SE,EUDC-VII,Ciss-Gomti,LESA
33/11 K.V. Substation,sct-5D,Vrandavan Yojna,LESA, Lucknow.
FOR THE WORK OF Different type work of Repairing and Maintenance at 33/11 KV S/S Vrindavan under jurisdiction of E.E., EUDD., Vrindavan, LESA, Lucknow
2019_MVVNL_417467_1
57/EUDC-VII/LESA/2019-20
Open Tender
Miscellaneous Works
90 days
Lucknow
as per tender docuements
2 documents required · 2 mandatory
₹1,180
A/CNo- 1277784945,IFSC Code-CBIN0280140
₹10,000
Yes
31 Jan 2020
28 Dec 2019
10 Jan 2020
28 Dec 2019
9 Jan 2020
28 Dec 2019
Amount
Safe carriage, loading-unloading with proper stacking of following material from ESC-Daliganj to Work Site/JE -Dump Store
PCC Pole 8.5/9 Mtr long
S.T.P Pole 9/11 Mtr long
Different maintenance material Cable, Joint Kit, PVC Cable, ACSR wire, Insulators, Transformer oil, ABC cable, Fuse units, Fuse wire, backentry, spring contacts etc.
11 KV HT XLPE cable 3x185 sqmm., 3x120 sqmm., 3x240sqmm. etc.
Fabrication and erection of missing/damaged wiremess fencing 02 mtr. Height with gate and retaining wall including grouting of febricated MS angle 65x65x6 mmsq support and its painting as per specification.
Repairing of damaged massonery transformer plinth of size as per requirement at site to maintain the height of 1.5 mtr brick blast, filling of sand in the hollow space, plastering of surface in ratio 1:4:6 and top of plinth 4" thickness concealling. (Including all materials and labour and T&P.)
Repairing of damaged / rusted steel tubular pole by digging of pit up to 2" for proper position putting 3 nos. angle from of size 35x35x6 sqmm 3 nos angle around the damaged part of pole and welding properly and also grouting and plastering 300 mm with cement concrets.
Erection of Sub-Station type Double pole on 9/11 meter long S.T. Pole along with fixing of necessary clamp/accessoires required including fixing of straight M.S. 100x50mm. Top channel 125x65x6mm (2240mm long) one no. Dropper channel 100x50mm(2028mm long)/Angle 100x50 mm 02 nos with arrangement of fixing of 03 nos. Pin insulator including Sub-Station base angle of 65x65x6mm (2250mm)channel 02 nos. earthing it properly as per RESPO specification.
Laying of 11 KV 3x185, 3X120, 3X240Sqmm. XLPE cable with drilling machine as per norms of UPPCL.
Erection, of single pole PCC/ST Pole 11 Mtr long with all accessories.
Supply and repairing/replacement of damaged tailless fuse unit/materials on LT distribution piller box with clamping lug of required size of LT PVC.
500 Amp., 600 Volts.
300 Amp., 600 Volts.
Resagging of existing LT/HT line opening of ABC on service point and opening of cousumers service cable after re-sagging of ABC re-connection of consumers service cable. (In breakdown time man power has been provided 24 hours.)
Providing chemical earthing of existing 400/630 KVA transformer by boaring & lowering 20" electrode and put chemical for improve earthing resistance below than 1 OHM and connecting of transformer body and neutral with GI Strip.
Arresting oil leackage from transformer by replacement of oilseal, corksheet and packing of transformer also replacement of bushing rod 250/400 KVA transformer along with L-piece.
Grouting and nozzeling of stay set complete 16x1800 mm. sq. with cement concreat sand, brick, blast.
Re-grouting cable and laying cable during breakdown period/ faults on main road etc.
Cutting of tree branches and clear form the existing HT/LT line to reduce the tripping/breakdown and losses.
Construction of ring main unit (RMU) to provide ring system and backfeed system to on feeder to another feeder to mainain 24 hours supply.
Top-up distiled water in battery bank time to time and maintain DC supply for healthy tripping also maintained water density.
Supply and fixing of DTS name plates on distribution transformers of size 24x24 mm with radium colour along with clamps.
Supply and fixing of Feeders (I/C cable & O/G cable) name plates on double pole and four pole of size 24x24 mm with radium colour along with clamps.
Shifting of transformer from one plinth to another plinth and installed trolly with the help of crane during repairing of plinth.