| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹11.5 L+₹1.1 L (10.1%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹13.8 L+₹3.4 L (32.9%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹15.5 L+₹5.1 L (49.2%)Rejected-Finance | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹18.5 L+₹8.1 L (77.8%)Rejected-Finance | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹55,980
Closing Date
22 Jun 2024, 6:00 pmClosed
GE (U) Meerut cantt
Roorkee road Meerut Cantt
REPAIR/ REPLACEMENT OF ELECTRIC FITTINGS AND FIXTURES, DBS, WIRING, SUB MAIN, EARTHING ETC. REPAIRS/OVERHAULING OF CEILING FANS, EXHAUST FANS, WALL FANS, AIR CIRCULATORS AND GEYSER AND ALLIED WORKS IN OTM A ACCN, BLOCK C SHO, MDC AT MH UNDER AGE E/M
2024_MES_655891_1
8608/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (U) Meerut cantt
₹55,980
Yes
21 Sept 2024
25 May 2024
29 Jun 2024
25 May 2024
22 Jun 2024
8 Jun 2024
Amount
Taking down carefully copper/aluminium point wiring of any type, batten or conduit, (Light, Fan, Socket or power) complete incl fittings and making good the disturbed surfaces of walls, ceiling etc in cement mortar (1:4) and applying two coats of white/colour washing/distempering etc to match the existing surface complete all as directed by Engineer - in- Charge.
Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS PVC insulated, unsheathed copper conductor cable in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated FRLS copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings:- (Rate for cutting chases of walls andmaking good surface as existing all are included in the quoted rate)
One light point or one fan point or bell point controlled by one switch or bell push
One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
All as per serial item No 2 here in before but with 2.5 Sqmm nominal cross sectional area copper conductor FRLS cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed
Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS PVC insulated, unshethed copper conductor cable in Existing PVC concealed Conduit Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC FRLS insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings.
One light point or one fan point or bell point controlled by one switch or bell push
One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one, one way 05/06 Amps switch
One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
All as per serial item No 4 here in before but with 2.5 Sqmm nominal cross sectional area FRLS copper conductor cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, FRLS PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed
Material & labour for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FPVC insulated, unsheathed copper conductor cable in open conduit/casing caping of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings.
One light point or one fan point or bell point controlled by one switch or bell push
One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
All as per serial item No 6 here in before but with 2.5 Sqmm nominal cross sectional area FRLS copper conductor cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed
Material & labour point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, PVC insulated, unsheathed copper conductor cable FRLS in and including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc,alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC conduit terminated in modular switch board including modular metal flush box with white suitable cover plate with frame as per site requirment. two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing for the following. [Note: - cutting chases of walls and making good surface to as exiting are included in the quoted rate)
One light point or one fan point or bell point controlled by one switch or bell push
One 3 pin, 05 /06 Amps socket outlet point on independent board controlled by one , one way 05/06 Amps switch
One 3 Pin, 05 /06 Amps socket outlet point on same board controlled by one, one way 5/06 Amps switch
All as per serial item No 8 here in before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 /16 Amps socket outlet point on independent board with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed
S & F Modular Switch 1 way 6 A, 1 module
S & F Modular Switch 1 way 16 A, 1 module
S & F Modular Socket 6 A, 2/3 pin combined 2 module
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
S & F Modular Fan step regulator, 120 watt, 2 module
S & F Modular Bell push 6A, 1 module
S & F Modular Blank plate, 1 module
Supply & fixing switch piano flush type, 05/06 Amps single pole, one way 240 volts complete all as specified & directed .
Supply & fixing of bell push, flush type 05/06 Amps, 240 volts complete all as specified & directed .
Supply & fixing bell, AC, 230 volts, single pole, ding dong type size compete all as specified & directed.
Supply & fixing switch piano flush type, 15 /16 Amps single ploe, one way 240 volts complete all as specified & directed .
Supply & fixing socket outlet 3 pin, 05/06 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing of socket outlet 3 pin, 15/16 Amps (2 -in-1 Multipurpose) flush type 240 volts complete all as specified & directed.
Supply & fixing ceiling fan regulator, electronic, type, rotary 0 to 04 steps, hum free, AC, 230 volts, 100 watts duty ISI Marked with and including modular white surround complete all as specified & directed.
Supply & fixing lamp holder (Angular/Straight), insulated body, with back plate for batten fitting complete all as specified & directed
Supply & fixing of ceiling rose surface bakelite 65x 50mm three terminals complete all as specified & directed.
S&F in repair 10 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor PC LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 2' long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F in repair 20 watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative aluminium extruded T5 LED battens, Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, easy to install, Efficacy:100 lumen/watt, Minimum 3.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S&F in repair 20 watts Light emitting Diode (LED) smart tube light fitting wall mounting, indoor decorative aluminium extruded T5 LED battens, Inbuilt occupancy sensor with minimum 6mtr dia sensor coverage area, 30% light output in case of non-occupancy, constant current output driver, AC 230-240V, 50 hz, with Opal diffuser, 4' long, easy to install, Efficiency:100 lumen/watt, Minimum built in 2.5 KV Voltage Serge Protection, Power factor > 0.9, making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
S & F in repair Recess mounted economical LED panel light 2`X2` 36 watt with high effciency, efficacy 110 lumen/watt LED luminaires LED luminaire made in CRCA sheet metal with wider light window and opal polystyrene diffuser for spotless glare-free uniform lighting complete all as specified and directed.
S&F in repair LED 10 watts wall bracket light aesthetically designed wall bracket light with B22d Lamp holder and bulb as per sample directed by Engr-In-Charge complete all as specified and directed.
Supply and fix in repair LED post top for gate light 45 Watt with spun aluminium housing and pressure die-cast spigot. Clear polycarbonate diffuser for uniform bright light,CCT 5700K, efficacy 95lm/watt, with IP65 degree of protection & impact resistance complete all as specified and directed.
Supply & Fix in replacement LED Emergency LED linear Lamp, Wattage 10W, Voltage /frequency 220-240V/ 50-60Hz, Cool Day light, PF > 0.9 CCT 6500K, upto 4 Hrs Back up all as specified and directed by Engineer-in-Charge.
Supplying, fixing in replacement LED Security light IP65, including connecting and made out of pressure die cast anodised aluminium with toughened glass cover housing, 45 watts LED to achieve electrical safety class 1, Pf >0.95, lumens >110 lm/W, Ingress protection not less than IP66 including 32mm nominal bore light grade GI pipe brackets made out of 1.50M long GI pipe ,bent to shape and fixed to poles/ walls with two Nos mild steel flat iron brackets of 40mmx6mm, comprisng 4 Nos mild steel hexogonal head bolts of 12 mm dia, 75 mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, and making connections with cable complete all as specified and directed.
Supply and fix in repair 09 Watt LED bollard light with opal acrylic diffuser, fiting for pathways and garden rectangular shaped victorian design, clear/ milky diffuser spun cover, die cast pole mounting, efficacy 95 lm/watt, IP 65, module including fixing in concrete post suitable size GI pipe complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed by the Engineer-in-Charge. (for foundation of post top and bollard).
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in Soft/Loose soil including trimming sides and bottom of trenches complete all as specified and directed.
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed.
M & L for sub main wiring with 4 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi stranded, Fire Retardant conforming to IS 694-1990, PVC insulated, unsheathed, copper conductor stranded cable FRLS with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing, including taking down old U/S sub main wiring any size complete all as specified and as directed.
M & L for sub main wiring with 6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi stranded, Fire Retardant conforming to IS 694-1990, PVC insulated, unsheathed, copper conductor stranded cable FRLS with and including continuous earth wire of size 6.0 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing, including taking down old U/S sub main wiring any size complete all as specified and as directed
M & L for sub main wiring with 10 Sqmm nominal cross sectional area, 4 single core, 1100 Volts grade, multi stranded, Fire Retardant conforming to IS 694-1990, PVC insulated, unsheathed, copper conductor stranded cable FRLS with and including continuous earth wire of size 10.0 Sqmm nominal cross sectional area, single core , PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc and connected to common earth dolly including all cutting/ chases etc in wall, making good to walls etc including two coats of white/ colour washing/distempering etc to the disturbed surfaces to match the existing, including taking down old U/S sub main wiring any size complete all as specified and as directed.
Supplying and fixing 10 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor,drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etc served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, twin core cable flat or circular, including taking down old U/S cable any size complete all as specified and as directed all as specified and directed.
Supplying and fixing 6 Sqmm 1100 volts grade heavy duty cable PVC insulated aluminium conductor, drawing into and including rigid non metallic PVC conduit of 25 mm dia, medium grade with all conduit accessories/ fittings ,brass screws, washers etcserved with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire,cable core cable flat or circular, including taking down old U/S wiring any size complete all as specified and as directed
Supply & fixing MCB, SP, AC, 240 volts of 05 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs, including taking down old U/S MCB SP complete all as specified & directed.
Supply & fixing MCB, SPN, AC, 240 volts of 40 to 63 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs, including taking down old U/S MCB SPN complete all as specified & directed.
Supply & fixing MCB, TPN, 415 volts of 100 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs, including taking down old U/S MCB TPN complete all as specified & directed
Supply & fixing MCB DB Box 8 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing including taking down old U/S MCB DB box complete all as specified & directed.
Supply & fixing MCB DB Box 4 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing including taking down old U/S MCB DB box complete all as specified & directed.
Supply & fixing MCB DB Box 12 way 200 Amps capacity, 240 volts, Double door, SPN and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing including taking down old U/S MCB DB box complete all as specified & directed .
Supply & fixing Sheet Metal Enclosures TPN, 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing including taking down old U/S MCB DB box complete all as specified & directed.
Supply & fixing Sheet Metal Enclosures vertical TPN distribution board with provision for & including 100 Amp MCCB TPN as incomer with necessary internal wiring, MCBs as outgoing , 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing including taking down old U/S MCB DB box complete all as specified & directed.
S&F MCCB 4Pole 415 V fixed type, 63/100 Amps with breaking capacity 16 KA including taking down old U/S MCCB complete all as specified and directed
Supply & fixing Sheet Metal Enclosures with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps capacity 240 volts 'B' series 10KA and making connections complete all as specified & directed including taking out old AC box u/s any capacity.
Supply and fix in repair metal clad socket 20 Amp 2P+E, 230 volt AC complete all as specified and directed
Supply and fix in repair metal clad plug 20 Amp 2P+E, 230 volt AC complete all as specified and directed
S&F in repair Hylum sheet 3 mm thick of 9"x5" size for fix suitable PT switches/sockets/regulator complete all as specified and directed.
S&F in repair Hylum sheet 3 mm thick 9"x7" size for fix suitable PT switches/sockets/regulator complete all as specified and directed.
S & F in replacement LED Bulb 12 watt 240 volt complete all as specified and directed.
Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by GI earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion (GI earth strip will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I.
Taking down of existing unserviceable wall fans and S&F wall mounting fan 400 mm sweep in replacement including making connections with suitable size of copper wire and making good surfaces complete all as specified.
Taking down of existing unserviceable ceiling fan and Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Complele all as specified and directed
Taking down existing unserviceable ceiling fan of 1200/1400 mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan with 2.5MFD capcacitor including replacement of ball bearing and connection wire upto ceiling rose 1.5 metre , cleaning, painting and testing the fan for its RPM and others and refixing the fan in its position and making connections and replacement of mild steel clamps and S hook complete all as specified and directed.
Taking down existing serviceable ceiling fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, checknuts, pin etc. and re-assembling and refixing in position , connecting and testing complete all as specified.
Taking down existing unserviceable exhaust fan of 450mm/380/300 mm sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan , cutting the winding and removing the coils and rewinding the fan with suitable size of super enameled copper winding wire, insulation, varnishing, greasing and assemling the fan with 4.0 MFD capcacitor including replacement of ball bearing gun metal bush and connection upto 1.5 metre , cleaning, painting and testing the fan for its RPM and others and refixing the fan in its position and making connections with existing wire with terminals of ceiling rose complete all as specified and directed.
Taking down existing serviceable Exhaust fan of any sweep from fan box/ hooks by disconnecting electrical connections from ceiling rose, de-assembling the fan, removing and cleaning of dust properly , oiling and greasing bearings/ bushes including renewal of washers, split pin, screws, check nuts, pin etc. and re-assembling and refixing in position, connecting and testing complete all as specified and directed.
Taking down of existing unserviceable exhaust fan plastic body 250mm and S&F exhaust fan plastic body 250mm sweep including making connections with suitable size of copper wire and making good surfaces complete all as specified and directed.
S & F in replacement cylinder capacitor 2.5 MFD with earthing terminal for ceiling fan / cabin fan motor including soldered leads for connections ISI-1709, MPP ( metallised polypropylene, (self healing),complete all as specified and directed.
S & F in replacement Renewal of cylinder capacitor 4 MFD with earthing terminal for Exhaust fan motor including soldered leads for connections ISI-1709, MPP ( metallised polypropylene,(self healing), complete all as specified and directed.
Supply & Fix in repair ceiling fan down rod of MS pipe 15mm bore of length as per site measurement including cutting/threading making tide for fixing providing check nuts wachers etc complete all as specified and directed.
S & F in repair PVC insulated 23/0.0076 flexible cord twin core with stranded copper conductor complete all as specified and directed.
S & F in replacement Poly carbonate Body plug top 3 pin, 6 Amps, 230 Volts complete all as specified and directed.
S & F in replacement Poly carbonate Body plug top 3 pin, 15/16 Amps, 230 Volts complete all as specified and directed.
KUKREJA BROTHERS
VIRAT CONSTRUCTIONS
NITHYA INFRATECH
Sumati Electronics Pvt. Ltd.
Ramesh Traders Govt Contractors & General OrderSuppliers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .