Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 CrAccepted-AOC | ₹2.7 Cr | 1 | Accepted-AOC 1 |
| 2 | 2₹2.7 Cr+₹5.0 L (1.89%)Rejected-AOC | ₹2.7 Cr+₹5.0 L (1.89%) | 2 | Rejected-AOC 2 |
| 3 | 3₹3.6 Cr+₹91.3 L (34.4%)Rejected-AOC | ₹3.6 Cr+₹91.3 L (34.4%) | 3 | Rejected-AOC 3 |
| 4 | Not Admitted-Fee | - | - | Not Admitted-Fee Fee not received |
| 5 | Not Admitted-PreQual/Technical | - | - | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.8 Cr
EMD Value
₹3 L
Closing Date
18 Jun 2020, 11:00 amClosed
SE ETC 1 Panki Kanpur
SE ETC 1 Panki Kanpur
Work
2020_UPTCL_445629_1
ET-215/ETC-1(K)/2019-20
Open Tender
Electrical Works
Fixed-rate
180 days
Kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹11,800
PNB AC No0727002100004177
₹3 L
19 Jun 2021
7 Mar 2020
19 Jun 2020
7 Mar 2020
18 Jun 2020
7 Mar 2020
Amount
Shedule Of Supply Of Material -Q1 :-
Supply of Fabricated, Glavnized D/C Monopol for 400 KV & their anchor bolts, anchor plates and template and other accessories complete in all respect, etc.
(A) Tension Pole Type- PT(60(60D)BXA 26 Mtrs Complete in all respect for Ruling Span 280M
(B) Tension Pole Type- PDT60(60D)BXA 31 Mtrs Complete in all respect for Ruling Span 280M
ACSR Twin Moose conductor accessories :-
(A) Double tension string with hardware fitting for ACSR Twin Moose conductor compression type complete in all respect.
(B) Vibration damper for ACSR moose conductor
(C) Mid span joints for ACSR Moose Conductor
(D) Repair sleeve for ACSR Moose Conductor
(E) Bundle spacer for ACSR Twin Moose Conductor
(F) Ragid Spacer for jumper for ACSR Twin Moose Conductor
(G) Carona Ring for ACSR moose conductor
(H) Vibration damper for 7/9 SWG E/W
(I) Tension fitting for 7/9 SWG E/W
(J) Pilot Fitting
(K) Copper Bond
INSULATORS
(A) Composite Polymeric Insulator String 400KV/160Kn
(B) Composite Polymeric Insulator String 400KV/120Kn
Providing of TMT reinforcement steel straightening, cutting bending tieing, lap/butt welding placing including binding with GI binding wire 18 SWG in all structural heights and depth, complete as per drawings, specficitation and directions of Engineer. The scope of work will also include application of one coat of cement slurry inhibitor solution as per manufracture's instruction of approved by the Engineer-in-charge
Shedule Of Erection -Q2 :-
(a) SURVEY
(b) CHECK SURVEY
(a) Setting of Anchor Bolts including all foundation work but excluding cost of Concret, shorting shuttering and installation of reinforcement bars etc.
(b) Setting of Stubs including all foundation work but excluding cost of Concret, shorting shuttering and installation of reinforcement bars etc.
Cost of excavation of 400KV Pole/pile foundation Column including all earth work, back filling, etc.
Cost of concreting Pole foundation Column with 1:1:5:3 mix concrete including cost of cement sand, stone, ballast forming, shoring shuttering and curting but excluding cost and installation of reinforcement bars.
Erection of monopoles with the help of Hydraulic crane of suitable capacity (crane including soil dosing, soil ramming and transpiration of:
(A) Tension Pole Type- PDT60(60D)BXA 26 Mtrs
(B) Tension Pole Type- PDT60(60D)BXA 31 Mtrs
Teck Welding of Bolts & Nuts
Laying, stringing, tensioning, clamping etc of S/C line 3 phase Twin Conductor includiing hoisting of insulators hardware fittings and jumpering etc.
STRINGING of E/W including all required accessories and hard wares, etc to complete the job in all respect.
EARTHING of tower footing including of earthing materials
Design of 400KV D/C Monopole type - various type of tension pole including nuts, bolts, washers & ladder etc and its foundation (design of pole & its foundation duly approved from CPRI/IIT Mumbai, Delhi, Roorkee and type Tested by any of the Govt. approved test lab i.e. CPRI/IIT Mumbai, Delhi, Roorkee
Shedule Of Pile foundation -Q3 :-
(A) Carrying out static routine vertical load tests as per relevant IS Codes including all arrangements for measuring deflections and submitting reports. This includes making of pile head ready for testing at the desired level, supporting/erection arrangement (including reaction piles/soil/rock anchors, if any) for the kentledge load.
(B) Non destructive integrity testing of cast-in-situ piles as per specifications, and submitting load.
Cement concreting for PCC/RCC work in base, raft and footing for the tower foundations including cost of shoring and shuttering including cost of cement
(A) 1:2:4 (1 Cement: 2 Coarse sand:4 graded stone aggregate 20 mm Normal size)
(B) 1:1:2 (1 Cement: 1 Coarse sand: 2 graded stone aggregate 20mm Normal size)
Cost of Piling of up to 20 Mtr depth including bulbs up to 800 mm dia, includes the lowring of Rainforcment & poring of Concret etc.but excluding cost of concret.
PSH TECHNO ENGG PVT LTD
Umawala Engineers Pvt. Ltd.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .