Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC 106 AIR FORCE CENTRAL SCHOOL SCHEME JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0106649 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹21.3 L+₹3.9 L (22.3%)Rejected-Finance 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance LOWEST | |
| 3 | L3₹22.1 L+₹4.7 L (27.0%)Rejected-Finance 43 MANAK BHAVAN FIRST FLOOR GUMANPURA KOTA 324 007 RAJASTHAN | KOTA | KOTA | RAJASTHAN | 324007 | L3 | Rejected-Finance LOWEST |
Tender Value
₹29.9 L
EMD Value
₹59,800
Closing Date
14 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI T C SHISHODIYA, DCWE (C)
MULTAN LINE ARMY AREA JODHPUR
Special Repair of HT Equipments against BER and other Allied Works under GE (Army) Utility
2020_MES_385060_1
CWE (A) JODH-93 OF 2020-21
Open Tender
Civil Works
Item Rate
150 days
GE(Army) Utility
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE(Army) Utility
₹59,800
Yes
16 Feb 2021
9 Oct 2020
16 Nov 2020
9 Oct 2020
14 Nov 2020
30 Oct 2020
60 days
Amount
Supply, Installation, testing , Commissioning of 11kV Air Insulated Indoor type Switchgear Panels with maximum system voltage rating of 12kV consisting of 1 Incomers of 630A VCB and 3 Outgoing Feeders with 630A VCB ,Busbar Rating of 630A,Short Circuit Capacity of 26.3kA . Copper Bus-bars shall have full Voltage Sleeving on it and shall be self-supported type ,i.e. without any support insulators . The Incomer Panels shall contain Line PT arragement . The Panel, Vacuum Circuit Breaker , Vacuum Bottle, Numerical relays shall be of same make as the Panel Manufacturer . Bus bar should be of electrolyte Copper.The panel shall be tested for IAC AFLR for 25kA/1s. . The Circuit Breaker shall be of floor rolling design with encapsulated Vacuum bottles, and shall have all fool-proof interlocks as : Interl+B4ocks shall be provided to prevent a ‘Closed’ breaker to rack out from ‘Service’ to ‘Test’ /'Isolated’, position or insert a ‘closed’ breaker from ‘Test’ to ‘Service’ position. In either case the breaker contacts must remain in open position. Before racking out the breaker must be fully discharged from any static charge. Switchgear should be SCADA Compatible. Panels shall be tested for Seismic Zone -IV as JodhpurStation falls under the same Earthquake Zone .Type Test reports shall be submitted for the same. The Switchboard shall be configured as follows : 1 Incomers of 630A VCB and 3 Outgoing Feeders with 630A VCB Incomer CTs : 200-100/1-1, 5VA, Cl-5P10, Cl-1.0, Outgoing Panel CTs : 100-50/1-1,5VA,Cl-5P10,Cl-1.0, Incomer VTs : 11000/V3/110/V3/110/3,50VA,Cl-1.0,3P, Incomer IEDs : Feeder Protection and Control Relay, Protections 50,51,50N,51N,with communication port - ABB make REF601, Outgoing IEDs : Feeder Protection and Control Relay, Protections 50,51,50N,51N,46,49,95, Measurement for 3I, I0, 4 DI + 6 DO, One front RJ45 Port, Two Rear FO(LC) Port for IEC-61850 Protocol, Drawout Type with CT Shorting feature. Ammeter, Annunciator window, MFM with communicable port. Other necessary items like AC/DC MCBs , Power pack of 110VDC with each panel, TNC Switches, Indication Lamps (R,Y,B,ON,OFF,Spring Charge,Test,Service) shal be considered in the scope of Panel shall be factory fitted only no system house panel accepated .
Supply and laying & testing cable XLPE installed screened PVC bedded, galvenised steel strip or wire armoured electric power cable (heavy duty) 11000 Voltts grade (E) with stranded aluminium conductor of size 95 sqmm 3 coreconfirming to IS 7098 (Pt-II) laid in trenches/ducts /encased in GI pipe /fixed to pole all as specified and directed by Engineer-in-Charge
Supply and fix cable jointing kit for 11KV grade cable for indoor termination heat shrink type with jointing material and accessories suitable for 3 core XLPE armoured Al conductor of size 95 Sqmm all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 11KV grade cable for outdoor termination heat shrink type with jointing material and accessories suitable for 3 core XLPE armoured Al conductor of size 95 Sqmm all as specified and directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m wide and n.exc. 1.5m in depth for laying of cable and foundation of pole in soft/loose soil complete all as specified and directed.
Returning filling in soil and well ramming in layers n. exc. 25cm including spreading, levelling and watering all as specified and directed.
Removing excavated material (soil) and depositing at a distance not exceeding 50m where directed.
M&L for screened un-washed river sand cushioning to U/G cable for cushioning 8cm below the cable and 15cm above cable and punned down to 18 cm all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1flat size 300mm x 180mm x 40mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection
Motorized Auguring/drilling in road at 90cm depth of dia suitable for laying of 80/100mm dia GI tubing pipe.
M&L for Earthing complete with copper earth plate electrodes 600x600x3.15 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to coppe strip 20 x3mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion with watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. NOTE:- Rate included for excavation & earth work in any type of strata as shown in electrical plate No 3 and the earth resistance shall be less than 5 ohms.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip
M&L for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crosing including claps, nut bolt etc all as specified and directed of size 100mm
M&L for GI tubing medium grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crosing including claps, nut bolt etc all as specified and directed of size 150mm
RISING ELECTRICALS
M/s Prem Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .