Tender Value
₹4.7 L
EMD Value
₹6,000
Closing Date
24 Apr 2024, 5:00 pmClosed
Staff Officer EnM SECL Sohagpur Area
Staff Officer EnM SECL Sohagpur Area Dhanpuri Distt Shahdol MP 9424141331
Repairing Rewinding of MS Andrew Yule make TSU, serial no. 1697, 315 KVA, Primary voltage 3.3 KV, Secondary voltage 550 V transformer of Bangwar UG mines and Repairing Rewinding of 02 Nos. of TSU, 01 no. of Mine Line make TSU, serial no.377 and 01no.
2024_SECL_306263_1
SECL/SGP/EnM/eT/24-25/231 Dtd 04.04.2024
Open Tender
Miscellaneous Works
Item Rate
45 days
Bangwar UG AND Damini UG Sohagpur Area
As per NIT and Tender documents
4 documents required · 4 mandatory
₹6,000
30 Sept 2024
5 Apr 2024
26 Apr 2024
5 Apr 2024
24 Apr 2024
6 Apr 2024
5 Apr 2024 - 13 Apr 2024
Amount
Repairing/Rewinding of M/S Andrew Yule make TSU, serial no. 1697, 315 KVA, Primary voltage 3.3 KV, Secondary voltage 550 V transformer of Bangwar UG mines & Repairing/ Rewinding of 02 Nos. of TSU, 01 no. of Mine Line make TSU, serial no. 377 and 01 no. of M/S Andrew Yule make TSU, serial no. 1142, 315 KVA, Primary voltage 3.3 KV, Secondary voltage 550 V transformer of Damini UG mines of ABD sub area of Sohagpur Area.
TSU of Bangwar UG- 99.96% Electrolytic grade copper conductor TPC for Replacement of old & damaged primary winding. (Less copper scrap Material value of the same Qty.)
99.96% Electrolytic grade copper conductor TPC for Replacement of old & damaged Secondary winding. (Less copper scrap Material value of the same Qty.)
Other insulating material for coil formation, overall insulation Heating & Varnish Class-H
Labour Charges
HT & LT Bush with Stud
Repairer’s profit
Transformer of Damini UG - 99.96% electrolytic grade copper conductor TPC for replacement of old and damaged primary winding.(Less copper scrap Material value of the same Qty.)
Re-insulation of existing copper conductor of secondary winding with double Norex insulation.(Less copper scrap Material value of the same Qty.)
Other insulating material for coil formation, overall insulation, heating, and varnish class H
Labour charges
Repairer’s profit
Total impact of GST for the purpose of CTC
SURESH ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .