Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.7 L+₹75,920 (10.9%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Higher amount quoted in comparison of L1 | |
| 3 | L3₹8.0 L+₹1.1 L (15.1%)Rejected-Finance | L3 | Rejected-Finance Higher amount quoted in comparison of L1 |
Tender Value
₹8.2 L
EMD Value
₹16,400
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I POKARAN
MILITARY ENGINEER SERVICES ASST GARRISON ENGINEER I POKARAN MILITARY STATION POKARAN-345021
REPAIR AND MAINT OF SUMMER COOLING APPLIANCES IN AREA UNDER AGE (I) POKARAN
2024_MES_658775_2
8241/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I POKARAN
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I POKARAN
₹16,400
Yes
16 Oct 2024
29 Jun 2024
11 Sept 2024
29 Jun 2024
4 Sept 2024
15 Jul 2024
1 Jul 2024 - 8 Jul 2024
Amount
Supply and fix in repair condenser cooling fan motor with fan blade of cap 1/30 HP suitable for water cooler of cap 80/40, 100 ltrs. Make - AUE complete all as specified & directed by Engr In Charge
S&F in repair, float valve high pressure of PTMT body with epoxy coated Aluminium rod and high density plastic ball screwed for 15 mm bore iron pipe, weight not less than 140 grams/each, fixed to water cooler complete all as specifide & directed by Engr-in -charge.
S&F in repair, 15 mm bore bib tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
S&F in repair, starting capacitor 80-100 MFD suitable for water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
S&F in repair, running capacitor 40-60 MFD suitable for water cooler of any capacity complete all as specifide & directed by Engr-in -charge.
S&F in repair, thermostate suitable for water cooler of any capacity complete all as specified & directed by Engr-in -charge.
S&F in repair, relay with over load protection suitable for 40 to 150 liters capacity water cooler complete all as specifide & directed by Engr-in -charge.
Taking down old unsv GI Tubing of 15 mm from floors complete all as specified & directed by Engr In Charge
M&L for 15 mm bore mild steel galvanized water tubing, medium grade with all fitting and accessories complete fixed to wall and celling or laid in floors complete all as specifide & directed by Engr-in -charge.
Removing the unserviceable compressor sealed unit of any make from water cooler of capacity 40/80 liters after cutting copper tubing without any damage to exisiting parts, replacing compressor with new compressor of same make refixing of compressor on bace & jointing of copper refrigerant pipe line filter etc & charging gas to required level, including cleaning of fins, leakage testing etc including testing & commissioning for smooth functioning complete all as specified & directed by Engr-in -charge.
S&F in repair, condensing coil suitable for water cooler of capacity 40/80 liters complete all as specified & directed by Engr-in -charge.
M & L for flushing,pressurising the system , leakage testing vacuumisation and GAS CHARGING with refrigerant gas (R-134a) at apprporiate pressure including testing at site for water cooler of cap 80/40 ltrs complete all as specified & directed by Engr In Charge
M&L for cutting and removing uncervicable freezer unit of refrigerator of capacity 165 to 210 liters of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specifide & directed by Engr-in -charge.
M&L for cutting and removing uncervicable freezer unit of refrigerator of capacity 286 to 310 liters of any make, and supply and fix new freezer unit including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specifide & directed by Engr-in -charge.
S&F in repair, thermostate suitable for refrigerator 165 to 310liters capacity complete all as specifide & directed by Engr-in -charge.
Removing the unserviceable compressor sealed unit of refrigerator of capacity 286/310 liters of any make, & replacing with new compressor of same make & model, rein-stalling in orignal position with all accessories like relay with over load protector, filter & recharging of refrigerant gas complete including testing & commissioning for smooth functioning complete all as specified & directed by Engr-in -charge.
Removing the uncerviceable compressor sealed unit of refrigerator of capacity 165/175/195 liters of any make, & replacing with new compressor of same make & model, rein-stalling in orignal position with all accessories like relay with over load protector, filter & incl charging of refrigerant gas complete including testing & commissioning for smooth functioning complete all as specified & directed by Engr-in -charge.
M & L for flushing, pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-134) at apprporiate pressure including testing at site for refrigerator of cap 165/195 ltrs complete all as specified & directed by Engr In Charge
M & L for flushing,pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-134) at apprporiate pressure including testing at site for refrigerator of cap 285 / 310 ltrs. complete all as specified & directed by Engr In Charge
S&F lamp with holder for refrigerator any capacity and any make incl removing old unsv lamp all as specified and directed by Engr In charge
Dismantling unserviceable compressor sealed unit of any make from deep freezer of cap 310 liter after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge
M&L for removing the old burnt out condenser fan motor of Deep freezer of capacity 310/220 liters from position and replacing with new motor and reassembling and fixing in position complete all as specifide & directed by Engr-in -charge.
Dismantling unserviceable compressor sealed unit of any make from window type Air Conditioner of cap 1.5 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge
" -ditto- all as item No 23 above but 2.0 TR cap window type Air Conditioner
Supply and replace BLOWER FAN MOTOR 1/8 HP suitable for window type AC cap 1.5/2 ton complete all as specified & directed by Engr In Charge
S&F running capacitor 45/50 MFD suitable for A/C of cap 1.5/2.0 TR complete incl removing unserviceable running capacitor all as specified & directed by Engr In Charge
S&F starting capacitor 60-120 MFD suitable for A/C of cap 1.5/2.0 TR complete incl removing unserviceable starting capacitor all as specified & directed by Engr In Charge
S&F Aluminium fan blade suitable for condensing side of window type AC 1.5/2.0 TR cap complete all as specified & directed by Engr In Charge
S&F PVC blower blade heavy duty suitable for evaporative side of window type Air conditioner 1.5/2.0 TR cap complete all as specified and directed by Engr in charge
S&F starting relay suitable for window type AC 1.5/2.0 TR cap complete all as specified and directed by Engr In Charge
S&F over load protector relay suitable for window type AC 1.5/2.0 TR cap complete all as specified and directed by Engr In Cahrge
S&F thermostat suitable for 1.5/2.0 TR cap window /Split type AC complete all as specified and directed by Engr In Charge
S&F air filter for split type AC 1.5 TR cap ( Set of three) complete all as specified & directed by Engr in Charge
Dismantling unserviceable compressor sealed unit of any make from external unit of Split type Air Conditioner of cap 1.5 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube , filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge
Supply and replace BLOWER FAN MOTOR 1/8 HP suitable for split type AC cap 1.5 ton complete all as specified & directed by Engr In Charge
S&F in repair PVC flexible drain out pipe 1.5 mtr length of Split type , heavy duty of 15/25mm dia and 1.5mm wall thickness complete with fittings , spacers and saddles etc complete all as specified & directed by Engr In Charge
S&F repair wireless remote control (Micro processor ) unit suitable for Split type AC any cap testing & complete all as specified and directed by Engr In Charge
Taking down for serviceing the cooling side blower motor of cap 1/30 HP to 1/20 HP from split type AC & M&L for new motor and refixing of motor in original position with new washers nuts & bolts incl testing complete all as specified & directed by Engr In Charge
S&F PCB circuit of existing size & shape to split type AC having cap 1.5 TR complete all as specified & directed by Engr In Charge
M&L for servicing of Split /window type AC of Cap 1.5TR/2.0 TR of any make by opening the conderser unit fixed on roof top & cooling unit fixed inside the building, cleaning the complete conderser unit & cooling unit incl fins &checking / testing of all parts for its serviceablity & oiling/greasing of motors , replacing the worn out bushes of blowers & rectfication of unuseal noises , checking of refrigerent standing pressure, topping up of refrigerant gas upto the reqd level, replacemnt of minor parts such as nuts bolts & washers etc & reassembling of complete unit incl testing & commissioning for smooth functioning complete all as specified & directed by engr in charge
M & L for flushing, pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-22) at apprporiate pressure including testing at site for window/Split type AC cap 1.5 ton complete all as specified & directed by engr in charge
S&F single pole and neutral enclosure with metal clad plug & socket 20 Amps & with MCB SP 20 Amps , 240 Volt complete all as specified and directed by Engr in Charge
M & L for flushing, pressurising the system , leakage testing vacuumisation and gas charging with refrigerant gas (R-134) at apprporiate pressure including testing at site of AC 7.5 TR capacity Package type AC complete all as specified & directed by Engr-in -charge.
Dismantling unserviceable compressor reciprocating/scroll type of any make from package type Conditioner of cap 7.5 TR after cutting the copper tubing without any damage to existing parts, replacing the compressor with new compressor refixing of compressor on base with suitable capiliary tube, filters etc & jointing of copper refrigerant pipe line, with charging of suitable refrigerant gas to required level incl cleaning of condenser fins leakage testing etc incl testing & commissioning for smooth functioning complete all as specified & directed by Engr in Charge
M&L for removing the conderser fan/blower motor from Package type Air conditioner of 7.5 TR cap with new motor and refixing of motor in original position with new washers nuts & bolts incl testing complete all as specified & directed by Engr In Charge
S&F in repair fully automatic star delta starter (EASD) type for compressor motor having inbuilt single phase preventor, no volt and under volt protection over load peotection. Reverse phasing protection of suitable capacity as recommended by manufacturer as per the load of the compressor motor all as specified and directed by Engr-in-charge.
Dismentalling of 2 HP pump motor of cooling tower and S &F new 2 HP pump motor 3 phase complete with all as specified and as directed by Engr-in-charge
S&F PCB circuit of existing size & shape to Package type AC having cap 7.5 TR complete all as specified & directed by Engr In Charge
S S enterprises (BID ID -3082572)
M/s Rashid Mohammed (BID ID -3082805)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .