Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC Quoted lowest bid | |
| 2 | Not Admitted-Finance | - | Not Admitted-Finance Not qualified for AOC | |
| 3 | Not Admitted-Finance 0 BHOLA BABU H B ROAD BHARALUMUKH MACHKOWA GUWAHATI KAMRUP ASSAM 781009 | KAMRUP METRO | ASSAM | 781009 | - | Not Admitted-Finance Not qualified for AOC | |
| 4 | Not Admitted-Finance 5 9 35 HAZARHAT KALITALALANE HOWRAH 711104 | HOWRAH | HOWRAH | WEST BENGAL | 711104 | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
Refer Docs
EMD Value
₹72,604
Closing Date
8 Jul 2020, 3:30 pmClosed
CEO HDA
Chief Executive Officer Haldia Development Authority City Centre P.O. Debhog Haldia Purba Medinipur Pin 721657
Supply Installation Testing and Commissioning of LED Street Light from Ramchandrapur Bus stand to Rustam Ali Shah Urush Ghar Ramchandrapur Idga and two Minimast with LED Flood lighting arrangement at the premises of Rustam Ali Shah Urush Ghar Ramch
2020_HDA_286609_1
33/HDA/ECELECT/20192020 (2ND Call)
Open Tender
ELECTRICAL WORKS M/R
Item Rate
90 days
Haldia
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹72,604
Haldia
24 Aug 2020
22 Jun 2020
10 Jul 2020
23 Jun 2020
8 Jul 2020
2 Jul 2020
29 Jun 2020
Items
Supply & delivery of LED Street light of following specification: a) 90 W (+/-5%) for each set. b) Lumen output should be minimum 9000 lumen from each set. c) The luminaries should be of IP 66 protection. d) Input Voltage of 130 V – 270 Volt, 50 Hz. A.C. supply e) Driver should have in-built protection against high voltage surge, open circuit & short circuit. f) Housing should be of Die-cast aluminium housing with epoxy powder coating and having cooling fins for effective heat dissipation. Separate cavity for driver & LED lamp. g) Operating Temperature: 50 Degree centigrade. h) Third party test report from NABL accredited laboratory of LM-79, LM-80 & IP-66. i) The product should have 5 years warranty period. (Make: PHILIPS LIGHTING INDIA LTD./HAVELLS INDIA LTD./BAJAJ ELECTRICALS LTD)
Supply & delivery of LED Flood Light of following specification: a) 150 W (+/-5%) for each set. b) Lumen output should be minimum15000 lumen from each set. c) The luminaries should be of IP 66 protection. d) In put Voltage of 130 V – 270 Volt, 50 Hz. A.C. supply e) Driver should have in-built protection against high voltage surge, open circuit & short circuit. f) Housing should be of Die-cast aluminium housing with epoxy powder coating and having cooling fins for effective heat dissipation. Separate cavity for driver & LED lamp. g) Operating Temperature: 50 Degree centigrade. h) Third party test report from NABL accredited laboratory of LM-79, LM-80 & IP-66. i) The product should have 5 years warranty period.(Make: PHILIPS LIGHTING INDIA LTD./HAVELLS INDIA LTD./BAJAJ ELECTRICALS LTD)
Supply & delivery of Hot Dipped Galvanized Iron Sheet (G.I. sheet thickness- 3.0 mm) Street Light Pole 9 Mtr. Long Swaged type with single swan neck to be extended up to 1.5 Mtr. at the top part of the pole. This specification covers the design, manufacture, testing at works of 9 mtr long (swaged type) Hot dip GI Steel tubular Pole conforming to IS: 2713 (P‐I &II)/1980 (Confirming to 410-SP-26) with GI base plate and Single Swan neck arm Bracket and latest amendment if any. (Refer to the Specification and Drawing in Annexure-II and follow Rate submission form-IV). The rate should include testing at your works, all taxes and delivery the materials at different locations of HDA planning area, BIS license & Type test report must be submit. (Make:UTKARSH INDIA LTD/ELECTRO POLE PRODUCTS PVT. LTD/TRANSRAIL LIGHTING LIMITED/BAJAJ ELECTRICALS LTD/SUBHAM POLE PRODUCTS PVT. LTD).
Supply, delivery & installation of 12 M Height Hot Dipped Galvanized (BS EN ISO: 1461 2009) coated, hot rolled Sheet of non-structural alloy 3.0 mm thick (BSEN 10025) Octagonal/polygonal Mini-mast (single section) with monkey climbing arrangement and 1 no Full Moon Bracket suitable to mount 4 nos. of LED flood light fittings (with luminaries mounting plate and provision of passing wire) along with G I nut bolts, (IS 1367) in house Terminal arrangement with cover for cable loop-in and loop-out. (Refer to the Specification and Drawing in Annexure-III and follow Rate submission form- V). The rate should include testing at your works, all taxes and delivery the materials at different locations of HDA planning area.
Supply and fixing of SPMCB "B" Curve 1 Amp with ISI marked to be placed on a din channel of Pole and supply and fixing of Terminal connector at the suitable location of the pole.
Supply and fixing of Pole numbering Sticker (5" X 3") at the street light pole.)
Lifting of the running Under Ground Cable coming to the looping cable Box upto the top of the muffing above the top of the ground level by drawing through 40 mm dia rigid pvc pipe of superior Quality and tiding the same by no 10 SWG G I wire wiyh the pole including supply of pipe & wire & filling the top of the pipe/pipe hole with bitumen and neat cementing properly (average run- 1.5 mtrs/run X 2 runs per pole).
Supply and delivery of 1.1 KV grade 4 C X 16 Sq mm XLPE insulated and PVC sheathed aluminum armored Cable. As per IS 7098 Part -1 with latest amendment if any. The cable should have ISI mark.
Supply and Installation of HDA printed logo suitable 15"×9" on GI Octagonal/tubular Pole , on brick foundation of meter box, feeder pillar box .(3 nos logo p/pole,per meter box,per feeder pillar box.)
Laying of Cable by Jack push method through micro tunneling 2-3M deep under black top surface with excavation of double earth pit 1400×600×3000 mm on hard soil, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc (Excluding the supply of GI Pipe)
Supply and Installation of 10 KVA 3-phase CCMS (Centralised Control and Monitoring Sysytem) Inclusive of transportation, loading/ unloading, P&F, Transit Insurance, Handling, etc., with Micro process based controlled system with necessary MCB's, MCCB, timer, connectors and provision for energy meter etc., complete for finished item of work.
Supply, delivery, installation, testing & commissioning of single phase Feeder pillar box of size 1000 X 1000 X 400 mm made of 4 mm thick CRCA steel sheet with zinc powder coated outdoor type with top canopy, sides having lovers for ventilation, double door, complete with cu bus-bar, provision for installation of single phase meter at right side of the feeder pillar with individual locking arrangement as per direction of engineer-in-charge. (Consisting of following items in the feeder pillar) i) 40 Amp , 230 Volt Double Pole MCB 10 ka Breaking capacity -1 noii) TP 240 Volt 40 Amp air break AC Coil contactor -1 noiii) Mechanical Time Switch of daily dial with battery backup -1 noiv) 16 Amp. SPMCB "B" Curve of 10 KA Breaking Capacity -4 no.v) Indicating LED Lamp (Gen Next LED Indicator 22.5 mm ) -2 Novi) Cubical Ilu Lamp & Switch - 1 No.vii) 1Ph Voltmeter Cl 0.5 of 50-550 VAC (P-P) viii) Toggle switch - 1Noix) Power Connector 4 Way 32 Amp -3 Set x) 1Ph Ammeter Cl 0.5 with C.T xi) Copper Wire for internal wiring Installation of the feeder to be done by the earth cutting, brick soiling and cc foundation as required & sand filling, ramming and muffing around the feeder pillar box by brick and cement mortar work as per the direction of the Engineer-in-charge.
Supply & delivery of GI earth Spike (1830 X 20 mm)(Each Pole).
Earthing complete with driving of Earth Spike & connection of earth electrode with noncurrent carrying metallic parts of supports, stay.
Connecting the equipments to earth bus bar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (ii) No. 6 SWG
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc( 0.35 sqm per pole x 46).
Painting the vertical end faces of posts, wheel guards or railing or parapet with alternate bands of different colours as directed by the Engineer-in-charge with approved synthetic enamel paint (0.35 sqm per pole x46). (b)Two coats.
Laying of one No. cable up to 35 Sq mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Supply of High Density Poly-ethylene Pipe conforming to IS - 4984 - 1985 (Dia) [PE - 63] A. 6 Kg / Sq.Cm. (Working Pressure) (Dia) 50 mm.
Laying only Cable up to 50 sq.mm through existing RCC/Hume/ GI /HDPE Pipe/open masonry trench for single, 2, 3, 3½ & 4 core
Fixing only Flood light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
Fixing only street light Fitting with suitable tie clamps and MS platefor mounting on Pole/Tower or similar structure.
Labour for fitting and fixing high density poly-ethylene pipes or P.V.C pipes for below ground work including cost of jointing materials paints etc fitting and fixing all necessary specials, cutting pipes, making threads, cutting holes in walls or R.C.floor where necessary and mending good all damages excluding the coast of masonary or concrete work,if necessary,but including the cost and fitting and fixing holder bat clamps(any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the site engineer-in-charge.(Payment will be made on centre line measurement of the total pipeline including specials.)
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 16 (b) 250 x 250 x 100mm
Connection of luminaries with 3C X 1.5 Sqmm PVC insulated FR copper conductor through 9 mtr. Tubular Poles from looping box to light fittings as required.
Erection of single steel tubular pole of length upto 9 mtrs. With sole plate in C.C. (6:3:1) foundation 0.6x0.6x1.91 mtrs. as to G.S. having 600x600x150 mm thick C.C. (4:2:1) base block below sole plate with jhama metal incl. C.C. (6:3:1) muffing 0.3 mtr. dia & 0.3 mtr. above ground level including 3 mm thick neat cemented finish & providing GI earth bolt after making drilled holes etc. on the pole & carriage of pole upto 1.6 km from store depot. to work site including filling up the excavated earth pit with shifted soil & ramming properly.
Supply & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. 50 mm dia
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: i) 4 core X 16 sqmm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. i) 4 core X 16 sqmm
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts, For Soft Soil.
Excavation of soil for installation of Earth Electrode and filling & ramming. (a) For Soft Soil
Extra for providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
RCC cutting of 200mm depth, further soil cutting of depth 100mm for purpose of HDPE pipe laying under 1 Mtr. Length concrete
Preparation of RCC foundation of 550 mm dia and 2200 mm height (1200 mm below the ground level and 700 mm above the ground level) with required rod,cement chips and sand etc.at the ratio 1:1.5:3 with ground bolt 4nos for fixing the 12 Mtr Mini Mast(excluding supply of poles,nut-bolts and its erection) with a P.C.C base(300 mm) below RCC foundation.
Providing and fixing typical citizen information board constructed with BFS, PCC, 250 mm & 125 mm brick wall (1:4) with necessary 15 mm thick plastering (1:4) & rule pointing, including supply & fixing of white marble stone (1100mm X 800mm X 18mm) with black colour engraved lettering as per the enclosed drawing.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .