| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | ₹1.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.5 Cr+₹12.6 L (8.82%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹1.5 Cr+₹12.6 L (8.82%) | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹1.6 Cr+₹17.6 L (12.4%)Rejected-Finance 1 206 SHOP NO 71 MANDIR MARKET SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹1.6 Cr+₹17.6 L (12.4%) | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹1.6 Cr+₹18.6 L (13.1%)Rejected-Finance | ₹1.6 Cr+₹18.6 L (13.1%) | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹1.9 Cr+₹45.2 L (31.8%)Rejected-Finance | ₹1.9 Cr+₹45.2 L (31.8%) | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
19 Oct 2024, 6:00 pmClosed
HQ Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
ADDN ALTN AND RENOVATION BLDG GS BRANCH AT HQ DELHI AREA UNDER GE EAST DELHI CANTT10
2024_MES_671607_1
CEDZ/TOKEN-30 OF 2024
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt
As per NIT
8 documents required · 8 mandatory
₹1,000
GE East
₹2.6 L
Yes
20 Dec 2024
4 Sept 2024
21 Oct 2024
4 Sept 2024
19 Oct 2024
5 Oct 2024
11 Sept 2024 - 13 Sept 2024
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) any type and size not exc. 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) any type and size exc. 1.5 Sqm but n. exc. 4.00 Sqm each complete all as specified and directed.
Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws,etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Supply and fixing factory made uPVC white colour Casement door with top hung ventilator with 3D and SS friction (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 + 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 3.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels alongwith zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc.Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in-Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.5 m height made of (big series) frame 112 x 52 mm & sash 42 x 66 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.20 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh hall be paid separately). (Note: The unit rate quoted by contractor include all other connected accessories. Net Opening will be measured lor payment purpose and for uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.)
Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 1.50 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass/ wire mess shall be paid separately). (Note: The unit rate quoted by contractor include all other connected accessories. Net Opening will be measured lor payment purpose and for uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.)
Providing and fixing factory made uPVC white colour frame 60 mm x 58 mm for fixed toughned glass (any thickness) window / opennings etc , made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2+ 0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, including glazing bead 35 mm x 20 mm all as complete and as directed,( Note :- Glass shall be paid separately).
S & F 5.5 mm thick sheet glass , ordinary quality and glazedy in square size in each pane fixed complete all as specified and directed.
S & F 8 mm thick Toughned glass fixed as in UPVC / Aluminium doors, partitions, windows, opennings etc and similar work including cutting to shape, drilling holes required icluding frosted on one side etc complete all as specified and directed
S & F 12 mm thick Toughned glass as in hinged doors / as in floor door closer door type, partitions, automatic doors. Sliding door, fixed portion and similar work including cutting to shape, drilling holes and including accessories and ss handels , locking sysytem with keys required etc complete all as specified and directed
S&F stainless steel wire cloth power coating 0.36mm normal dia of wire and average with a apparture 1.40mm and fixed with tinned tacksor stainless steel wire staples as specified and directed.
S & F of aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed properly with frame etc complete all as specifed and directed.
S & F for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed etc complete all as specifed and directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing, guard bars, grills etc made of hollow tubes, channels, plates , bars , flats etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing, guard bars, grills with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement all as specified and directed. Note: (i) Modular SS railing Design, size and pattern of railing in balcony, staircase, grills in windows etc as per relevant IS code and as approved by GE. (ii) Rate quoted shall be deemed to be inclusive for fixing in existing/new wall, RCC slabs, parapet wall etc. (iii) Tests for stability, load bearing capacity etc. of railing at balcony, staircase, grills in windows etc. shall be carried out as per relevant IS code and as directed by GE before payment of the item.
S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Plain Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with density not less than 650 kg/cbm Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free. Water/ Moisture Proof, Fire Retardant All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : . (Design and pattern as approved by GE).For Toilet cabinate for WHB , office cupboard & Cabinets and pull out test shall be carried out as directed by GE.
S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free. Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : (Design and pattern as approved by GE).For Toilet cabinate for WHB , office cupboard & Cabinets and pull out test shall be carried out as directed by GE.
S & F for Hettich soft closure hinges with all fittings at mounting plate of premium quality, fixed in door/cup board shutters complete all as specified and as directed (Make : - Godrej/Hettich and make as per approved make list and as approved by GE).
S & F 100 mm size cup board locks of brass including keys set, complete all as specified and as directed.
S & F for stainless steel 150 mm long cupoard handles fixed with nut, screw and washer of stainless steel, complete all as specified and as directed.
S & F colour Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete and the directions of Engineer-in-Charge. ( Glass/ ACP paneel/ partical board paid separately)
S & F 12 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice laminations , fixed with aluminium partations, door, cupboard etc complete all as specified and as directed. all as specified and directed.
Dismantling celing/wall existing old board (fibre pulp.insulation etc) or insulation boards/slabs/blanks any thickness including cover fillets etc
Providing & fixing false ceiling at all heights with Semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595×595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15×32 mm of length 3000 mm, cross – T of size 15×32 mm of length 1200 mm and secondary intermediate cross-T of size 15×32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall wood screws complete all as specified and as directed. Note- The Gird should be Black and White Silhouette system
M & L for 10 to 12 mm thick plaster of paris ceiling (POP ceiling) (Gypsum anhydrous) including necessary GI frame work and reinforced with G.I. wire mesh including Hangers 6 mm dia. G.I. adjusting level fixed to roof slabs including any design pattern & Cob as approved by GE etc completed all as specified and directed.
M&L for dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off from premises complete all as specified and directed
M&L for demolition to Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed
Demolition of cement concrete any description and any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor or in any position and paving not exc. 15 cm thick (below or above ground level) complete all as specified and as directed.
M & L 25 mm Thick PCC type B-0 1:2:4 (12.5mm graded aggregate) as in flooring, under Tiles and etc all as specified and directed
M&L for vitrified tiles double charged (square/rectangular) polished, (dark and light shade combination design pattern and boarder as approved by GE) , area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm of size (600mm X 1200mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over and including 15mm thick screed bed or bedding layer of cement mortar in (1:4) etc. complete all as specified and as directed.
M&L for vitrified tiles double charged (Square/ rectangular) polished, (colour, design & pattern as approved by GE) area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm of size as in skirting, dado, vertical surface laid over and including 10 mm thick cement plaster in CM (1:3), set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tiles etc. Complete all as specified and as directed.
M & L matte finish Vitrified tiles full body / double charged 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles laid over 15 mm thick avg screed bed in CM 1:4 complete all as specified and directed.
M&L for 18 -20 mm thick granite stone slab in (Z- black and equivalent as approved by GE ) table rubbed and polished , in steps ( double granite patty in edge in tread with 3 No’s grooves line) in riser , jambs, pillar, window cills, cooking platforms, dado, skirting etc. where ever required in single piece., including full moulding of edges to match the colour of granite and fixed with 15mm thick cement mortar in 1:4 including pointing in white cement using marble dust with admixture of pigment to match complete all as specified and directed Note: - (a) "Minimum rate of granite should not be less than Rs.150 Per Sqft excluding GST”
M & L for Granite (Z- black and equivalent as approved by GE ) stone/ tiles 18mm to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20 mm thick screed bed in CM 1:6 complete all as specified and directed Note: - (a) "Minimum rate of granite should not be less than Rs.150 Per Sqft excluding GST”
M & L for Granite (Z- black and equivalent as approved by GE ) stone/ tiles 18mm to 20mm thick tiles machine cut, in skirting/ dado laid over 10 mm thick cement rendering in CM 1:3 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completecomplete all as specified and directed Note: - (a) "Minimum rate of granite should not be less than Rs.150 Per Sqft excluding GST”
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement or cement lime morta including all quoins, arches,pillars, etc,
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete all as specified and directed. Note : brick work including also for closing the openning of windows / doors, new provisions and old demolition area repair etc
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4, in half brick thick complete all as specified and directed by Engr-in-Charge. Note : brick work including also for closing the openning of windows / doors, new provisions and old demolition area repair etc
Taking down cement or cement lime plaster of any description on brick or stone walls and concrete surface of ceiling etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 12 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and fair complete all as specified and directed by Engr-in-Charge.
M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces , applied in two layers i.e.. Ist layer of 10 mm thick rendering in cement mortar (1:6 ) and 2nd ( top ) layer of 5 mm thick rendering in cement mortar (1:4 ) mixed with WPC finished even and fair etc complete all as specified and directed.(Note:- WPC shall be measured and paid separately.)
M&L for Liquid water proofing compound complete all as specified and directed
M & L Rendering 5 mm thick on fair faces of concrete or concrete surface in ceiling in CM 1:3, finished even and fair complete all as specified and directed by Engr -in Charge.
M & L Rendering 10 mm thick on fair faces of concrete or concrete surface in ceiling in CM 1:3, finished even and fair complete all as specified and directed by Engr -in Charge.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for etc complete.
M & L for RCC M-25 design mix as in slabs supported on walls, beams and columns in floors , roofs, landings , balconies, canopies, deck slabs and shelves etc complete all as specified and directed by Engr-in-Charge.
M & L for RCC M-25 design mix as in Beams , cantilevers, bressummers, lintels over 1.5 m span , lintel beam over opennings, new provision of beams for opennings & supports etc etc complete all as specified and directed by Engr-in-Charge.
M&L for Providing & Pouring Micro concreting M-40 grade including following :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying epoxy bond coat on the sound concrete substrate using approved spray machine or suitable brushes & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of above bond coat as above pour prepacked dual shrinkage compensated. Micro concreting M40 grade, using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams, columns, slab, parapet, staircase, RCC water tank etc., up to 100 mm thickness of micro concrete. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note: - This item shall be executed in bldgs. (G+1) and necessary provision for T&P, scaffolding and safety measures etc. shall deemed to be included in unit rate quoted by the tenderer for the same.
M & L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips etc complete all as specified and directed by Engr-in-Charge. (Note :- TMT steel beinding with existing old steel , sections with welding required as per site as directed by GE)
M&L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia in strirrups, spaces and binder and including mild steel wire (annealed) not less than 0.9mm dia etc complete all as specified and directed by Engr-in-Charge.(Note :- TMT steel beinding with existing old steel , sections with welding required as per site as directed by GE)
M & L for Formwork to chullah hoods, chajjas, troughs and similar items including edges etc for flat rough finished surfaces complete all as specified and directed by Engr -in Charge.
M & L for form work to sides and soffits of floor or roof beam, beam hauchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc for flat rough finished surfaces complete all as specified and directed by Engr -in Charge.
M & L for form work to edges of concrete flats, treads breaks in floors , window cills , concrete railling, opening in concrete walls, floors and roofs RCC/PCC bands floors roofs n exc 20 cm wide and sides of RCC/PCC bands in walls , horizontal or slooping and similar work exc 5.00 cm and not exc 10.00 cm wide surface finished rough complete all as specified and directed.
M & L Preparing of New plastered surfaces and applying two coats of oil bound distemper including 2 mm thick wall care putty on ceiling surface etc complete all as specified.
M & L Preparing of Old plastered surfaces and applying two coats of oil bound distemper including 2 mm thick wall care putty on ceiling surface etc complete all as specified.
M & L for complete removal of existing internal/external any type of treatment including preparation of old decorated brick/ concrete /plastered/un-plastered surfaces/pointing/un-pointing surface of walls, pillers, cornices etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil and greasy spots including cracks/holes in surface filling with white putty etc to receive further, any type of treatment, complete all as specified and directed.
M & L for preparation of internal new surface of plaster/concrete surface of walls, pillers, cornices etc to receive further, any type of treatmentc, complete all as specified and directed.
M & L for Providing and applying plaster of paris putty of 2 mm thickness over old/new plastered surface to prepare the surface even and smooth with sand paper etc complete all as specified and directed.
M & L for applying a layer of 1 to 2 mm thick wall care putty on prepared internal surfaces of wall, pillars, cornices etc. to prepare the surface even & smooth using sand paper etc. to receive further , any type of treatment , complete all as specified and directed.
M & L for applying a coat of primer and applying two coats of OBD 1st quality (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification on new work/putty surface / POP surface etc. complete all as specified and directed.
Dismantling existing water tanks of capacity exc.500 ltr & n. exc 1000 ltr any type and any position and removing to store complete all as specified.
S & F rotational moulded polythene, water storage tank Triple Layered 1000 Ltrs capacity, White color ,closed top, cylindrical, hoisted and fixed in position including cpvc tank nipple for fixed to cpvc pipe complete all as specified and dirtected by Engr-in-Charge .
S & F in repair 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed minimum weight -210gms, complete all as specified and as directed.
Taking up or down 20 mm mm bore steel tubing and connections, position etc including cleaning for refixing or removal to store complete all as specified.
Taking up or down 15 mm mm bore steel tubing and connections from any position etc including cleaning for refixing or removal to store complete all as specified.
S&F 20 mm Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings onwalls/ceiling or laying infloors complete all as specifiedand cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthetc complete all as specified and directed.
S&F 25 mm Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings onwalls/ceiling or laying in floors and roofs including two storey bldg roof to bottom postion etc complete all as specified and as directed.
S&F 25 mm dia CPVC gate valves, with handel any type , fitted to the CPVC pipes, complete all as specified and as directed.
S&F in repair fancy type chromium plated quarter turn brass angle valve type suitable for 15mm bore pipe complete all as specified Make: Jaquar FLR 15053PM, CERA F1001201, Hindware F570043”
S&F in repair 15mm Urinal Valve Auto Closing System with Built-in Control Cock & Wall Flange screwed both ends for iron pipe or for unions for 15mm bore steel tubing complete all as specified & directed. “Make: Jaqaur Cat Part No. PRS-CHR-077, Parryware Model : G2007A1 , Hindware- F310016CP as approved by GE”
S&F in repairs Pillar Cock Auto Closing System, cast copper alloy , fancy type , chromium plated, screwed for iron pipe and fixed complete all as specified and directed. “Make: Jaquar-Cat part No. PRS—CHR 031, Hindware- F310001A, Parryware- G2013A1 as approved by GE,
S & F in repair Vitreous China Urinal, full stall type Urinal With Fixing Accessories, white and fixed complete all as specified and directed. “Make: Jaquar Cat part No. URS –WHT-13261, Hindware Cat Part – 60002 , Parryware-WPC05831C as approved by GE”
S & F in repairs Vitreous china Rimless Bowl With Cistern For Extended Wall Hung WC With PP Soft Close Seat Cover, Hinges, Dual Flush Cistern Fitting, Accessories Set, Size: 375x630x750 mm including connecetion to drain pipe with all fitting and fixture complete all as specified and as directed. Make: Jaquar-Cat part No. Continental Series CNS-WHT-363SPPZ, Hindware Cat part No. 20084 (Mario Extended), Kohler Cat part No. K-17661K-S-0 as approved by GE
S & F in reapir Vitreous chinaware table top wash hand basin (WHB) of complete including 32 mm dia chromium plated waste coupling, etc., complete all as specified and as directed. (Make: Jaquar Cat part No. -KUS-WHT-35935 , Hindware Magna Cat part No 10079 , Kohler Cat part K-2660IN-1-0 as approved by GE).)
S & F in repair PVC connections 15mm size with PTMT nuts of length 600 mm.
S&F in repairs Hand Shower (Health Faucet) with 8 mm Dia, 1 Meter Long Flexible Tube & Wall Hook completed all as specified Make: Jaquar Cat part No. ALD-CHR-573, Hindware Cat part No F160193CP , Kohler Cat part - 98100IN-CP as approved by GE).)
S & F in repair Towel Ring Round with Round Flange fixed in positon with and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and as directed. Make : Jaquar Cat part No. ACN-CHR-1121BN and equivalent in jaquar / Hindware/Parryware or equivalent make as per approved make list).)
S&F in repairs of 32 mm brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, unions and cap and fixed, complete all as specified and directed.
S & F in repair Toilet paper Roll Holder with Stainless Steel Flap, and including chromium plated brass screws and wooden/plastic cleats, complete all as specified and as directed. Make: Cera Cat No: F5004110, Jaquar Cat No CPA-CHR-1153, Hindware Cat Part No. F-880003CP, Kohler Cat No K-5633IN-CP as approved by GE.)
S & F Designer type high quality fancy type looking mirror of size as approved by Engr-in-Charge 8-10mm thick, fixed to wall with stainless steel studs, screws, brackets and washers etc complete all as specified and as directed.
S & F in repair 100 /110 mm dia PVC floor trap , with SS grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
S&F in repair 75 mm dia Hubless cast iron pipe ( as per IS-15905 : 2011 ) soil, waste and vent pipes in any length including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” and laying in trenches or in floors or in wall with clip etc. complete all as specified and directed.
S&F in repair 100 mm dia Hubless cast iron pipe ( as per IS-15905 : 2011 ) soil, waste and vent pipes in any length including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” and laying in trenches or in floors or in wall with clips etc. complete all as specified and directed.
S & F in repair 100 mm dia (bore of pipe) Hubless cast iron as per IS-15905: 2011” branch pieces, bends any type, (with access door and cover) etc. including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” complete all as specified and directed.
S & F in repair 100 mm dia (bore of pipe) Hubless cast iron as per IS-15905: 2011” Tee, Sweep Door Tee with Socket (with access door and cover) etc. including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” complete all as specified and directed.
S & F in repair 75 mm dia (bore of pipe) Hubless cast iron as per IS-15905: 2011” Tee, Sweep Door Tee with Socket (with access door and cover) etc. including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” complete all as specified and directed.
S & F in repair 75 mm dia (bore of pipe) Hubless cast iron as per IS-15905: 2011” branch pieces, bends any type, (with access door and cover) etc. including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” complete all as specified and directed.
S & F in repair 75 mm dia (bore of pipe) Hubless cast iron as per IS-15905: 2011” vent cowls etc. including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” complete all as specified and directed.
S & F in repair 100 mm dia (bore of pipe) Hubless cast iron as per IS-15905: 2011” vent cowls etc. including jointed with stainless steel shielded SS-304 coupling double screw system with EPDM Rubber” complete all as specified and directed.
M & L for plain cement concrete 1:2:4 ( type B-2 using 12.50 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed.
M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 20 mm average thickness in single layer and finishing with trowel with a bond coat : SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type and also taking down cement plaster on brick/concrete surfaces, including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified and as directed. Make: Asian Paints or equivalent in Sika, Fosroc and STP Ltd and Dr Fixit., Birla Note : The application shall be executed on any type of surface and on horizontal/Vertical areas.
Providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajjas in multiple coats @ 2.0 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge. Make: Smart Care Damp Proof of Asian Paints or Birla Opus Prime B70 or equivalent in and STP, Dr Fixit. Notes: (1) The work shall be executed through authorised applicator of manufacturer (2) Authrised Applicator shall be approved by GE before starting of work. (3) Warranty of roof treatment provide as per manufacturer
Taking down and refixing of exsiting any type of AC outdoor unit from roof top including store the gass during the taking down out door unit , remove the wire, cable , ac gass pipe etc for roof treatment and refixing again after roof treatment including refilling of AC gass , coper pipe , wire etc as required during refixing the outdoor unit of AC etc all as completed and specified.
M&L for followings :- (i) Removing plaster & finishes from all exposed / damaged portion of facia, roof projection, parapet, chajjas , over hanging slabs, columns, slabs ceiling & beams (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed and cleaning all around. (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved) (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. Note :- This item will be also executed in highrise bldgs and necessary provision for T&P, scaffoling and safety measures etc shall deemed to be included in unit rate quoted by the tenderer for the same.)
M&L for providing rust proof /anti corrosive treatment to bars :- (i) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of polymer modified anti corrosive cementitious coating with a total thickness of 2mm coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. Note :- This Item will be also executed in highrise bldgs and necessary provision for T&P, scaffoling and safety measures etc shall deemed to be included in unit rate quoted by the tenderer for the same.)
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine or suitable brushes & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of atleast strength equivalent of M-40 concrete of average 25 mm thickness. Note:Application of PMM shall be preferably be in coats of appx 10mm thickness.PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. Note :- This Item will be also executed in highrise bldgs and necessary provision for T&P, scaffoling and safety measures etc shall deemed to be included in unit rate quoted by the tenderer for the same.)
Excavation in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum getting out, returning, filling in ramming earth or broken rubble in layers not exceeding 25 cm, watering and removing of surplus soil to a distance not exc 50m and making good surfaces, complete all as specified and as directed.
S & F painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall in any shape and curved), fixed with self tapping screws complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F steel work in tubular trusses ( designer poles, including bends, curved sections as per directed), posts etc including special shaped washer etc. complete using ERW or induction butt welded tubes confrming to IS 1161-1979 grade St-240 complete all as specified and directed
M&L for PCC (1:3:6) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concreteetc, complete all as specified & directed
S & F framed work such as in door frame, door shuters / gate of angel or other section with gusset plates, rails, braces, etc complete , drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hings or steel hanging door fittings, including hings hold fast of Fe 410-W (Gde E-250 quality) etc complete all as specified.
S&F rolled mild steel work as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250), Quality B, complete all as specified and directed
M&L two coat of synthetic enamel paint (finishing coat) over one coat of primer to new steel surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified.
Dismantling plain/ corrugated roof sheeting, any gauge, thickness, including , Nainital or similar pattern roof coverings sheet in any pattern & position of roof coverings.
S & F for 3 mm thick Polycarbonate Transparent colour Roofing Sheet in any shape and curved including 150 mm sides and joints overlap fixed with self-tapping full thread screws with bitumen washer etc. complete all as specified and directed.
M & L for 5 mm thick Rubber tiles with fabric backing or insert, plain coloured or marbled topping, matt or glossy, laid in floors with approved adhesive all as specified and directed
M & L for glazed ceramic tiles of approved colour and design in vertical surfaces 300 x 600 x 7to 8 mm thick including provision of high lighter tiles/ boarder and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar 1:3 etc all as specified and directed
S&F for Framed work such as grills, gratings, etc with encs of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe. 290. Gde- E-168
M&L for PROwood grooved panel having system NRC up to 0.88 with lineal perforation. The high grade MDF panels shall be melamine laminate of appx size 2440mm x1220mm x 15 to18mm with 2mm groove at 14mm pitch, Tongue and Groove edges for seamless mounting having density of 800kg/m3(base panel confirming to IS 12406 and laminated panel confirming to IS 14587). The back of the panels are perforated with a nonwoven fabric covering of 0.2mm for providing Sound absorption via the acoustic impedance method. Panel is fixed by using GI Framework 2400mmx50mmx0.50mm spaced at 600mmx600 c/c & 16 mm WPC framework spaced at 400mm centers with suitable brackets and the system is backline with 50 mm Rockwool insulation@48kg density and along with all accessories or Screw the aluminum extruded profile for channeled woodworks provided by manufacture over the lowest and second wooden batten at an on- center distance of 600mm. Install the first set of wooden panels by inserting the clips for border channeled woodworks and insert the groove of the panel into the projecting flange of the aluminum clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channeled woodworks into the next keel till the actual height is achieved. Use clips for border channeled woodworks to finish off the installation complete all as specified and as directed.
M&L for WPC interior decorative wall panels/louvers 20 to 26 mm thick prelaminated wood grain teak finished (colour, shade, grooves width and design pattern as approved by GE) including accessories for fixing on wall and molding end caps with L / U beading etc. fixed with PVC sleeves and screws as required at site complete all as specified and as directed.
M&L Providing and applying Ruff 'N' Tuff - Scratch trowel applied synthetic grooved finish texture and equivalent as approved by GE . standard (2 mm to 2.5 mm) medium rough surfaces, coverage @ 4.00 Kg / Sqm as approved pattern and any position /type of wall , piller, columan , facia etc over one coat of weathercoat exterior primer, including applying 02 coats of weathercoat exterior emulsion with recommended dilution ratio as finishing coat and including prepration of new plastered surface and any type of old existing surface etc complete all as specified and as directed by Engr- in-charge. Note :- (i) The work mentioned in above items shall be carried out including upto 10 m height of building which may require scaffolding or Jhulla arrangements or any other T&P items are included in the quoted rates by the contractor.
S & F HPL Sheet exterior glossy ( colour & design as approved by GE) of 6 mm thick joint with cilicon/ adhesive as per manufacturer instruction including necessary aluminium framed work as required shape and size by welding etc fixing to wall / ceiling/ RCC column/boarding/Gates with necessary fixing arrangements upto a height of 10 Mtrs etc complete all as specified and as directed.
S & F automatic Hand dryer white colour made of ABS material, Model dual flow plus complete all as specified and directed. Make & Cat Part : HDR-SLV-AK2030or equivalent in Marc and Kohler.
S & F automatic soap dispenser of capacity 0.80 Ltr made of aluminum/ABS material, complete all as specified and directed. Make & Cat Part : Jaquar-Cat No. SDR-BLC-DJ0160AS or equivalent in Marc and Kohler.
S & F paper towel dispenser of capacity 600 towels made of 304SS grade , complete all as specified and directed. Make & Cat Part : Jaquar-Cat No. PTD-SAP-DT0106CS or equivalent in Marc and Kohler.
Dismantling wall existing old any type paneling / panels etc (fibre pulp.insulation etc) or insulation boards/slabs/blanks any thickness including cover fillets etc
ROAD, PATH AND CULVERT
Surface excavation n.exc 30cm deep and getting 15cm deep avg. and getting out in soft/loose soil
Removing excavated material n. exc 50 m depositing where directed at a level not exceed 1.5 m of the starting point all as specified and directed.
M & L for 100 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing completed all as specified and directed.
M & L for 80 mm thick coloured factory made machine pressed precast cement concrete interlocking paver block any shape and size confirming to IS 15658-2006 M-40 grade ( colour, design and pattern as approved by GE) including 50mm thick compacted bed of dry sand, complete all as specified and directed.
M&L for hard core of gauge n.exc 63mm deposited, spread and leveled in layers n.exc 15cm thick watered and rammed to a true surface with broken bricks complete all as specified and directed by Engr -in Charge..
M & L for 75 mm thick Cement concrete type D 2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing completed all as specified and directed.
M & L for OUT DOOR coloured heavy duty/ full body parking tile/ chequered tiles (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.18 sqm in floors , plinth protection , path etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified
M & L for plain cement concrete 1:2:4 ( type B-2 using 12.50 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor or in any position and paving not exc. 15 cm thick (below or above ground level) complete all as specified and as directed.
SEWAGE DISPOSAL
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations etc or for shafts, wells cesspits, manholes, pier holes, drain etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed by Engr-in- Charge.
Returning & filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removal of excavated material n.exc 50 mtr and depositing where directed at level not exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation etc, complete all as specified & directed
Demolition and breaking up 150 mm dia drain pipes (SGSW/ AC/RCC) including hunching and benching set in cement mortar and removal of debris out side from MoD land complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement or cement lime morta including all quoins, arches,pillars, etc,
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick plastering/rendering on brick work on concrete surfaces in cement mortar (1:3) mixed with liquid water proofing compound as per manufaturer's instructions finishing surfaces even and smooth without using extra cement complete all as specified and directed. (liquid water proofing compound shall be measured and paid sepretaely).
Supply only liquid water proofing compound complete all as specified & directed.
PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in brenching for manholes, bands, coping, bed plate etc with slightly chamfered or rounded angles including necessary from work, if any, and finishing exposed surface even and smooth without using extra cement complete all as specified & directed.
S&F DWCPE (SN8) nominal size 150 mm (internal dia) mm including all fixing accessories or fittings like socket/spigot joint with elastomeric sealing ring, rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and as directed.
M&L for concrete bed to drain pipe including packing under and haunching against the side of pipes, 150mm bore, in cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
M&L for pre-cast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manholes cover, drain cover and set in cement mortar (1:4) including form work complete all as specified & directed.
M & L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips etc complete all as specified and directed by Engr-in-Charge.
S & F Framed work such as in grills, gratings , mainhole cover ,water tank etc and similar work conforming to Fe-290 Gde -E-165 complete all as specified.
Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 300 mm bore drain pipe complete all as specified and as directed.
Construction of soakage well 2.40m internal dia and 3.00m effective depth including excavation in any type of soil,returning filling & removal , PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in footing brick honey comb/ solid brick masonry in cement 1:4, RCC (M-25 design mix) including TMT steel reinforcement in slab including mainhole cover , filled with brick bats including intercepting chamber screen chamber and disposal of soil, complete all as specified and shown on Drg. Note : 1. During excavation if unexpected water is encountered, the same shall be bailed out / de-watered by the contractor mechanically or manually without any extra cost. 2. The excavated surplus soil shall be removed to a distance exceeding 50 mtr and not exceeding 100 mtr and deposited where directed by the Engineer-in-Charge.
AREA DRAINAGE
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations etc or for shafts, wells cesspits, manholes, pier holes, drain etc n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed by Engr-in- Charge.
Returning & filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removal of excavated material n.exc 50 mtr and depositing where directed at level not exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete any description and any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement or cement lime morta including all quoins, arches,pillars, etc,
M & L for Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge.
M & L for 15mm thick rendering in cement mortar 1:4 on fair face of brick walls/ concrete surfaces in any position etc, complete all as specified and directed by Engr-in-Charge.
M & L for PCC 1:3:6 type D2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed.
M & L for PCC 1:2:4 type B-2 using 20mm graded stone aggregate as in surface channels and drains all as specified and directed.
M & L for extra for forming fair finished drain or channel 45 cm inner grith in cement concrete , using extra cement, including forms, moulds, mi-tred/ stopped ends etc.
PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in brenching for manholes, bands, coping, bed plate etc with slightly chamfered or rounded angles including necessary from work, if any, and finishing exposed surface even and smooth without using extra cement complete all as specified & directed.
S & F precast polymer trench drain with minimum 50 mm thick perforated drain cover (M-30 grade made using vibro technology) Size of width and depth 300 mm to 400 mm , thickness 100 mm, including laid over 20 mm thick cement mortar 1:3 and joints pointing with 1:2 cement mortar including provision of off sets at top edge for placing of covers etc. complete all as specified and directed
M & L 50 mm thick Cement concrete work rough finished as in plinth protection / sub base type C-1, 1:3:6 (20mm graded aggregates) including grooves , joints etc. filled with joint sealing bituminous compound etc. Complete .
M&L for vitrified tiles double charged/ full body (square/rectangular) polished, (dark and light shade combination design pattern and boarder as approved by GE) , area of each tiles exceeding 1.00 sqm but not exceeding 2.00 sqm of size (80mm X 2400mm & as approved by GE), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete including 15mm thick screed bed or bedding layer of mortar in cement mortar (1:4) etc. complete all as specified and as directed
M&L for vitrified tiles double charged (Square/ rectangular) polished, (colour, design & pattern as approved by GE) area of each tiles exceeding 1.00 sqm but not exceeding 2.00 sqm of size (80mm X 2400mm & as approved by GE), as in skirting, dado, vertical surface laid on 10 mm thick cement plaster in CM (1:3), set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tiles etc. Complete all as specified and as directed
Description of Work / Item(s)
Amount
Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) complete such as switches, ceiling rose, pendent holder, regulator and socket, light fittings etc to be measured separatly and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc complete all as directed.
Material and labour of point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm min dia and PVC conduit fittings such as tees, bends, elbow, reducers including cutting & chasing and FRLS PVC insulated unsheathed 1.5 Sqmm copper conductor mulistranded earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size with modular sheet for fixing modular switches/sockets etc for one light point / fans point controlled by one 1-way switch complete all as directed.
All as per srl item no. 2 here-in-before but with 1.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for One 3 pin socket outlet 5 amps on the same board complete all as directed.
All as per srl item no. 2 here-in-before but with 1.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for one 3pin socket outet point 5 amps on the independent board..
All as per srl item no. 2 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire independent board complete all as directed.
Material and labour wiring for circuit / submain wiring complete with 2x 1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and singlr core copper conductor cable ISI marked and including PVC conduit ISI marked of size 20 mm min dia in surface /recessed and PVC conduit fittings such as tees, bends, elbow, reducers including cutting & chasing and FRLS PVC insulated unsheathed 1x 1.5 Sqmm copper conductor mulistranded earth wire, connecting to common earth dolly complete all as directed.
S & F Modular switch 6 Amp, 1 way, 1 module size complete all as directed.
S & F Modular switch 16 Amp, 1 way, 1 module size with indicator lamp complete all as directed.
S & F modular socket two-in-one, 6 Amp universal type, 02 module size complete all as directed.
S & F modular Socket, 16 Amp, multipurpose shutter type, 02 module size complete all as directed.
S & F Modular bell push 6 Amp, 1 way, 1 module size complete all as directed.
Taking down of ceiling fan any type and size ,dismantling blades etc & Including deposited to MES store yard.
S&F BLDC (Brushless Direct Current) Ceiling Fan, 1200 mm suitable for regulator, sevice value (cmm/w) > 6.85, not less than Air delivery 215 cum/minute, voltage 220V,having full copper motor winding & ribbed 3 Nos A/M blades. The fan shall have BEE 5 star rating and making necessary electric connection of suitable PVC copper wire from ceiling rose to ceiling fan complete all as specified and directed.
Supply and fixing lamp holder ,PVC/Polycarbonate type with suitable for LED lamp, etc complete all as directed.
Supply and fixing Ceiling rose, insulated body, 3 terminal, 230 volts, 5 Amps complete all as directed.
Supply and fixing in replacement electric bell of DINGDONG type, 230 volts, single pole in thermoplastic range with 50 mtr for 5 sec and making all necessary connections complete all as directed.
Supply and fixing in replacement Modular AC Socket box including socket and with 25Amps SP MCB, C curve 230 Volts, 50Hz. Complete.
Supply and fixing engagement light fitting with 3 watt, 2x LED lamp ( red and green) including all electric connections complete all as directed.
S&F LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound not less than 10 watt & P.F> 0.9 & efficacy (Lm /w) >= 100 & CCT - 3000 to 6500K, cool/warm white as per site requirement complete all as specified and as directed.
Supply and fixing LED ceiling light fitting in round shape, recessed/surface type, housing made from engineering plastic with in built driver, heat sink with shatter proof opal shell of polycarbonate compound not less than 12 watt & P.F> 0.9 & efficacy (Lm /w) = 100 & CCT - 3000 to 6500K, ripple < 5% cool/warm white as per site requirement complete all as specified and as directed
Supply and fixing LED ceiling light fitting in round shape, recessed/surface type, housing made from engineering plastic with in built driver, heat sink with shatter proof opal shell of polycarbonate compound not less than 15 watt & P.F> 0.9 & efficacy (Lm /w) = 100 & CCT - 3000 to 6500K, ripple < 5% cool/warm white as per site requirement complete all as specified and as directed.
Supply and fixing surface mounting LED Integrated Aluminium batten luminarie polycarbonate co-extusion tube for not less than 20W LED light housing ,fixture should have minimum efficacy at system level > =120 lumens/watt,,life of fixture not less than 50k HRS,ripple<5% ,UGR< 19,minimum surge protection level of 4 KV ,CCT 4000-6500k with same lumens /w CRI >80,PF> .95,THD<10% @ 240V,AC . aN OPERATING VOLTAGE RANGE OF 140-270v including all connection upto ceiling rose complete all as specified and directed. LED tube light fitting, 20 watt ,230V wall mounting type and including all electric connections complete all as directed.
Supply & fixing in replacement of ventilating fan of size 250m sweep plastic body including louver and making all electric connections complete all as specified and directed and deposited the old to AGE (E/M) Store.
Supply and fixing surface/recess mounting 2x2 square flat panel ultra slim scoop LED light 36/40 W warm/cool white with driver/transformer etc suitable for Grid ceiling/Gypsum board/POP ceiling ,fixture should have minimum efficacy at system level > 2000 lumens,,life of fixture not less than 30k ,driver efficiency>85%,,minimum surge protection level of 4 KV ,CCT 4000-6500k with same lumens /w CRI >70,PF> .95,THD<20% @ 240V,AC . aN OPERATING VOLTAGE RANGE OF 120-270v including all connection complete all as specified and directed.
Taking down and refixing of 2'x2' Square flat panel suitable for Grid ceiling/Gypsum board/POP ceiling incl making electric connection complete as as directed.
S&F wall mounted fan 400 mm sweep, aerodynamic designed, air delivery ≥ 70 CMM, thermal over load protected motor, 3 blade white colour, 230 volts, 50 Hz, 1420 RPM with 90 degree oscillation and having speed & oscillation control by two pull cords system complete all as specified
S & F Modular white cover plate with frame 2 Module complete all as directed.
S & F Modular white cover plate with frame 3 Module complete all as directed.
S & F Modular white cover plate with frame 6 Module complete all as directed.
S &F Modular white cover plate with frame 12 Module complete all As directed.
S & F Modular metal flush box 1/2 Module complete all as directed.
S & F Modular metal flush box 3 Module complete all as directed.
S & F Modular metal flush box 6 Module complete all as directed.
S & F Modular metal flush box 12 Module complete all as directed.
S & F in replacement of Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed.
S & F MCCB incommer Distribution Board ( Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connection complete all as specified and as directed.MCCB and MCB will be measured seperately and paid.
S & F in replacement of MCB 'C' Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA of capacity 6 to 32 amps complete all as specified and directed.
S&F in replacement of MCB, SPN, 40 TO 63 Amp, C curve type 10 KA, 240 Volt. complete all as specified and directed.
Supply and fixing in replacement of MCCB4 pole ,415 V Adjustable type 160Amp with breaking capacity 25KA.
Supply laying and drawing submain wiring in and including 20mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 10 sqmm (Main cable and neutral ) and one run of IC x 10 sqmm ( as earth wire ) of multistranded copper conductor PVC insulated FRLS unsheathed cables of 1100 volts grade conforing to IS :694 OF 1990 COMPLETE INCLUDING CONNECTION ALL AS SPECIFIED AND DIRECTED.Note: 3 unit length of single core wire shall be measured & paid as one unit length.
Supply laying and drawing submain wiring in and including 20mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 4 sqmm (Main cable and neutral ) and one run of IC x 4 sqmm ( as earth wire ) of multistranded copper conductor PVC insulated FRLS unsheathed cables of 1100 volts grade conforing to IS :694 OF 1990 COMPLETE INCLUDING CONNECTION ALL AS SPECIFIED AND DIRECTED.Note: 3 unit length of single core wire shall be measured & paid as one unit length.
M& L for Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15 cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth lead of size 4 mm by means of galvnised nuts, bolts and washers. GI wire of 4 mm dia laid in 15 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor).
Supply and fixing of factory made powder coated cable tray ( in an approved shade ) perforating ladder type cable tray in tiers of the following size for carrying power/ control cable ( all tees,coupler , bends etc shall be factory made and of the same make) . Along with suitable length of 50x50x6 mm thick MS equal angle iron for horizontal support fix at every 1 mtr interval for carrying the tray in one/two/three tier fashion either on one side of the wall or both side of the wall or suspended from the ceiling SS anchor fastener of suitable size sealing will be provided for fixing the horizontal support with the ceiling and same will be weld with the vertical support members for holding the tray.Cost of all the required material with the related accessories to finish this work along with the equal angles to be
M& L cable ducts size of 50x150x 40x2mm thick (Perforated type)
M& L cable ducts size of (wxh) 40x300x2mm thick (Perforated type) .
S&F of energy efficient LED fittings not less than 45 Watt & THD < 10% & P.F> 0.9 & efficacy (Lm /w) > 120 & CCT - 3000 to 6500K, ripple < 5% LED 6K suitable for building security light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as specified and as directed.
Supply and fixing in street light fitting bracket, 1mtr long made out of galvanized iron pipe of 25mm dia size light grade complete with nut, bolts,Clamps complete all as directed.
M & L in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 Core specified and directed at site by Engineer-in-Charge.
M & L in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4Core specified and directed at site by Engineer-in-Charge.
Excavation in trenches in loose/soft soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out including forming bottom surface for laying LT cable as specified and directed at site by Engineer-in-Charge.
M&L for sand cushioning to under ground cable provided with layers of sand(8 cms deep before laying the cable and 15 cms deep after laying) complete allas specified and directed at site by Engineer-in-Charge.
Removing exccavated soil not exceeding 50 mtr and depositing wheredirected at a level not exceeding 1.5 mtr above the starting point complete as specified and directed by the Engr-in-charge.
Returning filling in soil including spreading, levelling, watering and well rammingin layers not exceeding 25 cm complete as specified and directed by the Engr-in-charge.
Supply and laying burnt bricks class - B for protection of cable complete all asspecified and directed at site.
S&F worm white indoor type long coverage, superior light output, robust material LED strip complied with IP65 making it more durable and water proof with colour temp 3000k complete all as specified & directed
M/S Chhavi Constructions Co (BID ID -3136754)
M/S Yamin (BID ID -3136821)
A R construction (BID ID -3144045)
M/s M M BAHL (BID ID -3144501)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3129903)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3129903)
M/S Chhavi Constructions Co (BID ID -3136754)
A R construction (BID ID -3144045)
M/S Yamin (BID ID -3136821)
M/s M M BAHL (BID ID -3144501)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .