Installation of High mast pole with LED lights under Booth No. 127 of Kodalia II GP under Amader Para Amader Samadhan Scheme
2026_WBPWD_995511_1
WBPWD/AE/HESD-I/ NIeT-16 (2nd Call) of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Hooghly
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,077
26 Feb 2026
29 Jan 2026
12 Feb 2026
29 Jan 2026
10 Feb 2026
29 Jan 2026
Supply & erection of 9.0 mtr. Hot Dip Galvanised (86.65 micron dry film thickness) Octagonal Pole, as per BSEN 10025 ; ASTM A572 ; IS 5986 : IS 4759/2629, ASTM A123 and BSEN IS 1461 standard. The pole should be 9.0 mtr. Long, bottom dia. - 155mm. Top dia. - 70mm, thickness - 4mm, continuously tapered and shall have octagonal cross section with pole cap at top, necessary cleat attachment / hanger incl. ring bracket suitable for fixing 6 nos. light fittings. Base plate having dimension 260x260x16 mm and 04 nos. 'J' type foundation bolt with double nut and plate washer, bolt dia. 24mm, PCD - 250mm, bolt length - 750mm, projected bolt length - 125mm (These dimensions are subject to tolerance as per IS-2102 except for bending radius). Make - Galpol / Transrail / BP Poles / Utkarsh / Electropole
Construction of suitable shallow reinforced foundation as per standard design as per the manufacturer with 1:2:3 cement concrete M-20 gr. for the High Mast considering the safe soil bearing capacity at site as 10T/sq. mtr. TMT steel as per IS (0.5% of CC volume) and foundation having 1000mmx1000mmx100mm thick base and main column (pillar) having 800mmx800mmx1200mm long dimension that conforms safe bear of high mast with around height of 300mm above ground level, incl. all materials and labour including the cost of one set foundation nuts & bolts of 750mm made out of M24 gr. steel and installation at site with wiring complete in all respect i.e. entire satisfaction of Engineer-in-Charge. This Civil foundation work incl. erection up to 9 mtr. octagonal mast tower by earth work in excavation of foundation trench approx. complete as per modern engineering practice.
S & F 240V, 100W LED Flood light luminaire (Make - Crompton, Model - ROVER PLUS, Cat no. - TFS-504-100-57-NL-SL-GL-NBK or equivalent make of Philips / Bajaj / Wipro) as per direction of E.I.C [NS]
Supply of 3/3.5/4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make - Gloster/Nicco/KEI/Polycab] 2 Core 6 Sq. mm [ NS ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed [F- 2/1(a)]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 2 Core 6 Sq. mm [F4/7(a)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 Core 6 Sq. mm [F5/8(b)(ii)]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 40 mm dia [F-6/11(c)]
Interconnection of LED luminaires by PVC Insulated Unarmoured Copper Conductor cable incl. all accessories for Working Voltage up to 1100 Volts [ Make - Gloster/ KEI /Polycab] 3 Core 1.5 Sq. mm [ NS ]
Supplying & Fixing GI waterproof type looping cable box size 200 x 150 x 100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sq. mm. PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [H5/(H)5]
S&F of 250V single timer DB (equivalent to 10 way SPNDB in size) with double acrylic door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 32A DP MCB (C-curve 10ka) and 1 no. 24 hr. analog time switch and 1 no. 25A modular type power contactor complete with internal wiring with suitable size of copper wire includ LED indicator and earthing attachment as per direction of EIC [NS]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [G-1/1(a)]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe [G-1/2(a)]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [G-2/3(a)]
Add GST 18 %
Add Labour Cess 1%
stage.html
html • 0.02 MB
cancelled_1.PDF
pdf • 0.33 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 1.48 MB
BOQ_2436094.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .