| 1 | L1₹48.4 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹48.4 L | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹51.4 L+₹3.0 L (6.25%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | ₹51.4 L+₹3.0 L (6.25%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹52.2 L+₹3.8 L (7.94%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹52.2 L+₹3.8 L (7.94%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹52.7 L+₹4.3 L (8.83%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹52.7 L+₹4.3 L (8.83%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹53.1 L+₹4.7 L (9.74%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | ₹53.1 L+₹4.7 L (9.74%) | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Nov 2024, 6:00 pmClosed
GE AF CHABUA
Office of GE AF Chabua, PIN-786102
As per BOQ details
2024_MES_680813_1
606/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chabua
As Per tender document
8 documents required · 8 mandatory
₹500
GE AF CHABUA
₹90,000
Yes
12 Dec 2024
23 Oct 2024
27 Nov 2024
23 Oct 2024
25 Nov 2024
18 Nov 2024
Amount
Inspection,testing servicing, & overhauling to HT VCB 11 KV upto 800Amp Indoor type of any make installed at MRS Chabua , taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/servicing and its testing on full load complete all as specified and directed. Note: (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. (ii) The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as ‘supply only’(.iii) Servicing /repair will be carried out OEM/Authorised Deler (iv)All measuring equipments and T&P required shall be arranged by the contractor (iv)Servicing will be done in every 06 month or as directed by Engr-in-Charge. (v) The rates quoted by the contractor shall also include the cost of replacement of worn out nuts, bolts, gaskets, A-grade greasing and oiling of moving parts and refixing the same. Inspection,testing servicing, & overhauling carried out comprising of the following all as directed by Eng-in- charge :- (a) Preliminary inspection of 11 KV VCB for any defects. (b)Testing of CTs:- (i) IR test (ii) Ratio test (iii) Winding resistance test (c) Testing of PTs:- (i) IR test (ii) Ratio test (iii) Polarity test. (d) Servicing on MV Switch gear panels :- (i) Cleaning panel (ii) checking the condition of support insulators and other accessories (iii) IR test (iv) HV test. (e) Servicing on VCBs :- (i) IR test (ii) Timing test. (iii) CRM test (iv) HV test (f) Replacement of spares. (g) Relay testing and calibration
Inspection,testing servicing, & overhauling to HT VCB 33 KV 1250 Amp 25 KA out door of any make installed at MRS Chabua , taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/servicing and its testing on full load complete all as specified and directed. Note: (i) The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. (ii) The new replaced parts shall be measured and paid for separately under appropriate item of BOQ as ‘supply only’(.iii) Servicing /repair will be carried out OEM/Authorised Deler (iv)All measuring equipments and T&P required shall be arranged by the contractor (iv)Servicing will be done in every 06 month or as directed by Engr-in-Charge.. (v) The rates quoted by the contractor shall also include the cost of replacement of worn out nuts, bolts, gaskets, A-grade greasing and oiling of moving parts and refixing the same. Inspection,testing servicing, & overhauling carried out comprising of the following all as directed by Eng-in- charge :- (a) Preliminary inspection of 33 KV VCB for any defects. (b)Testing of CTs:- (i) IR test (ii) Ratio test (iii) Winding resistance test (c) Testing of PTs:- (i) IR test (ii) Ratio test (iii) Polarity test. (d) Servicing on MV Switch gear panels :- (i) Cleaning panel (ii) checking the condition of support insulators and other accessories (iii) IR test (iv) HV test. (e) Servicing on VCBs :- (i) IR test (ii) Timing test. (iii) CRM test (iv) HV test (f) Servicing of spares. (g) Relay testing and calibration
Digital volt meter (1 Phase) suitable for 11 KV VCB of rating 400/630/800 Volts as per existing make and model .
Digital amp meter (1 Phase) suitable for 11 VCB of rating 400/630/800 amps as per existing make and model .
Charging motor suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model .
Vacuum interrupter suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
Tripping push button suitable for 11KV VCB of rating 400/630/800 Amps as per existing make and model
Single unit resin cast type current Transformer of rating 11 KV, ratio 50-25/5-5A, burden 5P10 for protection and 10VA for metering
Single unit resin cast type potential Transformer of rating 11 KV, ratio 11KV/ √3/110V/√3 burden 100VA, pistol type
Relay suitable for 11 KV VCB of rating 400/630/800 amps
Relay suitable for 33 KV control panel
Limit switch suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
11 KV PT HRC fuse AVT type 0.5 to 6 Amp and 2.5 KV to 36 KV as per existing make and model
Fixed contact block suitable for 11 KV VCB for rating 400/630/800 Amps as per existing make and model
Moving contact block suitable for 11 KV VCB as per existing make and model
Closing coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model
Tripping coil assembly 24 Volts DC suitable for 11 KV VCB as per existing make and model
Mechanical Castle interlock assembly with Key suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
Busbar Spout suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
Vaccum spout suitable for 11 KV VCB of rating 400/630/800 Amps as per existing make and model
Material and labour for Servicing and maintenance of transformer 11/.433 KV indoor / outdoor type of capacity 63 KVA to 160 KVA at site under the AOR of GE AF Chabua in any position i.e pole mounted/ plinth mounted, of any capacity (except major repair /rewinding), including partial decanning of transformer oil, opening of top cover, disconnecting of internal connections, LT / HT bushes, Tap changer etc, replacement of unserviceable items, top cover gasket of rubber cork sheet, tap changer etc complete all as specifed and as directed. Note :- (i) All tools and plant including magger, oil testing machine, acidity test kit, other testing equipment and unloading all equipements such as crane/Hydra, chain pulley will be arranged by the contractor and No extra charges shall be paid to the contractor. (ii) One transformer will be catered as on Job. (iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 6 hours from the time of intimitation in day or night in the stn, failing this a panelty of Rs 3000/- per complaint / fault will be imposed on the contractor from contractor dues.(iv) Minimun one transformer shall be produce at a time to the contractor for repair. Contractor will not be demand all transformer in one visit or at a time. transformer will be provided as and when repair work required/fault occured during the complete period of contract. Visit and repair charges of electrician and helper are included in the quoted rate. No extra charges shall be paid to the contractor. (v) Strip opening of transformer for detecting fault shall be included in the quoted rate. No extra amount shall be paid to the contractor. Note:- (i) Minor Gasket, rubber washer, Copper / Aluminum thimble, HT/ LT Tape, nuts, bolts and washer for any size of transformer will be included in the quoted rate . No extra amount shall be paid to the contractor for the same. (ii) LT/ HT stud/spindle, transformer oil, dehydration of transformer oil and insulator and other major items shall be measured and paid seperately.
All as per srl item No 21 here in before but 200 KVA to 1000 KVA.
Material and labour for disconnecting the transformer (Indoor/ Outdoor type) from Plinth/Pole Mounted any type/size and capacity under the AOR GE (AF) Chabua from all connection primary and secondary with earthing and shifting the same transformer to the other location/store yard/Power house as per required or installed to other location including all necessary all connection complete all as specified and as directed. Note :- All tools, plants and vehicle for lifting and shifting the transformer shall be arranged by the contractor and not extra payment shall be paid to the contractor for the same.
Material and labour for disconnecting the transformer (Indoor/ Outdoor type) from Plinth/Pole mounted from all connection primary and secondary with earthing after faulty transformer loading on vehicle and carrying to workshop for repair and replacement of old worn out and u/s items as well as winding etc including unloading at the workshop capacity of transformer 63 KVA to 315 KVA. Note :- All tools, plants and vehicle for lifting and shifting the transformer shall be arranged by the contractor and not extra payment shall be paid to the contractor for the same.
All as per srl item No 24 here in before but 500 KVA to 1000 KVA.
M&L for dismantling the top cover of the defective transformer of capacity 63 KVA to 125KVA 11/.433KV after drained out the existing oil in a separate clean container and disconnecting the all internal connection, taking out the HV/ LV core assembly and Magger the winding for identifying the fault/defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer, cleaning the transformer chamber (body) inside and out side thoroughly with emery paper and cloth than checking the other worn-out parts and insulation materials such as glass tube, bakelight tube, tap changer,glass tape, pre-compressed board, crape paper,craft paper, pressphan paper, cotton tape, varnish etc , HV/LV coils silicon stamping and other connected items such as tap-changer, breather assembly, damage HV/LV bushes, stud, oil seal, Gas kit and replacement of all burn out parts and insulation material with new ones by drying and baking of Insulating material in heating chamber in adequate temprature. Reassenbling the transformer and made connection of LV/HV side with help of soldering.Testing of transformer after reassembly complete on No load at wkshop and on load at site all as specified and directed. Note :- (i) Winding wire/strip of HV/LV coils, transformer oil and other spare pafrts shall be measured & paid seperately on relevant items of the schedule. (ii) Gasket, Copper / Aluminum thimble, HT/ LT Tape, insulation materials such as glass tube, bakelight tube, tap changer,glass tape , pre-compressed board, crape paper,craft paper, pressphan paper, cotton tape, varnish etc , HV/LV coils silicon stamping and other connected items, HV/LV coils silicon stamping for any size of transformer will be included in the quoted rate . No extra amount shall be paid to the contractor for the same. (iii) The transformer will be opened and reassembled in presence of Egnr-in-charge / JE in charge.
All as per srl item No 26 here in before but 160 KVA to 200 KVA.
All as per srl item No 26 here in before but 250 KVA to 315KVA.
All as per srl item No 26 here in before but 500 KVA To 1000 KVA.
Supply and fix in repair 33 KV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
Supply and fix in repair 11 kV Lightning arresters expulsion type with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed at site.
M&L in repair triple pole mechanical operated , mounted on insulator with operating mechanisam worked from ground level for current rating 400 amps amps suitable for 33000 volts complete all as specified and directed.
M&L in repair triple pole mechanical operated , mounted on insulator with operating mechanisam worked from ground level for current rating 400 amps amps suitable for 11000 volts complete all as specified and directed.
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories complete suitable for 3 core XLPE aromoured aluminium conductor cable of size 95 sq mm.
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 95 sq mm.
Supply and fix in repair of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories complete suitable for 3 core XLPE aromoured aluminium conductor cable of size 240 sq mm.
Supply and fix in repair of cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE aromoured aluminium conductor cable of size 240 sq mm.
Supply and fix in repair of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm.
M&L for drop out fuse suitable for 33000 volts grade complete all as specified and directed.
M&L for drop out fuse single pole suitable for 11000 volts grade upto 50 amps complete all as specified and directed.
Attending of 33/11 KV HT breakdown and finding the fault in transformers, VCBs,HT UG cables, CTs,PTs, lighting arrestor, insulator etc by highly skilled mechanic to replace any sparss related breakdown complete all as specified and directed at site. (a) a sum of Rs 4000.00/day will be recovered in case of not attend break down by service Engineer and not rectified defect with in 24 Hrs. (b) Spars will be paid separately under relative items. (c) Labour to be included the quoted rates
Supply and stringing in repair ACSR conductor of any size for HT/LT over head line as directed including fixing to insulators with proper size of binding wire complete.
All as per item 45 but GI wire 4 mm dia complete.
M & L in repairs for Cross arms/Chequred plate, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminum paint over a coat of red oxide primer, complete all as directed.
M&L for replacement of pin type insulator porcelain, votreous, white, brown or green insulator including one galvnised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for working pressure 33000 volts grade complete all as specified and directed.
M&L for replacement of disc type insulator, porcelain, vitreous and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 33000 volts complete all as specified and directed.
M&L for replacement of pin type insulator porcelain, votreous, white, brown or green insulator including one galvnised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for working pressure 11000 volts grade complete all as specified and directed.
M&L for replacement of disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white,brown or green single disc assy for tension with tension clamps for conductors,working pressure 11000 volts complete all as specified and directed.
Supply and fixing in repair steel tubes, galvanised, light grade, ISI marked 80 mm bore for protection of cable under floor, road and on wall complete.
Supply and fixing in repair steel tubes, galvanised, light grade, ISI marked 100 mm bore for protection of cable under floor, road and on wall complete.
M&L for painting of HT tubular poles up to 11 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos all as specified and directed at site.
Material and labour, painting of two pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour, painting of three pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour, painting of four pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour, painting of six pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
Material and labour, painting of eight pole structure consisting of 11m long steel tubular poles including cross arms, clamps of any length and shape, for HT over head line, with two coats of aluminium paint including preparation of the existing surface including marking pole numbers in a 20cm dia circle and marking bottom of pole to 1.5m height, complete all as specified and directed.
M&L for spray painting of transformer preparation of old painted surfaces of steel body by brushing/cleaning stain, greasy spots with thinner outside of transformer indoor/outdoor type capacity 63 KVA to 160 KVA to match with existing colour as per direction by Engr-in-Charge.
All as per ser item No 59 above nere-in-before but capacity of 200 KVA to 315 KVA
All as per ser item No 59 above nere-in-before but capacity of 500 KVA to 630 KVA
All as per ser item No 59 above nere-in-before but capacity of 800/1000 KVA
All as per ser item No 59 above nere-in-before but capacity of 2.5 MVA Power Transformer.
All as per ser item No 59 above nere-in-before but capacity of 7.5 MVA Power Transformer.
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on HT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
M&L for dehydration with hot filteration plant of old transformer oil at different locations, after filteration, Di electric strength shall not be less than 60 KV in 2.5 mm gap electrode, complete all as specified and as directed. The contractor shall submit necessary Test Report for Di electric strength before dehyderation as well as after dehyderation as per relevant IS. The contractor's quoted rates shall also be declered to include for this element. Note:- (i) Toping up of transformer Oil during the dehyderation shall be measured and paid separately on relevant items of schedule. (ii) The contractor must have own one dehydrated hot vacuum, filtration plant with minimum 1000 liter per hour capacity transformer oilfFiltration plant with a provision of oil test set for immediate showing of result. (iii) The plant must have provision of on load filtration. Dehydration and filteration of transformer oil at site by using dehydrating and filteration machine to be carried out till time, dielectric strength reached to min 60 KV complete all as specified and directed. (ivThe transformer dehydration machine shall be arrange/brought by contractor at site for which and no extra amount shall be paid to the contractor.
Supply and filling, transformer oil EHV grade as per IS-335 of 1993 Part-II for top up / replacment as per direction by Engr-in-Charge.
M & L for rewinding HT/LV coils of transformer by using proper size super enameld copper wire suitable for working voltage 11 KV/0.433 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed at site. NOTE :- i). Oil filtration,supply of new oil will be measured separately. ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted. iii). The rate for taking out,refixing after repair,both side transportation, lifting /unloading of voltage stabilizer/isolation transformer by crane /manual should be deemed to include in the rate quoted.
Supply and fix in replacement Tap changer assy of 11/0.433 KV transformer 500 to 1000 KVA including replacing worn out connection sleeves, insulated plates, nut, bolts & washers and testing after replacement complete all as specified and directed.
S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 63 KVA to 315 KVA 11000/433V complete all as specified and directed.
S & F in repairs LT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 500 KVA to 1000 KVA 11000/433V complete all as specified and directed.
S & F in repairs HT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 63 KVA to 315 KVA 11000/433V complete all as specified and directed.
S & F in repairs HT bushing with brass stud, packing ,nut, bolt, washers etc suitable for 500 KVA to 1000 KVA 11000/433V complete all as specified and directed.
S & f in repair Transformer top cover gasket/cock sheet suitable for 63 KVA to 160 KVA transformer complete all as specified and directed at site.
S & f in repair Transformer top cover gasket/cock sheet suitable for 200 KVA to 315 KVA transformer complete all as specified and directed at site.
S & f in repair Transformer top cover gasket/cock sheet suitable for 500 KVA to 1000 KVA transformer complete all as specified and directed at site.
S & F in repairs bushing with brass stud, packing ,nut, washers etc on primary side suitable for 7.5 MVA, primary side complete all as specified and directed.
Supply and fixing in repalcement of heavy duty breather assembly of capacity 0.5 kg with silica gel cristal complete all as specified.
Supply and filling silica gel cristal in to breather assembly complete all as specified and directed at site.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique/Manual and necessary machine suitable for 80/100 mm GI pipe complete Existing all as specified and directed at site
Supply and fix in repair of LED indication lamp for VCB control panel complete all as specified and directed at site.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm bore pipe.
M&L for spreading of graded crashed aggregate 40mm nominal size to a true surface and leveled in layers not exc. 20 cm thick for switch yard complete all as specified and directed by Engr-in-Charge.
Supply installation,testing & commissioning of battery bank of 200 AH ,110 V DC(2VX55 nos) maintenance free VRLA battery bank with complete all as specified and directed by Engr-in-Charge. Make: AMARA RAJA / EXIDE / Soft Power Controls
Supply and fixing 12V X 2 Nos 150 AH INTT3000 battery for 5 KVA UPS inverter and arrange properly with connecting leads inside battery rack suitable for inverter including taking down old u/s complete all as specified and directed by Engineer-in-Charge. Make: AMARA RAJA / EXIDE / AMARON
Supply installation, testing & Commissioning of Battery charger of INPUT : 415 V AC,output 35 A 110v float cum bost charging sutaible to charge 200 AH 110 V battery Bannk , along with DCDB , made of carbon steel duly powder coated finish,contineously welded and ground smooth, concealed door hinges, locking mechanism with key/padlocking handle, oil resistant gasket including taking down old rusted unserviceable battery caharger complete all as specified and directed by Engr-in-Charge. Make: AMARA RAJA / EXIDE / Soft Power Controls
Supply Installation of 5kV heavy duty UPS inverter 24 V ,JM SW 3500+ and arrange properly with connecting leads inside battery rack suitable for inverter including taking down old u/s complete all as specified and directed by Engineer-in-Charge. Make: MICROTEC/ EXIDE / AMARON
M&L for Callibration of VCB Relay by injection high Voltage through CTS Checking the over load system of VCB upto 90% rated load and artificial fault creation and setting of relay by 10 to 15 % of rated load and artificial fault creation and setting of relay by 10 to 15 % of raed load removal u/s overload and earth fault relay including connection with power pack opening out the trolly checking the operation of VCb mechanically anf electrically through shunt trip coil including energizing of springs automatically including checking of TNC switch .Testing and commissioning all as directed. Note :(i) Maintenance to be carried out by the reps of authorised firm.( ii) After Competion test certificate shall be furnished from firm.
M & L for fault detection in damaged UG cable by Govt approved agency and using digital cable fault detector machine with DC high voltage current injectng to damaged cable and find fault near or accurate of 2 mtr in various location at Chabua (AF) Stn of any size and type of 11 KV rated UG cable including the following in quoted rate all as directed and specified by Engineer-in-Charge:- (i) excavation & earthwork in any type of stratra of size 4 x 2 x .60m to usually inspect / repair the damaged cable when and where required. (ii) Sand cushioning in trenches, supply and laying conncrete cable cover, class HV, type I, flat, size 300 mm x 180 mm x 40 mm laid flat in trenches over the cable. (iii) Repair the damaged cable through straight joint as per existing size and made functional. Note :- (i) The fault should be done within 24 Hrs of time frame after informed by Tephonically Msg or letter. Falling which 1000/- per hrs will be levied from the contractor as penalty. (ii) Joint kit shall be paid separately on realivant items of the schedule.
Taking out of 11 KV 3 core 95 sqmm HT cable from duct/trench by taking proper electric shut down from AGE E/M (AF) Chabua and making good to the disturbed surface complete all as specified and as directed.
Taking out of 11 KV 3 core 240 sqmm HT cable from duct/trench by taking proper electric shut down from AGE E/M (AF) Chabua and making good to the disturbed surface complete all as specified and as directed.
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified.
Supply, laying in trenches/through pipes under road, floor/ on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade, of size 3 core 240 sq mm complete all as specified.
Relaying of existing serviceable XLPE insulated,armoured,heavy duty,PVC sheathed electric cable with aluminium conductor,11000 volts grade connecting cross sectional area 95 sqmm 3 core all as directed at site
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Re-laying of existing serviceable HT Cable cover of size 300x180x50 mm complete all as specified and directed at site.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx 180mm x 40mm laid in trenches as cable covers complete all as directed.
M/s HALDER ENTERPRISE (BID ID -3171330)
ms singh construction (BID ID -3173150)
STANDARD ELECTRIC WINDERS (BID ID -3172386)
M/S A K BROTHERS (BID ID -3173464)
M/S SINGH TRADERS (BID ID -3171527)
R D Enterprises (BID ID -3172806)
M/S MANASEE (BID ID -3170985)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .