Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹6.7 L+₹33,689 (5.31%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹6.8 L+₹44,799 (7.05%)Rejected-Finance | L3 | Rejected-Finance Higher bid value |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
31 Jan 2022, 6:00 pmClosed
GE AF PURNEA
GE AF PURNEA, P.O - CHUNAPUR AIR FIELD, DIST- PURNEA BIHAR, PIN CODE 854303
REPAIR/MAINTENANCE OF AC, WATER COOLER, REFRIGERATOR AND ITS CONNECTED ITEMS AT MOUZA DALAN AND SIRSA AREA AT ARMY STN KATIHAR UNDER GE AF PURNEA
2021_MES_470702_2
8946/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
GE AF PURNEA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF PURNEA
₹12,000
Yes
8 Feb 2022
17 Jan 2022
1 Feb 2022
17 Jan 2022
31 Jan 2022
18 Jan 2022
Amount
M&L for servicing of 1.5/2.0TR capacity window/split type AC disconnect from electric connection and open suction & dicharge pipe from outer unit , such as removing/ scrach dust with iron brush, cleaning condessor unit, compressor, cooling coil/cleaning of fan blade/ cleaning of filter of inner unit etc, including (check thermostate, starting capacitior,running capacitor) with water & air blower, at the site and reinstall at the same place including Re-filling of refregerent Gas as required complete all as specified and as directed.
Taking down/up defective AC (Window/Split Type) 1.5 TR capacity, transportation from MES Store Yard/Site to workshop and back including re-fixing /re-installing after taking out defective/burnt rotary type compressor sealed unit including flushing of condenser and charging with required quantity of appropriate refrigerant gas including re-connection of electric connections, functioning AC complete in all respect and testing, complete all as specified and as directed. Notes for Item No 1 to 3:- (i) Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit. (ii) Refreigerant gas shall be measured and paid separately under relevant items as required to fill as per requirement/manufacturer instruction excluding measurement of gas filled by OEM).
All as per Item No. 2 above but AC (Window/Split Type) 2.0 TR Capacity, complete all as specified and as directed.
Supply only new compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR window type AC, ISI marked from authorised dealer, for fixing against defective parts of AC taking down under respective item complete all as specified and as directed.
Supply only suitable capacity/ model condensing coil unit copper for window type AC 1.0 Ton/1.5 Ton/ 2 Ton capacities ISI marked for fixing against defective parts of AC taking down under respective item complete all as specified and as directed.
Supply only condensing coil unit for split type AC 1.0/1.5/2.0 TR for fixing against defective parts of AC taking down under respective item complete all as specified and as directed.
Supply only new compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR split type AC, ISI marked for fixing against defective parts of AC taking down under respective item complete all as specified and as directed.
S&F fan motor of AC (Window/Split Type) 1.5 TR Capacity of approved Make and required size to suit existing AC including taking out the unserviceable fan motor from AC, complete all as specified and as directed.
All as per Item No. 8 above but AC (Window/Split Type) 2.0 TR Capacity, complete all as specified and as directed.
S&F air circular blower fan motor of AC (Split Type) 1.5 TR Capacity (as per sample/site Requirement) including taking out unserviceable air circular blower fan motor from AC, complete all as specified and as directed.
S&F air circular blower fan motor of AC (Split Type) 2.0 TR Capacity (as per sample/site requirement) including taking out unserviceable air circular blower fan motor from AC, complete all as specified and as directed.
S&F remote circuit board including senser and display with remote of AC (Split Type) 1.5 TR Capacity (as per sample/ site requirement) including taking out unserviceable remote circuit board including senser and display from AC, complete all as specified and as directed.
S&F remote circuit board including senser and display with remote of AC (Split Type) 2.0 TR capacity (as per sample/ site requirement) including taking out unserviceable remote circuit board including senser and display from AC, complete all as specified and as directed.
S & F for PCB for control unit for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity as per existing and same make ISI marked including taking down unserviceable old ones complete all as specified and as directed.
S&F capacitor running 36 mfd – 45 mfd of AC (Window/Split Type) 1.5/2.0 TR capacity including taking out unserviceable capacitor from AC, complete all as specified and as directed.
S&F capacitor starting 80 mfd – 120 mfd of AC (Window/Split Type) 1.5/2.0 TR capacity including taking out unserviceable capacitor from AC, complete all as specified and as directed.
S&F fan motor capacitor 4 mfd of AC (Window/ Split Type) 1.5/2.0 TR capacity including taking out unserviceable fan motor capacitor from AC, complete all as specified and as directed.
S&F starting relay of AC (Window/Split Type) 1.5/2.0 TR capacity including taking out unserviceable starting relay from AC, complete all as specified and as directed.
S & F for overload protection coil 230V, AC for window type AC 1.0 ton/1.5 Ton/2.0 ton capacity ISI marked including taking down unserviceable old ones complete all as specified and as directed.
Taking out existing unserviceable potential relay and supply and fix potential relay for for window type AC 1.0 Ton/1.5 Ton/2.0 ton capacity ISI marked complete all as specified and as directed.
S&F for runner made of aluminium suitable for window type AC of 1.0 Ton/1.5 ton/2.0 ton capacity including taking out old unserviceable runner complete all as specified and as directed.
S & F for operation knob for window type AC 1.0 ton/1.5 ton/2.0 ton capacity including taking out old unserviceable knob ISI marked complete all as specified and as directed.
S & F for PVC air filter for window type AC 1.0 ton/1.5 ton/2.0 ton capacity including taking out old unserviceable air filter ISI marked complete all as specified and as directed.
S & F for front grill for window type AC 1.0 ton/1.5 ton/2.0 ton capacity including taking out old unserviceable front grill complete all as specified and as directed.
S&F thermostat switch of AC (Window/Split Type) 1.5/2.0 TR Capacity including taking out unserviceable thermostat switch from AC, complete all as specified and as directed.
S & F for overload protection coil 230 V AC for split type AC 1.0 ton/1.5 ton/2.0 ton capacity including taking out old unserviceable overload protection coil ISI marked complete all as specified and as directed.
S & F for LCD/LED display unit for split type AC 1.0 ton/1.5 ton/2.0 ton capacity including taking out old unserviceable unit ISI marked complete all as specified and as directed.
S & F for 15/20 mm bore PVC flexible conduit including taking out old unserviceable PVC flexible conduit ISI marked complete all as specified and as directed.
S & F for PVC air filter for AC split type 1.5/2.0 ton capacity including taking out old unserviceable air filter ISI marked complete all as specified and as directed.
M & L for replacement of unserviceable bearing/bush for blower and fan motor of capacity 1.0/1.5/2.0 TR complete all as specified and directed.
Supply and filling Gas Charging with R-22 /R134a/R404 Gas of AC (Window/Spilt Type) 1.5/2.0 TR capacity with required quantity of refrigerant in the unit including checking of leakage in the system, brazing the leakage parts of oil gas tubing as required, complete all as specified and as directed.
Re-installation and re-commissioning air conditioner (1.5TR, 2.0TR) split type/window type AC (1.5/2.0) TR electric driven (single phase) comprising for split type AC one inner unit, one outer unit with servicing and installed at site including making connection with copper tubes from inner unit to outer unit including filling of refrigerant gas as required and electrically connecting up and testing, complete all as specified and as directed.
S&F for mild steel stand as per existing for AC Window type/Split type 1.5 to 2.0 TR capacity, grouting with brick wall with mild steel expandable bolts with steel rawl plug including making good walls in cement mortar (1:3) as required including dismantling old unserviceable mild steel stand for AC’s complete all as specified and as directed.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old unserviceable ones, complete all as specified and as directed.
S&F in repairs MCB SPN 240 volts 40 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and as directed.
S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and as directed.
Supply and fixing in repairs of copper capillary tube 5/8" as suitable size for repairing window/split type AC complete all as specified and as directed.
Supply and fixing in repairs of copper capillary tube 1/2" as suitable size for repairing window/split type AC complete all as specified and as directed.
Supply and fixing inrepairs of copper capillary tube 1/4" as suitable size for repairing window/split type AC complete all as specified and as directed.
All as per item No. 40 above but capacity 300/315 ltr, complete all as specified and as directed.
S&F for ice cooling chamber (as Approved) for refrigerator 190/260/300/315 LITRE capacity including taking down unserviceable Ice cooling chamber from refrigerator, complete all as specified and as directed.
S&F for starting relay (OPEN TYPE/BOX TYPE) for refrigerator of any description including taking down unserviceable starting relay from refrigerator, complete all as specified and as directed.
M&L for preparing external old steel surfaces of refrigerator 190/260/300/315 LITRE capacity, removing existing paint and applying one coat synthetic enamel paint (as approved colour shade) with spray painting and writing MES No. etc., complete all as specified and as directed.
Supply only chiller tray for refrigerator for 300 ltrs capacity, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
Supply only chiller tray for refrigerator for 190 litrs capacity, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
Supply only vegitable tray for refrigerators 260 ltr capacity, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
Supply only vegitable tray for refrigerators 315/300litre capacity, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
Supply of door hinges suitable for referigerator 300/ 190 litre capacity, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
Supply only PVC refrigerator stand suitable for 300/315 litre refrigerator, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
Supply only PVC refrigerator stand suitable for 190 litre refrigerator, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
S&F in replacement of capillary tube and stainer for any type and capacity of domestic refrigerator ISI marked complete all as specified and as directed.
Supply only cooling coil unit for domestic refrigerator, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed.
S & F in repairs timer/bimetalic relay of existing type for domestic refrigerator ISI marked complete all as specified and as directed.
S & F in repairs relay for domestic refrigerator of any type, complete all as specified and as directed.
S & F for thermostat suitable for domestic refrigerator of any type including taking out old unserviceable thermostat ISI marked complete all as specified and as directed.
S&F in repairs door rubber inner liner suitable for refrigerator capacity 315/300 ltrs, complete all as specified and as directed.
S&F in repairs door rubber inner liner (magnetic) suitable for water cooler capacity 40 ltrs, complete all as specified and as directed.
S&F in repairs door rubber inner (Magnetic) suitable for water cooler capacity 60 ltrs, complete all as specified and as directed.
S&F in repairs door rubber inner liner ( magnetic) suitable water cooler capacity 80/ 120 ltrs, complete all as specified and as directed.
S&F in repairs bib tap cast copper alloy 15mm push type chromium plated, complete all as specified and as directed.
S&F in repairs PVC connection 600mm long with brass unions at both ends with brass nuts, suitable for fixing to 15mm dia GI Pipe, complete all as specified and as directed.
S&F in repairs 15mm PVC float valve with epoxy coated aluminium arm, with PVC polythene ball suitable for water coolers, complete all as specified and as directed.
S&F in repairs PVC polythene ball suiatble to fix to 15mm PVC float valve, complete all as specified and as directed.
S&F in repairs PVC drain out pipe 25 mm dia bore as per existing by providing necessary GI Clamps nuts bolts etc. complete all as specified and as directed.
S&F for replacement of base plate of water cooler of any cacapcity, made out of 2mm thick MS sheet and painting with two coats of enamel paint over one coat of re oxide primer including preparation of surfaces, complete all as specified and as directed.
All as per Item No. 67 above but for water wooler 120/150 LITRE Capacity, complete all as specified and as directed.
M&L preparing external old steel surfaces of water cooler 40/80 LITRE capacity, removing existing paint and applying one coat cynthetic enamel paint (as approved colour shade) with spray painting including preparation of surfaces and writing MES No, etc., complete all as specified and as directed.
All as per Item No. 69 above but Water Cooler 120/150 LITRE Capacity, complete all as specified and as directed.
Supply only new compressor sealed unit of suitable capacity/ model in the unit properly for storage type water cooler of any capacity ISI marked for fixing against defective parts of water cooler taking down under respective item complete all as specified and as directed.
M&L rewinding fan motor of existing water cooler 40/80 and 120/150 LITRE capacity with suitable size copper wire including taking out unserviceable rewinding from fan motor of AC, complete all as specified and as directed.
M & L for replacement of capillary tube and stainer for storage type water cooler of any capacity ISI marked complete all as specified and as directed.
S & F for overload protection coil 230 V for storage type water cooler of any capacity including taking out old unserviceable overload protection coil ISI marked complete all as specified and as directed.
S & F for relay suitable for water cooler of any capacity including taking out old unserviceable relay ISI marked complete all as specified and as directed.
S & F for thermostat suitable for water cooler of any capacity including taking out old unserviceable thermostat ISI marked complete all as specified and as directed.
S & F for running capacitor suitable for water cooler of capacity 80/150 ltrs including taking out old unserviceable running capacitor ISI marked complete all as specified and as directed.
S & F for starting capacitor 80/100 MFD 230 volts AC for water cooler of capacity 40/80/120/150 ltrs including taking out old unserviceable starting capacitor ISI marked complete all as specified and as directed.
S&F for starting relay for water cooler 40/80/120/150 LITRE capacity including taking down/out unserviceable starting relay from water cooler, complete all as specified and as directed.
Repair / maintenance and overhauling to servo voltage stabilizer of capacity 1 KVA to 5 KVA from position, open the outer covers, overhauling the complete unit by cleaning with suitable cleaning materials and replacement of minor spares such as fuse, diodea, carbon brushes & holders, internal electric wiring and electronic accessories and insulate properly by varnshing, greasing, CRC spraying complete all as specified and directed. Note: Spares such ac voltmeter, ammeter, MCB, toggle switch, PCB board and relays measured and paid separately under respective items and labour cost deemed to include in quoted rates for replacement of spares. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit.
M&L for removing the unserviceable voltage stabilizer of capacity 1 to 5 KVA from position, open the outer covers, remove the burnt out winding from the dry transformer/servo motor/ rotor winding and rewinding with super enameled copper winding wire, insulate properly by varnishing,greasing,CRC spraying, setting/ testingof buck/boost relay, replacement of U/s minor electrinic parts, assemble back & fixing in its original position including testing for proper functioning, complete all as specified and directed.
Supply only over load /volt relay, for fixing against defective parts of voltage stabilizer taking down under respective item complete all as specified and as directed.
Supply only under load/volt relay, for fixing against defective parts of voltage stabilizer taking down under respective item complete all as specified and as directed.
Supply only PCB control for 1 KVA to 5 KVA (single phase), for fixing against defective parts of voltage stabilizer taking down under respective item complete all as specified and as directed.
Supply only integrated circuit IC-2250, for fixing against defective parts of voltage stabilizer taking down under respective item complete all as specified and as directed.
Supply only integrated circuit IC-1950, for fixing against defective parts of voltage stabilizer taking down under respective item complete all as specified and as directed.
Supply and fixing in repairs of voltage stabilizer for automatic operation, single phase, naturally air cooled designed for input voltage variation between 130Volt to 250 Volt with out put voltage stabilizer at 230 Volt with accuracy of (+-) 2.5%, capacity 5 KVA complete all as specified and as directed.
M&L for Servicing of Aqua Guard, RO any type/make including replacement of micron cartridge, ultra filter, pre- filter, RO membrane with cleaning of inlet outlet pipe upto water cooler including repair of raw water feed pump and repair of internal wiring refixing in same location and re-writing of MES No complete all as specified and as directed.
S&F cable PVC insulated flexible type 2.5 sqmm 4 core copper conductor cable including taking out old and unserviceable cable, complete all as specified and as directed.
Taking down old unserviceable sub main wiring of any size and any description complete all as specified and as directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn through and including PVC casing capping of suitable size wirh ISI marked medium grade including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to main switches /DB's or common earth duly and including making good the disturbed surface as per existing matching, complete all as specified and as directed. Notes:- (i) Three run of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit length.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLS cable (with colour code), drawn through and including PVC casing capping of suitable size wirh ISI marked medium grade including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to main switches /DB's or common earth duly and including making good the disturbed surface as per existing matching, complete all as specified and as directed. Notes:- (i) Three run of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit length. (ii) The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.
M/S RAM DAS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .