Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹14.4 L+₹51,107 (3.68%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-AOC L2 BIDDER | |
| 3 | L3₹15.2 L+₹1.3 L (9.44%)Rejected-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-AOC L3 BIDDER |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
11 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Amla
GE AF Amla, Betul Dist 460553 (MP
REPAIR/ MAINTENANCE OF LT DISTRIBUTION SYSTEM AND CONNECTED WORKS AT AFS AMLA
2021_MES_459651_1
8445/E8 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE AF Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹40,000
Yes
7 Sept 2021
14 Jul 2021
13 Aug 2021
14 Jul 2021
11 Aug 2021
28 Jul 2021
60 days
Amount
Taking out carefully PVC insulated sheathed armoured stranded aluminium conductor LT underground cable (single, 2, 3, 3.5 or 4 core) from trenches/ ducts/ walls etc., including necessary dismantling, demolition and disconnecting cables from existing power line complete all as specified and as directed for the following sizes of cable:- Note :- (i) Earth work excavation, returning filling and disposal shall be measured & paid separately under respective items. (ii) The surface disturbed during dismantling/demolition shall be made good by contractor at his own cost by using 1:2:4 type B1 concrete (or) in CM 1:4 which deemed to be included in the contractor quoted rate.
10 sq. mm, 2 core
16 to 25 sq. mm, 3.5 core
50 to 95 sq. mm, 3.5 core
120 sq. mm, 3.5 core
Laying only PVC insulated, sheathed, armoured heavy duty electric UG cable with multistranded aluminium conductor LT 1100 Volts grade laid in trenches/passing through pipe/duct or fixed to wall, panel etc., and connecting up including testing complete all as directed for following size of cables:- Note :- (i) Serviceable cables obtained from Item No 1.01 to 1.04 shall be re-used
10 sq. mm, 2 core
16 to 25 sq. mm, 3.5 core
50 to 95 sq. mm, 3.5 core
Supply lay & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for the following size of cable:-
2 core, 10 Sq. mm
3.5 core, 50 Sq. mm
3.5 core, 95 Sq. mm
3.5 core, 120 Sq. mm
4 core, 16 Sq. mm
4 core 25 Sq. mm Notes for Item No 2.01 to 3.06:- (i) The minor parts such as clamps, screw etc.,, required for fixing cables on wall, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate. (ii) Earth work excavation, returning filling and disposal, protection pipe & joint kit shall be measured & paid separately under respective items.
Surface dressing not exceeding 15 cm deep in hard/ dense soil by clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and removing rubbish upto a distance of 50 metres outside the periphery of the area complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0m in depth; for laying cables and getting out in hard/dense soil complete all as specified and directed.
Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Supply and spread dry river washed sand free from foreign material in trenches for cable cushioning all as specified and directed. Note:- For payment purpose only punned thickness of sand will be measured & paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm all as specified and as directed.
Material and labour for Galvanised steel tubing, light grade laid in trenches/ fixed to poles, walls etc as a protection for service cable including removing existing old unserviceable rusted pipe complete all as specified and directed for the following size of pipe:-
40mm dia bore
50mm dia bore
80mm dia bore Notes for Item No 11.01 to 11.03:- (i) The minor parts such as clamps, screw etc.,, required for fixing pipe on wall, pole, panel etc., shall be provided by the contractor at his own cost which is deemed to be included in the contractor quoted rate.
Dismantling of concrete pole/ strut, any size embedded in cement concrete foundation etc., and setting aside for reuse within 50 metres or disposing off MD land complete all as directed.
M&L for providing horizontal bore hole of dia upto 120mm below road/hard standing surface for the length upto 10 Metre and inserting GI/PVC pipe into the bore hole as cable protection complete all as specified and as directed. Note:- Cable protection pipe shall be measured and paid separately under relevant item.
Supply & erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.50 metres long) including appllication of two coat of aluminium paint over one coat of red oxide zinc chrome primer above ground level and two coat of bituminous paint below ground level complete all as specified and directed.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations, filling and mass- concrete, complete all as specified & directed.
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping and the like including necessary form work etc, complete all as specified & directed.
Demolition of brickworks as in pedestal of LT panel, feeder pillar-box etc., built-in cement mortar and disposing of debris complete all as specified and directed.
M&L for brick work with old size fly ash bricks having minimum compressive strength of 75 kg/cm. sq, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 10 mm thick Cement Mortar 1:6 over brick or concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L for plate earthing with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 25 x 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of HT/LT equipment’s etc at the other end including 32 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified & directed. Note :- (i) Earthing resistance required in earthing shall less than 1.0 Ohms after completion of work. All earthing shall be tested by the contractor in presence of Engr-in-Charge. Test result shall be recorded and signed by the contractor and Engr – in- Charge. If contractor fail to achieve the above result the same shall be rectified by the contractor without any extra cost to Govt. The earthing result will be required maintaining up to end of defect liability period of one year and if any variation found in earthing result during defect liability period same will be intimated to the contractor by Engg-in-Charge and contractor shall rectify the same. The quoted rates shall be deemed to include for above said provision. (ii) Quoted rates shall be deemed to be included for earth strip with protection pipe up to 7.5 length.
Supply & fixing in repairs 25x4mm galvanised iron strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking out old one complete all as specified and directed.
Supply & fix in repair out door type straight through joint heat shrinkable type for LT XLPE / PVC 1100 volt grade cable and connecting the cable including testing on load complete all as specified & directed for the following size of cables:-
LT cable size 3.5/4 X 25 to 50 Sq mm
LT cable size 3.5/4 X 70 to 150 Sq mm
Supply & fix in repair Junction box of size 300mm x 450mm x170mm with Aluminium bus bar rating three phase 150 Amp and neutral 75 Amp, IP 65 having provision for metric knockouts for cable entry up to 70 Sq mm including Aluminium painted GI clamps 30x 4mm thick with nuts, bolts, washers and testing complete all as specified and directed. Make:- Hensel cat no K-7004
Supply & fix in repair Junction box of size 255mm x 355mm x122mm, with 4 terminal of rating 63 Amp, IP 65 having provision for metric knockouts for cable entry up to 50 Sq.mm including Aluminium painted GI clamps 30x 4mm thick with nuts, bolts, washers and testing complete all as specified and directed. Make:- Hensel cat no DK-5054G
Supply & fix in repair Junction box of size 205mm x 255mm x112mm with 4 terminal of rating 32 Amp, IP 65 having provision for metric knockouts for cable entry up to 25 Sq mm including Aluminium painted GI clamps 30x 4mm thick with nuts, bolts, washers and testing complete all as specified and directed. Make:- Hensel cat no DK-2525G
Supply & fix in repairs MCCB, 415 Volts, 4 pole with thermal magnetic release type of the following ratings:-
MCCB 250 Amp, 415 Volts, 4 pole, breaking capacity 36 KA
MCCB 200 Amp, 415 Volts, 4 pole, breaking capacity 25 KA
MCCB 160 Amp, 415 Volts, 4 pole, breaking capacity 16 KA
MCCB 100 Amp, 415 Volts, 4 pole, breaking capacity 16 KA
Supply and fix in repairs ACSR Overhead conductor of any size, to be fixed on pole/ jumper connections/ on insulator by means of necessary binding with 14 SWG including taking out old one complete all as specified and directed. Note:- The ACSR wire supplied by contractor shall conform to IS 398-1976 part II
Material & labour for painting of steel poles of 8.5/9.0 m height with two coats of aluminium paint over a coat of red oxide primer including painting of channels, cross arm angles etc., on pole after necessary preparing of the surface by removing dust, rust etc. complete all as specified and as directed.
Supply and fix in repair cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including taking out old one complete all as specified and directed.
Restringing, tightening of ACSR conductors of 3 phase 3 wire system, measured as single run on poles including necessary aluminium binding wire, connectors, etc, as in fixed in repair complete all as specified and directed.
Restringing, tightening of ACSR conductors of 3 phase 4 wire system measured as single run on poles including necessary aluminium binding wire, connectors, etc, as in fixed in repair complete all as specified and directed.
Restringing, tightening of ACSR conductors of single phase 2 wire system measured as single run on poles including necessary aluminium binding wire, connectors, etc, as in fixed in repair complete all as specified and directed.
Material and labour for cutting/ trimming tree branches coming on overhead line LT/ HT lines minimum 02 metre space all around the conductor including disposing off trimmed branches upto lead of 50m apart complete all as directed.
Trimming of trees (of any dia) & cutting wild grasses, unwanted vegetation etc form pole/stay including cleaning of creepers climbed on poles and stay cleaning of nest of birds from poles, angles, channels complete (size of root cleaning 90x90cm around pole/stay) complete all as directed by Engr-in-Charge
Supply & fix in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height 65 mm dia for 1100 volts grade including taking out old one complete all as specified and directed.
Material and labour Stay assembly complete with accessories as shown in electrical plate No. 1 of SSR part I; comprising of 7/3.15 mm galvanised mild steel stranded stay wire of required length fixed to pole with and including FI clamps of size 50X6 mm, bolts, nut, washers, stay rod 20mm dia 2.15 metres long, stay bow with nuts bolts washers, GI steel plate 230X230X60mm including loop insulator over all dimension 140mm clearance of hole 25.5mm including taking down old rusted stay assembly complete all as specified and directed.
Supply & fix in repairs line separators for OH line PVC insulated and PVC nut and bolt hook up/spiral suitable for single phase 2 wire system including taking out old one complete all as specified and directed.
Supply & fix in repairs line separators for OH line PVC insulated and PVC nut and bolt hook up/spiral suitable for 3 phase 4 wire system including taking out old one complete all as specified and directed.
Material & labour for marking of pole number with black luminous words on luminous yellow round sticker as per sample complete all as specified and as directed.
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Shri Sai Enterprises
Paragon Electrotechnics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .