust fan in Circle/ square shape or as per site requirement of superficial area suitable for 150 mm exhaust fan including making good of disturbed area in cement mortar 1:3 or cement concrete 1:2:4, type B-l and cover hole as required complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in line duct fan WAD/ IL Series connected to the duct then install the fan unit on the base as per model No WAD IL 15 of make WadBros or equivalent in Rextan/ Asatbag, fan size 150 mm rated voltage 230V, frequency 50 HZ air flow 500 m3/h including duct model PVC pipe size 6" -12 RM, diffuser 6"-3 NOs and new protection grill 6"-1 No complete all as specified and as directed by Engineer-in-Charge.
Disconnecting and taking down carefully copper/ aluminium sub main wiring complete, including existing batten/ conduit etc., removing materials and making good disturbed surfaces of wall, floors, etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.0 sqmm, LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 4.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 6.0 sqmm, LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 20 mm/ appropriate dia with accessories and fittings and one run of 6.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L for Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 10.0 sqmm, LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 10.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Note for serial item no 135.00 to 137.00: 1. Two runs of cable, one run of earth wire and one run of PVC non mettalic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe.
M&L for Sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 16.0 sqmm, LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 32 mm/ appropriate dia with accessories and fittings and one run of 16.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L for Sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 25.0 sqmm, LT, 1100V grade, drawn through and including adequate sizes PVC non metallic conduit of 32 mm/ appropriate dia with accessories and fittings and one run of 25.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Note for serial item no 138.00 & 139.00: 1. Four runs of cable, one run of earth wire and one run of PVC non mettalic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe.
Supply, installation, testing and commisioning of LT panel electrical board, floor mounted, cubical type, indoor type, aesthetically designed fabricated out of 2 mm thick outer CRCA sheet and 2 mm thick inner CRCA sheet with front and rear opening conforming to IS-8623 and including of bus bar chamber, continuous GI strip, earth bus bar, din rail channels, cable alley, danger notice board including powder coated rust proof paint connecting incomming and outgoing cable connections with suitable lugs nut bolts washers and cable glands, pre-wired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:-
(a) Copper bus bar of suitable size mounted on PVC insulators - 4 strips (b) Phase indicating lamps (RYB)- 3 Nos (c) Multifunction meter for measuring ampere, voltage, frequency etc complete - 1 No (d) ACB 630 Amps 70 KA 4 pole with Microprocessor thermal and magnatic release - 1 No. for incomming (e) MCCB, 250 Amps, 25 KA, 4 pole with thermal and magnatic release - 03 No. for outgoing (f) MCCB 63 Amps, 4 pole, 25 KA with Microprocessor thermal and magnatic release - 3 No outgoing (g) Change over switch 400 Amps, 4 pole, on load type -1 Nos (h) MCB SPN 32 Amps -3 Nos
Supply, installation, testing and commisioning of LT panel electrical board, floor mounted, cubical type, indoor type, aesthetically designed fabricated out of 2 mm thick outer CRCA sheet and 2 mm thick inner CRCA sheet with front and rear opening conforming to IS-8623 and including of bus bar chamber, continuous GI strip, earth bus bar, din rail channels, cable alley, danger notice board including powder coated rust proof paint connecting incomming and outgoing cable connections with suitable lugs nut bolts washers and cable glands, pre-wired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:-
(a) Copper bus bar of suitable size mounted on PVC insulators - 4 strips (b) Phase indicating lamps (RYB)- 3 Nos (c) Multifunction meter for measuring ampere, voltage, frequency etc complete - 1 No (d) MCCB 400 Amps, 50 KA, 4 pole with Microprocessor thermal and magnatic release - 1 No. for incomming (e) MCCB 200 Amps 25 KA 3 pole with thermal and magnatic release - 4 No. for outgoing (f) MCCB 63 Amps 3pole 25 KA with Microprocessor thermal and magnatic release -3 No outgoing (g) Spare for Housing MCCB -1 Nos (h) MCB SPN 32 Amps -3 Nos
S&F MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with Copper bus bar 200 Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosures for MCB DB, SPN, 240 volts, 8 way, double door fitted with bus bar, neutral link, earth bar and din rail complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosure, SPN, with a two pin and earth plug socket complete including with 32 Amp MCB ‘C’ single pole 240 volt complete all as specified and as directed by Engineer-in-Charge.
S&F vertical TPN distribution board, double door, flush mounting with provision for MCCBs incommer upto 125 Amp, 415 volts & outgoing 4 way having IP43 protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling fan, 1200 mm sweep, Energy Saving model, Pearl white/ white in colour 350 RPM, 220 volt 50 Hz complete with canopy, down rod. Fan blade, Fan hook box type for hanging with complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing exhuast fan, 450 mm, operating voltage at 220-240 V with all mounting accessories such as louvers etc., Cutting hole for air ducting for exhaust fan in Circle/ square shape or as per site requirement into or through concrete walls built in cement mortar of superficial area suitable for 450 mm exhaust fan including making good of disturbed area in cement mortar 1:3 or cement concrete 1:2:4, type B-l and cover hole as required complete all as specified and as directed by Engineer-in-Charge. Note :- Louvers will be same as per original manufacturer of exhaust fan.
Supply and fixing heavy duty air circulator wall mounted fan, sweep, 600 mm, three blades, alloy steel operating voltage at 220-240V with all mounting accessories complete all as specified and as directed by Engineer-in-Charge.
Taking down fan ceiling/ exhaust/ wall fan, dismatling blades and removing fan and blades to store for safe custody complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully distribution board, any type by unscrewing from boards fitting and fixture such as MCB DB, of any size complete with all MCCB's, MCB's etc and removing from site, complete all as specified and as directed by Engineer-in-Charge.
Taking down Old U/S LT Panel after disconnection of power supply complete all as specified and as directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal gound level connected to galvanized iron strip of size 32 x 6 mm dia bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 connected to test point including testing complete including necessary excavation and earth work in any type of soil, PCC 1:3:6 type C-1, MS chamber, funnel, watering pipe 20 mm dia, medium grade, protection pipe 40 mm dia GI pipe, light grade of length upto test point, pre-cast RCC cover incl taking down old earthing complete all as directed by Engr-in-Charge.
Note: The unit rate includes for protection pipe 40 mm dia and GI Strip from top of the earth plate upto 7.5 metre length.
M/s Om parkash (BID ID -3342318)
K L Kataria and Sons (BID ID -3350275)
Sham Sunder Bansal (BID ID -3350021)
M/S SEWA AND SERVE BUILDERS (BID ID -3344598)
B.K.ASSOCIATES (BID ID -3347748)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .