| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹17.5 L+₹22,045 (1.28%)Rejected-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-AOC L2 BIDDER |
Tender Value
₹19.7 L
EMD Value
₹39,600
Closing Date
29 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Amla
GE (AF) Amla, Amla Depot Distt Betul (MP) 460553
Repair/maintenance of water supply installation including cleaning of OH tank and UG sumps area at AFS Amla
2023_MES_587157_1
8531/E8 OF 2022-23
Open Tender
Civil Works
Item Rate
335 days
GE (AF) Amla
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹39,600
Yes
13 Jun 2023
27 Mar 2023
1 May 2023
27 Mar 2023
29 Apr 2023
10 Apr 2023
Amount
STP 360 KLD (Tondon Camp) Material and labour for cleaning of Balancing sewage tank for 360 KLD STP (tank size 6.0mx5.0 m x 2 m water depth) cleaning entire internal surface by removing dirt, sludge etc and throwing out to a distance not exceeding of 50 mtr from site with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water including using sludge cutter pump and suction pump of suitable capacity surface complete in all respects, using acid and other suitable methods, taking out air piping , descaling , clear holes and refixing the same all as specified and directed by Engineer-In-Charge. Note -Quoted rates shall also include for using fresh water for cleaning & sludge cutter pump and ladder for man entering into tank for removing of sludge from tank and de-watering will be the contractor scope under his own arrangement, use of suitable chemical for descaling and air /water piping complete .
STP 360 KLD (Tondon Camp) Material and labour for cleaning of Equalisation sewage tank for 360 KLD STP (tank size 5.0mx60 m x 3 m water depth) cleaning entire internal surface by removing dirt, sludge etc and throwing out to a distance not exceeding of 50 mtr from site with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water including using sludge cutter pump and suction pump of suitable capacity surface complete in all respects, using acid and other suitable methods, taking out air piping , descaling , clear holes and refixing the same all as specified and directed by Engineer-In-Charge. Note -Quoted rates shall also include for using fresh water for cleaning & sludge cutter pump and ladder for man entering into tank for removing of sludge from tank and de-watering will be the contractor scope under his own arrangement, use of suitable chemical for descaling and air /water piping complete .
Material and labour for taking out MBBR media from tank cleaned with suitable chemical for refilling after cleaning of MBBR tanks , M&L for cleaning of MBBR REACTOR TANK of size 2mx4m x5 m for360KLD STP by cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water. The cleaning of tank includes following . (a). Taking out MS/HDPE pipe with stainer, descaling the pipe and taking out stainer , cleaning of stainer / repair by suitable welding or replacement of stainless steel bars / sheet as required at site. (b). Descaling of air grid and cleaning of holes for air piping. (c). Descaling of interconnecting MS piping. (d). Applying all piping inside MBBR tanks and inner surface of Tanks with two coats of epoxy paint over coat of red oxide primer.
Material and labour for taking out Tube Settler media from tank cleaned with suitable chemical for refilling after cleaning, Material and labour for cleaning of TUBE SETTLER TANK of size 3.8.0m x 2.2 m x 2.7m for 360 KLD STP by cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water, Cleaning of chanels and applying the channels inside Tube setteler tank and inner surface walls of tanks with Two coats of Epoxy Paint over a coat of red oxide primer . Note -Quoted rates shall include for using fresh water for cleaning & sludge cutter pump for removing of sludge from tank and de-watering shall be the contractor's scope under his own arrangement.
Material and labour for cleaning of HYPO SOLUTION TANK/Chlorine contact tank for 360KLD , size of tank 3.8m x 1.8 m x1.3m by cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water all as specified and directed by Engineer-In-Charge . Note -Quoted rates shall include for using fresh water for cleaning & sludge cutter pump for removing of sludge from tank and de-watering shall be contractor's scope under his own arrangement.
Material and labour for cleaning of TREATED WATER TANK for 360 KLD , size of tank6.7m x3.8mx2m by cleaning entire internal surface by removing dirt, sludge etc with wire brush by applying bleaching powder and fresh water and clean entire surface repeatedly with fresh water and draining out soiled water including using pressure jet pump and suction pump capacity of pool surface complete in all , applying inner and outer walls of treated water tank with 2 coats of white wash complete all as specified and directed. Note -Quoted rates shall include for using fresh water for cleaning & sludge cutter pump for removing of sludge from tank and de-watering will be contractor scope under his own arrangement.
Painting work: Painting of the following Installed Machineries at 360KLD STP scrapping existing paint and spraying two coat of synthetic enamel paint over one coat of primer as per colour coading using Asian/Berjer paint manufacturer all as directed Pump Set with motor :- 06 Nos. Sand Filter :- 01 Nos. ACF-01Nos Air Blower with motor -02 Nos Sewage lifting pump :- 02 No. LT Panel/Control panel-01 nos MBBR-02 Nos, Tube Settler - 1 Nos All the suction/discharge pipe lines complete length for 360 kld stp
Supply only and make liquid form suitable for dosing machine and pore to dosing plant will be in Contractor scope as directed by Engr-In-charge of Trichloroisocyanuric Acid (90%) (C3CI3N303) Chlorine Granuals (90%) Size 5-8 Mesh Appearance : White Granuals Effective Chlorine : 90%,pH : 2.7 to 3.3 Note: Mixing & dosing will be in Contractor scope as directed BY Engr-In-charge
Supply only hypo solution (NAOCL) in HDPE container of capacity 50 Kg complete all as specified and directed.
M & L for replacement of tube duck media for tube settler tank for 360 KLD complete all as specified and directed.
Air Blowers For STPS M&L for opening air blower set twin lobe type of capacity 250 m3/hr make Everest or equivalent with blower & motor 12.5H P coupling after isolating the electric and air pipe connections opening the air compressor set for repair/overhauling including necessary lathe work if necessary & servicing of compressor, re-assemblying the compressor, greasing connecting, testing including proper alignment and commissioning complete all as specified at 360 KLD STP at AFAmlacomplete all as specified and directed.
Taking out unserviceable butterfly valve of size 100 mm bore and supply and fix new butter fly valve wafer type in CI Body with integrally moulded liner of nitrile or EPDM stainless steel Disc & stem, Liver operated as per IS 13095 in PN 1.0 in including jointing material such as rubber gasket, bolts, nuts etc direct integrally all as specified and as directed by Eng-in-Charge Make: Kirloskar/ISI MARK or kARTAR ,
Taking out unserviceable butter fly valve of size 80 mm bore and supply and fix new butter fly valve wafer type in CI Body with integrally moulded liner of nitrile or EPDM stainless steel Disc & stem, Liver operated as per IS 13095 in PN 1.0 in including jointing material such as rubber gasket,bolts,nuts,etc direct integrally all as specified and as directed by Eng-in-Charge Make: Kirloskar/ISI MARK or kARTAR ,
Supply and Fix in repair underground armoured, PVC insulated, PVC sheathed, multi stranded copper conductor cable of 4 Sqmm 3 core, 1100 volts grade confirming to IS 694 and connecting complete including taking out old unserviceable damaged cable complete all as specified and directed. Make: Havells/Finolex/Polycab
All as per Item No 14.00 herein before but of size 6 sqmm 3 core
Testing of portable sample collected from STP Tondon camp ,BT area,200KLD,STarea125KLD Amla and testing report required from through reputed laboratory/Regional Public Health laboratory IN Nagpur/Betul as per BIS -10500:2012 for sewage treated water are required folowing parameters: Parameter for waste treated water quality BOD MG/L- <10 COD MG/L <150 TSS MG/L <10 COLI FORM COUNT COUNTS/100ML RESIDUAL CHLORINE <1.0 mg/Ltr
Air Blower For STP M&L for opening air blower set twin lobe type of capacity 250 m3/hr make Everest, Air cooled blower & motor coupling after isolating the electric and air pipe connections opening the air compressor set for repair/overhauling & servicing of compressin , proper alignment of shaft etc including replacing the items with new items given vide item No 10 below, reassemblying the pumpset greasing connecting, testing and commissioning complete including necessary Lathe works all as specified at 360 KLD STP at AF Amlar Note :- Major Spares Parts will be measured & paid seperatly.as supply only
Supply only spare parts for Air blower follows:-
Supply Only Blower Bearing of size suitable for 250m3/hr usha make air blower
Supply Only Blower V Belt of for suitable size
Supply Only Blower Pulley of size 250m3/hr Everest make air blower
Supply Only Blower Oil Seal & Packing
Supply Only Blower Sucton Filter suitable for air blower cap 250m3/hr usha make air blower
Supply and fill Blower Oil No. 90 Servo/Shell
Material and labour for cleaning of underground water storage tank/sump after scrapping out the scales/deposits from all inner surfaces of sump thoroughly washing with bleaching powder solution (mixed @ 0.5 Kg of bleaching powder of chlorine content 30% per 1000 liters of water), bailing out the settled materials completely away from the site within 100 metres distance, cleaning the tank with clean water and finally sterilizing the tank as mentioned in notes below and resetting the existing level readings complete including taking down and re-fixing of foot valve after necessary cleaning, repairs etc., and replacing minor parts if any required for proper functioning of foot valve, testing and writing “TANK CLEANED ON…..”(date), “DUE DATE ON…..(date) with 10 cm size white letters on black back ground by engaging skilled artist using best quality synthetic enamel paint all as specified and directed by Engr-in-Charge for the following sizes:-
50,000 glns capacity water storage tank at Filter House
25,000 glns capacity underground sump at site C
1,00,000 glns capacity underground sump at Malanjhiri Pump House
All same as per item No. 19 here in before but for RCC Jack Well of capacity 22,000 glns at Kudmud Pump House
All same as per item No. 19 here in before but for RCC over head tank at 80 feet staging of capacity 2,00,000 glns having two compartments at Filter House.
Note for Item No 18.01 to18.04& 19:- The contractor should follow the following procedure in addition to above which demeed to be included in the contractor quoted rate. (a) Mechanized removal of all dirty water by using high capacity submersible pumps. (b) Removal of sludge by using vaccum operated pump (c) Cleaning of walls, ceiling and ground by high pressure rotary jet of 12 Kg/sqcm pressure. (d) Removal of all dirt particles by industrial wet vaccum cleaner leaving the tank physically cleaned as per Engr-in- Charge satisfaction. (e) Sterilization of tank by agents eco-friendly, bio-degradable and highly effective against all pathogens, or approved chemical. (f) Sterilization of tank atmosphere by industrial UV radiator leaving the tank complete sterilized (g) All the required Tools and plants, lubricants/oils and materials will be supplied by the contractor during the work. (h) Fresh air to be blown into the tank for a period before allowing a person to enter. The cleaner should wear protective clothing, including gloves, a boots, Safety Helmet and glasses. Contractor should make sure someone remains outside the tank, next to the access hatch all the time in case the cleaner has an accident. NOTE-:The availability of gas masks and portable ventilators would be made available by the contractor at site during cleaning operation.
M&L for taking out carefully complete filter media from the existing gravity filter at filter house and stacking in segregation size/ item wise (viz. gravel/pebble/ grit/ sand) outside the plant house at a distance exc 20 m and n.exc 50 m and cleaning the all filter media (viz. gravel/pebble/ grit/ sand) using bleaching powder and water including refiling the cleaned filter media at the same location complete all as specified and directed.
M & L for unused and fresh quartz white sand for filter media conforming to the following specifications complete all as specified and directed. Bulk Density:1600Kg/Cum Uc less than 1.5 % Acid solubility less than 5% Silica contents-90% Size 0.4-1.2mm
Material and labour for unused and fresh pebble media of sizes 12-25 confirming to the following specifications complete all as specified and directed Bulk density 1500kg/Cum UC less than 1.5% Acid solubility less than 5 %
Material and labour for unused and fresh pebble media of sizes 20-40 mm confirming to the following specifications complete all as specified and directed Bulk density 1500kg/Cum UC less than 1.5% Acid solubility less than 5 % Note Items Nos 22 to 24:- 1.) The quality and testing requirement of filter media supplied by contractor for use in pressure filter shall conform to IS: 8419 (Part -I) – 1977 (Reaffirmed 2001). 2.) The quality testing certificate of filter media is to be produced by the contractor before taking payment. 3.) The filter media shall be tested from any authorised laboratory after getting written approved by GE. expenditure against testing will be deemed to be included in qouted rate.
Material & Labour for complete removal of existing treatment of potable water tank by removing old painted surfaces using paint removers or burning off by blow lamps and cleaning with scrapers etc., and applying two coats nontoxic, non-corrosive water proof coating over a coats of primer inside the tank complete all as specified and directed. Make:- Sikagard-67, Dr Fixit Pidifine 2K, Clean Tech PW or equivalent as certified by CFTRI, Mysore for potable water/ BIS Note:- a) Surface preparation and application procedure shall be as per manufacturer’s guidelines and directions of Engineer-in-Charge. b) The paint used should not contain any harmful chemical content to pollute drinking water. A manufacturer certificate for the same is mandatory and contractor must produce the certificate as mentioned above before application to Engineer-in-Charge.
Supply and fix in repairs lamella clarifier plate made out of FRP (Fibre reinforced plastic confirming to BIS standards) of size 1210mm x 910mm x 3mm complete all as specified and as directed.
M&L for taking out carefully lamella clarifier plate made out of FRP (Fibre reinforced plastic confirming to BIS standards) of size 121cm x 91cm x 3 mm thick from plant including cleaning using bleaching powder with water and refixing in same position complete all as specified and as directed.
M&L for taking out existing of UPVC header and lateral pipes of bore 50 mm dia without causing any physical damage and cleaning the same with clean water and bleaching powder and refixing the same in old position including replacement of damaged minor fitting if any required for proper operation such as rubber gasket, bend, tee etc. complete all as specified and directed.
S&F in repairs UPVC (SCH - 80) header and lateral pipes of bore 50 mm dia with necessary fittings and nylon net cover suitable for multi inlet/ outlet of sand filter complete all as specified and directed. Note: Nylon net cover will be measured and paid separately as supply only.
Supply only nylon net cover suitable for multi inlet/outlet pipe of sand filter all as specified.
Material and labour for refilling chlorine gas from government authorised agency in department cylinders of 100 kgs capacity including transportation from and to the filling agency and replacing weared and teared parts etc., if any noticed before refilling complete all as specified and directed. Note: Contractor has to obtain necessary certificates for cylinder and chlorine gas from respective departments of Government Of India all deemed included in quoted rate.
Supply only calcium hypochlorite granules having chlorine content => 65% in air tight containers all as directed. Make:- Grasim Industries (or) any other equivalent ISI marked make shall be used after getting approval from GE Note:- Supply only items shall be taken over on charge through necessary Receipt Voucher duly signed by all concerns
Material and labour for testing potable water sample from the nearest district Laboratory, P.H.E. Madhya Pradesh including transportation complete all as specified and directed. Note:- The rate quoted by contractor includes the following: 1. Collecting water samples in sterlised containers from the location as directed by Eng-in-Charge 2. Transporting the collected sample immediately to the lab and submitting the test report to the Eng-in-Charge.
S & F in repairs following items for Diaphragm motor of capacity 0-20LPH with discharge tubing size 6mm/8mm and discharge pressure upto 5kg/sqcm as per sample Make:- E-Dose
PTFE Diaphragm with gasket
Suction valve assembly
Discharge valve assemby
Elastomer sealing set
Diaphragm motor pump set
S & F in repairs 50 mm dia PVC stirrer suitable for Diaphragm type chlorine doser as per sample shown by Eng-in-Charge.
Supply and fix in repairs Coiled Copper Tube Connector consists of an annealed copper tube of outer dia 3/8" inch/ 10 mm with Brass Nipples and Brass Unions 5/8" BSP [F] on either side to suit chlorine container valves; including brazing the brass nipple to copper tube complete all as specified and directed.
S & F in repair PVC 6mm/8 mm strainer for chorine doser machine
S & F repair of 20mm bore valve made of Aluminum Silicon Bronze to be mounted on chlorine gas cylinder including all necessary accessories having maximum working pressure 500PSI, burst pressure 7200PSI conform to relavant IS complete all as specified and directed.
Taking up of old unserviceable shaft,stirrer etc from liquid chorinator and repalcing the same with new shaft made out of UPVC pipe 15 mm, with length 45 cm approx. mounted on two sets of ball bearing operated via belt (new) attached with 1 HP motor including necessary alteration ,welding etc al as specified and as directed by EIC.
Demolition of brick valve chamber of size 1500mm x 1500mm x 1200mm (Internal), including PCC coping and removing the debris away from site to a distance exc 50 metre but not exc. 100 metre complete all as directed.
M&L for construction of valve chamber of size 1500mmx1500mmx1200mm (Internal) with fly ash brick masonary 230 mm thick in CM 1:6, PCC 1:4:8 type, D2 foundation 75 mm thick, finished fair and even, PCC 1:2:4 type, B1 coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar 1:4 plaster on exposed surfaces of brick wall (both internal and external), mild steel cover of 3.00 mm thick inclduding mild steel angle iron 40x40x6 mm size frame fixed to PCC coping with the same size of angle iron hold fast and with necessary handle and locking arrangements, metal surfaces duly painted with two coat of black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surfaces with 3 coats of white wash including necessary excavation and earth work complete all as specified and directed.
Demolision of brick valve chamber of size 900mmx600mmx1000mm (Internal), including PCC coping and removing the debris away from site to a distnace exc 50 metre but not exc. 100 metre complete all as directed.
M&L for construction of valve chamber of size 900mmx600mmx1000mm (Internal) with fly ash brick masonary 230 mm thick in CM 1:6, PCC 1:4:8 type, D2 foundation 75 mm thick, finished fair and even, PCC 1:2:4 type, B1 coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar 1:4 plaster on exposed surfaces of brick wall (both internal and external), mild steel cover of 3.00 mm thick inclduding mild steel angle iron 40x40x6 mm size frame fixed to PCC coping with the same size of angle iron hold fast and with necessary handle and locking arrangements, metal surfaces duly painted with two coat of black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surfaces with 3 coats of white wash including necessary excavation and earth work complete all as specified and directed.
M&L for oiling, servicing, greasing of existing manually operated gate of check dam of size 3.0x1.5 metre at the depth of 9.5 Mtr below the ground level at Kudmud pump house including taking off the sluice gate on other side of check dam and refixing the same after necessary reapirement and refixing the same including fabricating and making good dents on edges of gate bolts holes with additional reinforcement of 50x6 mm flat with drilled holes on the edges all round suitable rubber insertion sheet with new set of bolts nuts all as directed.The Job includes repacement of Supply and fix in repair ball bearings suitable for 40 mm inner dia pipe made of stainless steel at the kudmud dam gates spindle by detaching the handle etc. inclusive of all alteration required all as directed by Engineer-in charge.Make:SKF,Tata,NBC (NEI)
M & L for Running welding in repairs for thickness of metal to be welded not exceeding 6 mm all as specified and directed.
Supply only rubber sheet 3 mm thick
Supply and fix water level indicator in repairs at overhead tank upto 80 feeet staging float and board type with specification as measuring range 1-6 mtrs, float valve , wire pointer M.S. epoxy coated red coloured, scale 6" wide, housing , pulley and appropriate MS channell for support and mounting including all parts being alluminium powder coated. The job involves all alteration at site complete all as specified and directed.
Overhauling and servicing of vacuum type gas chlorinator system of capacity 0-1 kg per/ hour bearing model No SM117 of Supreme Technologies, Nagpur by authorised OEM including replacing old unserviceable spare parts and testing complete all as specified and directed. Note: (i) Cost of spare parts replaced shall be measured and paid separately as supply only under relevant items herein after. (ii) Labour charges for replacement of spares parts if any required during servicing of AC’s deemed to be included in the quoted rate. (iii) OEM Test Report shall be submitted by the contractor after testing.
Supply only following spares required for replacement during the process of Overhauling/ servicing of the vacuum type gas chlorinator system of capacity 0-1 kg per/ hour bearing model No SM117 of Supreme Technologies, Nagpur:- Note: Spare parts supplied shall be from the authorised delar of OEM.
Vacuum regulator diaphragm
Vacuum regulator 5/16 X 2 ½” Long 8 nos.
Vacuum regulator O ring.
Inlet valve assembly.
CPVC union O ring
Yoke clamp gasket.
Connector gasket.
Control valve O ring.
Flow meter long stud
Flow meter long stud bolt.
Ejector diaphragm
Ejector Long stud.4 nos.
Ejector Nut 8 nos.
Spring.
PU tubing.
Isolation needle valve
M&L for preparation of internal surfaces of overhead reservoir of cap 2.00 lakh gallon after cleaning and painting of internal surfaces with two coats of non toxic, non corrosive, epoxy resin coating of brand name sikaguard-67 or Dr Fixit dampguard (pidilite) as per manfacturer's instructions inside the tank complete all as specified and as directed .
M&L for preparation of internal surfaces of under ground sump of capacity 50000 gallons and 1.00 lakh gallons after cleaning and painting of internal surfaces with two coats of non toxic, non corrosive, epoxy resin coating of brand name sikaguard-67 or Dr Fixit dampguard (pidilite) as per manfacturers instructions inside the tank complete all as specified and as directed .
RAW SEWAGE FEED PUMP SUBMERSIBLE NON CLOG PUMP SET:- M&L for opening pump set RAW SEWAGE FEED PUMP of flow capacity 7.5kw/10 hp with 50 hz and 2200 rpm any make from motor coupling after isolating the electric and pipeing connections opening the pump set for repair/overhauling & proper alignment of shaft etc including replacing the items with new items given vide item No 49 below, reassemblying the pumpset greasing connecting, testing and commissioning complete including necessary Lathe works all as specified at 360 KLD STP at AF AMLA Note :- Major Spares Parts will be measured & paid seperatly as supply only
Supply only spare parts for pump set for fixing against sewage transfer pump as follows:-
Supply only pump shaft sleeve/bush made out of gun metal
Supply only key for main shaft/impeller
Supply only pump Shaft
Supply ball/roller bearing complete
Supply only impeller
Material and labour for rewinding the RAW SEWAGE FEED PUMP SUBMERSIBLE NON CLOG PUMP SET by providing high quality of class 'B' paper insulation inside the slots, and rewinding with super enamel copper wire of same size and gauge as per existing rapping up with high quality cotton tape and varnishing with super quality oil including drying upto desired temperature and desired time complete including taking old burnt out copper winding, insulation material and cleaning the slots complete all as specified and directed for the capacity of motor 10 HP 3 phase, 415 Volts 50 HZ
M&L for preparation of external surface Including grouting and rendering of damage surface & matching with the exiting surface of overhead water storage tank of 60ft staging ( 1 x 200000 gallon at Filter House ) by scrapping all dirt’s dust, rust from roofs and overhead tank wall etc and then apply with two coats of heat reflective paint even and smooth of white colour with blue colour bands all complete as directed by Engr-in-charge. Make of Paint : COOL-ROOF-AV Note: Contractor has to ensure the safety of the working personnel and the quoted rate inclusive the rate of tools and equipments needed for the job.
Removal of bio-degradable bee-hives wild growths from the structure tank and member of the overhead reservoir complete including wild bees with suitable application of fuming smoke or chemical fog application and applying a coat of alergent for keeping away or return of bee-hives (All the bee-hives on the tank shall be removed and cleaned) Note : The removal of bee-hives shall be carried out with total precautions so that wild bees do not get the time and opportunity to attack the public in the locality.
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Raj Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .