Loading…
Loading…
Tender Value
₹98.9 L
EMD Value
₹2.0 L
Closing Date
4 May 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT.G
17 conditions · 5 needing a document upload
Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE- I/CT/GCC2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
34 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
This tender shall also complies with "Indian Railways Standard General Conditions of Contract, April 2022 (Advance Correction Slip No. 11)" vide Railway Board letter No. 2022/CE-I/CT/GCC- 2022/POLICY/Pt.I (E-3320424), dated: 13.03.2026 (attached)
Electrical work in connection with (i) Improvement/Upgradation of NRSA section in Annex-II & 4th floor corridor in Annex-I building at Baroda House. ii) Improvement of room nos. 439 & 440 A of the Engineering Branch at Annexe-I at Baroda House. iii) Repair/Renovation of training Centre for Personal Branch at Baroda House.
04-SRDEE-G-DLI-2026-27
04-SRDEE-G-DLI-2026-27
Open
Works - General
9 Months
Delhi, Delhi
₹0
₹2.0 L
4 May 2026
10 Apr 2026
20 Apr 2026
129 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 98,89,037.6 | ||
| — | 1030.00 | — | — | ||
| Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and conforming to IS 732:2024 or latest & as per explanatory note. Group C | — | — | — | 14,89,349.1 | |
| — | 4800.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning & as per explanatory note. 1x2.5 sq.mm | — | — | — | 1,92,000 | |
| — | 1800.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning & as per explanatory note. 1x4.0 sq.mm | — | — | — | 95,400 | |
| — | 600.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning & as per explanatory note. 1x10.0 sq.mm | — | — | — | 81,000 | |
| — | 2000.00 | — | — | ||
| Supply and recessing/fixing of PVC conduit pipe of 25mm size conforming to IS 9537 Part-III: 1987 (or Latest version) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per site requirement conforming to IS 9537 (Part 3) latest. | — | — | — | 62,000 | |
| — | 2000.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire | — | — | — | 5,50,000 | |
| — | 1000.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire | — | — | — | 3,34,000 | |
| — | 600.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. 2 x 6 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 2,63,400 | |
| — | 600.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. 2 x 10 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 3,42,000 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854 latest version & as per explanatory note. Size= 3 Module | — | — | — | 3,250 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854 latest version & as per explanatory note. Size= 6 Module | — | — | — | 10,000 | |
| — | 300.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to IS 3854 latest version & as per explanatory note. Size= 8 Module | — | — | — | 37,500 | |
| — | 550.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required conforming to IS 3854 2023 or latest and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory note. 6 Amp Switch | — | — | — | 29,397.5 | |
| — | 200.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required conforming to IS 3854 2023 or latest and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory note. 16 Amp Switch | — | — | — | 17,800 | |
| — | 200.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required conforming to IS 3854 2023 or latest and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory note. 5/15A multi pin socket | — | — | — | 26,200 | |
| — | 500.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required conforming to IS 3854 2023 or latest and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory note. 13A universal socket | — | — | — | 49,500 | |
| — | 450.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required conforming to IS 3854 2023 or latest and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per explanatory note. 3 pin 5/6 A Socket outlet | — | — | — | 45,000 | |
| — | 160.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required and conforming to IS 3854:2023 or latest & CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. | — | — | — | 71,040 | |
| — | 130.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required and conforming to IS 3854:2023 or latest & CPWD General Specifications for Electrical Works Part-I Internal - 2023 & as per explanatory note. | — | — | — | 72,410 | |
| — | 30.00 | — | — | ||
| Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required confirming to CPWD DSR (E&M) 2022 & as per explanatory note. | — | — | — | 21,810 | |
| — | 80.00 | — | — | ||
| Provision of energy efficient 230V, 50Hz a.c ceiling fan with BLDC motor of size 1400mm sweep having wattage of 35W, 5 star, speed regulator operation: Using Remote Control, 36 months warranty complete as per IS :374:2019 or latest, IE rules & site requirement. It shall also include the scope of supply and installation of safety cord of SS as per IS:302 Part 2 Sec-80. Dia & length of such cord shall be as per recommendation of OEM of fan and same shall be approved by railways & as per explanatory note. | — | — | — | 2,92,000 | |
| — | 40.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current ( BLDC) motor, class of insulation B, 03 Nos blades, 30 CM long down rod, 02 Nos conopies, shakle kit, safety rope, copper winding, Power factor not less than 0.9, service value ( CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350RPM ( tolerance as per IS: 374-2019 or latest) THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C ( max) , insulation resistance more than 2 mega ohm, suitable for 230 V, 50Hz, single phase AC supply, earthing etc. complete as required. CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. | — | — | — | 1,09,200 | |
| — | 90.00 | — | — | ||
| Supply, fixing, testing and commissioning of 400mm sweep wall mounted fan complete conforming to latest IS/IEC specification & as per explanatory note. | — | — | — | 1,95,750 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 1x18 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,28,600 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 2x18 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 2,17,600 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15-18 Watt complete with all mounting arrangement, accessories complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec II attached or latest & as per explanatory note. | — | — | — | 74,400 | |
| — | 120.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED deep recessed down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15-20 Watt complete with all mounting arrangement, accessories complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec II attached or latest & as per explanatory note. | — | — | — | 1,37,760 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaries 595x595 mm size, recessed mounting fitting (Tile type), as per IS : 10322 or latest having system wattage less than or equal to 45-50 Watt, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement with suitable frame to avoid droping down of fitting of make Phillips, Bajaj, Havells or similar confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev'4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,61,500 | |
| — | 200.00 | — | — | ||
| Supply of LED light luminaries 300x300mm size (1x1), having system wattage less than or equal to 15W (approx.), CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible complete confirming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 2,47,200 | |
| — | 130.00 | — | — | ||
| Design, Supply, Fixing, testing and commissioning of Recessed luminaire with LED (Light Emitting Diode) system power: 32 W, Luminous flux of luminaire 3840 lm, 120 Lm/w, Colour temperature 3000 K/4000 K/5700 K/ 6500 K (As per ANSI Bin), CRI > 80, R9>20, THD<10%, P.F>0.95, Driver Efficiency>85%, SDCM<3, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, 1.4 mm thick extruded aluminium profile with Polyester powder white colored coat applied over a 5- stage pre-treatment, Protruded Prismatic diffuser for glare-free uniform illumination, UGR<16, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class I, IP 40, L = 595 mm, B = 595 mm, H = 75 mm, A = 14 mm. & confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 5,59,000 | |
| — | 110.00 | — | — | ||
| Design, Supply, Fixing, testing and commissioning of LED recess mounted luminaire with LED (Light Emitting Diode) system power: 25W, Luminous flux of luminaire 3500 lm, 110 Lm/w, color temperature of 3000 K/4000 K/5700 K/ 6500 K (As per ANSI Bin), 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy efficient LEDs, CRI>80, R9>20, THD<10%, P.F>0.95, Driver Efficiency>85%, SDCM<3, electronic control gear, direct light emission, sheet metal CRCA housing, polyester white powder coat applied over a 5-stage pre-treatment, Prismatic diffuser for glare-free uniform light distribution, UGR<19, Protection class I, IP40, surge protection of 2.5kV, L = 1195mm, B = 295mm, H = 70mm & conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 5,01,600 | |
| — | 220.00 | — | — | ||
| Design, Supply, Fixing, testing and commissioning of Deep Recessed downlight luminaire Blaire with HPE (High-Performance Efficiency) LED (Light Emitting Diode) system power: 15 W, Luminous flux of luminaire 1650 lm, 110 Lm/w, Colour temperature of 3000 K/4000 K/5700 K/ 6500 K (As per ANSI Bin) CRI > 80, R9>20, THD<10%, P.F>0.95, Driver Efficiency>85%, SDCM<3, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, Luminaire housing in aluminium, Polyester powder white coloured coat applied over a 5- stage pre-treatment, Prismatic diffuser for homogenous light distribution, UGR<19, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, Electronic control gear, Protection class II, IP 20 Ø = 175 mm, DA(Ø) = 160 mm, H = 59 mm. & confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 4,07,000 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing & commissioning of inline fan size 10" dia complete conforming to latest relevant IS/IEC standards as per site requirement & as per explanatory note. | — | — | — | 1,63,050 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing & commissioning of inline fan size 8" dia complete conforming to latest relevant IS/IEC standards as per site requirement & as per explanatory note. | — | — | — | 90,380 | |
| — | 550.00 | — | — | ||
| Supply of PVC insulated flexible Copper cable 3C x 2.5 sq mm complete as per latest IS and IE rules & as per explanatory note. | — | — | — | 56,045 | |
| — | 20.00 | — | — | ||
| Supply, installation, testing & commissioning of uPVC pipe, complete with fittings, supports, U-trap arrangement, Clean Plug and accessories for AHU/IDU as per site requirement & as per explanatory note. 32 mm dia ( with 9 mm Nitrile) | — | — | — | 4,360 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing & commissioning of uPVC pipe, complete with fittings, supports, U trap arrangement, Clean Plug and accessories for AHU/IDU as per site requirement & as per explanatory note. 40 mm dia ( with 9 mm Nitrile) | — | — | — | 2,670 | |
| — | 15.00 | — | — | ||
| Supplying & fixing powder coated extruded aluminium supply Air grills with aluminium volume control dampers as per specification & as per explanatory note. | — | — | — | 1,36,575 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing & commissioning of supply air diffusers of powder coated aluminium volume control dampers with anti smog ring & removable core & as per explanatory note. | — | — | — | 60,920 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications & as per explanatory note. | — | — | — | 35,230 | |
| — | 450.00 | — | — | ||
| GSS Ducting: Supply, fixing, testing & commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gasket, elbows , splitter dampers, vanes , hangers, supports etc. as per approved drawings and specifications of the following sheet thickness complete as required & as per explanatory note. Thickness 0.80 mm sheet | — | — | — | 5,68,350 | |
| — | 3.00 | — | — | ||
| Supply, Installation, testing & commissioning of "Indoor VRV Units (Nominal Capacity) Ceiling Mounted Round/4way flow cassette type Unit" Design, Supply, Installation, testing & commissioning of ceiling mounted cassette type unit. These units shall be installed between the bottom of finished slab & top of false ceiling. The unit must have in built drain pump, suitable for vertical lift up to 750 mm. The noise level of unit at the highest operating level shall not exceed 50dB (A), at a vertical distance of 1.5 m from the grille of the unit. Unit shall have provision of connecting fresh air. The unit shall be supplied with pre-filters, fan section and DX coil section. The filter shall be easy to remove, clean & re install. The body shall be light in weight and shall be able to suspend from four corners. Unit shall have an external attractive panel for supply and return air. Each unit shall have high lift drain pump, and Low gas detection system. The fan shall be aerodynamically designed diffuser turbo fan type. All 4 louvers of the unit shall be independently adjustable for position as per user preference. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit can be integrated with other systems to stop automatically such as in case of fire 1and confirming to specification & as per explanatory note. 4.0 TR/ 1236 CFM | — | — | — | 1,83,513 | |
| — | 2.00 | — | — | ||
| Outdoor Unit: "Variable Refrigerant flow system" Supply, Installation, testing and commissioning of modular type variable refrigerant flow air conditioning system suitable for both heating and cooling with Inverter Scroll Compressor suitable for 415 ±10% V for outdoor unit including fully charged with refrigerant R410A suitable to operate at -5° to 52 C ambient temperature to outdoor unit and all running refrigerant pipe. It shall include anti vibration isolator pad for outdoors unit. The unit shall be complete in all respect as per site requirement. The unit shall have auto phase corrector so that unit can work in case of phase reversal and accumulator should be present in outdoor units to prevent liquid backflow in compressor & as per explanatory note. 16HP VRF OUTDOOR UNIT (Cooling & Heating) | — | — | — | 7,07,214 | |
| — | 3.00 | — | — | ||
| Supply, installation & testing of cordless remote with receiver for the above indoor & cassette type units and confirming to specifications of Air conditioning system in this work and site requirement & as per explanatory note. | — | — | — | 3,858 | |
| — | 25.00 | — | — | ||
| "Refrigerant Piping for VRF system": Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification of IS/IEI & as per explanatory note. 28.6 mm dia with 19mm thick nitrile rubber insulation : 16G | — | — | — | 60,600 | |
| — | 40.00 | — | — | ||
| "Refrigerant Piping for VRF system": Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification of IS/IEI & as per explanatory note. 22.2 mm dia with 19mm thick nitrile rubber insulation : 16G | — | — | — | 75,680 | |
| — | 10.00 | — | — | ||
| "Refrigerant Piping for VRF system": Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification of IS/IEI & as per explanatory note. 19.1 mm dia with 19mm thick nitrile rubber insulation : 18G | — | — | — | 12,530 | |
| — | 50.00 | — | — | ||
| "Refrigerant Piping for VRF system": Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification of IS/IEI & as per explanatory note. 15.9 mm dia with 19mm thick nitrile rubber insulation : 18G | — | — | — | 53,150 | |
| — | 50.00 | — | — | ||
| "Refrigerant Piping for VRF system": Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification of IS/IEI & as per explanatory note. 12.7 mm dia with 19mm thick nitrile rubber insulation : 18G | — | — | — | 42,350 | |
| — | 20.00 | — | — | ||
| "Refrigerant Piping for VRF system": Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification of IS/IEI & as per explanatory note. 9.5 mm dia with 19mm thick nitrile rubber insulation : 18G | — | — | — | 13,120 | |
| — | 20.00 | — | — | ||
| "Refrigerant Piping for VRF system": Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor &outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification of IS/IEI & as per explanatory note. 6.4 mm dia with 19mm thick nitrile rubber insulation : 18G | — | — | — | 9,240 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing & commissioning of UPVC drain pipe size 25 mm dia complete with all accessories conforming to latest relevant IS/IEC standards & as per explanatory note. | — | — | — | 15,600 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing & commissioning of T- Joints and headers etc. complete & as per explanatory note. | — | — | — | 7,167 | |
| — | 400.00 | — | — | ||
| Supply, laying, testing and commissioning of communication cable (1.5 Sq. mm x 2 core) complete & as per explanatory note. | — | — | — | 73,200 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of suitable size interconnecting control cable size ( 5Cx6.0 sq. mm) from indoor to outdoor unit complete with suitable size copper earthing as per latest relevant IS & IE rules and site requirement & as per explanatory note. | — | — | — | 35,900 | |
| — | 100.00 | — | — | ||
| Supply of Refrigerant (R410a/32) charge to the outdoor unit and connected pipes between outdoor unit as per site requirement complete & as per explanatory note. | — | — | — | 1,01,300 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of necessary fittings, Y-joints/ Refnet joints. Y-joint/ T-joint/ Refnet separation refrigeration pipe joints and headers shall be in the appropriate orientation to enable correct distribution of refrigerant. The distribution joints should be factory insulated with close cell nitrile rubber tubular sections of class 'O' fire rating as per IS: 476. Minimal brazing shall be done and shall be limited only to outside area i.e. non air-conditioned area. Further distribution shall be with PPM/header kits and using fire/ brazing free connection joints as required and confirming to specifications & as per explanatory note. | — | — | — | 21,168 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted high ductable type indoor unit equipped with washable systhetic media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V +- 10%, 50 Hz complete as required. The indoor unit must shut down upon receiving a signal from the BMS system / Fire Signals. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor) High Static Ductable units (minimum 78 Pascal external static pressure) of capacity 8.0 TR & as per explanatory note. | — | — | — | 85,191 | |
| — | 1.00 | — | — | ||
| Supply, Installation, testing and commissioning of MS fabricated outdoor unit stand for placing outdoor unit of VRV system. The stand shall be manufactured from MS C Channel of minimum 3-4 mm thick. It shall be finished with enamel paint as per client/architect approval & as per explanatory note. | — | — | — | 3,506 | |
| — | 500.00 | — | — | ||
| Fabrication of MS stand/cabinets or any other MS structure of approved drawing for precooling points/battery charger/ covering of electrical structure. The work includes cutting, welding , riveting, nut bolts of the MS structure including applying a primary coat of steel primer and one coat of paint of approved shade & as per explanatory note. | — | — | — | 58,500 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing & commissioning of Pop up Box of conference hall table including installation kit 2 switch 6 A and 2 socket 6 A and 1 RJ 11 and 1 RJ 45 as per site requirement conforming to latest IS & IEC rules & as per explanatory note. | — | — | — | 23,000 | |
| — | 10.00 | — | — | ||
| Provision of 190 Liter 5 star frost free single door 190 liters Refrigerator conforming to IS 17550 or latest & as per explanatory note. | — | — | — | 1,60,570 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of 150 liter/Hrs L water cooler. Storage type self contained drinking water cooler, operation on 230V AC 50 Hz (Non CFC refrigerant), cooling cap. (in L/hr )-150, storage Cap. (in Lts) 150, Max Energy Consumption -1550 W, Power Factor = or more than 0.85, Tank sheet material-Stainless steel (Grade A-IS304), Thickness of sheet (in mm) 0.8. equal to or more than, Water Tank cover material -Stainless steel (Grade A IS304) thickness 0.8 and lid bottomsheet material and thickness-Alluminium sheet material & thickness-Aluminium sheet 1.5 (in mm ), operating voltage 230 V ac single phase 50 Hz, Confirming to IS -1475 or latest, ISI marked, warranty on site as per IRS terms & conditions or OEM whichever is maximum, warranty on compressor as per IRS terms & Condition or OEM whichever is higher & as per explanatory note. Make USHA, VOLTAS, SIDWAL, BLUE STAR or similar. | — | — | — | 1,09,452 | |
| — | 1.00 | — | — | ||
| Supply of data management system consisting of computer of Dell Inspiron 24 All-in- One or similar having 13th Gen Intel@ Core I5-1335U processor windows 11 OS , Intel UHD graphics, 8GB DDR4 3200 MT/s memory, 512 GB M.2,PCle , NVMe, SSD storage, 23.8" or bigger Non tuch Anti glare FHD display, FHD RGB+IR camera, preinstalled MS Office 2021 or latest, latest Wireless and bluetooth connectivity, black colour along with wireless keyboard and mouse complete with 3-in-1 multi function laser printer with automatic 2 sided printing and wireless networking similar to Brother Make -Model : DCP-B7535 DW or equivalent & as per explanatory note. | — | — | — | 90,982 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ExplanatoryNote-04-BH.pdf
ATTACHMENT
SpecialCondition-04.pdf
ATTACHMENT
TenderDocument-04.pdf
ATTACHMENT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf GCC ACS No 11
ATTACHMENT
TECHSPEC-I.pdf
ATTACHMENT
TECHSPEC-II.pdf
ATTACHMENT
TECHSPEC-IIIAC.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
NewSpecialConditions-04-BH.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .