| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 LAccepted-AOC 3 2 G NO 1 ROSHAN VIHAR EAST SADATPUR NORTH EAST DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.1 L+₹16,142 (1.47%)Rejected-Finance 10 SANJAY HSG SOCIETY RACCA COLONY SHARANPUR ROAD NASHIK 422 002 | NASHIK | MAHARASHTRA | 422002 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹11.5 L+₹59,813 (5.46%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹11.8 L+₹85,919 (7.85%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹11.8 L+₹86,679 (7.92%)Rejected-Finance ALPHA HOUSE PLOT NO 29 AGP P10 ASHWIN SECTOR NEW CIDCO NASIK 422 009 | NASHIK | MAHARASHTRA | 422009 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹14.6 L
EMD Value
₹29,500
Closing Date
19 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2021_MES_432497_1
GE/NRC/8807/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Nasik Road
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Nasik Road
₹29,500
Yes
7 May 2021
23 Mar 2021
23 Apr 2021
23 Mar 2021
19 Apr 2021
5 Apr 2021
60 days
Amount
Dismantling asbestos cement (corrugated,semi corrugated)sheets in roof covering
S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and making good to wall and roof joint.
S & F Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275
Demolition of cement concrete (unreinforced) of any description and any position not otherwise specially provided for
M &L for 75mm thick PCC 1:4:8 Type D2 (40 mm graded aggregate)as in sub floors, sub bases, floors and paving concrete as directed by Engineer in Charge
M & L for Screed bed or bedding layer of cement mortar 20 mm thick for laying floors finishes in cement mortar 1:6.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick( sqare or rectangle) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
Demolition of brick work or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillers etc but including ashlar facings, dressed stone work and precast concrete articles
M & L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 with old size bricks.
M&L for Random rubble mesonry, uncoursed well bonded bedded and solidly hearted built in CM 1:6 complete all as specified and directed.
Ditto as Item no-10 but except stones
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, Hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 20mm as specified, of random rubble walling,uncoursed or brought upto courses
M&L for keyed pointing of CM 1:4 to random or polygonal rubble;uncoursed or brought upto courses complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including raking out joints hacking for keys scrubbing down with water etc. including removing all the debris out side MD land
M&L for rendering 15 mm thick cement plaster on than fair faces of brick work or concrete surfaces in CM 1:4 rendering is to be finished even and smooth without using extra cement adding water proofing compound 3% by weight of cement (water proofing compound shall be measured and paid separately)
M&L for rendering 15 mm thick (1: 6) on stone masonry or other than fair faces of brick work surfaces finished even and smooth without using extra cement
M&L for rendering 10 mm thick (1: 6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement
Supply only intergral water proofing compound
Taking down chowkat or frames with shutters (without taking off shutters from the frame not exc. 1.5 Sqm each.
Taking down chowkat or frames with shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4 sqm each.
S&F MS butt hinges 100mm size medium weight complete all as specified and directed
S&F aluminium alloy barrel tower bolt 150 mm long
S&F 150 mm aluminium alloy handels cast/plate type
S&F II nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, sup-plied and fixed
S&F IInd class HW 35mm thick plain framed factory made panelled shutters (two panel) with lock rail, panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 (Part I) Kiln, Seasoned and chemically pressure treated.
S&F (IInd class hard wood) Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (divided in to square with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mi-tred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Sec-tion 8, cla-use 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
S&F aluminium alloy anodised sliding door bolt 300mm long with hasp & staple (bolt type) and fixing chops of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast alluminium alloy abd fixed
M&L for preparating newly plastered surfaces of walls and applying two coats of OBD over one coat of chalk whitning, prepatory to distempering complete all as specified and directed.
M&L for cement concrete type C2 1:3:6 (20 mm graded aggregate) 50mm thick in Plinth Protection complete all as specified and directed.
M&L for cement concrete type C2 1:3:6 (40 mm graded aggregate) in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
Cutting holes exceeding half brick but n. exc full brick depth in brick walls in stone/Brick walls built in cement mortar or in cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4
S&F aluminium anodised powder coated (min thickness 50 microns) frame for doors, windows, ventilators, complete all as specifed and directed
S & F Aluminium anodised powder coated window and ventilator shutter, sliding type without sash bar, alumn section section weighing not less than 0.55 kg per mtr incl necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specifed and directed
S&F Sheet glass ordinary quality 4.0 mm thick exc 0.5 sqm each pane with Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specifed and directed
S&F interlocking aluminium powder coated snap grid consists of main Tee runners of size 38mm x 24mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 24mm x 27mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 24mm x 27mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 22mm x 1.5mm and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and S&F non asbestos cement building board 4mm thick of make E board classic of M/s Everest industries Ltd or equivalent make as approved, “in ceiling fixed with screw as per manufacturer instruction”
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm complete all as specifed and directed
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft /loose soil
Hardcore of guage n exc 63 mm of brokan stone or boulders, deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to true surface
S&F Providing precast cement concrete type C1, 1:3:6 (20mm graded stone aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, Kerb stones etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match with CM 1:6 complete all as specified and directed.
M&L for rubber moulded machine pressed precast inter locking paver block with gray cement any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-25 grade laid on 30mm thick stone dust cushioning laid dry to the profile complete all as specified and directed
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc ( note -(1) credit for above items should be made as per conditions separately. (2) old servicable switch/socket/regulater/switch-socket/call bell/bell push shall be deposited to AGE E/M yard and reused against apropriate items, all as specified and directed by Engr-in-Charge)
Taking down unserviceable/partly serviceable light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes.(NOTE- old serviceable fitting shall be deposited to AGE E/M yard and reused against apropriate items, all as specified and directed by Engr-in-Charge)
Taking down and hanging during point wiring of ceiling fan/exhaust fan of any size and sweep in proper manner and making connection withT 3 core copper cable all as per specified and directed by Engr-in-Charge
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
M & L for Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate. (a) One light point controlled by one, one way switch
All as per item No.47 above but One ceiling /exhaust fan point controlled by one switch and regulator
All as per item No.47 above but One 3 pin 5 amp socket out point on the same board with other switches.
All as per item No.47 above but One3 pin 5 amps socket out let point on independent board
S &F Switch piano flush type single pole one way 5 amps.
S &F Socket out let 2 in one, 5/3 pin 5Amp
S &F Switch socket combination 5 Amps 5 pin flush type
S &F Ceiling rose, surface bakelite 65x50 mm three terminal
S &F Electronic regulator 100/120 Watt step type
S&F 20 Watt LED Tube Light (4 feet) comprises of extruded Strip in thermally conductive material & extruded housing in Optically efficient material milky white with inbuild split LED driver at the end of LED tube & FR grade engineering plastic End.
S&F 20 Watt LED Tube Light (4 feet) comprises of extruded Strip in thermally conductive material & extruded housing in Optically efficient material milky white with inbuild split LED driver at the end of LED tube & FR grade engineering plastic End.
Refixing of tube light from exisiting position to new position as required at site all as directed and specified . (Note:- The old serviceable fittings will be used as removed against item No-2 above)
Refixing of wooden/PVC rectangular block for mounting, switches, sockets,fan regulator, call bell, bell push etc. with 3 mm thick plastic laminated sheet cover/helum sheet of ISI mark as required on ground including casing capping /conduit of any size, all as specified and directed by Engr-in-Charge. (The old serviceable material will be used as removed against item No-1 above)
S & F 15 Watt LED streetlight fitting luminaire comprises of pressure die cast aluminium housing powder coated in silver grey and toughnedglass. This luminaire is recommended for illuminating access roads, Garden ways, small streets etc. IP65 protection , including coneecting up with 2/3 core flexible coppper conductor cable , compete all as specified and directed by Engr-in-Charge.
Fabrication,supply & fixing of GI pipe bracket up to 40 mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for any type and size of LED security light fitting
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC CASING CAPPING not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC casing capping shall be measured as one unit. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS 11405.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
M/S SAMEER SUBHASH PATANI
M/s. JBSR ENTERPRISES.
Vishal Constructions
Alpha Construction
M/S K. K. Construction
SVT ENGINEERS AND CONTRACTOR.
SHILPVED
A V S Builders
SAGAR JANJALE CONSTRUCTION
Bidder Name
Vishal Constructions
A V S Builders
M/S SAMEER SUBHASH PATANI
SVT ENGINEERS AND CONTRACTOR.
M/S K. K. Construction
Alpha Construction
Anand Trading Co
SAGAR JANJALE CONSTRUCTION
M/s. JBSR ENTERPRISES.
SHILPVED
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .