Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.2 L+₹2.5 L (8.38%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹28.2 L
EMD Value
₹56,320
Closing Date
15 Oct 2022, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
SPECIAL REPAIRS TO WATER DISTRIBUTION SYSTEM FROM BWSSB LINE TO CQAE WE, UG SUMP AT CQAE WE BANGALORE AND PROVISION OF ROOF SHED FRO VEHICLE PARKING AT FWTF IN TECHNICAL AREA AND WORK SERVICES FOR EXTENSION OF EXISTING STAGE IN BLDG NO P-314 AT AFSY
2022_MES_538602_2
8979/E8
Open Tender
Civil Works
Item Rate
180 days
AF Stataion Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹56,320
Yes
9 Mar 2023
17 Sept 2022
17 Oct 2022
17 Sept 2022
15 Oct 2022
29 Sept 2022
Amount
Taking down 100mm CI pipe line including disconnecting pipes and fitting complete all as specified and directed.
Taking up sluice valve / NRV of any size from pipe line complete all as specified and directed.
Supply, laying, testing commissioning centrifugally cast ductile iron pipes conforming to IS-8329:2000, 150mm bore dia with socket & spigot ends, class LA including flexible push on joint in any length laid in trenches all as specified and as directed by Engr-in-charge.
Supply and fix sluice valve flanged of class 1.6 PN, 150mm (6") dia of CI/DI body, both ends flanged duly drilled, ISI marked with IS-14846-2000 having stainless steel spindle all as specified and as directed.
Supply and fix MS pipe ERW steel including specials, nominal dia 150mm as per IS 3589 (1981) thickness 6mm including both side flanged, nut, bolts gasket fittings complete all as specified and directed by Engr-in-charge.
Supply and fix Reflux valve with by pass arrangement, 150mm (6") dia complete all as specified and as directed.
M&L for DI/MS special and fittings as per IS spigot and socketed pipes for water mains/ branches lines such as bends (any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, `Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs including connecting pieces one end flanged and other socket or spigot and bell mouth pieces suitable for run lead joint, run lead upto 300 mm bore complete all as specified and directed.
Cutting the existing road/ hard standing/ chequered cement concrete tiling/ PCC flooring etc to required depth for laying of CI/ DI/ GI pipe 150/ 100/ 80/ 50/ 40/ 25 mm dia including returning filling with excavated earth and making good disturbed road / hardstanding top surface with 200mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate complete all as directed by Engr-in-charge.
M&L for construction of PCC block walling valve pit of size 900mm x 900 mm (internal dimension) with precast cement concrete block of PCC (1:3:6) type C-1 using 20mm graded stone aggregate and 10mm thick rendering in CM 1:4 on internal and exposed external surfaces with and including 40 x 40 x 6mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less than 3mm with locking arrangement and 1 No 50mm size 4 lever lock with key in duplicate of make Navtal or equivalent, including painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth and getting out in hard/ dense soil for laying of CI/DI/GI pipes complete all as speified and directed.
All as per item No 10 above but exc.1.5mtr but not exc.3 mtr in depth complete all as specified.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and as directed.
Removing excavated surpus soil n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supply and laying 250 mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars.
Excavating in post holes (or similar holes) each n exc 0.50 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm
M&L for PCC 1:3:6, type C2 using 40mm graded stone aggregate as in fondation, filling and mass concrete.
M&L for PCC 1:2:4, Type B2 using 40mm graded stone aggregate as in foundation, filling and mass concrete.
S&F ERW or induciton butt weld MS tube black confroming to IS-1161-1979 grade Yst 240 including fabrication and erection
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connected plate of Fe 410-W (Gde E 250 Quality A)
S&F MS plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment.
S&F pre painted galvalume alminium Zinc coating based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall fixed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint on surfaces including priming with red oxide zinc chrome primer complete all as specified and as directed.
Removing excavated materail exc 1.5Km but exc 5Km and depositing where directed in soils
Dismantling floor,hearth or wall tiling including cement mortar bedding(but not backing),removing serviceable tiles to store and rubbish off the premies complete all as specified.
M&L for sand filling under floors or in foundations inclduing watering and consolidation.
Fixing only Machine pressed precast concrete interlocking paver block of any shape and size conforming to IS-15658-2006 of 60mm thickness,M-35 Grade.
Dismantling boarding of any description, fixed in any position with screws
Demolition of Cement concrete (Un reinforced) of any description and in any position not otherwise specifically provided for complete all as directed.
M&L for PCC 1:4:8, type D2 using 40mm graded stone aggregate as in foundation all as specified
M&L precast cement concrete solid block masonry exc 10cm width with PCC 1:3:6 Type C1 using 20mm graded stone aggregate set in CM 1:4 complete all as specified.
M&L for 25mm thick Cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in floor/sub floor complete all as specified.
M&L for 100mm thick Cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate as in floor complete all as specified.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing etc, over 20mm thick Screed bed or bedding layer of mortar in cm 1:6 complete all as directed
M&L for Providing edge moulding to 18-20mm thick granite stone of counters vanities, floors, steps etc. including machine polishing to edge to give high gloss finish etc. complete
M&L for 15mm thick rendering in CM 1:6 on concrete/ brick wall surfaces finished even and smooth without using extra cement, complete all as specified and as directed
M&L for 2nd class hard wood Plain fillets, exc 13.00 and n exc 25 sqcm in square, rectangular or triangular in section, wrought, secured with screws complete all as directed.
Taking down existing railing of any description and size and refixing in the new position including grouting, cleaning, polishing etc complete all as directed.
Formwork to soffits of suspended slabs for fair finished surfaces of concrete such as roof slabs,floor slabs,landings and similar work,curved of any pattern not exceeding 200 mm thick (Horizontal or sloping) complete all as directed.
Formwork to edges of concrete flats,treads,breaks in floors,window cills,concrete railings,openings in concrete walls,floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls,horizontal or sloping and similar work exc 10cm but n exc 20cm complete all as specified and as directed.
M&L for Reinforced Concrete type B1,1:2:4 using 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors,roofs,landings,balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips,
M&L for Mirror polishing on existing marble/ granite/ Kota stone/ stone work where ever required to give high glossy finish complete.
M&L for 12mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
M&L for 18mm / 19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
S&F auto concealed hydraulic steel spider/butterfly hinges suitable for cupboards complete all as directed.
S&F 100mm size handles of stainless steel fixed with screws complete all as specified.
S&F aluminium anodized barrel tower bolt of extruded section 150 mm length.
S&F brass locks,2 lever for cupboard,grade I,size 50mm.
Taking down the unserviceable point wiring (light, fan,socket or power) complete with fittings such as switches, sockets, ceiling roses, pendent regulators, sockets etc any light points and making good distrubed surfaces of walls and floors etc. complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable DBs, with MCBs and Main switches.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) single core PVC insulated heavy duty ISI Marked FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through in and including new PVC concealed conduit in existing brick/stone wall for concealing conduit and provision of PVC Insulated heavy duty ISI marked unsheathed copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly for one socket 5 amp on independent board.
All as per item No 50 above but wiring with 2.5 sqmm FRLS copper cable including earth continuty conductor with 2.5 sqmm FRLS copper cable for one 6 pin 15 Amps socket outlet on independent board controlled by 15 Amps switch. Note: (a) The flush metal box and cover plate with frame for fixing modular switch/socket/regulator etc shall be measured and paid sepertately under relevant items of the schedule.
Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete.
Supply and fix modular type Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix modular type Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix Modular switch 1 way 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame, 3 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame, 8 module ISI marked complete all as specified and as directed.
Supply and fix modular flush metal box 3 module ISI marked complete all as specified and as directed.
Supply and fix modular flush metal box 8 module ISI marked complete all as specified and as directed.
M&L for sub-main wiring with four runs of 6 sqmm unsheathed PVC insulated, single core cable with copper stranded conductor in and including suitable PVC Conduit with 6 sqmm copper earth wire after taking out the existing sub-main wiring, etc. Note: 4 runs of cable and one run earth wire and conduit shall be measured as one length.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix MCB Single pole and Neutral, 230 volts, 6 to 32 Amps, 'C' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fix MCB Single pole and Neutral, 230 volts, 40 to 63 Amps, 'C' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair MCB Single pole, 230 volts, 6 to 32 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
chowdeshwariconstructionco
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .