Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC CHATAPADMAPUR BATTALA RAMNAGAR CONTAI EAST MEDINIPUR PIN 721433 WEST BENGAL | CONTAI | EAST MEDINIPUR | WEST BENGAL | 721433 | L1 | Accepted-AOC AOC is issued | |
| 2 | L2₹16.4 L+₹1,175 (0.07%)Rejected-Finance SARBERIA NARAYANDARI PURBA MEDINIPUR PIN 721655 WEST BENGAL | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721655 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹16.4 L+₹1,200 (0.07%)Rejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | L3 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹32,846
Closing Date
1 Feb 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Tamluk , Purba Medinipur
SITC of AC Machine in replacement of old AC machine (approx 10 years old) at different places of , Tmralipta Govt Medical college and Hospital , Purba Medinipur(2nd Re tender)
2024_WBPWD_766950_3
WBPWD/EE/PMED/NIQ-62/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
tamluk
Please refer Tender documents.
3 documents required · 3 mandatory
₹32,846
Office of the Executive Engineer Purba Medinipu
5 Dec 2025
10 Jan 2025
4 Feb 2025
10 Jan 2025
1 Feb 2025
16 Jan 2025
15 Jan 2025
Amount
Supply & Delivery of Hi-wall Split Air Conditioner having following specification. Cooling Capacity - 5.2 kW (minimum) ISEER-3.5 (minimum) BEE Leveling : 2-Star or higher (July22-Dec 24) IS compliance - IS 1391 Refrigerant - R410A/ R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) necessary copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr [Make: Mitsubishi Electric / General / Mitsubishi Heavy]
Supply & Delivery of Hi-wall Split Air Conditioner having following specification. Cooling Capacity - 6.6 kW (minimum) ISEER-3.5 (minimum) BEE Leveling : 2-Star or higher (July22-Dec 24) IS compliance - IS 1391 Refrigerant - R410A/ R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) necessary copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr [Make: Mitsubishi Electric / General / Mitsubishi Heavy]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
Supply and laying of refrigerent copper pipe minimum thickness 1.15mm, liquid line 1/4" dia and gas line 5/8" dia(make- Royku/Mandeep) and insulation of copper pipe by nitril rubber insulation tube of minimum thickness 19mm(Make- Aroflex/Acoflex) incl. S&F of 4 core 2.5 sqmm PVC insulated copper wire for connecting indoor and outdoor units also rapping insulation and copper wire with GKB Gold raping tape.
Supply and laying of 19mm pvc drain pipe.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (AC Sarter
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (AC Plug Socket)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Make- Legrand) & necy. Connections.
Supplying and Drawing 1.1 KV single core stranded 'FRLSH' PVC insulated & unsheathed single core stranded copper wire (Make-KEI/Gloster/RR/polycab) of following size in the prelaid 20mm dia PVC rigid conduit and making necy. connection as required. 2 x (4 sqmm) + 1 x (2.5 sqmm) ECC wire from (HTPN DB to AC plug)
MAA NACHINDA ELECTRIC (BID ID -6019731)
B. ENGINEERING CO. (BID ID -6038363)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .