Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.3 CrRejected-Finance NO 83 THAMMAIAH GARDEN ABBLIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.3 Cr | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.4 CrRejected-Finance 121004 | ₹1.4 Cr | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.4 CrRejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹1.4 Cr | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.4 CrRejected-Finance WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹1.4 Cr | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL ENTERPRISES L4 | RAMESH BABU CO L1 | devan enterprises L6 | Neptune Engineers and Builders L3 | M/S Shiv Shakti Enterprises L5 | M/S SRI BALAJI ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and install in repair three phase 440V automatic AC load manager suitable for 4.5TR vertical type split AC for auto on/off of 3 Nos AC complete with timer,contactor,Internal wiring etc. including connection of incoming and out going cables complete all as specified and directed. Make: Universal Refrigeration and Engineering or equvalent | 1 | Each Job | 54,400 ₹54,400 | 51,750 ₹51,750 | 54,200 ₹54,200 | 58,500 ₹58,500 | 60,000 ₹60,000 | 61,500 ₹61,500 |
| 2.00 | Material and labour for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance along with blower assembly filter and other components including checking electrical connections complete all as specified and as directed. | 2 | Each Job | 1,500 ₹3,000 | 1,280 ₹2,560 | 1,200 ₹2,400 | 1,450 ₹2,900 | 1,300 ₹2,600 | 1,400 ₹2,800 |
| 3.00 | Material and labour for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections complete all as specified and as directed. | 2 | Each | 3,200 ₹6,400 | 3,240 ₹6,480 | 3,200 ₹6,400 | 3,250 ₹6,500 | 3,100 ₹6,200 | 3,200 ₹6,400 |
| 4.00 | Taking out 3 phase tower AC complete for repair / servicing and overhauling of capacity 4.0 TR Tower type AC after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc. and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed.
Note :-(i) Refrigerant gas shall be measured and paid separately under respective item of BOQ. | 4 | Each Job | 2,500 ₹10,000 | 2,412 ₹9,648 | 2,300 ₹9,200 | 2,352 ₹9,408 | 2,400 ₹9,600 | 2,500 ₹10,000 |
| 5.00 | Supply and fix PCB (circuit plate) of in-door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed. | 2 | Each | 5,000 ₹10,000 | 4,920 ₹9,840 | 4,100 ₹8,200 | 4,982 ₹9,964 | 4,000 ₹8,000 | 5,000 ₹10,000 |
| 6.00 | Supply and fix PCB (circuit plate) of out door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed. | 2 | Each | 3,500 ₹7,000 | 3,760 ₹7,520 | 4,100 ₹8,200 | 3,650 ₹7,300 | 4,000 ₹8,000 | 3,200 ₹6,400 |
| 7.00 | Supply and fixing Hermetic sealed/Rotory new compressor for 4.0 TR Tower AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of 4.0 TR Tower AC and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. | 1 | Each | 1,500 ₹1,500 | 46,700 ₹46,700 | 1,300 ₹1,300 | 1,450 ₹1,450 | 1,400 ₹1,400 | 1,300 ₹1,300 |
| 8.00 | Removing the window/ split type AC of 1.5/ 2 ton capacity of any make from any location for carrying out servicing complete as and when directed and installing back at original location, testing and commissioning complete all as specified and directed.
Note :- The rate of following deemed to be included in quoted rate :-
a) Cleaning the body, evaporator and condenser with detergent, combing the pins and flushing with air blower
b) Checking electrical connection, cleaning, Greasing, oiling, fan/blower motor, cleaning of air filter with blower
c) Wrapping suction and discharge pipe with foam insulation and white roll ,changing drainage pipe when necessary
d) The unit rate quoted by the tenderer inclusive for Removing, servicing, installation, commissioning and testing of all equipment’s, tools and plants, and back in on final position complete
(e) The work shall be done by a specialized team of Engineer/Technicians of OEM.
(f) Spares will be measured and paid separately.
(g) Refrigerant gas will be measured & paid separately. | 120 | Each Job | 1,300 ₹1.6 L | 1,194 ₹1.4 L | 1,300 ₹1.6 L | 1,352 ₹1.6 L | 1,500 ₹1.8 L | 1,250 ₹1.5 L |
| 9.00 | Supply and fixing Filter (in replacement) suitable for split type Air Conditioner of any make upto 2 TR capacity, including taking down existing one complete all as specified and directed. | 18 | Each | 400 ₹7,200 | 600 ₹10,800 | 420 ₹7,560 | 456 ₹8,208 | 415 ₹7,470 | 450 ₹8,100 |
| 10.00 | Supply and fix Over load relay (in replacement) suitable for split type Air Conditioner of any make up to 2.0 TR capacity, including taking down existing one complete all as specified and directed. | 15 | Each | 390 ₹5,850 | 328 ₹4,920 | 350 ₹5,250 | 425 ₹6,375 | 380 ₹5,700 | 350 ₹5,250 |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
8 May 2026, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF VARIOUS TYPE OF ACS COOLING SUMMER APPLIANCES EXTERNAL ELECTRICAL DISTRIBUTION SYSTEM PERIODICAL SERVICING INSPECTION OF VARIOUS EARTHING INFRASTRUCTURE AND CERTAIN MISC EM WORKS AT AFTC 2 DC AREA CQAE WE AND AFS JALAHALLI
2026_MES_759950_1
8305/E8
Open Tender
Civil Works
270 days
Garrison Engineer M AF Jaalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.1 L
Yes
5 Jun 2026
10 Apr 2026
15 May 2026
10 Apr 2026
8 May 2026
1 May 2026
10 Apr 2026 - 17 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Supply and install in repair three phase 440V automatic AC load manager suitable for 4.5TR vertical type split AC for auto on/off of 3 Nos AC complete with timer,contactor,Internal wiring etc. including connection of incoming and out going cables complete all as specified and directed. Make: Universal Refrigeration and Engineering or equvalent | - | Each Job | - | - | |
Material and labour for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance along with blower assembly filter and other components including checking electrical connections complete all as specified and as directed. | - | Each Job | - | - | |
Material and labour for blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections complete all as specified and as directed. | - | Each | - | - | |
Taking out 3 phase tower AC complete for repair / servicing and overhauling of capacity 4.0 TR Tower type AC after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc. and also connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed.
Note :-(i) Refrigerant gas shall be measured and paid separately under respective item of BOQ. | - | Each Job | - | - | |
Supply and fix PCB (circuit plate) of in-door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed. | - | Each | - | - | |
Supply and fix PCB (circuit plate) of out door unit of 4.0 TR Tower type AC complete including taking down existing one complete all as specified and directed. | - | Each | - | - | |
Supply and fixing Hermetic sealed/Rotory new compressor for 4.0 TR Tower AC capacity including disconnecting the electrical and refrigerant connection of defective sealed unit of 4.0 TR Tower AC and connection of all pipe line & charging of refrigerant and testing complete including taking down existing one complete all as specified and directed. | - | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
8305GENPAGE.pdf
Tender Documents • 0.55 MB
BOQ_851210.xls
BOQ • 0.49 MB
8305PS.pdf
Additional Documents • 0.90 MB
Download all tender documents and submit your bid