Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹8.8 L+₹1.4 L (18.4%)Rejected-Finance 001 HPS MARKET KANPUR GANDHI CHAURAHA RAEBARELI UTTAR PRADESH 229206 | RAE BARELI | UTTAR PRADESH | 229206 | L2 | Rejected-Finance Being L2 bidder | |
| 3 | L3₹9.1 L+₹1.7 L (22.3%)Rejected-Finance PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L3 | Rejected-Finance Being L3 bidder | |
| 4 | L4₹14.7 L+₹7.3 L (98.6%)Rejected-Finance 309 VINAYAK TOWER CUTTACK PURI ROAD BHUBANESWAR 751 006 | KHORDHA | ODISHA | 751006 | L4 | Rejected-Finance Being L4 bidder |
| Sl No | Description | Qty | Unit | Shree Mahavir Associates L4 | PRABHAT ENGINEERING SOLUTION AND SERVICES L1 | SMART ENERGY SOLUTIONS L3 | SHREE ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5m wide and n. exc 1.5m depth getting out in hard/dense of soil for taking out or laying of pipe line, laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed. | 40.5 | Cum | 223 ₹9,031.5 Lowest | 250 ₹10,125 | 290 ₹11,745 | 275 ₹11,137.5 |
| 2.00 | Returning & filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in hard/dense soil complete all as specified. | 18 | Cum | 55 ₹990 Lowest | 80 ₹1,440 | 80 ₹1,440 | 95 ₹1,710 |
| 3.00 | Removing excavated material soil to a distance n.exc 50m & depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. | 22.5 | Cum | 177 ₹3,982.5 | 70 ₹1,575 Lowest | 100 ₹2,250 | 125 ₹2,812.5 |
| 4.00 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for protection of cable prependicular to the direction of cable all as directed. | 1,000 | Each | 89 ₹89,000 | 39 ₹39,000 | 38 ₹38,000 | 30 ₹30,000 Lowest |
| 5.00 | M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as directed. Note : Punned thickness of sand shall be measured for payment purpose. | 24 | Cum | 788 ₹18,912 | 630 ₹15,120 Lowest | 650 ₹15,600 | 675 ₹16,200 |
| 6.00 | Supply and fixing in replacement GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed, | 6 | RM | 1,222 ₹7,332 | 880 ₹5,280 | 650 ₹3,900 Lowest | 825 ₹4,950 |
| 7.00 | Supply and Laying in replacement XLPE LT UG cable PVC insulated, bedded, GI strip or wired armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 120 Sqmm 3.5 Core laid in trenches or fixed on wall/floor/poles complete with cable glands & lugs cable route indicator as required all as specified and directed. | 10 | RM | 988 ₹9,880 | 700 ₹7,000 Lowest | 800 ₹8,000 | 750 ₹7,500 |
| 7.01 | All as per item No. 7 here-in-before but 3.5 x95 sq mm cable | 40 | RM | 898 ₹35,920 | 565 ₹22,600 Lowest | 670 ₹26,800 | 575 ₹23,000 |
| 7.02 | All as per item No. 7 here-in-before but 3.5 x 70 sq mm cable | 40 | RM | 766 ₹30,640 | 450 ₹18,000 Lowest | 510 ₹20,400 | 475 ₹19,000 |
| 7.03 | All as per item No. 7 here-in-before but 4 x 16 sq mm cable | 50 | RM | 255 ₹12,750 | 170 ₹8,500 Lowest | 220 ₹11,000 | 185 ₹9,250 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
20 Oct 2025, 6:00 pmClosed
Shri Himanshu IDSE EE
GE (I)(CG) Bhubaneswar, Military Engineer Services, Near School Integral Education, Campus-2, Coast Guard Complex, Pallaspalli, Bhubaneswar-751 020 (Odisha)
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIC UG CABLES LT PANELS TWO POLE STRUCTURE SWITCHGEARS HIGH MAST LIGHTS BOLLARD LIGHTS DG SETS AND OTHER MISC WORK AT CGRA AND CGAE BHUBANESWAR
2025_MES_733172_1
8612/BBSR/04/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BHUBANESWAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) (CG) Bhubaneswar
₹24,000
Yes
1 Dec 2025
29 Sept 2025
22 Oct 2025
29 Sept 2025
20 Oct 2025
13 Oct 2025
Amount
Excavation in trenches n.exc 1.5m wide and n. exc 1.5m depth getting out in hard/dense of soil for taking out or laying of pipe line, laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed.
Returning & filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in hard/dense soil complete all as specified.
Removing excavated material soil to a distance n.exc 50m & depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for protection of cable prependicular to the direction of cable all as directed.
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as directed. Note : Punned thickness of sand shall be measured for payment purpose.
Supply and fixing in replacement GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed,
Supply and Laying in replacement XLPE LT UG cable PVC insulated, bedded, GI strip or wired armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 120 Sqmm 3.5 Core laid in trenches or fixed on wall/floor/poles complete with cable glands & lugs cable route indicator as required all as specified and directed.
All as per item No. 7 here-in-before but 3.5 x95 sq mm cable
All as per item No. 7 here-in-before but 3.5 x 70 sq mm cable
All as per item No. 7 here-in-before but 4 x 16 sq mm cable
All as per item No. 7 here-in-before but 2 x 10 sq mm cable
S&F in replacement bracket for street light made out of 1.5 Mtr long, 40 mm bore GI tubing, medium grade bent to required angle/ shape with and including necessary clamps, nuts, bolts, & washers of suitable size, including taking down old UNSV bracket complete all as specified and directed .
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete complete all as specified and directed. (Make: Crompton/Bajaj/Philips/Havells)
S&F in replacement PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning all as directed. Make: Plaza/ Gloster/Polycab.
Supply and fixing in replacement of SMC junction box of size 270mm x 225 mm x 135 mm hinged type door 4 Nos terminal with 6-20 Amp MCB fixing on pole with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc including taking down old UNSV complete all as specified and directed. Make- Sintex/Hensel/Trinety or equivalent make approved by GE
Labour for Repair/ maintenance of street lights/ yard lights/ high mast fitting/Bollard /garden luminaire of any size/ type fixed on poles/bldgs/tower including taking down as required at a height exc. 8m from the ground level including dismantling all the defective components, checking its serviceability circuit board, driver units and carried out necessary minor repairs/soldering of worn out circuits /connections, replacement of unserviceable parts and refixing the same after repair including connecting and testing the same, replacing the fused lamps, burnt out wiring, ballast and igniter, capacitor and reassembling and fixing the fitting to original position complete, testing and commissioningcomplete all as specified and directed . Replacement of fused wire is deemed to be included and other items will be measured and paid separately under relevant items, however securing wiring/ tapeing/refixing is deemed to be included in Job. Note: (a) Irrespective of fittings/ components replaced, the measurement shall be made for one pole as one unit. (b) Attending through necessary ladder arrangement on vehicle or ladders etc shall be arranged by the contractor. (c) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (d) Contractor is completely responsible for the safety of manpower employed by him.
Supply only the following for fixing against defective componets under relevant Item No 12
(a) Driver unit suitable for LED street light fittings of 45/60 watts
(b) MCPCB unit suitable for LED street light fittings of 45/60watts
(c) Surge protection suitable for LED street light fittings of 45/60 watts
(e) Driver unit suitable for LED bollard light fittings of 10/12 watts
(f) MCPCB unit suitable for LED bollard light fittings of 10/12 watts
(g) Surge protection suitable for LED bollard light fittings of 10/12 watts
Labour for Repair/maintainace of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, meggering, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit will be paid separately in concerned items (b) Excavation, refilling and sand/cable covers as used will be paid separately. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (e) The fuse of call/breakdown and defect identification to be attended immediately within 2 hrs and process for proper defect identification should be completed in continuation alongwith any further workmen or equipment required as defect rectification being essential service in nature and the cost is deemed to be included in scope of work and also as directed. (f) Contractor is completely responsible for the safety of manpower employed by him.(g) The contactor need to arrange necessary skilled manpower immediately to restore the essential electrical services.
Dismantling and taking out old un-serviceable Non-integral light fittings from 13.5 mtr High mast tower with checking its connection and unserviceable parts ,such as Drivers,LED lamps ,LED Fittings etc and replace the same and refitting in its position including servicing the double drum winch and greasing the 5 mm dia steel wire rope, wheels,operating handles with all parts and equipments of existing High mast Tower ,fitting ,Allignment upto length, testing complete in all respect after the high mast tower mounted all as specified and directed. Note: The Lights fittings to be replaced shall be measured seperately under this schedule of item.
Supply only the following for fixing against defective componets under relevant Item No 15
(a) Driver unit suitable for LED Flood light fittings of 150/180/200 watts
(b) MCPCB unit suitable for LED Flood light fittings of 150/180/200 watts
(c) Surge protection suitable for LED Flood light fittings of 150/180/200 watts
Supply and fixing in replacement of energy saving environmental friendly, long life LED flood light fitting 170 watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperete driver compartment with IP 66 protection including taking down old unserviceable light fitting from high mast complete all as specified and directed.
M&L for replacement of Steel wire rope of size 5 mm dia ( as per existing) with required nuts,bolts and hooks including taking down old U/S steel wire rope from different high mast towers.
S&F in replacement MCCB 4 pole with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 63 Amps.
Supply and fixing in replacement of MCCB 4 pole , 100 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board
Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 36 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board
S&F for replacement of on load change over switch with enclosure 3 phase 415 volt 50 Hz 63 Amp to be fixed in existing panel.
M&L for Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends or edge steps,cills,sunshades,shelves,lintels,etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size all as specified and directed.
Supply and fixing of neon light (RYB) complete on existing LT panel board including dismantling and taking out of old items complete with connected wiring for Phase indication all as directed and specified.
Supply and fixing of Amperemeter digital (0-100)Amp, along with CT's complete on existing LT panel board including dismantling and taking out of old items
Supply and fixing Voltmeter digital type with of (0-440) Volt on existing LT panel board including dismantling and taking out itms complete with connected wiring for Phase indication all as directed and specified
M & L for Repair of air break gang operated switches vertical/horizontal type by repair/ replacement of broken/worn out components & insulators and greasing the moveble parts ( Male/female parts) for smoth functioning complete all as specified and directed by Engr-in-Charge.
Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up all as directed.
M & L for painting of two pole structure (11 metre long) with aluminium paint after removing old paint from pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint all as specified and directed by Engr-in -Charge
Supply & fixing in replacement of breather Assembly for upto 315 KVA Transformer Make : MB Supplier/Pooja industries/Goyal electric works.
S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 315 KVA Transformer complete in all respect & all specified.
M&L for Filtration and Dehydration of transformer oil of Transformers at different location of CGRA/CGAE with filtration cum dehydration machine to achieve desired level of di electric strength of transformer oil including testing complete as specified and all as directed by engineer in charge. Note- The quoted rate shall deem to incl for the cost of centrifuging the transformer oil by means of electrical operated centrifuging machine . (ii) The contrator shall test the di electric strength of oil of each transformer before dehydration & filtration and after completion of dehydration and filtration process he shall submit record of the same. Each sample of oil shall be tested with a transformer oil test machine at site in presence of concerned JE/ Engr- in- Charge. The contractor will have to arrange correctly calibrated Transformer Oil Test machine. for this purpose. (iii) The dielectric strength should not be less than 45 KV.
Supply and fixing in replacement of air break Gang operating Drop Out (GODO) switch vertical / horizontal typeTriple pole, mechanically operated, mounted on 12 insulators and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11 KV complete with testing all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-Charge.
M & L for metal spreading around the two pole structure including cleaning & removing grass of the area 4mx3m approx around the two pole structure. Spreading & leveling sand cushioning 15 mm over the cleaned surface and spread150 mm thick stone aggregate, 40 mm graded including painting of concrete surface complete all as specified and directed by Engr-in-Charge.
M&L for complete routine test of transformer of Cap upto 315 KVA (as per IE rules) with authorised agency as per the direction of Engr-in-Charge and submit the all routine test certificate by the authorised agency to Engr-in-Charge for maint of our record of any capacity of transformer complete all as directed
S&F in replacrment of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11KV greasing the moveble parts ( Male female parts) for smoth functioning complete all as spcified and directed.
M & L for painting of Street light pole (9 metre height) with aluminium paint after removing old paint from steel pole & other steel section such as angle, bracket & support clamps etc and inclusive of one over coart and one finishing coat of aluminium paint complete with numbering of pole all as specified and directed by Engr-in -Charge
M & L for Servicing of DG set through authorised agency "B" check in replacement of fuel filter, primary and secondary, superbypass filter,oil filter. Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil etc. and refitting for DG set including drain out (used) engine oil and filling new engine oil complete for the following cpacity (a) :- Capacity 200 KVA, 125KVA,62.5 KVA & 82.5 KVA Note:- (a) Engine oil will be measured and paid separately as supply only under respective items of schedule 'A'. (b) Filter will be replaced in each servicing of DG Set shall be measured and paid separately as supply only under respective items of schedule 'A'.
Supply only engine oil suitable for diesel generator set (Oil 15W/40). Make: Servo/ HP / Bharat Petroleum.
Supply only coolant suitable for radiater of DG sets. Make : HP/TVS/Servo
S/F in replacement of battery terminal brass(heavy duty)with nuts & bolts for battery (as per sample)
Supply only Air filter and air pre filter to DG set of following capacities: (a ) Capacity of 62.5KVA, 82.5 KVA , 125 KVA & 200 KVA
Supply only diesel filter to DG set of following capacities: (a ) Capacity of 62.5KVA, 82.5 KVA , 125 KVA & 200 KVA
Supply only Oil filter set (Lube oil filter+ O ring & by pass Lube oil filter+ O ring) (a ) Capacity of 62.5KVA, 82.5 KVA , 125 KVA & 200 KVA
Supply and fixing, in replacement, Radiator cap suitable for DG Set of any type / make and capacity, complete all as directed.
Material & labour for carrying out complete overhauling / servicing of DG set panel/ control panel, including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation, complete all as directed.
M & L for replacement of Governor of Dg set of capacity 125 KVA complete with made functional including change of spare parts if required all as specified and directed.
M & L for servicing of Water pump of Dg set of any capacity upto 200 KVA complete with made functional including change of spare parts if required all as specified and directed.
M&L for Reapirs to DG set door by welding and Brazing complete with locking arrangements all as specified and directed.
Supply and fix DG set diesel tank cap with locking arrangements complete as per existing.
S&F in replacement of automatic battery charger of 24 Volt 10 A complete all as specifed and directed.
Disconnecting and removing existing unserviceable battery and S & F maintenance free battery 12V, 180AH with minium 2 years guarantee all as specified and as directed by Engineer-in-Charge.( Make : Exide/Amco/Amaron)
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts out door type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT Panel fabricated from 3.15 mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade, fully compartmentalized design with 4 Nos of copper bus bar of 500 Amps capacity each and supply and fixing the following including taking down old panel with accessories:- ( Main LT Panel) Incoming a) Incoming MCCB 320 A, 4 Pole, 50KA - 1 No (b) Ammeter 0-200 Amps 96 mm square digital type-01 No. (c ) Voltmeter --500V digital type 96 mm square-01 No, (d) LED Indication lamps -01 Set of three
Outgoing (a) MCCB 63 A, 35KA, 3P - 3 Nos (b) MCCB 125 Amps, 35 KA, 4P- 02 Nos. (c)Time switch Astro type (having longitude and latitude of indian cities in memeory) single phase, 250 V, 20 Amp rating-01 No
Dismantling and taking down hot water tank 500 ltrs capacity from the tank stands after disconnecting of in inlet and outlet pipe lines and remove tanks from bldg roof all as per directed.
Supply, fixing and testing new pressurised hot water tanks of capacity 500 ltrs on same place of existing tank and connecting both outlet and inlet pipes complete in all respect for working satisfactorily all as specified and directed.
M & L for de-scaling of Flat type collector with suitable water softening agent or by circulating mild acidic solution through the collector pipes and drain out the scaling materials from the collector all as directed by Engr-in-Charge.
Supply & Fix in repair Sub main wiring two run of 4 sqmm single core PVC insulated unsheathed cable single core multistranded copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 4 sqmm PVC insulated copper cable for continuous earth conductor connected to common earth dolly. Note – 2 Nos of single core cable along with earth wire and PVC conduit shall be measured as one length.
Supply and fix, in replacement, Sacrificial Anode for better performance of Solar Water Heater.
Supply and fix, in replacement, Gun metal gate valve conforming to IS-778-1984 non rustable spindle with cast iron wheel ISI marked suitable for screwing in GI pipes of 25 mm size complete.
Supply and fix, in replacement, PVC/rubber hot and cold water pipes of 1" for inlet and outlet connection of collector complete without any leakages.
Supply and fix in replacement GI tubing, medium grade, with all fittings 20 mm dia fixed on the floor/roof top for inlet and outlet connection complete.
Supply and fix in replacement hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore complete.
Supply and fix Rotational moulded polyethylene water storage tanks of 500 Ltrs Capacity (cylindrical vertical with closed top) hoisted and fixed in position of top of the bldg having upto 8 floor all as specified in SSR Part I including dismantling of old U/S water tank complete all as specified and directed.
Supply and fix in replacement 40 mm Ball Valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, (Minimum weight 20 mm-210 gms all as specified and as directed by Engr-in-Charge.
M & L for repairing and Painting of steel structures of Solar Water Heating System installed at the roof top bldg upto 8 th floor complete as per directed.
S & F in replacement of Elevated medium type intensity light fitting suitable for taxi way apron edge lighting with following accessories. Make:-AMA/SKYBRABY/ALLEN enterprises. (a) CI Box-01No (b) Base plate with 6 Nos stainless steel bolts-01 No © Breakable coupling -01No (d) Blue shed -01No (e) Aluminium clamp-01No (f) 45 Watts isolating Transformer -01No (g) 45 Watts tubular lamp -01No (h) Connector kit-01No (j) Gasket (k) Two pin lead.
M & L for repairs to Taxi light by replacing transformer , PCB board ,Bulb, soldering work etc complete for proper working of Taxi track lights all as specified and directed.
Supply & Fixing in replacement of Aviation Obstruction Light of LED Type 5.8W, 50 Hz, 180-280 V red color complete all as specified & directed.
SHREE ENTERPRISES (BID ID -3455187)
SMART ENERGY SOLUTIONS (BID ID -3453960)
Shree Mahavir Associates (BID ID -3455670)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
TENDER.pdf
Tender Documents • 1.32 MB
BOQ_820897.xls
BOQ • 1.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .