| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAdmitted-Finance | ₹8.3 L | L1 | Admitted-Finance |
| 2 | L2₹8.4 LAdmitted-Finance | ₹8.4 L | L2 | Admitted-Finance |
| 3 | L3₹8.4 LAdmitted-Finance | ₹8.4 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SAFELINE ELECTRICALS L3 | P. K. POWER SOLUTIONS L2 | PRITHVI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Testing of 33/11 KV Incoming and Outgoing Feeder Panels installed at different 33/11 KV Sub-Station under EDD-33 KV & PR Vertical, Ayodhya Dham, Ayodhya including testing of CTR both by primary injection work includes cleaning and adjustments of relay contacts & springs, checking of closing and tripping of breakers on remote/local and protection trip command through CT (by means of primary injection) & measuring 11 KV and 33 KV Feefer Panel earthing. | 110 | Nos. | 3,025 ₹3.3 L | 3,010 ₹3.3 L | 3,000 ₹3.3 L |
| 2.00 | Testing of 5/8/10 MVA power transformer installed a various installed at 33/11 KV Sub-Station under EDD-33 KV & PR Vertical Ayodhya including following tested-
a) No load/ratio test.
b) Short Circuit test
c) Magnetization Current test.
d) Magnetic Balance test.
e) Insulation test by meggar.
f) Buchholz, OTI/WTI circuit test. | 24 | Nos. | 16,100 ₹3.9 L | 16,110 ₹3.9 L | 16,000 ₹3.8 L |
| 3.00 | Providing 3 Phase DG set on vehicle for availability of 3 phase supply for testing of 33/11 KV Sub-Station. Vehicle with DG set & operator will be made available for 12 hrs. in each job by the contractor. | 12 | Nos. | 10,100 ₹1.2 L | 10,050 ₹1.2 L | 10,000 ₹1.2 L |
Tender Value
₹8.4 L
EMD Value
₹8,400
Closing Date
16 Mar 2026, 5:00 pmClosed
SE, EDC, Ayodhya
SE, EDC civil lines, Ayodhya.
122 H(F)(W)/2025-26
2026_MVVNL_1121666_1
122 H(F)(W)/2025-26
Open Tender
Electrical Works
Ayodhya
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE, EDC, Ayodhya
₹8,400
19 Mar 2026
6 Mar 2026
17 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
Testing of 33/11 KV Incoming and Outgoing Feeder Panels installed at different 33/11 KV Sub-Station under EDD-33 KV & PR Vertical, Ayodhya Dham, Ayodhya including testing of CTR both by primary injection work includes cleaning and adjustments of relay contacts & springs, checking of closing and tripping of breakers on remote/local and protection trip command through CT (by means of primary injection) & measuring 11 KV and 33 KV Feefer Panel earthing.
Testing of 5/8/10 MVA power transformer installed a various installed at 33/11 KV Sub-Station under EDD-33 KV & PR Vertical Ayodhya including following tested- a) No load/ratio test. b) Short Circuit test c) Magnetization Current test. d) Magnetic Balance test. e) Insulation test by meggar. f) Buchholz, OTI/WTI circuit test.
Providing 3 Phase DG set on vehicle for availability of 3 phase supply for testing of 33/11 KV Sub-Station. Vehicle with DG set & operator will be made available for 12 hrs. in each job by the contractor.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
TenderForm.pdf
Tender Documents • 0.93 MB
BOQ_2089501.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid